Loading…
Loading…
Tender Value
₹43.0 L
EMD Value
₹43,041
Closing Date
18 Jun 2026, 3:00 pm
Executive Engineer Tharad Division Office UGVCL
OPEN Tender Of ERECTION, MAINTENANCE AND DISMENTALLING WORK OF OVERHEAD HT/LT LINE, TC & HT/LT AB CABLE UNDER WAV SUB DIVISION UNDER THARAD DIVISION.
311766
UGVCL-THARAD-DO-02-2026-27 SNR-05
Open
Electrical and Maintenance Works
Vav-Tharad
1 document required · 1 mandatory
₹1,180
Uttar Gujarat Vij Company Ltd
₹43,041
6 Jun 2026
6 Jun 2026
6 Jun 2026
18 Jun 2026
6 Jun 2026
No. Quantit In figure Amount
HT TAPPING FROM EXISTING POLE
INCLUDING FIXING OF CROSS ARMS, CLAMPS
ANTI CLIMBING DEVICES,DANGER BOARDS,
INSULATORS ETC & PAINTING OF
1(a) FABRICATED MATERIALS AND NUMBERING OF 75 NO. 459
POLE,COMPLETE WITHOUT COST OF NUTS &
BOLTS, PAINTS AS PER STANDARD
SPECIFICATION EXCLUDING OF GUY SET AND
1(B LT LINE TAPING SINGLE PHASE WITH OUT
) COST OF NUTS & BOLTS
1(C LT LINE TAPING THREE PHASE WITH OUT
) COST OF NUTS & BOLTS
ERECTION OF SINGLE POLE STRUCTURE
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH,FIXING OF CROSS
ARMS,TOP FITTING CLAMPS AND ANTI
CLIMBING DEVICES , INSULATORS ETC.
2 COMPLETE AND PAINTAING OF FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING OF POLE COMPLETE WITHOUT
COST OF NUTS & BOLTS, PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING
OF GUY SET AND EARTHING
(A) PSC POLE 8 MTR. LONG 200 KG . 250 NO. 1113
(B) PSC POLE 10 MTR LONG 270 KG 20 NO. 2466
(C) STEEL POLES OF 9 TO 11 MTR
(D)STEEL POLE OF 13 METER FOR RAILWAY
CROSSING ON BG/MG/NG LINE FOR 10 NO 2137
0.400/11/22 KV OVERHEAD LINES
ERECTION OF DOUBLE POLE STRUCTURE
INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING , FIXING OF
CHANNELS , SUPPORTING ANGLES , CLAMPS
,ANTI CLIMBING DEVICES ,DANGER BOARDS
INSULATORS ETC COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING OF POLE WITHOUT
COST OF NUTS & BOLTS, PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING
OF GUY SET AND EARTHING.(WITHOUT AB
(A) PSC POLE 8 MTR LONG AND 200 KG 10 NO. 2530
(B)PSC POLE 10 MTR LONG AND 200 KG 3 NO. 5320
(C)STEEL POLE 9 TO 11 MTR 3 NO 3655
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH , HG FUES
INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING , FIXING OF
CHANNELS , SUPPORTING ANGLES , CLAMPS
,ANTI CLIMBING DEVICES ,DANGER BOARDS
INSULATORS ,DO FUSES ETC COMPLETE
AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING OF
POLE WITHOUT COST OF NUTS & BOLTS,
PAINTS AS PER STANDARD SPECIFICATION
BUT EXCLUDING OF ERECTION OF GUY SET
AND EARTHING(WITH AB SWITCH)
(A) PSC POLE 8 MTR LONG AND 200 KG 5 NO 3042
(B) STEEL POLE 9 TO 11 MTR 3 NO 3990
(C) STEEL POLE OF 13 METER 3 NO 4531
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH , HG
FUES,TRANSFORMERS, LIGHTENING
ARRESTORS , DISTRIBUTION BOX ETC
INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING CARTING OF
TRANSFORMERS FROM STORE TO SITE,,
FIXING OF CHANNELS , SUPPORTING ANGLES
, BRANCING CROSS ARMS CLAMPS ,ANTI
CLIMBING DEVICES ,DANGER BOARDS
CONDUCTOR AND CABLE WIRING ETC
COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING OF POLE WITHOUT COST OF
NUTS & BOLTS, PAINTS AS PER STANDARD
SPECIFICATIONBUT EXCLUDING OF
ERECTION OF GUY SET AND EARTHING
(A) PSC POLE 8 MTR LONG AND 200 KG 75 NO 8681
(B)PSC POLE 10 MTR LONG AND 200 KG 5 NO 9808
(C) STEEL POLE 9 TO 11 MTR 3 NO 10151
ERECTION OF GUY SET INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH
AS PER STANDARD SPECIFICATION WITH
6 STAY CLAMPS , STAY WIRE , ANCHOR ROAD , 250 NO 537
TURN BUCKLE , EYE BOLT , GUY INSULATOR
CEMENT CONCRETE BLOCK ETC BUT
EXCLUDING CONCREATING WITHOUT COST
OF NUTS AND BOLTS
CONCRETING OF POLES , GUYS ,ETC.
7 INCLUDING COST OF CEMENT, SAND, METAL 3 CMT 7668
(1:2:4) AND WATER ETC. AS PER STANDARD
SPECIFICATION
ERECTION OF COIL TYPE / CI PLATE TYPE
8 EARTHING INCLUDING COST OF COAL, SALT 250 NO 579
ETC BUT WITHOUT COST OF NUTS &BOLTS,GI
WIRE AS PER STANDARD SPECIFICATION(10
KG SALT + 10 KG COAL).
STRINGING Of ALL TYPE CONDUCTOR CONDUC
(EXCEPT DOG CONDUCTOR) FOR 11/22 KV &
LT LINES INCLUDING FIXING OF INSULATORS, KM
BINDING JUMPERING ETC
PROVIDING GUARDING TO HT / LT LINE
ON ROAD / RAIL CROSSING WITHOUT COST
OF NUTS AND BOLTS.
LAYING OF OVERHEAD LT CABLE FOR ROAD
CROSSING,HT LINE CROSSING ROAD AND
TELEPONE LINE CROSSING ETC.(PER SPAN)
100 NUMBER 251
WITHOUT COST OF NUT &BOLTS,.JUSTI KHILA
STRINGING OF DOG CONDUCTOR ( 100 MM2 ONE
ACSR/100 MMM2 AAAC) FOR 11/22 K & LT LINE CONDUC
INCLUDING FIXING OF
INSULATORS,BINDINGG,JUMPERING ETC. KM
STRINGING OF LT ABC OF FOLLOWING SIZE
INCLUDING FITTING OF ALL ACESSORIES I.E.
SPECIAL DESIGN SUSPENSION/TENSION
CLAMP , FIXING CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF MESSENGER
13 WIRE AND TO PROVIDE SERVICE 10 KM 9208
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS
THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE EXCLIDING COST OF
ACESSORIES(1 X 35 MM2 + 1 X 25 MM2 , 1 X
MM2 + 1 X 35 MM2 OR ANY SIZE OF SINGLE
PHASE TWO WIRE LT AB CABLE)
STRINGING OF 11 KV ABC OF FOLLOWING
SIZE INCLUDING FITTING OF ALL
ACESSORIES I.E. SPECIAL DESIGN
SUSPENSION/TENSION CLAMP , FIXING
CROSS ARM,BINDING TO PIN
INSULATOR,PREPARING SHAKLE POINT 10 KM 43155
JUMPERS ETC.FOR FIXING OF MESSENGER
WIRE AS REQUIRED AND DIRECTED BY
ENGINEER IN CHARGE.(3 X 95 MM2 + 1 X
MM2 , 3 X 70 MM2 + 1 X 70 MM2 OR ANY SIZE
OF HT AB CABLE)
STRINGING OF LT ABC (3.5 CORE) OFF
FOLLOWING SIZE INCLUDING FITTING OF ALL
ACESSORIES I.E. SPECIAL DESIGN
SUSPENSION/TENSION CLAMP , FIXING
CROSS ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON AERIAL
14 BUNCHCABLE BY INSULATED PIERCEING 10 KM 23016
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED
& DIRECTED BY ENGINEER IN CHARGE
EXCLIDING COST OF ACESSORIES(3 X 50 MM2
+ 1 X 25 MM2 OR ANY SIZE OF LT 3.5 CORE AB
SELF TIGHTENING ANCHORING (DEADEND)
18 CLAMP CLAMP WITH POLE BRACKETUSING 35 NO 149
STAILNESS STEEL STRAP & BUCKLE
SELF LOCKING SUSPENSION CLAMP WITH
19 POLE BRACKET USING STAILNESS STEEL 35 NO 165
STRAP &BUCKLE
PRE INSULATED MID SPAN JOINTS FOR
20 PHASE & NEUTRAL FOR 16 SQ MM2 TO 50 35 NO 149
ERECTION OF SUPPORT POLE (PSC/STP/RSJ)
FOR STAY I.E. STUD POLE
REPLACEMENT OF DETERIOIRATED /
PROVIDING NEW LT DIST. BOX UP TO 100 KVA
22 CAPACITY WITH MAKING ALL CONNECTION 20 NO 1171
CRIMPING OF LUGS,NEUTRAL ETC.,&
CREDITING IT TO STORE
REPLACEMENT OF DETERIOIRATED /
PROVIDING NEW LT DIST. BOX ABOVE
23 KVA CAPACITY WITH MAKING ALL 20 NO 2107
CONNECTION CRIMPING OF LUGS,NEUTRAL
ETC.,& CREDITING IT TO STORE
DISMENTALLING OF TRANSFORMER CENTER(
8 MTR PSC POLE ) WITH CREDITING OF
FABRICATION &
TRANSFORMER AT STORE & STACKING OF
POLE AT SAFE LOCATION ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL
STORE(TRANSFORMER CREDITING TO
DEPARTMENTAL STORE ) POLE &
TRANSFORMER SHOULD BE IN CONDITION AS
DISMENTALLING OF TRANSFORMER CENTER(
8 MTR PSC POLE )( WITHOUT TRANSFORMER
) WITH CREDITING OF FABRICATION AT
STORE & STACKING OF POLE AT SAFE
LOCATION ON ROAD SIDEOR CREDITING TO
DEPARTMENTAL STORE
REMOVAL/DISMENTALLING OF EXISTING
HT/LT LINE (34 MM2 TO 55 MM2 SIZE
CONDUCTOR) AND CREDITING TO PER
26 STORE.CONDUCTOR HAS TO DISMENTAL 5 COND. 1010
FROM SHACKLE TO SHCKLE POLE, WITH PER KM
MINIMUM NOS. OF CUT PIECE AS
INSTRUCTION OF ENGINEER INCHARGE
REMOVAL/DISMENTALLING OF EXISTING
HT/LT LINE (ABOVE 55 MM2 SIZE
CONDUCTOR) AND CREDITING TO PER
27 STORE.CONDUCTOR HAS TO DISMENTAL 5 COND. 2326
FROM SHACKLE TO SHCKLE POLE, WITH PER KM
MINIMUM NOS. OF CUT PIECE AS
INSTRUCTION OF ENGINEER INCHARGE
CARTING OF PSC POLE AT DESTINATION
(PER POLE) MORE THAN 4 KM & UPTO
WORK DESTINATION
POLE BROKEN CHARGES IN EMERGENCY
SITUATION(NECESSARY APPROVAL TAKEN PER
BY THE (EE) DIVISION BEFOR APPROVE THE POLE
PAINTING/WRITING CONSUMER NO. ON
34 SMB/MMB (URBAN) (WITH LETTER SIZE 200 NO 11
HEIGHT 40MM * WIDTH 8MM)
PAINTING CONSUMER NO. ON MMB (RURAL)
35 (WITH LETTER SIZE HEIGHT 40MM * WIDTH 200 NO 21
RESTRINGING OF HT & LT LINE (34MM2 TO 1 WIRE
36 55MM2) CONDUCTOR/COATED CONDUCTOR 200 106
WITH NEW PIN BINDING PER SPAN
RESTRINGING OF HT & LT LINE (ABOVE
37 55MM2) CONDUCTOR/COATED CONDUCTOR 200 1 WIRE 106
WITH NEW PIN BINDING PER SPAN
RESTRINGING OF 11 KV ARIEAL BUNCH
38 CABLE (ALL SIZE) PER SPAN WITH LABOUR OF 50 PER 316
FITTING OF ACCESSORIES. SPAN
39 DISMANTLING OF 8 MTR PSC POLE IN USABLE 120 NO 562
CONDITION WITH CREDITING OF
FABRICATION AT STORE & STACKING OF
POLE AT SAFE LOCATION ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE.
REPLACEMENT OF 11KV PIN INSULATOR BY
40 NEW PIN INSULATOR/COMPOSITE PIN 200 NO 45
PIN BINDING OF CONDUCTOR WITH 11/22 KV
41 PIN INSULATOR AS PER INSTRUCTION OF 150 PER POLE 26.50
ENGINEER IN CHARGE.
PIN BINDING OF CONDUCTOR WITH LT
42 SHACKLE INSULATOR AS PER INSTRUCTION 150 PER POLE 24
OF ENGINEER IN CHARGE.
RE-JUMPERING OF HT/LT LINE FOR SHACKLE
200 PER POLE 94
REPLACEMENT OF 11KV DISC INSULATOR BY
44 NEW DISC INSULATOR/COMPOSITE DISC 200 NO 164
CONVERTING PIN POINT TO SHAKLE POINT
45 INCLUDING DISMENTALING & RESTRINGING
ETC,(INCLUDING COST OF NUTS AND BOLTS)
RE-TIGHTENING OF LOOSE GUY SET IN ALL
46 ASPECTS/ADJUSTMENT THE TENTION IN 250 NO 175
TRIMMING AND CUTTING OF BIGGER SIZE
TREE BRANCHES / WHOLE TREE PER
OBSTRUCTUING HT/LT LINE (DURING MASS
MAINTENANCE ACTIVITIES 8 HRS. DURATION)
TRIMMING AND CUTTING OF BIGGER SIZE
TREE BRANCHES / WHOLE TREE
OBSTRUCTUING HT/LT LINE (DURING LOCAL
50 PER DAY 375
MAINTENANCE ACTIVITIES)
CUTTING OF TREE BRANCHES OBSTRUCTING HT/LT
LINE ON ONE TREE(SIZE OF BRANCH ABOVE 6 INCH PER
DIAMETER) TREE
TRIMMING AND CUTTING OF TREE
BRANCHES OBSTRUCTUING HT/LT LINE WITH
50 MINIMUM 2 LABOURS WITH TREE CUTTING 10 PER DAY 3000
MACHINE & LADDER VEHICLE(DURING MASS
MAINTENANCE ACTIVITIES / DISASTER)
REPLACEMENT OF LT SHACKLE INSULATOR
BY NEW ONE.
REFIXING OF V CROSS ARM IN PROPER
REPLACEMENT OF V CROSS ARM BY NEW
ONEWITH PAINTING
RE-FIXING OF TOP FITTING IN PROPER
REPLACEMENT OF TOP FITTING BY NEW ONE.
STRAIGHTING OF TILLED PSC/RSJ POLE AT
STRAIGHTING OF TILLED PSC/RSJ POLE AT
TENSION POINT
NUMBERING OF POLE WITH PAINT BY
57 PREPARING BACK GROUNG OF ONE COLOUR 50 NO 50.50
AND HAVE LETTERING(HEIGHT 3” * WIDTH
0.5”) AS PER INSTRUCTION OF ENGINEER
INCHARGE (COLOUR MUST HAVE ISI MARK &
TO BE PROVIDED BY CONTRACTOR)
PAINTING OF STEEL/RSJ POLE 100*116 OF
TO 13 MTR (WITHOUT FABRICATION )BY TWO
COAT OF RED OXIDE, TWO COAT OF SILVER
COLOUR (APPROVED ISI MARK)
PAINTING OF ALL STEEL/MS FABRICATED
MATERIAL FITTED ON DOUBLE POLE
STRUCTURE PSC/RSJ POLE BY TWO COAT OF
RED OXIDE, TWO COAT OF SILVER COLOUR
(APPROVED ISI MARK)WITHOUT
X’MER.(EXCLUDING RSJ POLE)
PAINTING OF ALL STEEL/MS FABRICATED
MATERIAL FITTED ON DOUBLE POLE
STRUCTURE PSC/RSJ POLE WITH X’MERBY
TWO COAT OF RED OXIDE, TWO COAT OF
SILVER COLOUR (APPROVED ISI
MARK).(EXCLUDING RSJ POLE)
PAINTING OF STEEL/MS FABRICATED
MATERIAL OF PC/RSJ POLE ON HT LINE BY
TWO COAT OF RED OXIDE, TWO COAT OF
SILVER COLOUR.(APPROVED ISI MARK)
PAINTING OF STEEL/MS FABRICATED
MATERIAL OF PC/RSJ POLE ON HT POLE
62 EXTENSION ON HT LINE BY TWO COAT OF 10 NO 171
RED OXIDE, TWO COAT OF SILVER
COLOUR.(APPROVED ISI MARK)
PAINTING OF STEEL/MS FABRICATED
MATERIAL OF PC/RSJ POLE ON 4W LT LINE BY
TWO COAT OF RED OXIDE, TWO COAT OF
SILVER COLOUR.(APPROVED ISI MARK)
PAINTING OF STEEL/RSJ POLE 150*150 OF
TO 13 MTR WITHOUT FABRICATION BY TWO
COAT OF RED OXIDE, TWO COAT OF SILVER
COLOUR.(APPROVED ISI MARK)
DISMANTLING OF 10 MTR PSC POLE IN
USABLE CONDITION WITH CREDITING OF
65 FABRICATION AT STORE & STACKING OF 10 NO 1233
POLE AT SAFE LOCATION ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE.
ERECTION OF GI PIPE/CI PLATE TYPE
EARTHING INCLUDING COST OF COAL,SALT
ETC.BUT WITH OUT COST OF NUTS &
BOLTS,GI PIPE,CI PLATE ,GI WIRE AS PER
STANDARD SPECIFICATION(20 KG SALT +
PROVIDING MATERIAL FOR STRIP TYPE
EARTHING FOR TRANSFORMER CENTER AND
FIRST 20 POLES OF 11KV FEEDER:
(1)25*3 MM GI 90’ HOT DIP STRIP, TOTAL
LENGTH OF STRIP IS 9 MTRS WITH 4 METER
FROM G.I HOT SLEEVE INSULATION COATED
(2)300*300*10 MM CL EARTHING PLATE WITH
TWO NOS. HOLE FOR GI STRIP FITTING.
(3) STANDARD GAUGE 2’’ PVC PIPE 2 METER.
(4) NUT BOLT AS PER REQUIRED SIZE.
LABOUR WORK FOR GI INSULATED GI STRIP
EARTHING FOR BODY AND NEUTRAL OF
TRANSFORMER CENTER AND FIRST 20 POLES UNDER
THARAD DO FOR 11 KV FEEDERS.
SCOPE OF WORK:
(1)EACH EARTH TERMINAL SHALL BE PROVIDED BY
DIGGING A PIT OF 1800MM*1200MM. THE PIT
SHELL BE AT LEAST 1200MM FAR FROM THE
NEAREST SUPPORT. THE PIT WILL BE FILLED IN BY
ALTERNATE LAYERS OF WOOD CHARCOAL AND SALT
CUBES EACH OF 300MM TILL 1500MM FROM
BOTTOM OR WILL BE FILLED BETONIES POWDER,
REMAINING 300MM SHALL BE REFILLING BY DUG
(2)THE CONTRACTOR SHALL HAVE TO PROVIDE
WOOD CHARCOAL (25KG APPROX.) AND SALT
CUBES( 25KG APPROX.) OR BETONIES POWDER(50
KG APPROX.) HIS OWN.EARTHING SHOULD BE DONE
AS PER REC STANDARD & SPECIFICATION. EARTHING
VALUE MUSTBE LESS THAN 5 OHMS.
(3) STRIP IS TO BE FITTED WITH V CROSS ARM SIDE
CLAMP WITH BOLT AND GI WIRE FROM THERE TO
TOP FITTING WITH BOLT. EXPOSED PART OF STRIP
SHOULD BE PASSED THROUGH A RIGID PVC PIPE (2
METERS APPROX).
ERECTION OF STREET LIGHT FIXTURE
COMPLETE WITH CLAMPS BRASS
NIPPLE,BRASS HOLDER TECK WOOD
69 BUSH,REFLECTORS FUSE,WIRING ETC. WITH 10 NO 344
OUT COST OF NUTS & BOLTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS
ERECTION OF SINGLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG
FUSES,TRANSFORMERS,LA,DISTRIBUTION
BOX ON 8 MTRS 200 KG AND PSC POLES
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH,CARTING OF
70 TRANSFORMERS FROM STORE TO 10 NO 4340
SITE,FIXING OF CHANNELS,SUPPORTING
ANGLES,BRACINGS CROSS ARMS
CLAMPS,ANTICLIMBING DEVICES,DANGER
BOARDS,CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING OF POLES WITHOUT COST
OF NUTS & BOLTS, PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.
STAINLESS STEEL OF SIZE STRAP 20 MM *0.7
MM & BUCKLE WIDTH 20 MM
LABOUR CHARGES FOR FIXING OF END
PROVIDING AND FIXING OF OUTDOOR CABLE
73 JOINING KIT SUITABLE FOR 3C X 5 NO 5982
120/150/185/240/300 SQ.MM. 11 KV PILC CABLE
PROVIDING AND FIXING OF STRAIGHT JOINT
SUITABLEFOR OUTDOOR END TERMINATION
XLPE CABLE
LABOUR CHARGES FOR FIXING HEAT
SHRINKABLE TYPE CABLE JOINT FOR 11 KV
1C*70 SQ.MM./1C*95 SQ.MM. AB CABLE (1
LABOUR CHARGES FOR FIXING HEAT
SHRINKABLE TYPE CABLE JOINT FOR 11 KV
1C*70 SQ.MM./1C*95 SQ.MM. AB CABLE
INCLUDING RESTRINGING OF HT AB CABLE
PROVIDING & FIXING HEAT SHRINKABLE
77 TYPE CABLE JOINING KIT SUITABLE FOR 11 15 NO 3100
KV 3C* 70 SQ.MM./3C*95 SQ.MM. AB CABLE
FOR OUTDOOR TERMINATION
Note: The rates are exclusive of nut bolt and GST. UGVCL will supply the required nut-bolts. If not supplied by
UGVCL THEN Rs.103.33 per KG with GST provided. THIS ERECTION WORK ORDER TO BE TRANSFER IN ANY
SUBDIVISION UNDER THARAD DO AS PER REQUIREMENT AND INSTRUCTION OF EE THARAD.(AS PER COST
Amount Without GST 36,11,385.00/-
WELFARE CESS ESTIMATED COST @ 1% 36,113.85/-
A Total Rs. 43,04,048.64/-
B Bidder’s Offer (+ / -) in %
C Grand Total = A +/- (A x B)
C Grand Total = A +/- (A x B)
D SAC Code:
E Final Offer (in Rs.):
F Final Offer (in Words):
The rates quoted are_______% above/bellow to the scheduled rates as shown in SCHEDULE-B above.
Thus, my tender value is Rs. __________________ (in words Rs.________________________)
Above mentioned rate is inclusive / exclusive of 1% Welfare Cess& 18 % GST.
SIGNATURE OF CONTRACTOR EXECUTIVE ENGINEER
WITH SEAL UGVCL, THARAD DO
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SNR 05 THARAD-DO-02-2026-27(ERECTION WAV).pdf
SNR 05 SCHEDULE-B.pdf
Download all tender documents and submit your bid