Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC 32 23 A NIMAI CHAI BHAI LANE KHAGRA MURSHIDABAD | ₹2.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.5 LAccepted-Finance 63 PILKHANA ROAD BERHAMPORE MURSHIDABAD 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | ₹2.5 L | L2 | Accepted-Finance |
| 3 | L3₹2.6 LAccepted-Finance ATURIA BADURIA NORTH 24 PARGANAS PIN 743427 | BADURIA | NORTH 24 PARGANAS | WEST BENGAL | 743427 | ₹2.6 L | L3 | Accepted-Finance |
| Sl No | Description | Qty | Unit | M/S. MAYA CONSTRUCTION L1 | S K CONSTRUCTION L3 | MITRA ELECTRONICS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable 2 Loops fire alarm control panel ( VDS / UL / FM / ULC approved ) fully networkable with each loop capable of taking 120 devices, 1/4 VGA display character alphanumeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. (Honeywell/Simense/Cerebus Pro/Secutron/ Bosche) | 1 | nos | 1,26,000 ₹1.3 L | 1,40,000 ₹1.4 L | 1,30,000 ₹1.3 L |
| 2.00 | Supply, Installation,Testing & Commisioning of analog Addressable Intelligent multisensor detector (VDS/UL/FM/ULC approved) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as perrecommended standard. (Note: Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices (Numbers of addressable devices in a froup will be as per latest recommended standards) without any additional cost). (Approved Make:- Honeywell/Simence/Esser/Cerberus Pro/Bosch/Johnson /Secutron System Sensor) | 25 | nos | 1,900 ₹47,500 | 1,920 ₹48,000 | 1,910 ₹47,750 |
| 3.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS/UL/FM/ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required.(Approved Make:-Honeywell/Simence/ Esser/Cerberus Pro/Bosch/JohnsonControls) | 2 | nos | 2,200 ₹4,400 | 2,500 ₹5,000 | 2,300 ₹4,600 |
| 4.00 | Supply, Installation,Testing & Commisioning of Addressable Loop Powerd Hooter (sound output of minimum 90db) cum strobe (strength of light 10 cd) complete with inbuilt isolator and IP65 base and (VDS/UL/FM/ULC approved) (Approved Make:- Honeywell/Esser/CerberusPro/Bosch/JohnsonControls/Notifer/Edward/Secutron/Securiton/Apollo/Morley/System Sensor) | 2 | nos | 10,500 ₹21,000 | 11,000 ₹22,000 | 10,800 ₹21,600 |
| 5.00 | Supply and Laying of 2 Core 1.5sqmm FRLS shielded copper Cable (For Loop) (Make:- Finolex/RR Kable/Polycab) with 20mm NB PVC rigid conduit pipe (Make:- Precision/AKG/Universal/Polycab) on the surface of the wall. | 450 | mtr | 102 ₹45,900 | 105 ₹47,250 | 104 ₹46,800 |
Tender Value
Refer Docs
EMD Value
₹4,900
Closing Date
26 Mar 2025, 12:00 pmClosed
O/o The Assistant Engineer, BESD, PWD
O/o The Assistant Engineer Berhampore Electrical Sub Division P.W.Dte. Station Road, Berhampore, Murshidabad, PIN -742101
Construction of new indoor Building At Amtala Rural Hospital, Nowda Block, Murshidabad --- Supply Installation Testing Commissioning of Fire Detection System.
2025_WBPWD_828604_1
WBPWD/AE/BESD/92/e-Q of 24-25
Open Tender
FIRE FIGHTING ORG
15 days
Murshidabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,900
5 Jun 2026
18 Mar 2025
28 Mar 2025
18 Mar 2025
26 Mar 2025
19 Mar 2025
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable 2 Loops fire alarm control panel ( VDS / UL / FM / ULC approved ) fully networkable with each loop capable of taking 120 devices, 1/4 VGA display character alphanumeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. (Honeywell/Simense/Cerebus Pro/Secutron/ Bosche)
Supply, Installation,Testing & Commisioning of analog Addressable Intelligent multisensor detector (VDS/UL/FM/ULC approved) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as perrecommended standard. (Note: Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices (Numbers of addressable devices in a froup will be as per latest recommended standards) without any additional cost). (Approved Make:- Honeywell/Simence/Esser/Cerberus Pro/Bosch/Johnson /Secutron System Sensor)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS/UL/FM/ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required.(Approved Make:-Honeywell/Simence/ Esser/Cerberus Pro/Bosch/JohnsonControls)
Supply, Installation,Testing & Commisioning of Addressable Loop Powerd Hooter (sound output of minimum 90db) cum strobe (strength of light 10 cd) complete with inbuilt isolator and IP65 base and (VDS/UL/FM/ULC approved) (Approved Make:- Honeywell/Esser/CerberusPro/Bosch/JohnsonControls/Notifer/Edward/Secutron/Securiton/Apollo/Morley/System Sensor)
Supply and Laying of 2 Core 1.5sqmm FRLS shielded copper Cable (For Loop) (Make:- Finolex/RR Kable/Polycab) with 20mm NB PVC rigid conduit pipe (Make:- Precision/AKG/Universal/Polycab) on the surface of the wall.
MITRA ELECTRONICS (BID ID -6272160)
S K CONSTRUCTION (BID ID -6255075)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid