Divisional Engineer-(Electrical), Tirumala
Line Inspector
AME and major spare parts to Sanku, Chakram and Namam available at Galigopuram (Alipiri footpath) and HVC area in ESD-South,Tirumala for 2026-27
974372
179/DE(Elec)Tml/TTD/2026-27
OPEN - NCB
Electrical Works
TIRUPATHI
7 documents required · 7 mandatory
₹298
₹21,100
4 Sept 2026
7 Aug 2026
7 Aug 2026
Annual maintenance contract for LED Display board of Sanku, Chakram & Namam at Gali gopuram and HVC area, Tirumala.
scope of work: 1)12 technical visits in a year attending for repairs and servicing of LED Dispaly board. 2) All Emergency calls should be attend with in 48 hours and rectify the defect. 3) Replacement of defective LED Drivers and SPD. 4) Replacement of defective wires and cables. 5) Service reports should be send to concern AEE/AE soon after every service. 6) Payment will be made on quarterly basis.
Supply & erection of 12V, 60W Tetra LED systems Power Supply drivers. Make: GE/Meanwell Model :GE12-60U-GL/XLG-75-12
LED Driver Technical specification: • Product Code: GEPS12-60U-GL • Casing: Metal • IP: IP66(separate enclosure required)/ No required separate enclosure required) • Secondary protection: Yes
Input voltage surge protection : Yes • Over temperature protection: Yes • Short circuit protection: Automatic,reversible • Overload protection: Automatic, reversible • Over temperature protection: Automatic, reversible • Power loss @ full load: 9W max / No Data in Data Sheet. • PSU efficiency >0.86 / 0.68 • Case temperature [°C]: 85°C / 90°C • Performance data :PSU life time: 5 years • Safety:IEC:61347-1, IEC:61347-2-13, UUL1310 / EN61000-4-3:EN61000- 4.4:EN61000-4-5: EN61000-4-6:EN61000- 4-8:EN61000-4-11. • Performance: IEC: 60529 (IP rating), ANSI / IEEE C62.41-2005, EN61000-4-5:2006 / EN55015(CISPR15), GB/T17743,EN55015 (CISPR15),GB/T17743,EN61000-3-2, GB/ T17625.1
• Harmonic content: IEC 61000-3-2 / EN61000-3-2,GB/T17625.1 • Electrical data :Input voltage range:108- 305V • Input frequency: 50/60 Hz • Input current: 650 mA / 450 mA • Power factor : >0.9 / >0.95 • Output voltage: 12V • Output voltage range: 11V to 13V • Nominal power [W]: 60 • Nominal lamp voltage [V]: 230 • Power loss in no load condition : 7W • Inrush current: (Remark): 27A/0.23ms @ 120V; 54A/0.24ms @ 230V; 59A/ 0.25ms @ 277V Surge / 50A/300uS @230v • Surge capability: L-N, L-G, N-G, L+N- G:3kV / 4kV L+N-G:6kV
Supply of ……...ISI marked, PVC insulated and sheathed FRLS/FRLS-H round copper cable for voltage up to 1100V as per IS 694/1990. Makes: As per list of recommended brands as category I Makes:Finolex/RR kabel/Havells/KEI/Polycab/Gloster/Goldmedal /GM /Finecab/Fortune Arrt/ Anchor/Million.
3 core, 2.5 Sq mm
3 core 4.0 Sqmm
Supply of LED Bulbs Strip in place of existing damaged LED's.
Supply of 3mm ACP in place of damaged sheet in Sanku Namamu boards.
Note:- (1)The work including replacing the damaged sheets, Driver, ACP sheet, LED strips etc., as one work for entire Sanku, Chakra and Namam board. (2)The agency have to select the materials on par with the existing materials hence the tenderer is requested to inspect the site before tender so as to have unform lighting. (3)The materials are to be guaranteed for one year (Excluding natural calamities). (4)The required ladders, Welding, Labour is included. (5)The removed materials have to be taken up by the tenderer / Contractor after completing the work.
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
Annual maintenance contract for LED Display board of Sanku, Chakram & Namam at Gali gopuram and HVC area, Tirumala.
scope of work: 1)12 technical visits in a year attending for repairs and servicing of LED Dispaly board. 2) All Emergency calls should be attend with in 48 hours and rectify the defect. 3) Replacement of defective LED Drivers and SPD. 4) Replacement of defective wires and cables. 5) Service reports should be send to concern AEE/AE soon after every service. 6) Payment will be made on quarterly basis.
Supply & erection of 12V, 60W Tetra LED systems Power Supply drivers. Make: GE/Meanwell Model :GE12-60U-GL/XLG-75-12
LED Driver Technical specification: • Product Code: GEPS12-60U-GL • Casing: Metal • IP: IP66(separate enclosure required)/ No required separate enclosure required) • Secondary protection: Yes
Input voltage surge protection : Yes • Over temperature protection: Yes • Short circuit protection: Automatic,reversible • Overload protection: Automatic, reversible • Over temperature protection: Automatic, reversible • Power loss @ full load: 9W max / No Data in Data Sheet. • PSU efficiency >0.86 / 0.68 • Case temperature [°C]: 85°C / 90°C • Performance data :PSU life time: 5 years • Safety:IEC:61347-1, IEC:61347-2-13, UUL1310 / EN61000-4-3:EN61000- 4.4:EN61000-4-5: EN61000-4-6:EN61000- 4-8:EN61000-4-11. • Performance: IEC: 60529 (IP rating), ANSI / IEEE C62.41-2005, EN61000-4-5:2006 / EN55015(CISPR15), GB/T17743,EN55015 (CISPR15),GB/T17743,EN61000-3-2, GB/ T17625.1
• Harmonic content: IEC 61000-3-2 / EN61000-3-2,GB/T17625.1 • Electrical data :Input voltage range:108- 305V • Input frequency: 50/60 Hz • Input current: 650 mA / 450 mA • Power factor : >0.9 / >0.95 • Output voltage: 12V • Output voltage range: 11V to 13V • Nominal power [W]: 60 • Nominal lamp voltage [V]: 230 • Power loss in no load condition : 7W • Inrush current: (Remark): 27A/0.23ms @ 120V; 54A/0.24ms @ 230V; 59A/ 0.25ms @ 277V Surge / 50A/300uS @230v • Surge capability: L-N, L-G, N-G, L+N- G:3kV / 4kV L+N-G:6kV
Supply of ……...ISI marked, PVC insulated and sheathed FRLS/FRLS-H round copper cable for voltage up to 1100V as per IS 694/1990. Makes: As per list of recommended brands as category I Makes:Finolex/RR kabel/Havells/KEI/Polycab/Gloster/Goldmedal /GM /Finecab/Fortune Arrt/ Anchor/Million.
3 core, 2.5 Sq mm
3 core 4.0 Sqmm
Supply of LED Bulbs Strip in place of existing damaged LED's.
Supply of 3mm ACP in place of damaged sheet in Sanku Namamu boards.
Note:- (1)The work including replacing the damaged sheets, Driver, ACP sheet, LED strips etc., as one work for entire Sanku, Chakra and Namam board. (2)The agency have to select the materials on par with the existing materials hence the tenderer is requested to inspect the site before tender so as to have unform lighting. (3)The materials are to be guaranteed for one year (Excluding natural calamities). (4)The required ladders, Welding, Labour is included. (5)The removed materials have to be taken up by the tenderer / Contractor after completing the work.
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
(Rupees Eight lakhs forty one thousand two hundred and sixty six only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ 179.xls
TENDER_DOCUMENT • 2.01 MB
NIT 179.docx
TENDER_DOCUMENT • 0.18 MB
NIT 179.xlsx
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .