Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹95.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.3 Cr+₹9.0 L (7.54%)Rejected-Finance VILLAGE DHAR P O DASHERA TEH BALH REWALSAR DISTT MANDI HP 175036 | REWALSAR | MANDI | HIMACHAL PRADESH | 175036 | 2 | Rejected-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical M S ASHAPURI INFRACON PVT LTD VILLAGE AND PO HURLA TEHSIL BHUNTER DISTT KULLU H P | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹57.8 L
EMD Value
₹90,290
Closing Date
5 Jan 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
JSV Division No.1 Kullu
Anchor block for distribution system, Cement concrete main channel at various RDs, sub outlets 10 Nos, outlets 28 Nos, laying, jointing and testing of GMS tube of various dia for distribution system, and providing, laying, jointing and testing of MSE
2021_HPIPH_55146_1
18301-350
Open Tender
Civil Works
Item Rate
Kullu
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
EE
₹90,290
Yes
11 May 2022
29 Dec 2021
6 Jan 2022
30 Dec 2021
5 Jan 2022
30 Dec 2021
180 days
Amount
Excavation in foundation and trenches up to all depths and in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/ hard rock, chiseling /wedging of soft / hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking, timbering and dewatering wherever required. Stacking usable and unusable material /soil separately and after laying jointing and testing of pipes, returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed with in all leads/ lifts including restoration of un-metalled surfaces to its original conditions and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. Complete in all respects within all leads and lifts as per direction of the Engineer-in-Charge.
Excavation in drains and channels etc. in earth work including dressing of side and bed and disposing of excavated earth upto a lead of 20 metres and lift upto 1.50 metres disposed earth to be levelled and neatly dressed:pick jumper work as per the direction of Engineer-in-Charge.
Cement concrete lining 15cm thick or less for irrigation channel using cement concrete 1:3:6 ( 1 cement, 3 sand , 6 graded stone agg. 20 mm nominal size and curring complete with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge..
Hand Mixed Conrete lining In bed
Hand Mixed Conrete lining on side slopes
Extra allowances for form work in Cement concrete lining on side slopes.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size )and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge.
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in: -
Foundation and plinth
Wall ( any thickness but not less than 0.10 mtrs. Thickness) including attached pillasters buttresses, plinth and string courses etc. from top of foundation level upto floor two level.
Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level including cost of binding wire with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and fifts in:-
Vertical surfaces such as wall(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like -
Providing and fixing arrangement for distribution of irrigation water at the outlets in all lead and lifts as per the direction of Engineer-in-charge
Providing and laying in cement concrete 1:2:4 (1cement 2sand 4 graded crushed stone agg.20mm nominal size and curing complete excluding cost of form work and reinforcement for reinforced work in foundation and plinth within all leads and lifts
Providing and laying in cement concrete 1:2:4 (1cement 2sand 4 graded crushed stone agg.20mm nominal size and curing complete excluding cost of form work and reinforcement for reinforced work in column within all leads and lifts
Providing , laying, fixing, jointing and testing in trenches MSERW pipe (ISO:3183:2012) of following dia meters confirming to X- 46 and X-56 (latest with upto date amendments) steel grade- A having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
FIS Bashing:- MSERW Pipe L-210 Grade-A 300 mm dia. 4.4 mm thickness Flange T-5 (FIS Bashing) RD 0 to RD 140
Laying, jointing and testing in trenches to levelled to grades, GI flanged pipes of following diameter confirming to IS:1239-1990( Part-II) (latest with upto date amendments) having class of pipes as per IS code as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
Distribution Network :- GMS Tube 65 mm dia. Mediam Class 3.6 mm thick Flange T-5 Distribution Network
GMS Tube 80 mm dia. Mediam Class 4 mm thick Flange T-5 Distribution Network
GMS Tube 100 mm dia. Mediam Class 4.5 mm thick Flange T-5 Distribution Network
GMS Tube 125 mm dia. Mediam Class 4.85 mm thick Flange T-5 Distribution Network
GMS Tube 150 mm dia. Mediam Class 4.85 mm thick Flange T-5 Distribution Network
Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2011 (latest with upto date amendments) havingwall thickness as per code with bevelled /plain ends in a random length of 4 to 7 meters, including manufacturingreducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying inexcavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respectsto the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
Distribution Network:- GMS Tube 65 mm dia. Mediam Class 3.6 mm thick Distribution Network
GMS Tube 80 mm dia. Mediam Class 4 mm thick Distribution Network
GMS Tube 100 mm dia. Mediam Class 4.5 mm thick Distribution Network
GMS Tube 125 mm dia. Mediam Class 4.85 mm thick Distribution Network
GMS Tube 150 mm dia. Mediam Class 4.85 mm thick Distribution Network
Chuni lal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .