| Sl No | Description | Qty | Unit | PECTHERM PRIVATE LIMITED L1 | NIGHTINGALE TRADING ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing, and Commissioning of Following Standby Units for the Existing 500 LPM PSA Oxygen Plant at 200-Bedded Hospital, Kargil, including RCC/PCC Foundation Works as per Equipment Specifications and Site Engineer’s Instructions, Complete Interconnections, System Integration, and make good of All Disturbed Surfaces/Damages: | |||||
| 2.00 | Air Compressor:
Silent type reciprocating air compressor, skid-mounted, acoustically enclosed, designed for continuous duty. Compatible with the 500 LPM PSA Oxygen Plant. Includes air-cooled system, anti-vibration mounts, electrical motor with control panel, and all standard OEM-supplied accessories. Civil foundation and all interconnections included.
• Type: Silent type (acoustic canopy fitted), reciprocating, skid-mounted
• Make/Model: Chicago Pneumatic PX 100-7-A-E
• Capacity: Approx. 524 CFM @ 7 bar (compatible with 500 LPM oxygen generator/concentrator module)
• Duty Cycle: 100% continuous duty
• Cooling System: Air-cooled, complete with standard accessories
• Motor: 75 kW (100 HP), 3-phase, 415 V ±10%, 50 Hz
• Shaft Power: 74.9 kW
• Accessories: Anti-vibration pads and all standard OEM-supplied accessories | 1 | Complete Job | 28,00,000 ₹28,00,000 Lowest | 34,00,000 ₹34,00,000 |
| 3.00 | Air Dryer Unit
Energy-efficient refrigerated air dryer suitable for continuous operation, compatible with the output from the standby air compressor. Ensures removal of moisture and maintains required air quality standards. Includes inbuilt moisture separator, dew point monitoring system, pre and post-filtration stages. Civil foundation, electrical and piping interconnections included.
Make/Model: Chicago Pneumatic CPZ 6002
Capacity: Compatible with 524 CFM compressor output | 1 | Complete Job | 4,20,000 ₹4,20,000 Lowest | 5,00,000 ₹5,00,000 |
| 4.00 | Compressed Air Filtration System:
Complete filtration system ensuring air quality as per ISO 8573 Class 4 with a filtration grade of 0.01 Micron. Includes inlet micro-filter, activated carbon filter, and outlet fine dust filter. Ensures clean, dry air supply to the oxygen concentrator module. Interconnection piping, mounting frame, and all accessories included.t
Acceptable Makes: Walker Filtration / Ultrafilter / Trident | 1 | Complete Job | 1,20,000 ₹1,20,000 | 1,00,000 ₹1,00,000 Lowest |
| 5.00 | Oxygen Concentrator Module:
PSA-type oxygen concentrator module with a capacity of 500 LPM, providing
medical-grade oxygen purity of 95% ±1%. Includes , interconnecting insulated piping, nuts, bolts, and related accessories. Fully
compatible with the existing oxygen supply system.
Acceptable Makes: INMATEC / OXYPLUS/Equivalent
Oxygen Purity: 95% ±1%
Oxygen Pressure: 4.5 – 6.0 bar
Process: PSA | 01 Complete Set | | 1 | Complete Job | 38,00,000 ₹38,00,000 Lowest | 46,40,000 ₹46,40,000 |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
21 Jul 2025, 2:00 pmClosed
Executive Engineer Mechanical Divisi
office of Executive Engineer Mechanical Division Kargil.
Supply, installation, testing and commissioning Standby EquipmentSs to be integrated with the Existing 500 LPM PSA Oxygen Plant and Oxygen Booster for the 300-Bedded District Hospital, Kargil
2025_PWD_16846_2
MDK/E-NIT/20 OF 2025-26
Open Tender
Miscellaneous Works
Turn-key
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
Executive Engineer Mechanical Divisi
₹2.4 L
Kargil
15 Sept 2025
14 Jul 2025
22 Jul 2025
14 Jul 2025
21 Jul 2025
14 Jul 2025
18 Jul 2025
Amount
Supply, Installation, Testing, and Commissioning of Following Standby Units for the Existing 500 LPM PSA Oxygen Plant at 200-Bedded Hospital, Kargil, including RCC/PCC Foundation Works as per Equipment Specifications and Site Engineer’s Instructions, Complete Interconnections, System Integration, and make good of All Disturbed Surfaces/Damages:
Air Compressor: Silent type reciprocating air compressor, skid-mounted, acoustically enclosed, designed for continuous duty. Compatible with the 500 LPM PSA Oxygen Plant. Includes air-cooled system, anti-vibration mounts, electrical motor with control panel, and all standard OEM-supplied accessories. Civil foundation and all interconnections included. • Type: Silent type (acoustic canopy fitted), reciprocating, skid-mounted • Make/Model: Chicago Pneumatic PX 100-7-A-E • Capacity: Approx. 524 CFM @ 7 bar (compatible with 500 LPM oxygen generator/concentrator module) • Duty Cycle: 100% continuous duty • Cooling System: Air-cooled, complete with standard accessories • Motor: 75 kW (100 HP), 3-phase, 415 V ±10%, 50 Hz • Shaft Power: 74.9 kW • Accessories: Anti-vibration pads and all standard OEM-supplied accessories
Air Dryer Unit Energy-efficient refrigerated air dryer suitable for continuous operation, compatible with the output from the standby air compressor. Ensures removal of moisture and maintains required air quality standards. Includes inbuilt moisture separator, dew point monitoring system, pre and post-filtration stages. Civil foundation, electrical and piping interconnections included. Make/Model: Chicago Pneumatic CPZ 6002 Capacity: Compatible with 524 CFM compressor output
Compressed Air Filtration System: Complete filtration system ensuring air quality as per ISO 8573 Class 4 with a filtration grade of 0.01 Micron. Includes inlet micro-filter, activated carbon filter, and outlet fine dust filter. Ensures clean, dry air supply to the oxygen concentrator module. Interconnection piping, mounting frame, and all accessories included.t Acceptable Makes: Walker Filtration / Ultrafilter / Trident
Oxygen Concentrator Module: PSA-type oxygen concentrator module with a capacity of 500 LPM, providing medical-grade oxygen purity of 95% ±1%. Includes , interconnecting insulated piping, nuts, bolts, and related accessories. Fully compatible with the existing oxygen supply system. Acceptable Makes: INMATEC / OXYPLUS/Equivalent Oxygen Purity: 95% ±1% Oxygen Pressure: 4.5 – 6.0 bar Process: PSA | 01 Complete Set |
NIGHTINGALE TRADING ENTERPRISES (BID ID -164334)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .