Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.1 L+₹20,453.60 (3.45%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹6.3 L+₹33,628 (5.67%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹6.6 L+₹67,451 (11.4%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹6.7 L+₹74,011 (12.5%)Rejected-Finance | L5 | Rejected-Finance NOT L1 |
Tender Value
₹8.2 L
EMD Value
₹16,380
Closing Date
24 Jan 2020, 9:00 amClosed
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIR REPLACEMENT OF SECURITY LIGHTS AND CONNECTED SWITCH GEAR INCLUDING STREET LIGHT POLES AND ALLIED WORKS AT ZONE B AND C MIL STN JAMNAGAR.
2019_MES_309231_1
8691
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Jamnagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
₹16,380
Yes
3 Feb 2020
26 Dec 2019
24 Jan 2020
4 Jan 2020
24 Jan 2020
4 Jan 2020
Amount
Excavation in trenches not exceeding 1.5 m wide in depth and getting out soft/loose soil for laying of cables etc. complete all as directed by engineer in charge
Returning filling including spreading levelling watering and well ramming in layer not exceeding 25 mm thick complete all as specified and as directed by Engineer in charge
Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as directed by Engineer in charge
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming complete all as specified and directed by engineer in charge
Supply & Laying precast PVC cable concrete cable cover LV voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by engineer in charge
Supplying & Laying in trenches / poles / walls XLPE insulated, armoured, heavy duty electric power cable with aluminium conductor 1100 volts grade for following size including taking out old unserviceable cable complete all as specified and directed by Engineer-in-Charge. NOTE : Excavation and earth work, GI pipe protection, sand cushioning shall be measured and paid under relevant items.
25 Sqmm x 3.5 core,
16 Sqmm x 4 core
10 Sqmm x 4 core
6 Sqmm x 2 core
M & L in repair for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe (light grade) and watering pipe 20mm bore GI pipe(light grade) and chamber PCC (1:4:8) type D2( using 40mm graded stone aggregate), coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/DB up to a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing wire of same size up to 7.5m shall deemed to be included into quoted rate
S& F Street light bracket made out of GI pipe 25 mm light grade ISI marked 1.5 Mtr long bend to shape as required at site including M S Clamp made out of flat iron 50 X 5mm with necessary nuts Bolts etc. all as specified as suitable of LED fitting complete all as specified and directed by engineer in charge
S&F GI Pipe light grade 40 mm for road crossing/ on pole/ on wall for protection of LT Cable laid in trenches, fixed to wall/pole including MS clamps etc. as directed by Engr-in-Charge
Supply and fixing automatic street light switch using Nature switch/astronomical switch for automatic switching of streel light based on Lux level of natural light. The sensor (Nature switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/wall mounted enclosure made of rust proof. Electric shock proof, termite proof and FR grade special moulding compound (sintex make smc junction box) conforming to IP-54 degree of ingress. The contractor, MCB and circuit wiring should be suitable enough to take load of 5-8 KW conforming for cat part No Swadeep-02EC5KW1P. including necessary connection to be provided from running phase/panel to the automatic panel complete all as specified and directed by the Engr-in-charge. Make (i) Nature Switch : Kaktiya Energy system PVT lt Hyderabad/Bajaj (ii) Contractor : BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1) (iii) MCB : Schneider/Legrand/L&T or equivalent as per IEC-609898/IS-8828) (iv) Circuit wiring : Finolex/Polycab/RR cable or equivalent
S & F in repairs MCCB's 4 Pole 415 Volts 100 Amp 16 KA with continuously adjustable Electronic release O/L of make Legrand. Cat Part No 420015
Material and labour for taking down existing burnt copper wire of 2.5 sq.mm from junction box to light fitting and supply and fixing new cable of 2 run 2.5 sq.mm 1100 volts grade PVC insulated and sheathed cable copper conductor multi standard complete all as specified and directed by engineer in charge
S&F in replacement of Driver of LED street light 65/72/75W . Make : CG/Philips /Bajaj/Havells
S&F in replacement of Driver of LED street light 30/45W . Make :CG/ Havels/Bajaj/Philips
S&F in replacement of surge protection devices upto 75W for LED street light fitting Make : CG/Philips/Havels/Bajaj
S&F in replacement of surge protection devices upto 120/150W for LED street light fitting Make : CG/Philips/Havels/Bajaj
Supply, fixing, testing and commissioning 30W LED Street light fitting made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP66 protection. Efficacy: 110LM/W cat part No. LSTS-30-CDL-M of make Crompton or equivalent Wipro/Havells/Philips
Supply, fixing, testing and commissioning 72W LED Street light fitting made up of pressure die cast housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. 10 KV SPD included Efficacy: 110LM/W cat part No. LSTP-72-CDL-M of make Crompton or equivalent Wipro/Havells/Philips
S&F Rigid non metallic PVC conduit of external diameter 25mm exclusive with all accessories such as couplers, locks, nuts, saddles pipe hooks etc. complete all as specified.
Supply, fixing ,testing and commissioning 120W LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection. System efficacy ≥ 110 LPW. Option for 3000K 10 KV SPD included. Cat part No. LFLN-120-CDL/60-M of make Crompton or equivalent Wipro/Havells/Philips
ambika electric co
M/s.Bhavin Electricals
M/s Balaji Enterprise
J J ENTERPRISE
M/S RAJENDRA KUMAR AGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .