Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹26.0 L+₹2.0 L (8.52%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
6 Dec 2022, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
COMPREHENSIVE MAINTENANCE OF AC PLANT, FIRE FIGHTING EQUIPMENT AT DEAL IRDE FIRE FIGHTING SYSTEM FOR TECH A B AREA AT DEAL IRDE AND DG SETS, PANEL AND STABILIZERS IN TECH AND RESIDENTIAL AREA OF DEAL AND IRDE UNDER GE(I) RND DEHRADUN
2022_MES_563228_1
GE(I)RND/9206/E8/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEAL DEHRADUN
Class D Category c (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹66,000
Yes
4 Jan 2023
15 Nov 2022
8 Dec 2022
15 Nov 2022
6 Dec 2022
22 Nov 2022
15 Nov 2022 - 22 Nov 2022
Amount
Material and labour for Descaling of condenser unit by rubbing with nylon brush/ cleaning rod using hydrochloric acid pumped through electric driver descaling pump including dismantling and connecting all dismantled components in proper position after servicing/ overhauling/ greasing etc replacement of packing gasket 3mm thick, nuts, bolts with washer, testing of water line for leakage & repairing of pipe line to make it leak proof complete, all as specified and directedEngr-in-Chagre for the following AC plants :- Notes : (i) The de-scaling & cleaning of condenser (Heat Exchanger) of cooling tower shall be done by circulating concentrated de-scaling solution mixed with water of make as approved to the entire satisfaction of GE/Engineer-in-Charge complete all as specified in Sch ‘A’. (ii)The hydrochloric acid shall be used as a de-scaling solution mixed with water in a suitable proportion as approved by the GE/Engineer-in-Charge so as avoid damage to existing pipe lines.
11 TR capacity AC Plant Package Type(installed at Mechanical Lab Technical Area. IRDE)
45 TR capacity AC Plant (installed at Large Optics Building IRDE)
65 TR capacity AC Plant (installed at MMG / Optics Building IRDE)
80 TR capacity AC plant (installed at Photonic Buildling IRDE).
Dismantling the head from compressor fitted in system, and strip opening of compressor head of eight cylinder for Model 1WCDR0800MAS Make of Voltas, compressor completely for servicing /overhauling mechanically and electrically, and checking of various components with precision instruments to assess the requirements of repair/replacement, and making inventories for repairs required and re-fixing the serviceable parts in position after proper cleaning, oiling/greasing,etc ,and removing & replacement of defective / unserviceable parts with new parts, as required at site, and reassembling the compressors head ensuring perfectly leak proof after cleaning the oil sump, oil pump connecting rod, piston, liner etc and filling of compressor oil, before charging of refrigerant gas to required pressure and testing at site on full load to the entire satisfaction complete all as specified and directed for following :- (included notes mentioned in here in after) Notes: - (i) The replacement of defective / nonfunctional parts, and Refrigerant gas and compressor oil for top up shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing/filling rate for new items are deemed to include under these items. (ii) The refregrent gas to be pumped down before dismantlling the compressure head for avoid the wastage of gas. (iii) The quoted rate shall be deemed to include replacement of small/ minor parts for prroper functioning of compressure .
M&L for cutting and grinding the crank-shaft ( Model WCDR0800MAS Make of Voltas compressor) of 0.50/0.75 mm around as required to make it equivalent to manufacturer’s standard size and smoothening/ fine finishing,polishing of shaft to match with half section big end bearings, cleaning oil ports for proper lubrication complete all as specified and directed by . Note : (i) The cost of taking out and re-fixing of the shaft / rod in position after necessary repairs is deemed to be included under the rates quoted by the contractor for respective Schedule `A' item. (ii) The rates for above items are deemed to include transportation to & fro of crank-shaft to workshop for necessary repairs.
Supply only following items / spare parts suitable for Compressure Model of WCDR0800MAS Make of Voltas, dismantled / fixed under Sch ‘A’ item No.3 here in above complete all as specified and directed
Cylinder liner
Piston Bare
Compression ring set
Piston pin/ gudgen pin
Circlip internal
Connecting rod -05mm
Suction valve 'o' ring
Suction & Discharge valve spring
Discharge valve assembly
Safety plate
Shaft seal assembly
Paper filter
Center Bearing
Suction filter with nut
Oil pump with ring set
Set of gasket
Main bearing .05 mm.
Oil filter
Loading coil
Coupling Set
Carrying out leak detection in the system of AC plants including nitrogen pressure testing for 24 hours and repairing the leakage by gas welding / electric welding of refrigerant pipes, replacement of valve gland, gaskets etc. and then creating vacuum for 4 hours before charging refrigerant gas R-134 A/ R 410 in the system and testing the complete plant for working pressure for 24 hours complete, all as specified and directed. Note : R-134 A/ R 410 gas shall be measured and paid separately under Schedule ‘A’ Item.
11TR capacity AC Plant Package Type(installed at Mechanical Lab Technical Area. IRDE)
45 TR capacity AC Plant (installed at Large Optics Building IRDE)
65 TR capacity AC Plant (installed at MMG / Optics Building IRDE)
80 TR capacity AC plant (installed at Photonic Buildling IRDE).
Supply, fixing, connecting and testing in replacement of UNSV strip heater fins type, 3.0 KW, 230 volts, single phase, AC supply in any position complete, all as specified and directed.
Supply of refrigerant gas monochloro difluoro methane (CHCLF2) R- 22 conforming to IS-5160 of 1983 , duly filled in factory sealed cylinder standard capacity for filling under Sch ‘A’ item No 2. and here in above complete, all as specified and directed.
Supply only R-134A refrigrant gas with testingn under Sch ‘A’ item 3 here in above complete, all as specified and directed.
Supply only R-410 refrigrant gas with testingn under Sch ‘A’ item complete, all as specified and directed.
Supply of lubricating oil anti freezing for refrigeration in factory sealed container of standard capacity for filling under Sch ‘A’ items No 3 complete,all as specified and directed. Make: Servo froze -68-10c of IOC.
Supply fixing and testing in replacement of UNSV pre filter with GI sheet frame of size 610mm x 610mm x 50mm deep suitable for Air handling units of air conditioning plants including efficiency 90% , down to 10-20microns, Initial Pressure drop- 2.5 mm WG, filter media shall be Synthetic Non Woven with Both Side HDPE Mesh, and testing complete complete, all as specified and directed.
Supply fixing and testing in replacement of UNSV condencer safety valve of size 3/4"& ½”, for pressure 300 PSI with and Including 3/4"& ½”, mild steel socket duly welded on condenser ensuring perfectly leak proof joint with pressure testing complete all as specified and directed.
Supply fixing and testing in replacement of UNSV thermostatic expansion valve (R-22) suitable for 80 TR capacity of central AC plant complete, all as specified and directed.
Supply fixing and testing in replacement of UNSV water pressure gauge 100 mm dia of range 0 to 100 PSI suitable for central AC plant complete all as specified & directed.
Supply fixing and testing in replacement of UNSV Gas pressure gauge 100 mm dia of range 0 to 300 PSI suitable for central AC plant complete all as specified & directed.
Supply fixing and testing in replacement of UNSV Water flow switch for condenser and chiller suitable as per existing AC Plant Make :Carrior (Screw Chiller Unit) complete, all as specified and directed
Supply fixing and testing in replacement of UNSV sensor for low pressure/High Pressure/Oil Pressure switch suitable for as per existing suitable for AC Plant Make :Carrior (Screw Chiller Unit) complete, all as specified and directed
Supply fixing and testing in replacement of UNSV Loading/ unloading coil suitable for as per existing AC Plant. Make :Carrior (Screw Chiller Unit) complete, all as specified and directed
Supply fixing and testing in replacement of UNSV PVC Fills of FPR cooling tower size 600mmx300mmx 150 mm complete, all as specified and directed
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for compressor/blowers/pumps/ cooling towers and dismantling and strip opening of the motor, for cleaning oiling/greasing and fixing of serviceable parts in position and removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering compressor /blowers /pumps / cooling towers and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .
5.0 HP capacity, Three phase 50 Hz AC supply
7.5 HP capacity, Three phase 50 Hz AC supply
10 HP capacity, Three phase 50 Hz AC supply
15 HP capacity, Three phase 50 Hz AC supply
Disconnecting and removing old existing non functional electric motor, of any description and in any position from existing platform for pumps and dismantling and strip opening of the motor, for cleaning oiling/greasing, Replaceing UNSV suitable size of bearing and fixing of bearing, imppler serviceable parts in position pumps and transportation to site & refixing on existing platform ,connecting with exising connections & testing on full load complete all as specified and directed for following capacity :- .
5.0 HP capacity, Three phase 50 Hz AC supply
7.5 HP capacity, Three phase 50 Hz AC supply
10 HP capacity, Three phase 50 Hz AC supply
15 HP capacity, Three phase 50 Hz AC supply
Supply fixing,connecting and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 16 Amps complete all as specified and directed .Make L&T or equievelent model of specified and directed.
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 25 Amps complete all as specified and directed .Make L&T or equievelent model of specified and directed.
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 32 Amps. Complete all as specified and directed . Cat part No SS90935- Type ML-10 of make L&T or equievelent model of specified and directed. ,
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 50 Amps. Complete all as specified and directed .Make L&T or equievelent model of specified and directed. .
Supply fixing and testing in replacement of UNSV 3 pole Power contactor with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC3 rating 70 Amps. Complete all as specified and directed .Make L&T or equievelent model of specified & directed
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 06 to 18 Amps complete all as specified and directed. make L&T or equievelent model of specified and directed. .
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 19 to 30 Amps complete all as specified and directed. make L&T or equievelent model of specified and directed.
Supply fixing and testing in replacement of UNSV bimetal overload relays directly operated & directly mounted on ML type Power contactor for relay range of 32 to 45 Amps complete all as specified and directed. make L&T or equievelent model of specified and directed.
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Volt meter 0- 500 Volts including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.
Supply fixing and testing in replacement of UNSV digital type of size 96mm x 96mm, AC Amp meter 0- 200 Amps with including 3 Nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified and directed.
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 100 amps rating including testing complete, all as specified and directed
Supply fixing and testing in replacement of UNSV insulated connectors 4 pole 63 amps rating including testing complete, all as specified and directed
Supply fixing and testing in replacement of UNSV Electronic timers 415 Volts, 50 Hz, AC supply, with delay period of 9-30-Seconds complete all as specified and directed f make L&T or equievelent model of specified make as approved by the GE
Supply fixing and testing in replacement of UNSV push button ON/OFF complete in the existing panel Complete connecting electrically all as specified and directed
Supply fixing and testing in replacement of UNSV indicator light red/yellow /green complete in the existing panel Complete connecting electrically all as specified and directed
Supply, fixing, connecting and testing in replacement of UNSV thermostate heating/cooling of any description complete,all as specified and directed.
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 250 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete all as specified and directed. Make : L&T /INDO ASIAN/Havells
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 200 Amps 415 volts, 50 Hz having breaking capacity 36 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells
Supply, fixing, connecting and testing in replacement of UNSV MCCB Triple pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal and fixed magnetic setting fixed in existing panel Complete, all as specified and directed. Make : L&T /INDO ASIAN/Havells
Rectification of BMS ( Building management system) including existing software testing, controller/Server & Sensors Testing work at site complete,all as specified and directed by .( installed at Large Optics Building)
Supply, fixing, connecting and testing in replacement of UNSV Honeywell CN7510A2001 valve actuator suitable for existing air cooled air conditioner plant 45 TR complete, all as specified and directed.(Installed at Large Optics Building )
Disconnecting and removing the water and electric connections carefully & Dismantling and taking out the existing electric driven Multistage Spilt casing type pump set with 79HP/85HP/105HP, at 1500 rpm Diesel Engine (kilrloskar make) coupled with Pump having discharge at 88 mtr head model; HB60-20 from suction and delivery pipe lines transporting the pumpset to a Authoried Workshop for reconditioning of motor,Pump and change of parts in water pump Set including fitting of mechanical seal, Replacement of flexible coupling parts and alignment of pump and motor and thorugh servicing, greasing and oiling to the pump and motor, varnishing to the motor winding including other minor work required, re-assembling the pump and Engine, transportiang the same to its orginal location, fixing in position, connecting up electrical and pipe line connection, testing and commisssionig Commissioning of pump set for satisfactory operation on its full load complete all as specified and directed.
Disconnecting and removing the water and electric connections carefully & dismantling and taking out the Existing Multistage pump Spil casting set of capacity up 60HP/75 HP, Head-88 mtr, 1500rpm from base frame including disconnection suction and delivery pipes and shifting to workshop for repair. Dismentling of pump and motor.Varnishing to the motor winding,overhaluing complete after through cleaning all parts of motor by kerocene oil including material and labour of replacement worn out parts it required i.e. CI implellers, CI sleeves, CI bush/bearing, MS coupling with rubber tyre/ star type CI neck ring CI center stage ring, Ball bearing DE & NDE, stud nut, bolt, washer& body packing gasket of pump with necessary welding machine/ grinding work if required for repair of shaft/ pump body & .re-assembling pump on base frame with proper alignment with motor including re-shifting to the same to its orginal location, fixing in position, connecting up electrical and pipe line connection, testing and commisssionig of pump set for satisfactory operation on its full load complete all as specified and directed.
Disconnecting and removing the water and electric connections carefully & dismantling and taking out the Existing Multistage pump Spil casting set of capacity 11kw/ 15 HP from base frame including disconnection suction and delivery pipes and shifting to workshop for repair. Dismentling of pump and motor.Varnishing to the motor winding,overhaluing complete after through cleaning all parts of motor by kerocene oil including material and labour of replacement worn out parts it required i.e. CI implellers, CI sleeves, CI bush/bearing, MS coupling with rubber tyre/ star type CI neck ring CI center stage ring, Ball bearing DE & NDE, stud nut, bolt, washer& body packing gasket of pump with necessary welding machine/ grinding work if required for repair of shaft/ pump body & .re-assembling pump on base frame with proper alignment with motor including re-shifting to the same to its orginal location, fixing in position, connecting up electrical and pipe line connection, testing and commisssionig of pump set for satisfactory operation on its full load complete all as specified and directed. Note: - FOR ITEM No. 52, 53 & 54:- (i) Contractor shall take proper precautions while lifting out and removing Diesel Engine along with water pump set and acecssories from existing location well so as to avoid any damage . All necessary T&P and equipments required for dismental of the same arranged by the contractor at his own cost. (ii) Expendable stores like cotton waste/cleaning materials lubricants , gland packing metal filling, machinaing and transportation to and fro from site to work shop are deemed to be included in rate quoted. (iii) Minor spares Part required for repair the pump sets,motor,MS pipe,MS Nut, botls, washers ,rubber gasket joints etc and are deemed to be included in rate quoted. (vi) The rates for above items are deemed to include transportation to & fro of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop. (v) The rate quoted for the item shall include re-metaling of Pump shaft, polishing and grinding and making standard size to match with Gun Metal Bush/Neck-ring. (vi) The quoted rate shall be deemed to include replacement of small/ minor parts i.e. washers, keys for coupling, cable packing ring etc. (vii)Labour elemetns is included in unit rates.
Disconnecting,removing the water ,electric connections and taking out carefully the old existing defective electric motor, 05 HP of centrifugal pump of any description and in any position, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 5 HP, operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering multistage booster pumps/ centrifugal pumps & testing at workshop and transportation to site & refixing on existing platform complete, all as specified and directed .
All as per item No. 55 here in above but motor of capacity 15.0 HP complete, all as specified and directed .
Disconnecting, removing the water, electric connections and taking out carefully defective centrifugal pump of capacity 5 HP, DSM model of Make Kirloskar,, three phase, 415 V, AC supply and carrying out necessary repairs and replacement of bearing bush, gland plate, impeller, nuts and bolts etc, any trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete all as specified and directed.
All as per item No. 57 here-in- before but booster pump / centrifugal pump of capacity 15 HP complete all as specified and directed.
Supply only the following items/spare parts suitable for centrigugal pump of capacity 05/10 HP dismantled/fixed under Sch `A` item No 57 and 58 here in above complete all as specified and directed.
CI impeller as per existing size
MS stud with nut for split body complete size as per sample
Ball bearing for driving and non driving end.
CI sleeve of DE / NDE
CI/MS gland packing plate
CI bush (stuffing box bush)
Pump shaft EN8 complete including making key groove with check nut
Set of key with nut & washer
Replacement of packing sheet
Supply, installation, testing and commissioning in replacement of UNSV Single headed Stainless Steel fire hydrant landing valve type A (single head outlet) of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with couplings conforming to IS 903 all as specified and directed by .
Supply, installation, testing and commissioning in replacement of UNSV weather proof standard fire hose box made of 16 SWG gauge MS Sheet 750mm x 600mm x 250mm with double door with 4mm thick glasses and door frame including locking arrangement by allen key, stove enamelled fire red finish with 'Fire hose' marked on front and brilliant white inside yard, suitable for housing of and consisting of 2 lengths RRL hose pipe conforming to IS:636-1979 (type-II) of 63mm dia. GM instataneous male and female coupling (IS:903) and branch pipe and nozzel 12.5mm dia all as specified and directed .
Supply, installation, testing and commissioning in replacement of UNSV 63mm nominal bore and 15m long synthetic fibre, circular woven jacketed, rubberized fabric reinforced rubber lined (RRL) fire hose pipe of approved make bearing IS : 636-1988 type A mark and having TAC and MMD approval with a pair of 63 x 63 mm stainless steel instantaneous type, heavy duty delivery hose coupling (conforming to IS : 903) bound and riveted to the hose pipe with copper rivets and copper wire, complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of UNSV Stainless steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS: 903). complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement of UNSV of wall mounting swinging type First aid fire hose reel with drum, hanging bracket,Thermoplastic rubber (first aid hose) as per IS 12585 20 mm dia 30 mtr length to with stand 20 kg per Sq cm working pressure fitted with gunmetal nozzle and shut off valve of any size complete all as specified. The hose reel shall be conforming to IS 884-1985 including for 25 mm dia MS pipe connection from riser to hose reel sockets,nipples,elbows,valve etc. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete hook or MS stand as per site requirement and the rate for fixing/hanging items in the rates quoted(for internal hydrant and one each an either side of stage) including taking down the existing one complete and depositing to MES store yard all as specified and directed by .
Supply, installation, testing and commissioning in replacement of UNSV Cast Iron Butterfly Valve of size 80 mm dia ISI marked class (PN 1.6) including complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. Note :- (i) Body: Cast iron Epoxy / Powder coated as per IS: 210 Grade 220. (ii) Disc: S.G. Iron Epoxy/Power Coated as per B.S. : 2789 Grade 420/12. (iii) Seat: Nitrile rubber replaceable seat with moulded ‘O’ ring. (iv) Shaft: Carbon steel (Grade E N-8)
Supply, installation, testing and commissioning in replacement of UNSV Cast Iron Slim seal dual plate wafer type check valve of size 150 mm dia ISI marked class (PN 1.6) including cutting the existing pipe ,complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
All as per Srl item No. 66 here-in-before but size 80 MM.
Supply, fixing, jointing and testing in replacement of Bourdon type pressure gauge with gun metal isolation cock and copper ‘U’ Tube.having calibration of 0-14 Kg/cm2 ,and 100 mm dial size all as specified complete all as specified and as directed at site by the Engineer-in-Charge.
Supply, laying, jointing and testing in replacement of UNSV pressure switch (for operation at 0-15 kg/cm2) with required fittings and accessories complete, all as per directed by . Note :- Excavation will be measured separately.
Supply, installation, testing and commissioning in replacement of UNSV gun metal gate/Ball valves of size 20 mm bore with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778 of following sizes including taking out unserviceable gate valves and depositing to MES store yard complete all as specified and as directed.
All as per Srl item No. 70 here-in-before but size 25 mm bore.
Supply, installed, jointing and testing in replacement of unserviceable Foot Valve of size 150 mm (6”) dia. of cast iron non return valve both ends flanged conforming to IS 4038, complete all as specified and directed .
Supply, installation, testing and commissioning in replacement of UNSV cast Iron Sluice Valve of 150 mm bore ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete all as specified and as directed at site by the Engineer-in-Charge. Notes:- The cost of Earth work, joints & jointing materials of the sluice valve shall be deemed to be included in the quoted rates. .
All as per Srl item No. 73 here-in-before but size 100 MM.
All as per Srl item No. 73 here-in-before but size 80 MM.
Taking out or down defective sluice valve of size 150 mm bore from main line and opening carefully old defective sluice valve of any description and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the sluice valve after repair and refixing the same & testing after installation complete, all as specified and directed Engr-in-Charge. Note :- (i) The cost of Earth work, joints & jointing materials washers, gaskets ,necessary welding,nut,bolts ,washer and minor parts shall be deemed to be included in the quoted rates but Replacement of the defective parts i.e. stainless steel spindle of Sluice valve shall be measured and paid for separately as supply only under appropriate items of Schedule ‘A’
All as per Srl item No. 76 here-in-before but size 100 mm bore
All as per Srl item No. 76 here-in-before but size 80 mm bore
Supply only stainless steel spindle, heavy duty, threaded, with and including one gun metal check unit suitable for sluice valves of size 150 mm bore any description dismantled/fixed under appropriate items of Sch `A`
All as per Srl item No. 79 here-in-before but size 100 mm bore
All as per Srl item No. 79 here-in-before but size 80 mm bore
Taking out or down defective Fire hydrant valve from main line and opening carefully old defective Fire hydrant valve of any description and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the Fire hydrant valve after repair and refixing the same & testing after installation complete, all as specified and directed Engr-in-Charge Note:- (i) Spare part will be measured and paid for separately as supply only under appropriate items of Schedule ‘A’
Supply only Gun Metal hydrant coupling suitable for existing Fire Hydrant valve
Supply only Wheel suitable for existing Fire Hydrant valve
Supply only Gland nut of gun metal suitable for existing Fire Hydrant valve
Supply only Rubber packing for coupling suitable for existing Fire Hydrant valve
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in soft/loose soil including forming sides and bottom surface to required levels/slops/gradients etc. complete, all as specified and directed by Engr-in-charge Note:- The disturbed surface of roads/paths/plinths etc. shall be repaired and quoted rates deemed to include this aspect.
All as per item No. 87 above but hard/dense soil/PCC/Road etc, all as specified and directed..
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 meters above the starting point complete all as specified and as directed by Engr-in-Charge
M&L for sand cushioning to under ground cable provided with layer of sand 8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm complete all as specified and as directed.
Supply and lay unreinforced pre cast concrete cable covers class LV type-1, flat, size 250 x 150 x 40 mm factory made,complete all as specified and as directed.
Fixing / laying only old un-reinforced pre cast flat concrete/bricks cable protection cover of any description complete all as specified and directed . Note :- Old concrete cable protection cover retrived under item No.29 herein above shall be reused.
Supply, laying, jointing and testing in replacement of UNSV XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100V grade cross section area of size 16 Sqmm 4 core including making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed. Note:- Excavation, earth work ,sand & brick will be measured & paid separately.
All as per Srl item No. 94 here-in-before but 25 Sqmm 3½ core
Supply, laying, jointing and testing in replacement of UNSV PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor 1100V grade cross section area1.5 Sqmm 2 core on surface of wall/ceiling/roof /floor with proper cliping etc of the following size including making necessary connection, with busbar/MCCB/DB's & testing complete all as specified and directed.
All as per Srl item No. 96 here-in-before but 1.5 Sqmm 3 core
Repair of replacement of unserviceable Spare parts of Analog Addressable type Active/ Passive Repeater Fire Alarm panel with Backlit LCD Display, having Controls For Reset, Mute, Accept , Silence alarms and Self Test Conforming to BS5839 Standards and Duly Approved by EN54/LPCB complete all as specified and directed.
Supply, replacement, installation, testing and commissioning of Analog addressable MuliticriteriaType Detector Complete with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-99, complete with mounting base, LED, Programmable detector with inbuilt isolator or with isolator in base or with isolator modules, complete as required. (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant) complete all as specified and directed. Make: Honeywell/Siemens/Esser
Supply,replacement and Installation,Testing & Commissioning of Response Indicators for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete as required complete all as specified and directed. Make: Honeywell/Siemens/Esser
Supply,replacement,installation,Testing & Commissioning of Analog Addressable Type Control/Output Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Swicthes from 01-99, for initiating Hooter/Sounder/Strobes etc dully approved (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant). Make: Honeywell/Siemens/Esser
Supply,replacement, Installation,Testing & Commissioning of Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Swicthes from 01-99 dully approved(UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant). Make: Honeywell/Siemens/Esser
Supply,replacement, Installation,Testing & Commissioning of Addressable Type Manual Call Point with Mounting Base as required conforming (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant). Make: Honeywell/Siemens/Esser
Supply,replacement, Installation,Testing & Commissioning of Addressable Type Loop Powered Hooter Cum Strobe complete with Mounting Base as required conforming (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant). Make: Honeywell/Siemens/Esser
Supply, replacement,installation, testing and commissioning of PA panel supervised Ceiling Mounted Speakers with max SPL1M 96dB 70 to 94dB output. The speaker should be of 6W and shall have multiple tappings and complete with ceiling mounting arrangements on surface, line matching transformer and all accessories etc. as required and as per specification. (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested or EN54 compliant) complete all as specified and directed. Make: Honeywell/Siemens/Esser
Supply,replacement, installation, testing and commissioning of PA panel supervised Wall Mounted Speakers with max SPL1M 96dB 70 to 94dB output. The speaker should be of 6W and shall have multiple tappings and complete with ceiling mounting arrangements on surface, line matching transformer and all accessories etc. as required and as per specification. (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested or EN54 compliant) complete all as specified and directed. Make: Honeywell/Siemens/Esser
Supply, replacement and fixing of ISI marked (IS:9537-part 3 & 3419) 25 mm PVC conduit in concealed / exposed system in wall, ceiling or on floor including cutting of brick / rcc work, laying of conduit and fixing it with M.S. hooks , providing necessary sockets, bends, tees, junction boxes of required sizes etc as directed at site by the engineer-in-charge with supply of all material labour and T & P required for proper completion of work. conduit being laid either in concealed system in ceiling slab or wall or on surface or under the frame of false ceiling including flexible conduits or through wooden partition including clamping arrangements as required. (Conduit Make : AKG / Kalinga / Finolex)
Supply and fixing of 4 mm plain glass along with Rubber Beating etc change in FHC complete all as specified and directed.
Cutting of MS pipe mains 80 mm bore at different locations for insertion of valve, Provided of 2 Nos MS flange welded for valve cost of all included for Flange Packing Rubber Bolt Nut Washers. Notes:- The cost of Earth work, joints & jointing materials of the valve shall be deemed to be included in the quoted rates etc including dewatering work required for working FIRE pipe lines complete all as specified and directed.
Material and labour for painting with two coats off synthetic enamelled paint as per approved colour code of fire fighting Risers pipe line in fire nich ground floor to terrace pipe lines inside the shaft complete, all as specified and directed .
Supply, installed, jointing and testing in replacement of unserviceable non return valves of size 150 mm bore cast iron non return valve both ends flanged complete all as specified and directed. Notes:- (i) The cost of Earth work, joints & jointing materials of the non return valve shall be deemed to be included in the quoted rates.
All as per Srl item No. 111 here-in-before but 100 mm bore
All as per Srl item No. 111 here-in-before but 80 mm bore
Supply, laying, jointing and testing in replacement of UNSV MS water pipe of size 150 mm bore (ERW) 'C' class with 6mm thick,specified & confirming to latest revison of IS with necessary welding,nut,bolts & washer for following size off bore complete, all as pe Note :- Excavation will be measured separately.
All as per Srl item No. 114 here-in-before but 100mm
All as per Srl item No. 114 here-in-before but 80mm
All as per Srl item No. 114 here-in-before but 25mm
M & L for PCC 1:2:4 type B2 with 40mm grade stone aggregate as in foundation for outstanding around pole near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded stone aggregate as in foundation for hard standing around pole & near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 with 40 mm grade stone aggregate for coping of poles,stays incl. form work complete all as specified and as directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement plastering 1:4 complete all as specified and directed .
M&L for two coat of white wash over a coat of primer including prepaation of new surfaces complete, all as specified and directed .
Supply only NAF S 125 fire system, gaseous fire suppression systems complete, all as specified and directed .
Dismantling and opening of spare parts for servicing of water cooled DG set of following capacity coupled with alternator, Maintenance and servicing mechanically and electrically, including cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts,i.e diesel filter /oil filter /Air filter /fan belt /fuel pipe/ engine oil pipe /Engine Oil/distilled water etc as required at site and as per manufacturer's instructions and checking of valves & nozzles etc, reassembling the parts of DG set at position ensuring proper alignment connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Note here in below) Notes:-(i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge (iii) Fresh engine oil for DG sets shall be supplied by the contractor as “ Supply only” and shall be measured and paid separately under appropriate item of Sch ‘A’ . Its cost of filling is deemed to be included under the rates quoted by the contractor for above item.
50 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
125 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
365 KVA to 380 KVA, 3 phase, 50 HZ, Make:Kirloskar
500 KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
750 KVA 3 phase 50 HZ Make: CUMMINS/Kirloskar / Greaves /Caterpillar
Supply only element diesel filter with gasket suitable for following capacity of DG set dismantled / fixed under Sch `A` item No 125 here in above complete all as specified and directed.
50 KVA to 125 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
365 KVA to 380 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
500 KVA to 750KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
Supply only element Oil filter with gasket suitable for following capacity of DG set dismantled/fixed under Sch `A`item No 125 here in above complete all as specified and directed.
50 KVA to 125 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
365 KVA to 380 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
500 KVA to 750KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
Supply only Air cleaner element primary and safety for following capacity of DG set dismantled/fixed under Sch `A` item No 125 here in above complete all as specified and directed.
50 KVA to 125 KVA 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
365 KVA to 380 KVA, 3 phase, 50 HZ, Make: CUMMINS/Kirloskar
500 KVA to 750KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
Supply only corrosion resistor filter with gasket and CR plate for 365 to 500 KVA 3 phase 50 HZ Make: CUMMINS/Kirloskar of DG set dismantled/fixed under Sch `A` item No 125 here in above complete all as specified and directed.
Supply only element bypass filter with gasket for 500 KVA to 750 KVA capacity DG Set dismantled/fixed under Sch `A` item No 125 here in above complete all as specified and directed.
Supply,installation,testing and commissioning in replacement of unserviceable AVR unit suitable for 3 phase 50 HZ alternator suitable for 50 KVA to 750 KVA capacity of DG set complete all as specified and directed.
Dismantling and taking out the radiator fitted in following capacity of DG sets and strip opening complete radiator assembly,for servicing mechanically and proper cleaning of tubes with using de-scaling solution, including repair of water tubes and top/ bottom tanks by soldering / gas welding of leakage of tubes/tanks. including replacement of gasket, nut bolts,etc ensuring perfectly leak proof after servicing of radiator, re-assembling and fixing the same in position and testing the system complete all as specified and directed . Notes :- (i) Repairs/servicing/re-assembling and testing of radiator shall be carried out through a authorised representative of manufacturer. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, gaskets/ packing etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
50 KVA to 125 KVA ,3 phase 50 HZ, Make: CUMMINS/Kirloskar
365 KVA to 500KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
750 KVA 3 phase 50 HZ Make: CUMMINS/Kirloskar
Supply only the following items/spare parts suitable for raditor of existing make of DG set of the following variuos capacity dismantled/fixed under Sch `A` item No 132 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 132 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
Radiator hose set with clamp complete set for 50 KVA to 125 KVA, 3 phase 50 Hz DG set
Radiator hose set with clamp complete set for 365 KVA to 500 KVA 3 phase 50 Hz DG Set.
Radiator hose set with clamp complete set for 750 KVA 3 phase 50 Hz DG Set.
Water pump assembly complete set for 50 KVA to 125 KVA, 3 phase 50 Hz DG set
Water pump assembly complete set for 365 KVA to 500 DG set 3 phase 50 Hz, complete.
Water pump assembly complete set for 750 KVA DG set 3 phase 50 Hz, complete.
Supply only concentrated coolent suitable for radiator of DG set any capacity drained out / filling under Sch `A`item No 125 here in above complete all as specified and directed.
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) suitable for Engine of DG set any capacity drained out / filling under Sch `A` item No 125 here in above complete all as specified and directed.
Supply only distilled water Complete, all as specified and directed by Engr-in-Charge,
Dismantling and taking out the PT fuel system including injectors assembly fitted in following capacity of DG sets 3 phase 50 HZ of DG set and strip opening of PT fuel system including injectors assembly for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and calibration of Fuel Injection after repair/ servicing /overhauling and re-assembling and fixing the same in position and testing complete all as specified and directed . Notes :- (i) Repairs/servicing / reassembling and testing of Fuel injector pump shall be carried out through a authorised service center on testing machine.(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
50 KVA to 125 KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
365 KVA to 500KVA, 3 phase 50 HZ, Make: CUMMINS/Kirloskar
750 KVA 3 phase 50 HZ , Make: CUMMINS/Kirloskar
Supply only the following items/spare parts suitable for PT fuel system including injectors assembly of existing make of DG set of capacity 50 to 750 KVA, 3 phase,50HZ for capacity dismantled/fixed under Sch `A` item No 137 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 137 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
Kit injector barrel plunger
Kit Gasket Governor set
Ball Bearing
Gasket fuel pump .
Screen filter .
Ball check .
Gasket Injector .
Seal ‘O’ ring .
Pump gear fuel .
Shaft fuel pump drive .
Shaft tachometer drive .
Bushing tachometer drive.
Plunger governor .
Plug injector orifice.
Seal dust.
O Ring injecter.
Kit seal .
Supply , fixing, connecting and testing in replacement of following unserviceable spare parts of suitable for Existing Make of DG set of 50 to 750 KVA capacity,3phase,50HZ complete all as specified and directed ..
Seal key way.
Water separator .
Oil temperature gauge.
Water temperature gauge.
Oil pressure gauge 0 to 7 kg/cm2 .
Hours meter.
Hump hose & bend
Toggle switch
Elbow male union.
Dust cap.
Ignition switch along with duplicate keys.
Switch Temp .
Switch pressure .
Diaphram for 50 KVA DG set
Shut Down Valve
Hose fuel suction suitable for 50 KVA DG set.
Hose fuel suction suitable for 365 to 750 KVA DG set.
Hose fuel Return suitable for 50 KVA DG set.
Hose fuel Return suitable for 365 KVA to 750 KVA DG set.
Hose Fuel, Water sperator to filter suitable for 365 to 750 KVA DG set.
Hose Fuel, Filter to Fuel pump suitable for 365 KVA to 750 KVA DG set.
Dismantling and taking out the self starter,12 Volt DC fitted in 50 KVA to 125KVA, 3 phase 50 HZ of DG sets and strip opening of Self starter 12 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling of Self starter 12 Volt DC after repair/ servicing /overhauling and fixing the same in position and testing complete all as specified and directed. Notes :- (i) Repairs/servicing / reassembling and testing of Self starter 12 Volt DC shall be carried out through a authorised service center .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Supply only the following items/spare parts suitable for self starter, 12 Volt DC fitted in 50 KVA to 125 KVA 3 phase 50 HZ of DG set , dismantled/fixed under Sch `A` item No 140 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 140 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
Solenoid switch suitable for self starter, 12 Volt DC
Commutator suitable for self starter, 12 Volt DC
Carbon brush suitable for self starter, 12 Volt DC
Field coils suitable for self starter, 12 Volt DC
Bendix pinion assembly suitable for self starter, 12 Volt DC
Bushe suitable for self starter, 12 Volt DC
Dismantling and taking out the self starter, 24 Volt DC fitted in 365 to 750 KVA 3 phase 50 HZ of DG sets and strip opening of Self starter 24 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling of Self starter 24 Volt DC after repair/ servicing /overhauling and fixing the same in position and testing complete all as specified and directed. Notes :- (i) Repairs/servicing / reassembling and testing of Self starter 24 Volt DC shall be carried out through a authorised service center .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Supply only the following items/spare parts suitable for self starter, 24 Volt DC fitted in 365 KVA to 750 KVA 3 phase 50 HZ of DG set, dismantled/fixed under Sch `A` item No 142 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 142 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
Solenoid switch suitable for self starter,24 Volt DC
Commutator suitable for self starter, 24 Volt DC
Carbon brush suitable for self starter, 24 Volt DC
Field coils suitable for self starter, 24 Volt DC
Bendix pinion assembly suitable for self starter, 24 Volt DC
Bushe suitable for self starter, 24 Volt DC
Disconnecting existing non functional armature of self starter, 24 Volt DC fitted in 365 to 750 KVA DG set , dismantling and strip opening of the armature of self starter, 24 Volt DC, removing the old existing burnt windings, cleaning the slots & rewinding of the armature of self starter, 24 Volt DC, including supply with existing gauge super enameled copper conductor , including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc as required at workshop and transportation to site & refixing on same position & testing complete all as specified and directed .
Dismantling of Old unserviceable batteries 12 Volt, 180 AH, from DG set and supply & fixing maintenance free batteries of 12 Volt, 180 AH capacity with electrolyte fully charged battery including interconnection, commissioning and testing complete all as specified & directed.
Supply, fixing, connecting and testing in replacemnt of UNSV turbo charger service kit suitable for following capacity of DG sets as per existing shape and size complete all as specified and directed.
50 KVA 3 phase 50 HZ
125 KVA, 3 phase 50 HZ
365 KVA to 750 KVA, 3 phase 50 HZ
Supply and replace of defective existing battery lead (Heavy duty) PVC insulated copper conductor single core multi stranded minimum 25 Sqmm one side fixed with clamp and other side fixed with brass battery terminal of heavy duty for 3 Mtr length (Set of two)
Disconnecting and taking out old unserviceable belts of the DG set and supply and fixing new belt suitable for following capacity of DG set engine match the existing complete all as specified and directed.
Belt for Fan,self complete set suitable for DG Set 50 KVA
Belt for fan fuel pump,water pump & oil pump of complete set suitable for DG Set 125 KVA
Belt for fan fuel pump,water pump & oil pump of complete set suitable for DG Set 365 to 380 KVA
Belt for fan fuel pump,water pump & oil pump of complete set suitable for DG Set 500 to 750 KVA
Disconnecting and taking out engine fitted in 50 KVA to 750KVA 3 phase 50 Hz of DG set ( Make: Cummins/Kirloskar) , dismantling and strip opening of complete engine of water cooled DG set of suitable capacity 3 phase 50 Hz for carrying out repair and complete over hauling , mechanically and electrically, cleaning,oiling/greasing , and fixing of serviceable parts in position, and removing & replacement of unserviceable/ defective parts /spares with new parts,as per manufacturer's instructions cleaning , oiling /greasing,descaling of water jackets,decarbonizing cylinder heads including refacing and lapping of valves, valve-seats, grinding of crank shaft or any other machining work required at site, allingment of connecting rods including matching with crank shaft. and reassembling the engine of DG set at position ensuring proper alignment and coupling the engine with alternator, complete all as specified and directed. (including mentioned Note in here in below)
Notes for Sch A item No. 150 here in above : (i) Repairs/Overhauling / reassembling and testing of engine of DG set shall be carried out through a authorised service center . (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ here in after under item No.29 but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, `O’ rings, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of loading, unloading & transportation to and fro authorized service centre and machining job etc.as required (iv) The element for connecting to existing system and making DG set perfectly operational and testing at site connected load to the entire satisfaction of the Engineer-in-Charge shall be included/covered under the rates quoted in Sch A item No.1 here in above consider for Maintenance and servicing.
Supply only the following items/spare parts suitable for DG set capacity 100 to 285KVA 3 phase 50 Hz of dismantled/fixed under Sch `A` item No 150 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 150 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
Liner cylinder
Piston
Pin Piston
Ring Snap
Gasket cylider head (Front)
Gasket cylider head (Rear)
Gasket cylider head Cover
Valve Intake (ALTV)
Valve Exhaust (ALTV)
Guide Valve
Seal valve steam
Cotter valve
Bearing con rod
Bearing Main
Overhaulling Gasket Packing kit full
Material & labour for replacement of unserveceable interconnection wiring and its interlocking system in AMF electric control panel for DG set with using and including PVC insulated and unsheathed stranded copper conductor cable, single core, minimum 1.5 Sqmm size or as required 1100 Volts grade cable for making functional controls of the DG set, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of DG set in auto and manual mode, checking AC/DC circuits and removing & replacement of defective / unserviceable parts with new parts, complete all as specified and directed . Notes:- (i) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable wiring. for its smooth functioning and proper interlocking including shutt down on high water tempreture and low Oil pressure. (ii) All control wires shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. the cost of same are deemed to include under these items. (iii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc.
Supply only the following items/spare parts suitable for AMF pannel of DG set , dismantled/fixed under Sch `A` item No 152 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 152 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
Electronic timer,on delay type, dual range, suitable of 220 Volts/ 24 Volts, 2NO+2NC, 50 Hz, AC supply/ DC supply , for 0-60 seconds .
Electronic coil voltage 220 volts suitable for power contactor 3 pole rang 325 Amps to 400 Amps complete all as specified and directed .
Electronic coil voltage 220 volts suitable for power contactor 3 pole rang 600 Amps to 850 Amps complete all as specified and directed .
Auxilliary Contactor No volt coil suitable for 325 to 850 Amp Contactor
Electronic battery charger 12/24 Volts suitable for AMF panel of DG set
Auxilliary relay 8 pin, 24 Volts ,DC , 2 change over.
Auxilliary relay 8 pin, 220 Volts , AC , 2 change over.
Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply.
Indicating lamps LED type with holder for 12 / 24 volts DC supply
Labour only for daily basis complain for minor repair of engine ,AMF panel,alternator and its testing on installation complete, by employing one DG set mechanic on receving the complaint slip from MES Service Centre and returning the same after dully completing the job to MES Authority complete,all as specified and directed by Engr-in Charge
Supply and replacement of Rotary pump with suction pipe not less than 1 Mtr complete all as specified and directed by Engineer-in-Charge
Disconnecting, dismantling,and taking out of unserviceable current Transformer from HT complete & Supplying installing commissioning and testing of new current transformer,indoor epoxy type, ratio 180/0.578 conforming to IS 2705 part I of 1981, 50 Hz for HT 11 KV having insulation level class1-P10, IL-28/75kv , burden of 15VA and breaking capacity 18.4 KA for 1.0 second and necessary thimbles nut bolts etc suitable for existing 11 KV HT VCB complete all as specified and directed Make:- Crompton Greaves or equivalent make approved by GE.
shivrefrigeration
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .