Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹27.0 LAdmitted-Finance K 223 SITE V KASNA UPSIDA INDUSTRIAL AREA GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201310 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201310 | L1 | Admitted-Finance | ||
| 2 | L2₹31.4 L+₹4.4 L (16.3%)Admitted-Finance 205 2ND FLOOR VARDHMAN CHAMBER LL 0 VIKASPURI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Admitted-Finance | ||
| 3 | L3₹32.5 L+₹5.4 L (20.1%)Admitted-Finance 1ST FLOOR B 3 111 9 YASHIKA APARTMENT KISHAN GARH VASANT KUNJ NEW DELHI 110070 | NEW DELHI | DELHI | 110070 | L3 | Admitted-Finance | ||
| 4 | L4₹34.6 L+₹7.6 L (28.1%)Admitted-Finance 0 DOGRA CHOWK JEWEL JAMMU JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L4 | Admitted-Finance | ||
| 5 | L5₹35.7 L+₹8.7 L (32.2%)Admitted-Finance | L5 | Admitted-Finance |
Tender Value
₹36.8 L
EMD Value
₹73,669
Closing Date
13 Oct 2026, 3:00 pmClosed
Executive Engineer (E)
O/o The Executive Engineer (E) South Elect. Div., PWD, Sukhdev Vihar, Mathura Road, Near Okhla Flyover,New Delhi
Replacement of 2 Nos. 13 Passenger lift at Delhi Archive, Qutab Institutional Area, New Delhi.
2026_PWD_299603_1
84/EE(E)/EMD South Elect. Divn./PWD/2026-27
Open Tender
Electrical Works
Works
180 days
New Delhi
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹73,669
Yes
16 Oct 2026
7 Oct 2026
13 Oct 2026
7 Oct 2026
13 Oct 2026
7 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- | |||||
| 1.01 | (i) Speed-1 MPS
(ii) Floors-5 (G+4)
(iii) Travel -17 Meters (approx.)
(iv) Stops & opening- 5 stops and 5 openings
(v) Controller: A.C. variable voltage & variable frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.
vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
(xi) Type of doors
(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.
(xiii) Voice announcement system in the car to | - | - | - | - |
| 1.02 | announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility,
tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.
(xvi) An appropriate technological support be provided (Through
emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided | - | - | - | - |
| 1.03 | 13 passenger (884kg) | 2 | Each | 16,84,225.72 | ₹33,68,451.44 |
| 2 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | 4 | Sets | 7,658 | ₹30,632 |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 480 | Mtr. | 50 | ₹24,000 |
| 4 | Supplying, Laying and fixing following size of PVC insulated and PVC sheathed al. conductor armoured power cable of 1.1 KV grade of following ways as reqd.
(a) 3.5 X 50 sq.mm. cable cable on surface | 225 | Mtr. | 984 | ₹2,21,400 |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
(a) 3½ X 50 sq. mm (35 mm) | 8 | Each | 484 | ₹3,872 |
| 6 | Pdg. and fixing of floor mounting compartmentalized cubical panel board minimum 400 mm depth with locking arrangement front openable, totally enclosed, dust & vermin proof fabricated out of 2mm thick cold rolled carbon annealed, sheet steel, with suitable incoming Amp 4 strip Al. bus bar, cable alley on both sides, powder coated paint of approved shade and 2 nos 25x5mm copper strips throughout the width of panel consisting of two earth studs on each strip complete with following incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing 50mm X 50mm X 6 mm thick Angle base upto 300 mm above ground level including necessary grouting / fixing on floor ( Drawing shall be got approved from Engineer-in-charge before fabrication(all MCCB's shall have spreader link & rotory handle) complete etc as required | 1.1 | Sq.mtr. | 25,000 | ₹27,500 |
| 7Supply & fixing of following accessories in the existing cubical type M.S. panel board i/c drilling holes in cubical panel, making connections etc as reqd. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.09 MB
BOQ_399868.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .