Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹85,200Qualified Make: zebronic
Model: ZEBRONIC ZEB-U1200 2 SHAH MARKET KATPIECE GALI BOMBAY BAZAR KHANDWA MADHYA PRADESH 450001 UDYAM MP 27 0003915 | EAST NIMAR | MADHYA PRADESH | 450001 | Make: zebronic
Model: ZEBRONIC ZEB-U1200 | ₹85,200 | L1 | Qualified |
| 2 | L2₹92,400Qualified Make: ELNOVA
Model: ELNOVA I1002 SC 1 1ST FLOOR GOVERDHAN PATH GANESH MARG BAPU NAGAR JAIPUR RAJASTHAN 302015 | JAIPUR | RAJASTHAN | 302015 | Make: ELNOVA
Model: ELNOVA I1002 | ₹92,400 | L2 | Qualified |
| 3 | L3₹95,904Qualified Make: LUMINOUS
Model: 1000VA LUMINOUS UPS UNO 1KVA | Make: LUMINOUS
Model: 1000VA LUMINOUS UPS UNO 1KVA | ₹95,904 | L3 | Qualified |
| 4 | L4₹97,786.08Qualified Make: MIRCOTEK
Model: Microtek 1 KVA UPS - 1000VA TG 102 SHUKLA APARTMENT OPPSITE STATE BANK OF INDIA KAMPTHI LINE RAJNANDGAON RAJNANDGAON CHHATTISGARH 491441 | RAJNANDGAON | CHHATTISGARH | 491441 | Make: MIRCOTEK
Model: Microtek 1 KVA UPS - 1000VA TG | ₹97,786.08 | L4 | Qualified |
| 5 | L5₹98,064Qualified Make: microtek
Model: Microtek Line Intractive 1.0/800 with 1 year warranty SHOP NO 32 A MAHESH NAGAR NEAR MAHESH NAGAR SUB POST OFFICE MAHESH NAGAR BABYAL ROAD AMBALA AMBALA HARYANA AMBALA HARYANA 133001 UDYAM HR 01 0004052 06AVBPG6891R1ZV B G R | AMBALA | HARYANA | 133001 | Make: microtek
Model: Microtek Line Intractive 1.0/800 with 1 year warranty | ₹98,064 | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
26 Jun 2018, 1:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 24 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 1.0/800 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through Yes Yes
No 1/4 inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as Yes - 2/4 per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date ETDC& 28MH&M/S 14/12/2016 - Name Of Lab ETDC& 28MH&M/S 14
NCR
DELIHI - Address of Lab EETDC& 28MH&M/S 14
DELIHI
INDIA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mahaveer Saini N 110003
Tariff Commission
7th floor
Lok Nayak bhawan
New Delhi 24 15 EMD Required No ePBG Required No
226790
GEM/2018/B/32270
Line Intractive UPS with AVR
15 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 24 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 1.0/800 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through Yes Yes | - | - | - |
| No 1/4 inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as Yes - 2/4 per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date ETDC& 28MH&M/S 14/12/2016 - Name Of Lab ETDC& 28MH&M/S 14 | - | - | - |
| NCR | - | - | - |
| DELIHI - Address of Lab EETDC& 28MH&M/S 14 | - | - | - |
| DELIHI | - | - | - |
| INDIA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mahaveer Saini N 110003 | - | - | - |
| Tariff Commission | - | - | - |
| 7th floor | - | - | - |
| Lok Nayak bhawan | - | - | - |
| New Delhi 24 15 EMD Required No ePBG Required No | - | - | - |
Exempted
26 Jun 2018
19 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_226790.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER