| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹25.3 L+₹1.0 L (4.16%)Rejected-Finance | L2 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 3 | L3₹25.3 L+₹1.1 L (4.44%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 4 | L4₹25.4 L+₹1.2 L (4.92%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 5 | L5₹25.7 L+₹1.5 L (6.15%)Rejected-Finance | L5 | Rejected-Finance Rejected for acceptance being not lowest. |
Tender Value
Refer Docs
EMD Value
₹47,000
Closing Date
1 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY ALONG WITH CERTAIN OTHER CONNECTED WORKS AT AF-II UNDER GE (AF) JAMNAGAR NO.2
2021_MES_420554_1
8279/E8
Open Tender
Miscellaneous Works
Item Rate
Jamnagar
Please refer tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Jamnagar No.2
₹47,000
Yes
6 Apr 2021
9 Feb 2021
2 Mar 2021
9 Feb 2021
1 Mar 2021
23 Feb 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide but not exceeding 1.5 m in depth for foundation etc or for shafts and getting out in soft/losse soil including trimming sides and bottom of trenches complete all as specified.
All as per item no.1 above but depth exceeding 1.5m and not exceeding 3.0m
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soil complete all as specified.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L for sand cushioning to underground cable by filling of sand in and around LT cables 8cm thick below and 15cm above the cableafter laying the cable and gently punning down all as specified and as directed. Note: Punned thickness shall be measured for payment.
Taking down old un reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.
Laying only PCC cable cover for LT / HT UG cable, of any description retrieved from Srl item No 6.0, complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Taking out old/unsv/damaged PCC /steel pole, 9.0/11.0m long complete with all accessories incl demolition of concrete with necessary excavation and earth work and site clearance complete all as specified and directed.
Supply and erect in true vertical position Prestressed concrete pole, 9.0 metres long. of size 102mm x 152mm at top and 102 mm x 289mm at bottom class 10 complete all as specified and directed. Note: (i) PCC foundation & coping shall be measured & paid separately.(ii) Excavation earth work and PCC will be measured and paid for seperately under respective item of schedule "A".
Supply and fix CI cable route indicator 150mm dia, 5mm thick duly engraved with "HT 11000 volts" having CI rod 10mm dia, 50 to 70 cm long, duly welded to round plate complete with PCC 1:4:8 including taking out old unsvall as specified and as directed.
Supply and fix CI cable route indicator 100mm dia, 5mm thick duly engraved with "LT 1100 volts" having CI rod 10mm dia, 50 to 70 cm long, duly welded to round plate complete with PCC 1:4:8 all as specified and as directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of poles complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in benching, coping, including weathering slightly rounded or chamfered angles as directed including necessary formwork complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of stay assembly complete all as specified.
S & F GI pipe light grade100 mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos (Flat iron 50x6mm) with, nuts and bolts complete all as specified and as directed.
All as per item no.16 above but of size 80mm bore
All as per item no.16 above but of size 50mm bore
M & L taking down old/unsv and Stay assembly set complete using 230x230x6mm thick, stay plate and 16 mm dia rod,180 cm long with all accessories as shown in electrical plate no.1 (Loop type insulator, stay clamps, excavation and concrete measured seperately) complete all as specified and directed.
M & L for loop type insulator,vitreous porcelain whits brown or green with overall dimension of 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
M & L for galvanised stay strand of size 7/4mm complete suitable for stay assembly incl connection on pole complete all as specified and directed.
Material and labour for synthetic insulating mat of size 2Mx1Mx25mm complete as per ISI marked and it is should be approved by CPRI and as per IS-8437 complete all as specified and directed.
Taking out old/unsv LT /HT cable any size from trenches/duct, checking by megger and carry out repair/replacement of defective cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty" PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 185Sqmm nominal cross sectional area 3.5 core confirming to IS specification complete all as specified and directed.
All as per ser item no.24 above but of size 150sqmm 3.5core
All as per ser item no.24 above but of size 120sqmm 3.5core
All as per ser item no.24 above but of size 95sqmm 3.5core
All as per ser item no.24 above but of size 70sqmm 3.5core
All as per ser item no.24 above but of size 50sqmm 3.5core
All as per ser item no.24 above but of size 35sqmm 3.5core
All as per ser item no.24 above but of size 25sqmm 3.5core
All as per ser item no.24 above but of size 16sqmm 4core
Supply, laying, jointing, testing and commissioning XLPE insulated, sceened PVC bedded, galvanised stell strip or wire armoured, electric power cable (heavy duty) with multistranded aluminium conductors,11KV grde of size 95 Sqmm x 3 core, IS-7098 marked , suitable for HT 11KV(E) system, laid in trenches/ducts/encased in GI pipe/fixed to pole complete including taking out old us UG cable all as specified and directed.
Note for Item no.24 to 33 : Excavation & earthwork, duct work, GI pipe for laying of cable and sand cushioning / cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under respective items of Schedule `A'.
Supply and fix cable jointing kit for 11 kv grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium. Conductor cable of size 50 to 95 sqmm complete all as specified and directed.
Supply and fixing in replacement of pre-fabricated MS structural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting, all as directed and specified.
Supplying, installing, testing and commissioning in replacement of air-break, gang operated, triple pole switch, outdoor, vertical mounting type of capacity 200 Amps, ISI marked, mechanically operated, mounted on insulators (12 Insulators) and frame work complte with operating mechanism worked from ground level, with locking arrangements including Godrej (Feedom) 65mm pad locks with two keys, complete with fuse mounts, fuse carriers and HT fuse elements having 16 amp rating suitable for HT 11KV, 50 Hz AC supply incl necessary electric connections, complete including taking down old US gang operated device from poles all as specified.
S & F in replacement of lightening arrestor expulsion type completed with all fittings transmission class discharge capacity 65 Kilo Amps suitable for 11000 volts grade complete all specified and as directed
Taking proper shut down in writing/disconnecting up the LT and HT electric mains from transformer of any capacity , removing the lid/cover for inspection at site and to facilitate minor repairs after draining out the transformer oil, reassembling the transformer, refilling of transformer oil (new or old) installing ,commissioning and testing at site complete all as directed. (All the parts required to be replaced shall be measured and paid seperately)
S & F HT bush suitable for any model/capacity of transormer Indoor/outdoor of suitable rating KVA complete all as specified and directed.
S & F LT bush suitable for any model/capacity of transormer Indoor/outdoor of suitable rating KVA complete all as specified and directed.
S & F HT bush rod of brass 3/8" diasuitable size both ends threaded including nuts, checknuts and washers suitable for transformer as per site complete all as specified and directed.
S & F LT bush rod of brass 20/25mm dia and 205/225mm long with 5 nuts washers rubber washers etc suitable for transformer rating as per site complete all as specified and directed.
S & F Gasket set of synthetic rubberised cork sheet 5mm thickness with suitable holes for any model transformer rating 50 to 315 KVA complete all as specified and directed.
S & F Nuts bolts and wahers fully threaded of MS size 5/8"x2" or as per requirement complete all as specified and directed.
M & L for Spray painting of transformer at site with one coat of weather proof grey synthetic enamel paint after removing all dust rust carbon and oily spots, including well preparation of surfaces and writing /marking SM/MES No as 25mm stencil with white paint complete all as specified including cleaning of temperature gauge and silica gel , oil temperature level and directed for transformer rating as per site requirement complete all as specified and directed.
S&F cast iron wheel of transformer of suitable size including nuts bolts, split pins welding works as required at site complete all as specified and directed.
S&F breather assembly complete with silica gel suitable for any model of transformer rating as per site requirement to air column of conservator tank complete all as specified and directed.
S&F temperature guage dial type suitable for transformer outdoor/Indoor type of any capacity with provision of GI nipple suitable size if required including testing on completion complete all as specified and directed.
Supply and fill transformer oil of good quality having not less than 45 KV dielectric strength at site or factory premises for toping up or replacing the old oil complete all as specified and directed. Make- Savita/Power oil as per IS 335 of 1983.
Supply and fix danger notice plate made of 1.6 mm thick mild steel sheet , vitreous enameled white, of size 20 x 15cm with figures, letter, and conventional skull bones in signal red colour and fixed with mild steel clamps made of 25 x 3 mm including MS flat iron, nuts, bolts and washers etc for LT poles / Penals / Sub station etc with voltage and danger indiated in Hindi and English complete all as specified and directed.
Earthing complete with galvanised steel earth electrode plate of size 600 x 600 x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
All as per item no.51 above but using galvanised earth lead wire 4.0mm as earthing lead
M&L for Pre-cast cement concrete solid block masonry with blocks of mix (1:5:8) exc 10cm in width and setting in mortar, complete in CM (1:4) complete all as specified and directed.
M & L for taking proper shut down of electric supply and shifting of compact sub stn at a distance not more than 50m or location as per direction of Engr-in-Charge. (Compact Sub stn is comprising of HT VCB, Transformer and LT panel complete in one sheet metal enclosure) after disconnecting incoming HT cable and outgoing LT cables, disconnection of earthing and cable connection to transformer including demolition of foundation and refixing / installation at site as per direction and reconnecting HT and LT cables, transformer connection and earthing complete all as specified and directed.
M & L for taking proper shut down of electric supply and shifting of Ring Main unit/ VCB outdoor panel along with metering module at a distance not more than 50m or location as per direction of Engr-in-Charge after disconnecting incoming and outgoing HT cable and earthing including demolition of foundation complete and refixing / installation at site as per direction and reconnecting HT cables and earthing complete all as specified and directed.
M & L for taking proper shut down of electric supply and shifting of DG set complete with canopy, fuel tank and AMF panel at a distance not more than 50m or location as per direction of Engr-in-Charge after disconnecting incoming and outgoing LT cable and earthing including demolition of foundation complete and refixing/ installation at site as per direction and reconnecting LT cables and earthing complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces using cement plaster 1:4 complete all as specified and directed.
S & F electrical insulated rubber mat of size 1m x 2m x 19mm long confirming to IS:15652:2006 complete all as specified and as directed.
M&L for Boring of holes 150 mm dia under taxi track / road pavement hard standing by trenchless technology using latest technique and necessary machine and inserting HDPE pipe of 150 mm dia upto full length of bore complete all as specificated and directed.
Prime Decor
Hirachand Sunderji and co
jagdish machinery stores
Dara Paras.D
M/S Badri Electicals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .