Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹5.8 L+₹86,836 (17.7%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹6.8 L+₹1.9 L (38.0%)Rejected-Finance 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | Rejected-Technical MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | - | Rejected-Technical DOCUMENTS NOT COMPLETED | |
| 5 | Rejected-Technical DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical DOCUMENTS NOT COMPLETED |
| Sl No | Description | Qty | Unit | Bedi Refrigeration Works L2 | Tarachand gurudutt L3 | neeraj electricals L1 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for Overhauling & servicing of water cooler any capacity by carrying out the following works at different location of different establishment of Raiwala Military Camp under units complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning of storage tanks (b) Examine water tightness of stotage tank after cleaning (c) Carry out operations of stop cock, push cock, float valve etc (d) Replace washer & glands of all taps to ensure water tightness (e) Inspect over flow and remove blockage obstruction if any (f) Check and correct earth continuity of electrical items (g) Check thermostate and test its functioning (h) Inspect drain pipe and remove blockage if any (j) Check & correct all electrical wiring and its functioning (k) Testing of water coolers after repairs (l) Replacing defective spare parts NOTE :- All defective part which are required to be replaced to make functional the water cooler shall be measured and paid seperately under respective items as supply only | 10 | Each Job | 500 ₹5,000 Lowest | 500 ₹5,000 Lowest | 800 ₹8,000 |
| 2.00 | M & L for Taking down repair to water cooler storage tanks removal of leakage including soldering welding sealing condesnor motor base and arms (Stand) removed old and new 18 gauge GI sheet and arms fitting with soldering / welding with component in workshop as per requirement complete all as specified and directed by Engineer-in-charge. Note: The extra GI sheet measeured and paid on quoted rate of the contractor. | 2 | Each | 2,500 ₹5,000 | 1,000 ₹2,000 Lowest | 2,500 ₹5,000 |
| 3.00 | M & L for Disconnecting and taking out water cooler of any type any capacity and refixing the same after removal of leakage in condesnor of cooling coil including flushing dehydration refrigerant gas charging in the system including extra copper tubing complete and testing the water cooler for proper functioning in workshop complete all as specified and directed by Engineer-in-charge. Note:Required gas for testing the leakage of the system deemed to be included in the quoted rate | 2 | Each | 3,000 ₹6,000 | 1,400 ₹2,800 Lowest | 2,000 ₹4,000 |
| 4.00 | S&F in replacement of water cooler trays made out of 18 gauge GI sheet size as specified and directed by Engineer-in-charge with PVC drain pipe (not less than 2.0 mtr) and fixing in water cooler complete all as specified and directed by Engineer-in-charge | 2 | Each | 700 ₹1,400 | 600 ₹1,200 | 400 ₹800 Lowest |
| 5.00 | Supply in replacement of the following spare parts for water cooler of any make & any model duirng servicing
(a) Thermostate switch of existing make and size | 2 | Each | 250 ₹500 | 150 ₹300 Lowest | 200 ₹400 |
| 6.00 | (b) Running capacitor 30/36 mfd. Make- Tesla / Epcos / Renutrol | 2 | Each | 250 ₹500 | 400 ₹800 | 210 ₹420 Lowest |
| 7.00 | (c) Running capacitor 10/15/20 mfd. Make- Tesla / Epcos / Renutrol | 2 | Each | 85 ₹170 Lowest | 200 ₹400 | 200 ₹400 |
| 8.00 | (d) Starting capacitor 45/60/80 mfd. Make- Tesla / Epcos / Renutrol | 2 | Each | 120 ₹240 Lowest | 123 ₹246 | 180 ₹360 |
| 9.00 | (e) Starting capacitor 80/100 mfd. Make- Tesla / Epcos / Renutrol | 2 | Each | 200 ₹400 | 123 ₹246 Lowest | 200 ₹400 |
| 10.00 | (f) Starting capacitor 120/150 mfd. Make- Tesla / Epcos / Renutrol | 2 | Each | 300 ₹600 | 134 ₹268 Lowest | 250 ₹500 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
1 Jan 2025, 9:00 amClosed
AGE (I) Raiwala
AGE (I) Raiwala
REPAIR AND REPLACEMENT OF UNSV PARTS OF REFRIGERATION, WATER COLLER, AIR CONDITIONER, PACKAGE AC PLANT AND ALLIED WORK AND REPAIR AND REPLACEMENT OF EXISTING UNSV STREET LIGHT OF MIL CANT RAIWALA IN ZONE A AND B UNDER AGE (I) RAIWALA
2024_MES_686206_1
8954/E8
Open Tender
Civil Works
Works
150 days
AGE (I) Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Raiwala
₹19,000
Yes
30 Oct 2025
29 Nov 2024
4 Jan 2025
29 Nov 2024
1 Jan 2025
14 Dec 2024
29 Nov 2024 - 13 Dec 2024
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .