| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.5 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹17.8 L+₹1.3 L (8.12%)Rejected-Finance 256 MUNDHELA KHURD NEW DELHI 73 | 2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical No registration document submitted by the bidder |
Tender Value
₹19.5 L
EMD Value
₹39,069
Closing Date
21 Feb 2024, 3:00 pmClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,CSPZ, MLUG Car Parking, Asaf Ali Road, Delhi-110002
Provision of electrical installation in auditorium 5th floor including AC, PA system and CCTV at GLM hospital under City SP zone
2024_MCD_186343_1
MCD/TR/422/2024_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
City- SP, AJMERI GATE
refer special conditions
2 documents required · 2 mandatory
₹590
₹39,069
29 Mar 2024
15 Feb 2024
21 Feb 2024
15 Feb 2024
21 Feb 2024
16 Feb 2024
Amount
DSR item
OD23534/2023-2024:(DSR1.10.3) Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD23579/2023-2024:(DSR1.14.2)Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed pvc conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire
OD23580/2023-2024:(DSR1.14.3)Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed pvc conduit as required2x4 sq.mm + 1x4 sq.mm earth wire
OD23581/2023-2024:(DSR1.17.30)Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
OD23582/2023-2024:(DSR1.21.2)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD23583/2023-2024:(DSR1.24.1)Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
OD23584/2023-2024:(DSR1.24.3)Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
OD23585/2023-2024:(DSR 1.24.4)Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
OD23586/2023-2024:(DSR 1.24.5)Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
OD23587/2023-2024:(DSR1.32)Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
OD23588/2023-2024:(DSR1.50.1)Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
OD23589/2023-2024:(DSR 2.2.1)Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
OD23590/2023-2024:(DSR2.2.2)Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp,16 KA,TPMCCB
OD23591/2023-2024:(DSR2.2.4)Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 Amp, 16 KV ,TPMCCB
OD23592/2023-2024:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 Amp, 25 KA,TPMCCB
OD23593/2023-2024:(DSR2.2.9)Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.400 Amp, 35 KA,TPMCCB
OD23594/2023-2024:(DSR2.3)Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
OD23595/2023-2024:(DSR 2.4.3)Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
OD23596/2023-2024:(DSR2.10.1)Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD23597/2023-2024:(DSR 2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD23598/2023-2024:(DSR2.018) Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
OD23599/2023-2024:(DSR 7.5.1)Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
OD23600/2023-2024:(DSR 7.7.1) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD23609/2023-2024:(DSR1.53.1)Supplying and drawning of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD23610/2023-2024:(DSR1.53.2)Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 2 run of Cable
OD23611/2023-2024:(DSR1.53.3)Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable
OD23614/2023-2024:(DSR17.3.3)Supplying, installation, testing & commissioning of 1.5/3/6Wmetal box ceiling/wall speakers complete as required
OD23616/2023-2024:(DSR17.3.7)Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
OD23617/2023-2024:(DSR19.1)Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD23620/2023-2024:Supply, laying & Fixing of Speaker Lines: 2-Core, 2.5 sq mm High definition Speaker Cable, PVC insulated in PVC jacket laid in existing conduits as reqd
OD23621/2023-2024:Supply Installation testing & Commissioning of 18" Gooseneck cardioid Microphone, polar pattern cardioid, 9 Frequency Range 70-18000 Hz, Sensitivity 18mV/Pa, Impedance>2000 ohms. Complete with desk stand with switch etc. as reqd
Approved rates
122.1.11:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3C*25 sqmm
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.46:"SITC of 4MP fixed lens Dome IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL "
122.2.47:"SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL "
122.2.58:"SITC of 8 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better Network Throughput :80Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 1 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL "
122.2.62:SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
122.2.67:SITC of 8 TB surveillance HDD
122.2.71:"SITC of full HD LED Monitor,55 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. complete as required. "
122.2.72:SITC of IP65 box (without PoE switches)of dimention 310mmX160mmX140 mm on pole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.82:SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
122.2.114:S/I/T/C of stand for split AC
122.2.117:S/I/T/C of copper pipe for split AC
122.2.118:S/I/T/C of Drain Pipe
122.2.119:S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner
122.2.131:Supply, Installation, Testing and Commissioning of 1.5 Ton, 5 Star rated Inverter Split air conditioner with rotary compressor (R32 Refrigerant) having copper condenser complete with outdoor unit as required.
122.2.115:S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
OD23647/2023-2024: Supply of heavy Duty Exhaust fan of 15''(380 mm), 1400 RPM in metal frame working on 230 V A/C Exhaust Fan complete with ring, blade etc as required. ISI marked.
DEV ENGINEERS
Bidder Name
DEV ENGINEERS
M/S. A.K. Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .