Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹87.2 L+₹21.3 L (32.2%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹71.3 L
EMD Value
₹50,000
Closing Date
6 Jan 2024, 6:00 pmClosed
Executive Engineer
PH Division , KWA, Vadakara
Balance Works in Vanimel grama Panchayath-Zone 1 booster-1-Pipeline Work
2024_KWA_638628_1
EE VTK 58/2023-24
Open Tender
Civil Works - Water Works
Item Rate
90 days
PH Division, KWA, Vadakara
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹50,000
Yes
1 Mar 2024
1 Jan 2024
8 Jan 2024
1 Jan 2024
6 Jan 2024
1 Jan 2024
Amount
Appendix B :- Cost of materials
100.98.234:Supply of PVC Pipe, 10kg/cm2, 63mm Dia.
100.98.235:Supply of PVC Pipe, 10kg/cm2, 75mm Dia.
100.98.237:Supply of PVC Pipe, 10kg/cm2, 110mm Dia.
OD107114/2023-2024:Supply of 50mm GI Pipe
OD134400/2023-2024:Supply Of 65mm GI Pipe
OD93430/2023-2024:Supplying best quality 100 mm dia. GI pipe ( M ) and specials as per IS specifications raferred from no.10636/AE15/2022/KWA
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.98.442:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Large Orifice Type S2, Size 20mm.
APPENDIX-A Working charges for Laying PVC Pipes of various sizes.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.12.6:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 50mm diameter nominal bore.
100.12.7:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 65mm diameter nominal bore.
100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD200243/2023-2024:Supplying and fixing 150mm CI surface box embeded with RCC slab of size 0.6x0.6x0.15 and 160mm or above size PVC 10Kg/cm2 pipe acting as protection tube with including all cost of conveyance, labour charges etc. complete
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
APPENDIX C : ROAD RESTORATION
3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)
75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)
APPENDIX D : BOOSTER
OD228552/2023-2024: Supply, erection, trial run and commissioning of vertical inline centrifugal pumpset capable of discharging 6.67 lps against a total head of 28 m with prime mover of required capacity with a working voltage of required Volts with required suitable automatic starter . Including cost of all required protection equipment, relays, cost of pump, cost of motor, Cost of panel board, cost of switch gears. cost of capacitor, cost of automatic starter. Copper cable from panel board to starter and from starter to motor, capacitor, suction pipes/delivery (up to header pipe), air valve, Non return valve and Sluice valve, pipe connection works for suction side and that at delivery side upto valves including fixing of Non return valve and Sluice valve, Air valve, Suitable earthing as per CEA regulation 2010. The pumps and valves are capable to connect online automation system.
OD228747/2023-2024:Supply, erection, trial run and commissioning of vertical inline centrifugal pumpset capable of discharging 7.40 lps against a total head of 34 m with prime mover of required capacity with a working voltage of required Volts with required suitable automatic starter . Including cost of all required protection equipment, relays, cost of pump, cost of motor, Cost of panel board, cost of switch gears. cost of capacitor, cost of automatic starter. Copper cable from panel board to starter and from starter to motor, capacitor, suction pipes/delivery (up to header pipe), air valve, Non return valve and Sluice valve, pipe connection works for suction side and that at delivery side upto valves including fixing of Non return valve and Sluice valve, Air valve, Suitable earthing as per CEA regulation 2010. The pumps and valves are capable to connect online automation system.
OD228824/2023-2024: Supply, erection, trial run and commissioning of vertical inline centrifugal pumpset capable of discharging 7.40 lps against a total head of 21 m with prime mover of required capacity with a working voltage of required Volts with required suitable automatic starter . Including cost of all required protection equipment, relays, cost of pump, cost of motor, Cost of panel board, cost of switch gears. cost of capacitor, cost of automatic starter. Copper cable from panel board to starter and from starter to motor, capacitor, suction pipes/delivery (up to header pipe), air valve, Non return valve and Sluice valve, pipe connection works for suction side and that at delivery side upto valves including fixing of Non return valve and Sluice valve, Air valve, Suitable earthing as per CEA regulation 2010. The pumps and valves are capable to connect online automation system.
OD228825/2023-2024: Supply, erection, trial run and commissioning of vertical inline centrifugal pumpset capable of discharging 5.5 lps against a total head of 27 m with prime mover of required capacity with a working voltage of required Volts with required suitable automatic starter . Including cost of all required protection equipment, relays, cost of pump, cost of motor, Cost of panel board, cost of switch gears. cost of capacitor, cost of automatic starter. Copper cable from panel board to starter and from starter to motor, capacitor, suction pipes/delivery (up to header pipe), air valve, Non return valve and Sluice valve, pipe connection works for suction side and that at delivery side upto valves including fixing of Non return valve and Sluice valve, Air valve, Suitable earthing as per CEA regulation 2010. The pumps and valves are capable to connect online automation system.
OD228830/2023-2024: Supply, erection, trial run and commissioning of vertical inline centrifugal pumpset capable of discharging 3.70 lps against a total head of 17 m with prime mover of required capacity with a working voltage of required Volts with required suitable automatic starter . Including cost of all required protection equipment, relays, cost of pump, cost of motor, Cost of panel board, cost of switch gears. cost of capacitor, cost of automatic starter. Copper cable from panel board to starter and from starter to motor, capacitor, suction pipes/delivery (up to header pipe), air valve, Non return valve and Sluice valve, pipe connection works for suction side and that at delivery side upto valves including fixing of Non return valve and Sluice valve, Air valve, Suitable earthing as per CEA regulation 2010. The pumps and valves are capable to connect online automation system.
OD227944/2023-2024:Supply erection testing and commissioning of Advanced wireless fully automatic water level controller with sump to overhead tank / Mobile operated GSM based module for operation of starters and controllers from anywhere using mobile phone .Suitable for 3 phase 5 - 10 HP motor starter, with design tested to perform reliably even in extreme environmental conditions, suitable for single phase and three phase installations, fully automatic ON/OFF with level sensors, communication with IVRS in local languages, 4 user can control the operation, power fail and feed back SMS in regional languages, four different "time of day" can be set in a day for pump operation, controls daily operations of a pump for pre-defined periods and ease of operation with advanced facilities such as auto switch off while dry run with in fraction of seconds, low voltage preventer, phase change preventer, low voltage cut off, online monitoring system etc of reputed make.etc.complete.,
OD227929/2023-2024:Providing Pump house for Vertical inline Centrifugal Pum pset including Solid block of size 40x20x15cm masonry wall , RR Foundation, PCC Floor, Metal sheet door , Roof Truss with Aluminum sheet Roof covering ,rabbit Mesh, plastering and painting etc complete as per the direction of departmental officers
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
OD227936/2023-2024:Basement for fibre tank- Including the cost of Excavation for trenches with PCC (3.2x3.2x0.15) and solid Block of size(40x20x15cm) with height 1.5m filling with contractors own earth and providing top RCC Slab of size 3x3x0.12 with reinforcement of 10mm dia @100mm c/c in both directions
RISHAD P M
Bidder Name
RISHAD P M
bidu parelmeethal
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .