Tender Value
₹1.4 L
EMD Value
₹3,600
Closing Date
30 Sept 2026, 5:00 pmClosed
HOD MMD
KEL KUNDARA KOLLAM 691501
SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 08MTR WITH WINCH OPERATION MINIMAST WITH 04NOS OF 150W LED FLOOD LIGHTS AT CHENNAMATOM JUNCTION NEAR PUBLIC LIBRARY IN KOOROPPADA GRAMA PANCHAYAT WARD 12 13 14
2026_KEL_870198_1
KEL/FL/MMD/K89/EPROC/26-27
Open Tender
Electrical Works
Item Rate
CHENNAMATOM
PLEASE REFER NIT
3 documents required · 3 mandatory
₹500
₹3,600
Yes
6 Oct 2026
15 Sept 2026
1 Oct 2026
15 Sept 2026
30 Sept 2026
15 Sept 2026
15 Sept 2026 - 19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Civil Works | |||||
| 1.001 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 1.3 | cum | - | - |
| 1.002 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 0.03 | cum | - | - |
| 1.003 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 32.2 | kilogram | - | - |
| 1.004 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 4 | sqm | - | - |
| 1.005 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.38 | cum | - | - |
| 1.006 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 1.7 | cum | - | - |
| 2Electrical Works | |||||
| 2.001 | OD93723/2026-2027:
Supply installation testing and commissioning of Octagonal Pole made of hot dip
galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base
plate dimensions of 250x250x12mm suitable for head frame including round arm
luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement
including single drum winch( manual operated gear box) for lowering and lifting of
lights for maintenance purpose and including connector foundation bolt 4 nos existing
RCC foundation and junction box, SS 5mm wire rope, tumbils and D clamp etc,
complete 8 Meters | 1 | each | - | - |
| 2.002 | 90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 4 | each | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
BOQ_1474390.xls
BOQ • 0.28 MB
date.pdf
PDF • 0.03 MB
date.pdf
PDF • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .