Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.5 LAccepted-AOC PO BINNAGURI DIST JALPAIGURI WEST BENGAL PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹28.7 L+₹94,583 (3.41%)Rejected-Finance NIL | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹28.7 L+₹1.0 L (3.66%)Rejected-Finance VILL DEPOPARA BINNAGURI PO BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹29.0 L+₹1.3 L (4.79%)Rejected-Finance | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹29.4 L+₹1.7 L (5.98%)Rejected-Finance GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Jan 2024, 6:00 pmClosed
GE (NORTH) BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR MAINTENANCE OF CEILING FAN WALL MOUNTED FAN AND ALLIED WORKS AT BINNAGURI MILITARY STATION AND REPAIR REPLACEMENT OF INTERNAL WIRING INCLUDING FIXTURE AND FITTING BUILDING SECURITY LIGHT SUBMAIN POST TOP LIGHT DB AND MCB OF MD ACCN AND ARTY
2023_MES_632765_1
NIT No. 8701 / 52 / 2023-24 / 11 / E8
Open Tender
Civil Works
Item Rate
270 days
GE North Binnaguri Post Binnaguri Dist Jalpaiguri
Class D Category b (i)
8 documents required · 8 mandatory
₹500
GE (NORTH) BINNAGURI
₹96,000
Yes
31 Jan 2024
14 Dec 2023
6 Jan 2024
14 Dec 2023
4 Jan 2024
29 Dec 2023
Amount
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false ceiling/ ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosene oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavities with suitable filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as specified and as directed. Note: Spare parts wherever required to be renewed and shall be measured and paid vide under respective item as supply & fix.
Material and labour for removing the defective/burnt ceiling fans winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating materials such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete all as specified and as directed. Note: Winding shall be carried out by winding machine.
Taking down exhaust fan 300/380/450 sweep of any size from its location including disconnecting from ceiling rose, after removing carefully wall wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosene oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavities with suitable filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and refixing fan to wall in position and making electric connection complete all as specified and as directed. Note: Spare parts wherever required to be renewed and shall be measured and paid vide under respective item as supply and fix.
Material and labour for removing the defective/burnt exhaust fans of sweep 380/450 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating materials such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete all as specified and as directed. Note: Wending shall be carried out by winding machine.
Material and labour for removing the defective/burnt Exhaust fans of sweep 300 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete all as specified and as directed. Note: Wending shall be carried out by winding machine.
Taking down wall mounted / pedestal fan of 600mm sweep any size from its location including disconnecting from ceiling rose, after removing carefully false ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosene oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavities with suitable filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re-hanging fan and false ceiling in position and making electric connection complete all as directed. Note: Spare parts wherever required to be renewed and shall be measured and paid vide under respective item as supply & fix.
Material and labour for removing the defective/burnt pedestal fans of sweep 600 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete. Note: Wending shall be carried out by winding machine.
S&F in replacement of ball bearings No 6201,6202,6203, 6204 or any other size required for old vintage ceiling fans / exhaust fans/ pedestal fans complete all as specified and as directed.
S&F in replacement of bronze bush of suitable size for ceiling fans of any size and make including greasing with approved quality of grease complete all as specified and as directed.
S&F in replacement of capacitor 2.5/4.0 mfd for ceiling fan complete all as specified and as directed.
S&F in replacement of capacitor 4.0 mfd for ceiling fan complete all as specified and as directed..
S&F in replacement of fan shaft (as per existing sample) suitable for motor of ceiling fan 1200/1400 mm sweep complete all as specified and as directed.
S&F in replacement of PVC connector block 4 way with fixing nuts and clamps complete all as specified and as directed.
M&L for Painting of ceiling fans including blades with applying two coats of synthetic enameled paint over a coat of red oxide primer by using spray painting machine on old prepared surface including writing of MES No using synthetic enamel paint black colour complete all as specified and as directed.
S&F in replacement of upper canopy and down canopy for ceiling fans suitable for any make and sweep all as specified and as directed.
Supply and fixing in repair hanging clamp suitable for ceiling fans of any make and type with rubber real, nuts, bolts and washers of suitable size including locking pin complete all as specified and as directed.
S&F in replacement of Metal Fan blade suitable for Ceiling Fan 1200 mm sweep complete all as specified and as directed.
S&F in replacement of Metal Fan blade suitable up to 300 mm sweep Exhaust fan (As per existing sample) complete all as specified and as directed.
S&F in replacement of PCB Card for BLDC Remote Fan(Energy efficient) of make Havells, Orient & Bajaj complete all as specified and as directed.
Taking down existing unserviceable point wiring of any description/type/size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for reuse under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
M&L for Concealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core multi stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification) including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and as directed for the following :-
One light point controlled by one way switch 5/6 Amps complete all as specified and as directed.
One ceiling fan/Exhaust fan point controlled by one way switch 5/6 Amps complete all as specified and as directed.
One socket out let 5/6 amps point on the independent board complete all as specified and as directed.
One socket out let 5/6 amps point on the same board complete all as specified and as directed.
One bell/buzzer point controlled by one bell push button complete all as specified and as directed.
One light point controlled by two way switch 5/6 amps Complete all as specified and as directed.
All as per item No 21 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and as directed
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and as directed.
S&F switch piano flush type 5/6 Amps single pole two way complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 Amps, white ivory finish flash type complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 Pin 5/15 Amps multipurpose 230 volt flush type complete all as specified and as directed.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and as directed.
S&F switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and as directed.
S&F switch socket combination 2 in 1, 6 pin 5/6 Amps and 15/16 Amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable complete all as specified and as directed.
S&F in repair bell/buzzer push 5/6 amps flush type white/ivory finish complete all as specified and as directed.
S&F in repair ding dong bell multi music type, AC, Single pole, 220/240 Volts, surface type complete all as specified and as directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 Volts, three terminals complete all as specified and as directed.
S&F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F in repair deluxe fan electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F in replacement of LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F in repair modular switch, 1 way, 6 Amps one module complete all as specified and as directed.
S&F in repair modular swith,1 way, 16 Amps complete all as specified and as directed.
S&F in repair modular socket 6 Amp 2/3 Pin combined 2 module 230 Volts flush type complete all as specified and as directed.
S&F in repair modular socket 6/16 Amp 2/3 Pin combined 2 module 230 Volts flush type complete all as specified and as directed.
S&F in repair modular fan regulator 120W 230 Volts AC 50 Hz 2 modules complete all as specified and as directed.
S&F IP 20, Class-I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaries efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F post top lanterns 20 watt LED light fitting (warm type), outdoor new generation, energy saving, environmental friendly, long life with symmetrical light distribution, spun aluminium landscape luminaries with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and necessary mounting arrangements and taking down the old unserviceable fitting complete all as specified and as directed.
S&F recess mounting flat panel 35/36 Watt LED fitting (2'X2') for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down the old unserviceable fitting complete all as specified and as directed.
S&F energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaries with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unserviceable fitting complete all as specified and as directed.
S&F round shape LED Surface light 6 Watt fitting for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down old unserviceable fitting complete all as specified and as directed.
S&F round shape LED Surface light 12 Watt fitting for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down old unserviceable fitting complete all as specified and as directed.
S&F Decorative wall light fixture made up of polycarbonate, suitable for 20 W fitting complete with all accessories internally prewired and necessary mounting arrangement including necessary connection and taking down old unserviceable fitting complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit with and including taking down unserviceable sub main wiring, complete all as specified and as directed. Note: Two runs of sub main wiring cable along with one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/isolators complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F in replacement of MCB TPN 415 volts suitable for fixing in MCB DB of capacity 40 to 100 amps complete all as specified and as directed.
S&F sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/isolators complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F MCB, single pole & neutral, 32 Amps, 240 Volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F MCB, Single pole & neutral, 40 to 63 Amps, 240 Volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
M&L for sub main wiring with 2 run of 10.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 10.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non-metallic conduit with and including taking down unserviceable sub main wiring complete all as specified and as directed. Notes: Two runs of sub main wiring cable along with one run of earth wire with and including 25 mm dia PVC conduit pipe shall be measured as one unit length.
All as per item No 61 above but using two runs 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
Supply and fixing of Sheet metal enclosures with socket two pins and earth plug top and MCB SP-20 Amp 230 volt complete all as specified and as directed.
S&F in replacement of MCB TPN 415 Volts suitable for fixing in MCB DB of capacity 16 to 32 amps complete all as specified and as directed.
S&F Moulded case circuit breaker (MCCB) three pole adjustable type 415 volts, 50 cycles, 25 to 100 Amps of breaking capacity 36 KA with and including taking down old unserviceable one complete all as specified and as directed.
S&F LED (warm) glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 120 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 200 mm x 100 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair modular blank plates of 4 Module including taking down existing unserviceable complete all as specified and as directed.
S&F in repair modular blank plates of 6 Module including taking down existing unserviceable complete all as specified and as directed.
S&F in repair modular blank plates of 8 Module horizontal type including taking down existing unserviceable complete all as specified and as directed.
S&F wall mounted 4 feet LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to ceiling rose complete all as specified and as directed.
S&F wall mounted 4 feet LED tube light(Warm) fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to ceiling rose complete all as specified and as directed.
S&F LED colour coordinated 5 m RGB strip with light travel function with IR , 24 W of along the surface on wall/ceiling /floor of the open shed and making suitable electric connection to it complete all as specified and as directed.
M&L for LED garden light 09 Watt made up of high grade unbreakable polycarbonate material , IP 65 protection , cone series innovative design with uniformly lit diffuser at the upper portion including taking out old unsv garden light fittings complete all as specified and as directed.
S&F energy saving new generation 9/10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed.
S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and as directed.
S&F in repair socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
S&F in repair Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and directed.
S&F of Bulk head luminaries suitable for 10 Watt LED (or nearest next higher wattage) light IP66 grade, luminaries efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 4 Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 6 Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion complete all as specified and as directed.
SHRI PRADEEP PARIK
M/S D S CONSTRUCTION CO
M/S S.K.DAS
Shri Amarnath Sah
M/s. MD IRSHAD
samrat saw mill and joinery workshop
SINGH & CO
L. B. SHARMA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .