SO(ENM)
GM UNIT KUJU
Rewiring/Repairing of 11no. of C type qtr situated in the tripple story building along with external wiring of same building and 01 no. of LCH qtr situated at Datma more colony of GM Unit under Kuju Area.
2024_CCL_317312_1
GM (K)/EnM/eTender/24-25/138
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹17,600
22 Oct 2024
11 Sept 2024
23 Sept 2024
11 Sept 2024
21 Sept 2024
11 Sept 2024
11 Sept 2024 - 18 Sept 2024
Amount
Supplying & drawing/laying of PVC insulated XLPE aerial bunch power cable conductor H2/H4 grade aluminium solid/stranded conforming to IS.142551995, alu alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below -3x35 sq. min, 1x16(st. light). 1x35(insulated neutral messenger) 142551995, alu alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below -3x35 sq. min, 1x16(st. light). 1x35(insulated neutral messenger)
Supply and fixing surface mounting LED dovin lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with miniinum L 70, system lumen output should be minimum with efficacy>100 Im/Watt. LED driver PF>0.95, THD < 20% & Surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glaro free diffused polycarbonate cover. Submission LM 7908/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job..21/22/24Watt, color tomp 3000-6500k as required.
Supplying and fixing of hot water storage water heatervertical with required safety, ABS body including connection pipe, foundation bolt and nut. connection pipe, stop cock, tosting etc. to complete the job 15 Ltr. (5 Star rating-standing losses 50.419 kWh/24 hrs/45°C)
Supply and fixing Led tube rod comprising of LED tuhe with nonintegral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum L 70, system lumen output should be minimum with system efficacy> 100 Im/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering Index of LED light should he more than 70. Submission LM 79- 08/516105 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job Tube light LED 1 X 18Watt, Integral i/c batten aluminiuin body, PC dilluser.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.min FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and carthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. Group(A)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with nodular switch, modular plate, suitable Gl box and carthing the point with 1.5 sq.inm FRLS PVC insulated copper conductor single core cable etc. as required.. Group(B)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc, as required
Wiring for circuit/ submain wiring alongwith carth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm carth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRI.S PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requirea.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRI.S PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requirea.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply and drawing following size of FRLS PVC insulated copper conductor / single core cable in the existing surface recessed steel / PVC conduit as required 2*6sq mm
Supplying and fixing following plano type switch socket on the existing switch box/ cover including connections etc. as required.
a)5/6 Amp Switch
b) 3 pin 5/6 amp sacket outlet
c) Pin 15/16 Amp Socket outlet
d)15/15 amp switch
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, elc, as required. 200A ΤΡΝ
Supplying and fixing of 200A wall mounted bus bar Gway 4 pole, 415v
Supplying and fixing of main switch 32A, 240V, SMDP
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plato having locking arrangement and watering pipe of 2.7 metre long etc. witli charcoal/ coko and salt as required
Supplying and fixing following way, single pole and neutral, sheet stool, MCB distribution beard, 240 V, on surface/recess, complete with tinned capper bus bar. neutral bus bar, earth bar, din bar, Interconnections, powder painted Including earthing etc, as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40A
Supplying and fixing following way, single pole and neutral, shoet steel, MCB mistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing eic, as required. (But without MCB/RCCB/Isolator)16 way, Double door
Supply and fixing as per specification call bell/ buzzer of approved make with necessary materials complete Multi sound bell
Supply and fixing street light with high power LED of 3 to 6 Watt cach on existing bracket assembled on single MCPCB and Jadditional unique peanut lens on each LED, system lumens output with efficacy>120 Im/Watt. luminiare having color teinp uplo 6500K & 50000 hrs. burning life with minimum @L 70, The colcur rendering Index of LED light should be more than 70. Lurniniare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure dio cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347 ilc connection wire, testing etc. to complete the job 90Watt, color tomp 3000-6500k as required.
Total impact of GST for the purpose of CTC
M/S SANTOSH ELECTRIC
M/S VAISHALI ELECTRIC COMPANY
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .