Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC PLOT NO 922 AND 935 SWAMI AYYAPPA COOPERATIVE SOCIETY MADHAPUR HYDERABAD HYDERABAD TELANGANA 500081 UDYAM TS 09 0016730 36AADCS4126R1ZW R M MII STATUS AS NOT VERIFIED | HYDERABAD | TELANGANA | 500081 | ₹1.7 Cr | 1 | Accepted-AOC Server cost reduced and Discount provided by the concerned company |
| 2 | ENVIRONNEMENT SA INDIA PVT LTD 2₹1.8 CrRejected-Finance | ₹1.8 Cr | 2 | Rejected-Finance As per the suggestion of Higher Purchase Committee |
| 3 | Rejected-Technical E 29 A ROAD NO 2 I P I AREA KOTA RAJASTHAN 324005 UDYAM RJ 24 0003154 08AACCA7730N1ZE R M MII STATUS AS NOT VERIFIED | KOTA | RAJASTHAN | 324005 | - | - | Rejected-Technical As per the decision of Technical Committee the Organisation has not supplied instruments in any SPCB |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
12 Feb 2020, 4:30 pmClosed
Member Secretary, TSPCB
Tripura State Pollution Control Board, Parivesh Bhawan, Gorkhabasti, Agartala, Tripura - 799006
Supply Installation Commissioning and Operation and maintenance for 5 years of Continuous Ambient Air Quality Monitoring Stations at Agartala
2020_TSPCB_7482_2
No.F.19(26)/TSPCB/ CAAQM/II/2019-20/317
Open Tender
Laboratory and scientific equipment
90 days
Tripura State Pollution Control Board, Agartala
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹20,000
18 Jun 2021
25 Jan 2020
12 Feb 2020
25 Jan 2020
12 Feb 2020
25 Jan 2020
Continuous Ambient Air Quality Monitoring Stations (CAAQMS)
Monitoring Station foundations.
Air Conditioner (5 star), Split Type, Wall mounted along with voltage stabilizer (2 X 2 ton, 1 X 1 Ton).
On line UPS (1X10KVA, 1 hr. back up and 1X5 KVA, 2 hr. back up)
Sampling System having 10 port manifold
19” Rack cabinet to accommodate all analyzers & systems
Continuous Ambient Oxides of Nitrogen (NO/NO2/ NOx) Analyzer
Continuous Ambient Ammonia (NH3) Analyzer
Continuous Ambient Sulphur Dioxide (SO2) Analyzer
Continuous Ambient Ozone (O3) Analyzer
Continuous Ambient Carbon Monoxide (CO) Analyzer
Continuous BTX Monitor / Analyzer
Multi calibration System for Gas calibration and Meteorological, Flow and Electronic Calibration
Automatic PM10 Particulate Matter Monitor
Automatic PM2.5 Particulate Matter Monitor
Meteorological Sensors for Wind Direction, Wind Speed, Ambient Temperature, Rainfall, Relative Humidity, Solar Radiation and Telescoping Crank – up Meteorological Tower
Computer System (1 PC ): a) One PC along with Laser Printer and DAS at each monitoring station;
Computer System (1 Rack Servers): a) One Central Rack Server with Cisco Switch, UTM Device & Access Point for data connectivity from Stations to be setup at each of the SPCB Head Office
Two no’s of Data display Board Transmission Device (one having size 8’/12’ and another 4’/7’) (One for Data Display Board near to the station and another for data display at the SPCB display board) (One for Data Display Board near to the station and another for data display at the SPCB display board)
Day & Night Visible Multicolour Data Display Board (Near to the station)
Day & Night Multicolour Visible Data Display Board at the respective SPCB-H.O. having size of 8’/12’
Continuous Automatic Monitoring Stations with Sampling line, Internal fitting, Instruments racks, Electrical fittings and Gas line fittings, Tools (electrical and mechanical), Data display system, Recommended spares in a Housing Container OR Continuous Automatic Monitoring Stations with Sampling line, Internal fitting, Instruments racks, Electrical fittings and Gas line fittings, Tools (electrical and mechanical), Data display system, Recommended spares without a Housing Container Quantity: One set
Continuous Automatic Monitoring Stations with Sampling line, Internal fitting, Instruments racks, Electrical fittings and Gas line fittings, Tools (electrical and mechanical), Data display system, Recommended spares in a Housing Container OR Continuous Automatic Monitoring Stations with Sampling line, Internal fitting, Instruments racks, Electrical fittings and Gas line fittings, Tools (electrical and mechanical), Data display system, Recommended spares without a Housing Container Quantity: One set w/o container
Data Card as backup of Communication system (TSPCB shall provide the internet connectivity)
RCC foundation, pillars misc works including Caging, civil & electrical work (for CAAQM stations as well as Data Display Boards)
Service charges for Operation & Maintenance including Cost of Incidental charges consisting of security, Electricity, Phones/ internet, Manpower, AMCs material including spares & consumables and other for the first year
Service charges for Operation & Maintenance including Cost of Incidental charges consisting of security, Electricity, Phones/ internet, Manpower, AMCs material including spares & consumables and other for the second year
Service charges for Operation & Maintenance including Cost of Incidental charges consisting of security, Electricity, Phones/ internet, Manpower, AMCs material including spares & consumables and other for the third year
Service charges for Operation & Maintenance including Cost of Incidental charges consisting of security, Electricity, Phones/ internet, Manpower, AMCs material including spares & consumables and other for the fourth year
Service charges for Operation & Maintenance including Cost of Incidental charges consisting of security, Electricity, Phones/ internet, Manpower, AMCs material including spares & consumables and other for the fifth year
Swan Environmental Pvt. Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid