Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹34.9 L+₹9.9 L (39.8%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹36.1 L+₹11.1 L (44.4%)Rejected-Finance | L3 | Rejected-Finance Reject | |
| 4 | Not Admitted-Fee/PreQual/Technical DHALIWAL | TARN TARAN | PUNJAB | 143107 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹27.4 L
EMD Value
₹48,700
Closing Date
7 May 2022, 11:00 amClosed
Executive Engineer Jal Shakti Division Nahan
Executive Engineer Jal Shakti Division Nahan
Providing, Laying and jointing of MSERW pipe of rising main and L/J of GMS pipe of rising main) Job No. I.
2022_HPIPH_60195_2
NHN-SMROO-722- 1028-1108 dated 30-04-2022
Open Tender
Pipe Laying Works
Item Rate
90 days
Nahan
Please refer Tender documents.
10 documents required · 10 mandatory
₹400
Executive Engineer Jal Shakti Division Nahan
₹48,700
Yes
15 Jun 2022
2 May 2022
7 May 2022
2 May 2022
7 May 2022
2 May 2022
Amount
Rising main
Excavation in drains and channels etc.in earth work for pipes up to all depths in all classification of earthwork such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chiseling soft / hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming & dressing of sides, leveling of beds to correct grade including shoring/struting, planking, timbering & dewatering wherever required stacking the useable/unuseable material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil/unuseable material as directed with in all leads & lifts including restoration of un-metalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with-in all leads & lifts as per directions of the Engineer Incharge.
Dismentalling of existing R/main pipe line 125mm dia i/c all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
Providing,Laying, jointing, testing & commissioning at site in trenches bevelled ended MSERW pipes of Grade "A" confirming to code IS / ISO -3183-2007 having wall thickness and per Rmt weight as mentioned below and capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with upto date ammendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site , tail pieces, tees,bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes whereever required as per site requirement i/c carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have's zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with IS/ISO 3183-2007, grade "A".The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work shall be measured & paid for separately).
S.No. From To Dia thickness
Providing, welding and fixing M.S. plate flanges of various dia. (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to MSERW/GI pipes after every 90 metres or as per site requirement including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect i/c all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
Sr No From To Dia Length in mtrs F.T
Laying, , jointing , testing & commissioning at site in trenches following plain ended GMS pipes of 125mm dia of Heavy /Medium Grade as under confirming to BIS 1239-(Part-1)-1990 or latest with up to date ammendments, capable of withstanding required test pressure as prescribed in BIS code, in randum lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt weld, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends manufactured from parent pipes etc. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts as directed by Engineer-Incharge (Earth work shall be measured & paid for seperately).
S.No. RD thickness Dia.
1. 840-1800 5.40 125mm dia(H)
2. 1800-2250 4.80 125mm dia(M)
shiv iron general engineers
viney sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .