| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹5.2 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L2 |
| 3 | Rejected-Technical 31 A K ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L3 |
| Sl No | Description | Qty | Unit | R.P.ELECTRONICS L2 | STANDARD ELECTRONICS L3 | Eastern Commerce L1 |
|---|---|---|---|---|---|---|
| 1.00Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity | ||||||
| 1.01 | 1.5 TR split type high wall AC machine (Minimum rated cooling capacity should be 4500 Kcal/hr or 18000 BThu/hr or 5250 watt). | 12 | Nos | 38,825 ₹4.7 L | 40,000 ₹4.8 L | 37,800 ₹4.5 L |
| 2.00 | Standard installation, testing and commissioning of 1.5 TR split including hole cutting, finishing etc as per direction of the Engineer-in-charge. | 12 | Nos | 3,000 ₹36,000 | 2,000 ₹24,000 | 2,000 ₹24,000 |
| 3.00 | Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.5TRsplit AC as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units. | 36 | Mtr | 600 ₹21,600 | 1,200 ₹43,200 | 550 ₹19,800 |
| 4.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 12 | Nos | 2,000 ₹24,000 | 1,400 ₹16,800 | 990 ₹11,880 |
| 5.00 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 120 | Mtr | 100 ₹12,000 | 200 ₹24,000 | 75 ₹9,000 |
Tender Value
₹6.6 L
EMD Value
₹13,104
Closing Date
17 Feb 2025, 3:00 pmClosed
PExecutive Engineer, Mechanical Division,PWD, Ag
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation, Testing and Commissioning of Split Type air conditioning system in the Hall Room of Tripura High Court Bar Association at Ground floor of the High Court of Tripura Building, Agartala
2025_CEPWD_58074_1
84/EE/DNIeT/MECH.DIVN/AGT/2024
Open Tender
Electrical Works
10 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹13,104
27 May 2026
7 Feb 2025
17 Feb 2025
7 Feb 2025
17 Feb 2025
7 Feb 2025
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
1.5 TR split type high wall AC machine (Minimum rated cooling capacity should be 4500 Kcal/hr or 18000 BThu/hr or 5250 watt).
Standard installation, testing and commissioning of 1.5 TR split including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.5TRsplit AC as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
R.P.ELECTRONICS (BID ID -167179)
STANDARD ELECTRONICS (BID ID -167184)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_59062.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid