Loading…
Loading…
Tender Value
₹40.0 L
EMD Value
₹40,000
Closing Date
15 May 2026, 4:00 pmClosed
EXECUTIVE ENGINEER, NADIAD O&M DIVISION
ARC for erection of HT/LT and TC and Maintenance work at GALTESHWAR S.dn/ anywhere under Kheda district with cost of Nut-Bolt under Revamped Reforms- Based and Result-linked Distribution Sector Scheme and other scheme as per specification, terms and condition of tender.
299931
NDR/RDSS/HT-LT/2026-27/06
Open
Power/Energy Projects/Products/Services
Works
Kheda
₹1,770
MADHYA GUJARAT VIJ COMPANY LTD
₹40,000
30 Apr 2026
30 Apr 2026
30 Apr 2026
15 May 2026
30 Apr 2026
NO No. Nut & bolt
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,INSULATORS, ETC,
1. 9901000001 COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING Number
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDINGERECTION OF GUY SET AND EARTHING
ERECTION OF LT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
2. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF
GUY SET AND EARTHING
ERECTION OF HT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
3. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF
GUY SET AND EARTHING
ERECTION STEEL POLES OF 8 TO 9 & 11 METERS INCLUDING EXCAVATION OF
PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS,
ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. COMPLETE AND
4. 9902010003 Number
PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUT SET AND EARTHING.
ERECTION STEEL POLES OF 13 METERS FOR RAILWAY CROSSING ON
BG/MG/NG/LINE FOR 0.400/11/22KV OVERHEAD LINE I.E. INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
5. 9902010004 FITTING CLAMPS, ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. Number
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS PSC POLE INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS,
6. 9902020001 INSULATORS, ETC., COMPLETE AND PAINTING OF POLES FABRICATED Number
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRUCTURE OF 8 TO 9 METERS STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF
CHANNELS, SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES
7. 9902020007 DANGER BOARDS, INSULATORS, ETC., COMPLETE AND PAINTING OF POLES Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH /
HG FUSES OF 8 METERS, 200 KG PSC POLES INCLUDING EXCA-VATION OF PITS
AND REFILLING OF EARTH, FIXING OF CHANNELS,SUPPORTING ANGLES
8. 9902020006 CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARD, INSULATORS, DO FUSES, Number
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH / HG
FUSES, 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
9. 9902020010 ANTI-CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC., COMPLETE Number
AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH /
HG FUSES, 13 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
10. 9902020019 ANTI-CLIMBING DEVICES , DANGER BOARDS INSULATORS, ETC COMPLETE AND Number
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF HG FUSES, 5 KVA
TRANSFORMERS, LIGHTENING ARRESTERS AND WITHOUT DISTRIBUTION BOX
ETC OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, CARTING OF TRANSFORMERS FROM STORE TO SITE,
11. 9902030021 FIXING OF CHANNELS SUPPORTING ANGLES, BRACING CROSS ARMS, CLAMPS Number
ANTI-CLIMBING DEVICE DANGER BOARDS CONDUCTOR AND CABLE WIRING
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF EARTH,
CARTING OF TRANSFORMERS, FROM STORE TO SITE FIXING OF CHANNELS SUPPORTING
12. 9902030001 Number
ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICE DANGER BOARDS
CONDUCTOR AND CABLE WIRING ETC.,COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS, SUPPORTING
13. 9902030024 Number
ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS, SUPPORTING
14. 9902030012 Number
ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF GUY SETS INCLUDING EXCAVATION OF PITS & REFILING OF
EARTH, AS PER STANDARD SPECIFICATION WITH STAY CLAMPS STAY WIRES,
ANCHOR ROD, TURN BUCKLE, EYE BOLT, GUY INSULATOR, CEMENT
CONCRETE BLOCK, ETC., BUT EXCLUDING CONCRETING.
CONCRETING/ MUFFING OF POLES GUY ETC., INCLUDING COST OF
CEMENT,AND Cubic
METAL (1:2:4) AND WATER ETC., AS PER C.C.M-20 GRADE STANDARD Meter
SPECIFICATION .
ERECTION COIL TYPE EARTHING INCLUDING COST OF COIL,COAL SALT, ETC
BUT WITHOUT COST OF G I WIRE AS PER STANDARD SPECIFICATION 10 KG
17. 9902040002 Number
SOLT + 10KG COAL. FOR CONSUMER OR POLE AS PER TECHNICAL
SPECIFICATION PROVIDED WITH TENDER.
ERECTION OF GI PIPE / C I PLATE TYPE EARTHING INCLUDING COST COAL
18. 9902040003 SALT, ETC BUT WITHOUT COST OF GI PIPE / CI PLATE AS PER STANDARD Number
SPECIFICATION…20 KG SOLT + 20KG COAL.
SRTINGING OF 34MM2 ,55MM2,AAA CONDUCTOR, FOR 11 KV & L.T. LINE one cond
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC. per Km
SRTINGING OF 100 MM2, ACSR/DOG CONDUCTOR, FOR 11 KV & L.T.LINES one cond
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC. per Km
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF Kilo
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN- Meter
CHARGE A: 3 X 50MM2+16MM2+1X 35MM2
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
22. 9903000005 FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-
CHARGE A : 1 X 35MM2 + 1 X 25MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN URBAN AREA
INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
23. 9903000007 FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC
AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM21X 80MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN RURAL AREA
INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
24. 9903000007 FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC
AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM21X 80MM2
Supply and fixing Heat Shrinkable type cable joint kit suitable for 11KV 1core X 95/70
sqmm AB cable for outoor termination application.
Supply and fixing Heat Shrinkable type straight joint kit suitable for 11KV 1core X 95/70
sqmm AB cable for outoor application.
27. 9906000002 PROVIDING GUARDING TO HT LINE ON ROAD/RAIL CROSSING RMT
28. 9906000001 PROVIDING GUARDING OF LT LINE ON ROAD/RAIL CROSSING RMT
29. 9901000002 LT LINE TAPPING SINGLE PHASE. Number
30. 9901000003 LT LINE TAPPING THREE PHASE. Number
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING HT LINE CROSSING
31. 9911000017 Meter
AND TELEPHONE LINE CROSSING ETC (PER SPAN)
Dismentalling of all size (8,9,11,13…mtrs.) of RSJ (girder) Poles including dimentalling
32. 9907000006 of relevant channels, cross arms insulators, jumpers, binding, earthing etc. including Number
crediting in store
Dismentalling of PSC Poles including dimentalling of relevant channels, cross arms
33. 9907000002 Number
insulators, jumpers, binding, earthing etc. including crediting in store
34. 9907000009 Dismentalling of conductor from line. including crediting in store
35. 9907000012 Dismentalling of PSC Pole D.P.Structure. including crediting in store Number
36. 9907000025 Dismentalling of 2 W A.B.Cable from line. including crediting in store
37. 9907000025 Dismentalling of 4 w A.B.Cable from line. including crediting in store
INSTALLATION OF ENERGY METER & MMB/SMC BOX WITH ELECTRICAL WIRING
38. 9911000057 Number
ON TRANSFORMER
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC CABLE FROM
39. 9904010002 Number
TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
PROVIDING THREE PHASE FOUR WIRE SERVICE CONNECTION WITH PVC
40. 9904010001 CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF Number
41. 9909000001 CARTING OF PSC POLE AT DESTINATION(ABOVE 5 KM) Number
42. 9909000006 CARTING OF RSJ POLE AT DESTINATION(ABOVE 5 KM) Number
REPLACEMENT OF FAIL TRANSFORMER & AUGMENTATION /
43. 9908000049 DEAUGMENTATION OF TRANSFORMER(ANY CAPACITY) INCLUDING Number
TRANSPORTATION & CREDIT OF OLD TRANSFORMER AT S/DN STORE
44. Unbundling & Fixing of 95 mm2/71mm2 HT ABC on existing Pole
45. 9907000031 Dismantling of HT ABC (Urban) Km
46. 9907000031 Dismantling of HT ABC (Rural) Km
47. 9907000032 Unbundling of HT ABC Km
48. 9903000008 Stringing of Unbundled HT ABC per Cond
49. 9911000226 Re Fixing of V cross arm Number
50. 9911000010 Re Fixing of Top fitting Number
51. 9911000190 Re jumpering of HT/LT Line for Shackle pole Per/pole
52. 9908000166 Replacement of LT Pin/Shackle Insulator No
53. 9908000008 Fixing of Shackle Insulator with Hardware No
Rates For Emergency Work
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,INSULATORS, ETC,
54. 9901000001 COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING Number
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDINGERECTION OF GUY SET AND EARTHING
ERECTION OF LT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
55. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF
GUY SET AND EARTHING
ERECTION OF HT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
56. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF
GUY SET AND EARTHING
ERECTION STEEL POLES OF 8 TO 9 & 11 METERS INCLUDING EXCAVATION OF
PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS,
ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. COMPLETE AND
57. 9902010003 Number
PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUT SET AND EARTHING.
ERECTION STEEL POLES OF 13 METERS FOR RAILWAY CROSSING ON
BG/MG/NG/LINE FOR 0.400/11/22KV OVERHEAD LINE I.E. INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
58. 9902010004 FITTING CLAMPS, ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. Number
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS PSC POLE INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS,
59. 9902020001 INSULATORS, ETC., COMPLETE AND PAINTING OF POLES FABRICATED Number
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRUCTURE OF 8 TO 9 METERS STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF
CHANNELS, SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES
60. 9902020001 DANGER BOARDS, INSULATORS, ETC., COMPLETE AND PAINTING OF POLES Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST
OF PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING. ( W/O AB SWITCH ).
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH /
HG FUSES OF 8 METERS, 200 KG PSC POLES INCLUDING EXCA-VATION OF PITS
AND REFILLING OF EARTH, FIXING OF CHANNELS,SUPPORTING ANGLES
61. 9902020004 CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARD, INSULATORS, DO FUSES, Number
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH / HG
FUSES, 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
62. 9902020010 ANTI-CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC., COMPLETE Number
AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH /
HG FUSES, 13 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
63. 9902020022 ANTI-CLIMBING DEVICES , DANGER BOARDS INSULATORS, ETC COMPLETE AND Number
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF HG FUSES, 5 KVA
TRANSFORMERS, LIGHTENING ARRESTERS AND WITHOUT DISTRIBUTION BOX
ETC OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, CARTING OF TRANSFORMERS FROM STORE TO SITE,
64. 9902020004 FIXING OF CHANNELS SUPPORTING ANGLES, BRACING CROSS ARMS, CLAMPS Number
ANTI-CLIMBING DEVICE DANGER BOARDS CONDUCTOR AND CABLE WIRING
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF EARTH,
CARTING OF TRANSFORMERS, FROM STORE TO SITE FIXING OF CHANNELS SUPPORTING
65. 9902020004 Number
ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICE DANGER BOARDS
CONDUCTOR AND CABLE WIRING ETC.,COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS, SUPPORTING
66. 9902030016 Number
ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF CHANNELS, SUPPORTING
67. 9902020010 Number
ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI CLIMBING, DEVICES, DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF GUY SETS INCLUDING EXCAVATION OF PITS & REFILING OF
EARTH, AS PER STANDARD SPECIFICATION WITH STAY CLAMPS STAY WIRES,
ANCHOR ROD, TURN BUCKLE, EYE BOLT, GUY INSULATOR, CEMENT
CONCRETE BLOCK, ETC., BUT EXCLUDING CONCRETING.
CONCRETING/ MUFFING OF POLES GUY ETC., INCLUDING COST OF
CEMENT,AND Cubic
METAL (1:2:4) AND WATER ETC., AS PER C.C.M-20 GRADE STANDARD Meter
SPECIFICATION .
ERECTION COIL TYPE EARTHING INCLUDING COST OF COIL,COAL SALT, ETC
BUT WITHOUT COST OF G I WIRE AS PER STANDARD SPECIFICATION 10 KG
70. 9902040002 Number
SOLT + 10KG COAL. FOR CONSUMER OR POLE AS PER TECHNICAL
SPECIFICATION PROVIDED WITH TENDER.
ERECTION OF GI PIPE / C I PLATE TYPE EARTHING INCLUDING COST COAL
71. 9902040003 SALT, ETC BUT WITHOUT COST OF GI PIPE / CI PLATE AS PER STANDARD Number
SPECIFICATION…20 KG SOLT + 20KG COAL.
SRTINGING OF 34MM2 ,55MM2,AAA CONDUCTOR, FOR 11 KV & L.T. LINE
72. 9903000001 cond per
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
SRTINGING OF 100 MM2, ACSR/DOG CONDUCTOR, FOR 11 KV & L.T.LINES
73. 9903000002 cond per
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF Kilo
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN- Meter
CHARGE A: 3 X 50MM2+16MM2+1X 35MM2
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
75. 9903000005 FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-
CHARGE A : 1 X 35MM2 + 1 X 25MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN URBAN AREA
INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
76. 9903000007 FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC
AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM21X 80MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN RURAL AREA
INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
77. 9903000007 FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC
AS REQUIRED & DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM21X 80MM2
78. 9906000002 PROVIDING GUARDING TO HT LINE ON ROAD/RAIL CROSSING RMT
79. 9906000001 PROVIDING GUARDING OF LT LINE ON ROAD/RAIL CROSSING RMT
80. 9901000002 LT LINE TAPPING SINGLE PHASE. Number
81. 9901000003 LT LINE TAPPING THREE PHASE. Number
LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING HT LINE CROSSING
AND TELEPHONE LINE CROSSING ETC (PER SPAN)
INSTALLATION OF ENERGY METER & MMB/SMC BOX WITH ELECTRICAL WIRING
83. 9911000057 Number
ON TRANSFORMER
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC CABLE FROM
84. 9904010002 Number
TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
PROVIDING THREE PHASE FOUR WIRE SERVICE CONNECTION WITH PVC
85. 9904010001 CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF Number
N.B.: The above rates mentioned at cl. No.6 (20% higher Rates) are applicable to carry out miscellaneous emergency work such as
Cyclone, Flood, Earthquake, & Accidental damaged by vehicle, in time bound programme. It is inclusive of dismantling & refitting line
materials etc. and dismantling of damaged structure.
Rates For Maintenance Work
86. 4001000176 Patrolling of HT /LT ine per pole & submission of summary report Per Pole
87. 9911000189 Cutting of tree branches obstructing HT / LT line on one tree Per Tree
88. 9911000189 Cutting of bigger size of tree branches / whole tree obstructing HT / LT line Per Day
89. 9902010006 ERECTION OF SUPPORT POLE - PSC Number
90. 9902010007 ERECTION OF SUPPORT POLE - RSJ Number
REPLACEMENT OF POLE MOUNTED 1PH SERVICE CONNECTION BOX
91. 9911000221 Number
INCLUDING RECONNECTING ALL CONNECTIONS
92. 9911000229 PIN BINDING OF 11KV PIN INSULATOR Per Pole
93. 9911000230 PIN BINDING OF LT LINE PIN OR SHACKLE INSULATOR Per Pole
94. 9908000003 REPLACEMENT OF 11 KV DISC INSULATOR Number
95. 9908000001 REPLACEMENT OF V CROSS - ARMS Set
96. 9908000051 REPLACEMENT OF TOP FITTING Number
97. 9908000007 REPLACEMENT OF LT CROSS - ARMS Number
PROVIDING DO FUSE OR AB SWITCH ON DO (FOR ONE SET) WITH FABRICATION
98. 9908000169 & COLOUR CODE JUMPER,INCLUDING PROPER ALIGNMENT OF AB SWITCH Number
NUMBERING THE POLE WITH PAINT BY PREPARING BACK GROUND OF
REQUIRED HEIGHT SURFACE OF ONE COLOUR AND HAVE LETTERING ( 2" & 3"
99. 9911000001 HT ) AS DIRECTED BY IN CHARGE ENGINEER .THE TWO COLOUR SHOULD HAVE Number
BEEN SLECTED AS TO HAVE CONTRAST FOR PROPER
READABILITY.(REQUIRED COLOUR TO BE PROVIDED BY CONTRACTER)
FIXING OF SMC (1-Phase) AT CONSUMER INSTALLATION ( INCLUDING COST OF
100. 9911000222 Number
FIXING OF SMC (3-Phase) AT CONSUMER INSTALLATION ( INCLUDING COST OF
101. 9911000223 Number
102. 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Urban Number
103. 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Rural Number
104. 9911000227 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Rural Number
105. 9911000228 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Urban Number
REPLACEMENT OF SINGLE PHASE OLD SERVICE BY NEW SERVICE INCL
106. 9908000016 .SHORTFALL REEL INSULATORS, EGG INSULATORS, NAILS, FIXING FASTNERS Number
107. 9902040007 ERECTION/PROVIDING LIGHTENING ARRESTOR Number
REPAIRING/ADJUSTING TENSION OF EXISTING GUY/STAY SET INCLUDING
108. 9911000007 Number
PROVIDING/REPLACEMENT OF STAY INSULATOR
109. 9908000050 Refitting LA Number
110. 9911000072 Burning of Thread of LT/ HT Line including cost of Oil bamboo etc Span
Replacement of old jumpers by new jumper/binding/lugs etc. from L.A. to D.O fuse or per
D.O. fuse to T/C jumper
REPLACEMENT OF OLD DISTRIBUTION BOX 200 KVA & ABOVE WITH MAKING
112. 9908000010 Number
ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
REPLACEMENT OF OLD DISTRIBUTION BOX UP TO 100 KVA & ABOVE WITH
113. 9908000011 Number
MAKING ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
RESTRINGING OF HT/LT LINE (55/34 MM2 ) CONDUCTORS / COATED
CONDUCTOR WITH NEW DOUBLE PIN BINDING PER SPAN
115. 9911000224 Re-Stringing of 11kv Aerial Bunch Cable (All Size) per Span with accessory fitting Span
116. 9911000225 Re-Stringing of Dog Conductor with new double pin binding per Span Span
117. 9911000054 Providing spacer between LT line conductor with binding etc. Number
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
118. 9908000460 REPLACEMENT OF 11 KV PIN INSULATOR BY NEW PIN INSULATOR Number
119. 9908000452 STRAIGHTENING OF PSC/RSJ POLE AT PIN POINT Number
120. 9908000453 STRAIGHTENING OF PSC/RSJ POLE AT TENSION POINT Number
STRAIGHTENING OF TILTED DP SET PSC/RSJ POLE ETC WITH REFILLING OF
121. 9908000454 Number
STONE, MUROUM ETC
Estimate value
TOTAL ESTIMATE AMT. WITH GST@ 18% 39,99,980*
The rates are asked above only on percentage basis against estimated amount i.e. item wise rates stated
in the Schedule-B. The tender offer must be specifying the percentage either above or, below to the
estimated amount and it should be clearly specified both in figures and words. Above quantity are
approximate and may vary as per requirement.
1 Above all Rates are inclusive of Bolt and Nut. Contractor to provide Bolt Nut as per company's
specification.
2 Schedule quantity may be increase or decrease but total order value will not increase. Rates as per
Labour cost data 2024-25 considered.
3 Contractor have to carry out maintenance work of 20 % of total order value issued.
4 Note: As far as possible there should not be a situation where re carting is required for more than
Kms. Poles should be carted from Pole factory nearer to the pole requirement, However in
exceptional circumstances if re-carting is required for more than 5 Kms up to 10 Kms then the carting
rates specified may be paid with specific justification of requirement of carting for more than 5 Kms
and with prior approval of EE of division”.
5 On receipt of Sub work Order, immediately contact Engineer In charge of Concern S/dn for line
marking of erection work.
6 Work should be carried out under supervision of authorized MGVCL staff or its authorized agency
(PMA) only.
MGVCL either self or through any third-party agency including PMA whom it deems fit would
be responsible to monitor the QAM measures including verifications and inspections
mentioned above.
7 T.S wise / Work wise material account of sub works order must be given separately.
8 The materials requisition (M.R) should be collected from Concern Sub Division office.
9 "If work is delay for non-availability of any material or objection of line erection work, must be
inform to Concern S/dn office in writing."
10 For extension of time limit of work order, you have to submit written request letter with valid
genuine reason before one month.
11 On completion of work, you have to credit all balance materials to RSO Nadiad.
12 "You have to prepare & submit works bill for Above work within 07 days with material inventory
sheet & Material account sheet & MR/CR/Gate pass copy & HT/LT/TC erected network sketch"
13 "In case of any excess work required while actual execution of work you have to give written
intimation to this office &No excess work should be carried out without prior written permission /
approval from competent authority."
14 For non -painting of RSJ Pole Rs. 1352/- charge deducted from bill amount.
15 "For non -painting of PSC Pole fabrication Rs. 166/- per pole & for PSC DODP Rs. 353/- and for
PSC TC DP fabrication Rs 721/- per DP will be deducted from bill."
16 For non-painting of Pole numbering Rs. 60/- will be deducted per pole.
17 For live electric line crossing work, work should be carried out after Power cut-off and earthing of
Seal & Sign of Executive Engineer,
Contractor with Rubber Stamp MGVCL, Nadiad O&M
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
RDSS GALTESHWAR.pdf
GALTESHWAR SCHEDULE-B RDSS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .