Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC E 261 AMAR COLONY LAJPAT NAGAR IV LAJPAT NAGAR IV SOUTH DELHI DELHI 110024 UDYAM DL 08 0001872 09AAACB0262A1ZF B S 07AAACB0262A1ZJ R 09AAACB0262A1ZF M | SOUTH EAST DELHI | DELHI | 110024 | ₹2.7 Cr Quoted ₹2.4 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹2.8 CrRejected-AOC MECHATRONICS HOUSE S NO 107 WARJE MUMBAI BANGLORE BY PASS HIGHWAY PUNE 411 058 | PUNE | MAHARASHTRA | 411058 | ₹2.8 Cr | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹3.0 CrRejected-AOC G1 12 INDEXEL ENGINEERING ROAD NO 4 I P I A KOTA KOTA RAJASTHAN 324005 UDYAM RJ 24 0006878 08AADCI0760M1ZF R M MII STATUS AS VERIFIED | KOTA | RAJASTHAN | 324005 | ₹3.0 Cr | L3 | Rejected-AOC L3 Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Non-Responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Non-Responsive |
Tender Value
Refer Docs
EMD Value
₹7.5 L
Closing Date
26 Aug 2019, 3:00 pmClosed
Superintending Engineer, ISO, Lucknow
Office of the Chief Engineer, Information System Organization, Irrigation and Water Resource Department, Dr. Ram Manohar Lohia Parikalp Bhawan, Telibagh, Lucknow, Uttar Pradesh -226025
Supply, installation, testing, commissioning, training, Dissemination, Operation and maintenance of SCADA System at Saryu Barrage and Regulators of Saryu Main Canal and Saryu Link Channel, Nanpara, Bahraich (UP)
2019_UPIDW_366720_2
02/SE/ISO/NHP/2019-20
Open Tender
Electronics Equipment
365 days
Saryu Barrage Nanpara
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
National Hydrology Project UPSW IWRD Lucknow
₹7.5 L
LUCKNOW
5 Feb 2021
26 Jul 2019
26 Aug 2019
26 Jul 2019
26 Aug 2019
16 Aug 2019
27 Jul 2019 - 5 Aug 2019
6 Aug 2019
LOCAL CONTROL SYSTEM for Saryu Barrage Control
Supply of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up of minimum 2 hours, 7 inch or above display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification.
Supply of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications.
Supply of Automated Water Level transmitter non-contact RADAR type having 15m range for measuring level & downstream discharge of barrage & canal systems. including all necessary cabling with suitable conduits & electrical fittings complete as per technical specification
Supply of 3 Phase VFD Starter panel for each motor which shall consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Dial Indicator complete as per technical specifications.
Supply of Bullet Camera (Fixed Type)- IP DIGITAL Night Vision (I.R.) Out door Weather Resistant, 2 Mega Pixel 2 OR4Array/ 72 LED Color Camera. 6 OR 8 or 12 MM (According to site suitability) 2 MP Auto Iris Lens in Elegant Metal Die Cast Housing. Outdoor weather resistant IP 66, for monitoring the gates operation complete as per technical specifications.
Supply of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Sensor, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling required for Barrage monitoring. As per technical specifications
Barrage Control Room Equipment’s
Supply of Fabricated Office made of steel corrugated sheets for Barrage Control Room of Size 250 Sq.ft. with Standard Height comprising of all necessary Furniture and Fittings and Air conditioning system complete in all respect as per technical specification for installation of all necessary control room equipment.
Supply of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. All the Electrical fittings will be Industrial Type. Including suitable switch mode power supply (SMPS) ,12” display & cabling with related remote PLC/RTU’s, complete as per technical specification.
Supply, engineering and development of customized SCADA software for complete Barrage automation with life time licensed version as per technical specifications.
Supply of Master server which includes Server with server Rack and industrial grade PC with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications.
NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD. along with dedicated server with sufficient Hard Drive to have memory of at least 30 days as per technical Specifications.
Supply of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 color printer as per technical specifications.
Supply of 110” LED Display/ Video wall / DLP based System for monitoring of SCADA & Surveillance system at Control Room as per technical specifications
Online 3 KVA UPS with Battery system for power back up of Barrage control room equipment’s as per the technical specifications
Supply of laptops & internet connection (4G/3G) along with licenced version of SCADA software for remote viewing & monitoring of Barrage automation.
Supply of Miscellaneous Equipment’s
Supply of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing along with accessories complete as per technical specifications.
Supply of Solar Power system for Electrification and illumination of BCR, Saryu Barrage with power back up of 36 hours, which includes all accessories, cabling etc. as per technical specifications
RELATED SERVICES
Installation, testing & Commissioning of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up of minimum 2 hours, 7 inch or above display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification.
Installation, testing & commissioning of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications.
Installation, testing & Commissioning of Automated Water Level transmitter non-contact RADAR type having 15m range for measuring level & downstream discharge of barrage & Canal Systems. including all necessary cabling & electrical fitting complete, as per technical specification
Installation, testing & commissioning of 3 Phase VFD Starter panel for each motor which consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Dial Indicator complete as per technical specifications.
Installation, testing & Commissioning & integration with NVR located at Barrage Control Room of Bullet Camera (Fixed Type)- IP DIGITAL Night Vision (I.R.) Out door Weather Resistant, 2 Mega Pixel 2 OR4Array/ 72 LED Color Camera. 6 OR 8 or 12 MM (According to site suitability) 2 MP Auto Iris Lens in Elegant Metal Die Cast Housing. Outdoor weather resistant IP 66 for monitoring the gates operation, complete in all respects as per technical specifications.
Installation, Testing & Commissioning & integration with NVR Located at Barrage Control Room of Pan Tilt Zoom (PTZ) Cameras, 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Sensor, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling & conducting required for Barrage monitoring
BARRAGE CONTROL ROOM EQUIPMENT’S
Installation, Testing & Commissioning of Fabricated Office made of steel corrugated sheets for Barrage Control Room of Size 250.00 SqFt with Standard Height comprising of all necessary furniture and fittings and air conditioning system complete in all respect as per technical specifications for housing all control room equipment.
Installation, Testing & Commissioning of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Including suitable switch mode power supply (SMPS) ,12” display & cabling with Industrial grade type electrical fittings for related remote PLC/RTU’s, as per technical specification.
Installation, testing & Commissioning of customized SCADA software for complete Barrage automation with life time licensed version as per technical specifications.
Installation, Testing & Commissioning of Master server with SCADA Software which includes Server with server Rack and industrial grade PC with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications
Installation, testing & commissioning of NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD along with dedicated server with sufficient Hard Drive to have memory of at least 30 days as per technical Specifications.
Installation, Testing & Commissioning of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 colour printer as per technical specifications
Installation, Testing & Commissioning of 110” LED Display/ Video wall / DLP based system for monitoring of SCADA & Surveillance system at Control Room as per technical specifications.
Charges for high speed synchronous internet connection (min. 8 mbps upload and download speed) & Static IP for Five years.
Installation, Testing & Commissioning of Online 3 KVA UPS with Battery system for power back up of Barrage control room equipment’s as per the technical specifications
Installation, Testing and Commissioning of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing, Starter Panel, Energy meter & cabling Complete in all respects as per technical specifications.
Installation, testing & Commissioning of Solar power system which includes solar panel, charger regulator, batteries, lightening arrestor with all connectors, cabling and all required accessories etc. for Electrification & Illumination of Saryu barrage complete with 36 hour Power back up . As per technical specifications
Five Years Operation & Maintenance and Comprehensive Warranty for Barrage automation system as per Price schedule after final acceptance of SCADA & Surveillance system. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GPRS & SIM charges for data transmission, maintenance and repair of Barrage Control room and its fittings and fixtures and other related charges. MINIMUM ONE SERVICE ENGINEER SHALL BE PLACED AT BARRAGE CONTROL ROOM FOR OPERATION OF SCADA & SURVEILLANCE SYSTEM
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC & SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies.
MECHATRONICS SYSTEMS PRIVATE LIMITED
INDEXEL ENGINEERING PVT. LTD.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid