Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.0 CrAccepted-AOC | ₹8.0 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹8.2 CrRejected-AOC | ₹8.2 Cr | 2 | Rejected-AOC L2 |
| 3 | 3₹8.4 CrRejected-AOC | ₹8.4 Cr | 3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Radha Subbiah Infra Private Limited L3 | CCMV INFRA PRIVATE LIMITED L2 | Madhava Eswar Infrastructure Private Limited L1 |
|---|---|---|---|---|---|---|
| 1.00Bill No. 1. Construction of 10LL UGT at Ezhil Nagar | ||||||
| 2.00Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, murum, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil as per SS 20B with initial lead of 10m and lift of 2m | ||||||
| 3.00 | 0 - 2m | 727 | cum | 160 ₹1.2 L | 140 ₹1.0 L | 293 ₹2.1 L |
| 4.00 | 2 - 3m | 364 | cum | 180 ₹65,520 | 150 ₹54,600 | 320 ₹1.2 L |
| 5.00 | 3 - 4m | 46 | cum | 200 ₹9,200 | 170 ₹7,820 | 320 ₹14,720 |
| 6.00 | Supplying and filling with sand for foundation and basement as per standard specification including watering, consolidating, ramming etc. complete. | 65 | cum | 2,000 ₹1.3 L | 1,980 ₹1.3 L | 1,750 ₹1.1 L |
| 7.00C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick including ramming, curing etc. complete | ||||||
| 8.00 | at 1.5-4.5m depth below GL | 66 | cum | 7,300 ₹4.8 L | 6,370 ₹4.2 L | 5,850 ₹3.9 L |
| 9.00 | Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3 m high | 1,221 | sqm | 1,600 ₹19.5 L | 1,390 ₹17.0 L | 1,130 ₹13.8 L |
| 10.00Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete. | ||||||
Updated dates
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
29 Jan 2026, 3:00 pmClosed
Superintending Engineer (C and M)
Office of Superintending Engineer, Contracts Monitoring, 4th Floor, CMWSS Board, No.1, Pumping Station Road, Chintadripet, Chennai 600 002
Construction of water distribution stations of capacity 10LL 1 no. and 5LL 2 nos and Providing 200mm dia DI dedicated main for Ezhil Nagar tenements in Depot 195 and 196, Area XV
2025_CMWSS_634524_1
CNT/WSS/NCB/DEP/3708/2025-26
Open Tender
Civil Works - Water Works
Chennai
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹4.1 L
4th floor, tender opening hall
21 May 2026
19 Dec 2025
30 Jan 2026
19 Dec 2025
29 Jan 2026
9 Jan 2026
26 Dec 2025
Bill No. 1. Construction of 10LL UGT at Ezhil Nagar
Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, murum, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil as per SS 20B with initial lead of 10m and lift of 2m
Supplying and filling with sand for foundation and basement as per standard specification including watering, consolidating, ramming etc. complete.
C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick including ramming, curing etc. complete
at 1.5-4.5m depth below GL
Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3 m high
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
upto 1.5 m below GL
upto 1.5 m above GL
1.5-4.5m below G.L.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works (Fe-500 D Grade with CRS material)
Granolithic flooring 50 mm thick with cement concrete 1:2:4 using 3 to 10 mm chips and top surface rendered smooth with cement including thread lining 25mm dia G.I.pipe of necessary length for water outlet, curing etc. complete.
Stock brick work with II class brick in cement mortar 1:3 for 23 cm thick wall including curing etc. complete.
Providing and fixing LS cover and frame of size 60x60cm including necessary masonry work and plastering etc complete.
Supplying and fixing of 100mm dia CI ventilating pipe of 0.5m length each with 100mm dia A.C vent cowl (slotted type)
Supplying and fixing of 200mm width 16 gauge GI plate for construction jointing.
Bailing out of sub-soil water (provision for 3 - 4m depth of earthwork excavation). Hire charges for diesel pumpset above 3HP to 7.5 HP
Testing of the UGT by retaining water for 48 hours inside the UGT including cost of water pumping water into the UGT and bailing out of water (after testing ) with necessary pumping equipments including attending the crack if any occurred during the test
Refilling with excavated soils (other than sand) complying with standard specification for filling in foundation and basement.
Disposal of surplus earth
Pile foundation
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural Bored Cast in Situ Piles witha minimum cement content of 400 kg/cu.m under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows: 10mm -32 mm dia rod (Fe-500 D Grade with CRS material)
Labour charges for only Boring and installation of 650mm dia RCC bored cast in situ piles depth measured from existing ground level including boring in hard starts inclulding tools,plants and all consumable Etc
Labour charges for only Boring and installation of 500mm dia RCC bored cast in situ piles depth measured from existing ground level including boring & socketing in hard stratas/ Rock inclulding tools,plants and all consumable Etc
Testing of piles : Intergrity test on all piles
Testing of piles : Static load test on working pile : Rs. 1000 per tonne
Bill No. 2. SUCTION AND DELIVERY ARRANGEMENTS FROM THE PROPOSED 10LL UGT AT EZHIL NAGAR
Pipes and specials from UGT
Suction side
300x200mm D/F DI taper
300mm DI D/Fl 90 deg bend
300mm D/Fl 3m length pipes
300mm CI bell mouth
Delivery side
250x150 mm D/F DI taper
250mm DI D/Fl pipe 0.50m length
250mm D/Fl pipe 1m length
250 mm DI D/Fl pipe 2.5m long
250x250mm DI A/Fl tee
250x150mm DI FL/Double soc tee
250mm DI D/Fl 90 deg bend
250 mm DI D/Fl 90 deg duckfoot bend
250 mm DI Fl/ Spi Tailpiece
250 mm DI Fl/ Soc Tailpiece
250 mm DI blank flange
Supplying and delivery at site, conveying and fixing CI sluice valves (PN 1.0) of following sizes conforming to IS:including loading, unloading, Transportation charges and stacking at the site etc complete as per specifications.
250mm CI Non return valves
250 mm CI Sluice valves with actuator
250 mm CI Sluice valve with actuator
150 mm dia Sluice valve
150 mm dia Double air valve
Supply, delivery , laying and jointing D.I. Pipes of the following sizes of socket @ spigot end, push - on - joint DI pipes of classification K9 conforming to IS: 8329/2000 in standard lengths with cement mortar lining inside and outside Zinc coating, including Labour charges for loading, unloading and stacking at the site etc., including earthwork excavation for trenches in hard stiff clay, black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10m and initial lift of 2m conveying to the site of work, lowering into the trenches, and aligning, jointing, refilling the trenches with excavated soil, watering and ramming to consolidation, disposal of surplus earth etc., complete for the pipes of following diametres @ 2.0m depth.
250mm DI soc/spi pipe 5.5m long
Jointing the D.I. Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete (including cost of jointing materials) (mm)
Testing of DI pipes with hydraulic testing equipment by filling with water and testing to recommended pressure in convenient stetches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for the following diametres of pipes.
Construction of thrust blocks
250mm DI D/Fl 90 deg bend
Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soil as per SS20B with initial lead of 10mts. and lift of 2m etc. complete. 0 - 2m
Supplying and filling with sand for foundation and basement as per standard specification
C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick, ramming, curing etc. complete
Stock Brick work in cement mortar 1:4 using second class bricks including curing etc complete.
For over 23cm thick wall
For 23cm thick wall
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M20 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing etc., as per standard specification and as directed by the departmental officers complete
Supplying, fabricating and laying in position MS or RTS rods for RCC works including cost of steel, binding wire, cutting, cranking and tying in position with binding wire assembly etc., complete for well kerb, well steining and raft.
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete complying with standard specifications
Supplying and fixing CI steps etc complete.
Plastering with C.M 1:3 for 20mm thick
Plastering with C.M 1:3 for 12mm thick
Cement concrete 1:2:4 using 20mm gauge hard broken stone jelly for plain cement concrete work including laying, compacting curing etc., complete.
Providing and fixing L.S. cover and frame of size 60cm x 60cm including necessary masonry work and plastering etc., complete.
Disposal of surplus earth
Refilling with excavated earth
Bill No.4 Construction of Pump House at Ezhil Nagar 10LL UGT
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete I) upto 3m high
II) Above 3m high
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the Board officers complete.
(i) Upto 1.5m (upto Plinth level) above and below GL
ii) Ground floor (1.5 to 4.5m)
Sun shade laying CC 1:2:4 for RCC sun shade works using 20mm BG jelly 100mm thick at wall end and 80mm thick at free end and projecting 900mm from the wall face moulded along with RC lintels and tiled into the full thickness of wall where there are no lintels excluding cost of reinforcement but including centering, shuttering, compacting, curing and finishing etc. complete.
Supplying, fabricating and laying in position M.S. rounds or RTS rods for RCC works including cost of reinforcement, binding wire, cutting, bending, cranking and tying in position with binding wire etc. complete
Stock brick work in cement mortar 1:4 using second class bricks including curing etc. complete for 23 cm thick wall
upto 1.5m from G.L.
Ground floor
Stock brick work in cement mortar 1:4 using second class bricks including curring etc. complete for 11cm thick wall.
Plastering with C.M 1:3 for 12mm thick including curing etc. complete
Special ceiling plastering 10mm thick with C.M. 1:3 for RCC slabs and beams including hacking and curing etc., complete.
Flooring with 100mm thick base cement concrete 1:4:10 using 40mm gauge, hard broken stone jelly including laying ramming, curing, etc., complete.
Paving hydraulic pressed cement mosaic tiles of approved colour and of size 20cm x 20cm x 20mm finished thickness with small verona of indian marble chips (other than Salem magnesite) with cement mortar 1:3 - 20mm thick and pointed with the same coloured cement including polishing with power polisher, to a high degree of polish so as to be perfectly smooth and glossy with grey colour mosaic tiles
Terrace flooring with two course of flat tiles of 15cm x 15cm x 12 mm using cement mortar 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar
Weathering course concrete with broken brick jelly 20mm guage in pure slacked lime over RCC roof slab in proportion of 32:12 1/2 (no sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
Best Indian TW cupboard with frames 100 x 60mm alround and shutters 40mm thick with moulded panels in 20mm thick planks and 4nos of iron hold fasts fixed in CC 1:2:4 using 3-10mm chips 6 nos of butt hinges 100mm long including necessary fittings brass padlock 100mm long of suitable size and suitable brass handles, screws etc complete The cupboard will have 4nos of RCC precast slabs 40mm thick and 40mm bearing at sides neatly packed with CM etc. and firmly fixed in position. The RCC work will be 1:2:4 mix using stone jelly 6-10mm gauge with necessary reinforcement and rendered smooth with CM on all faces, curing etc complete The rear face of the cupboard will be 50mm thick using country bricks in CM 1:4.
Supplying and erecting rolling shutters of 76mm, 18 guage of galvanized steel sheet with push and pull or self coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside etc. complete and painting with priming coat of redoxide without lock (Payment will be made only for actual opening of shutters are rolled up wherever the shutters are to be fixed)
Aluminium openable type window size 1.2m x 1.3m : Maufacturing supplying and fixing in position Anodised Alu. Natural colour mat finish with openable type window with extruded Alu. Sections with two panels of size (Frame - 38 x 33 x21 x 2.4mm @ 0.615 Kg/m, Shutter: Bottom, Top - 38.5 x 33 x 24.5 x 3 & 4mm @ 0.706 Kg/m, Interlocking vertical - 59 x 33 x 25 x 2.5mm @ 1.135 Kg/m) with necessary accessaries such as rubber beadings best quality of lock handle hinges,stays and fixing 4 mm thick plain / frosted/ pin headed glass including cost of all materials labour for electrical consumption required for drilling holes in RCC columns, beams, masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing as directed by the Board officers.The Al.Surfaces is to be anodised with matt finish usder electrically condition in accordance with ISI1868/1962 specification for an average anodic film thick of not less than 15 microns. (All materials should be got approved by the Site Engineer before fixing in position)
Aluminium Door Single Leaf Size 2.1m X 1.0m: Supplying, fabricating and fixing in position of Alumi.Anod.natural colour matt finish door half glazed and half PLB board using 12 mm thick PLB board and 5.5 mm thick glazed door using rectangular Alu.Box section of size (Frame : Section - 101.60 x 44.45 x 3.18 mm @ 2.399 Kg/m, Shutter : Top, Middle, Vertical style- 50 x 44.45 x 2.5mm @ 1.292 Kg/m, Bottom - 100 x 44.45 x2.5mm @ 1.974 Kg/m) with necessary accessories such as rubber beading, Al. Clips, Best double action floor springs, Aluminium Handles on both sides,floor stopper,Tower bolt, Locks and glass including all materials,Labour, power consemption charges required for fabrication if necessary chipping, dismantling making necessary holes in RCC Coloums, Beams or Masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc.,complete. The Alumi. surface must be anodised with matt finish under electrically controlled condition in accordance with IS specification 1868 / 1962 of Anodic filthickness of not less than 15 Microns (Fifteen) for all sections.All the materials should be got approved by the Site Engineer before fixing as directed.
Supplying & fixing door shutters for Medium Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive of three coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete.
Supplying and fixing in position of aluminium anodised colour matt finish Louvered Ventilator. The outer frame will be 62x38x2mm @ 1.17 Kg / m and the louvers with moving arrangements will be made with Alu. Channel of size 60x30x4 mm @ 1.27 kg /m with necessary glass pans for louvers 4mm thick Al. Clips, including all materials, labour & power consumption charges required for fabrication if necessary chipping dismantling making holes in RCC columns,beams or masonry wherever necessary with power drill to the extent required and make good to the original conditions after fixing etc., complete. The Aluminium surface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than15 microns (fifteen) for all sections. All the materials should be got approved by the Site Engineer before fixing in position as directed.
Supplying and fixing M.S. grills for window and gate including one coat of primer with red lead etc. complete as directed.
Colour washing two coats over one coat of white washing.
White washing three coats.
Painting with superior quality ready mixed paint of chocolate, light green grey or any other approved colour for new iron works two coats
Supplying, and fixing 100mm AC down fall pipe including cost of 100mm AC pipe, shoe bend, bracket and teek wood plugs, grating etc. complete with door arrangments
Precast slab in RCC 1:2:4 using 12 to 20 mm B.G jelly including laying, ramming, curing etc. complete for covering the cable trench as instructed at site.
Supply, fabrication, erection and fixing in position of gantry girder along with rails using ISMB 250 @ and ISMC 150 for gantry girder of length 16m - 2 nos, supported by corbels at 4m c/c, including all machineries and labour charges etc complete as directed at site.
Supply, fabrication, erection and fixing in position of manually operated geared travelling trolley with 2 tonne capacity Pulley block for a span of 3m including lifting chain 9m and other necessary arrangements etc.complete.
Refilling with excavated soil (other than sand) compling with standard specification for filling in foundation and basement etc. complete
Disposal of surplus earth including loading, unloading and carting to the place as directed at site etc complete
Bill No.5 WATER SUPPLY AND SANITARY ARRANGEMENTS
SANITARY ARRANGEMENTS
Supplying and fixing 51 cm white glazed water closet pan with P or S trap including WG foot rests and supplying, laying 100mm dia SWP, concrete encasing the pan and complete finishing of W.C. appurtenances etc., complete.
Providing and fixing 100 mm dia CI soil or vent pipe
Providing and fixing 100mm dia AC Vent Cowl (slotted type)
Providing and fixing 50 mm dia CI soil pipe bend without door arrangements
Providing and fixing 100mm dia CI soil pipe bend without door arrangements
Providing and fixing 50 mm dia CI soil or vent pipe
Providing and fixing 15 x 10 cm SW gully trap with CI gratings in BJ concrete in CM 1:4:10 with silt pit diaphragm arrangements etc., complete.
Supplying, laying jointing and testing 100mm dia SW pipe including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10m. lowering the pipes into the trenches, aligning, refilling the trenches with excavated earth in layers of not more than 23cm thick watering, ramming to consolidation and disposal of surplus earth etc., complete at an average depth of 2.0m
Construction of inspection chambers of following sizes with earthwork excavation for foundation with 23cm thick brick jelly cement concrete bed in CM 1:4:10 using 40mm brick jelly for foundation, brick work in CM 1:6 for chamber, plastering with CM 1:3, 12 mm thick, benching, channelling, 75mm thick RCC loose slab covering in cement concrete 1:2:4 mix using 20 mm blue granite jelly including necessary reinforcement etc. complete. a. 60cm x 60cm x 75cm
b. 60cm x 60cm x 60cm
WATER SUPPLY ARRANGEMENTS
Supplying and fixing 55cm x 40cm laboratory wash basin white glazed with lead and brass connection CP pillar tap, lead waste pipe, C.P plug with single chain, etc., complete.
Supplying and fixing best mirror of size 60cmx45cm of 6mm thick with plywood back including necessary fittings, etc., complete
Supplying and fixing C.P towel rails 45cmx 20mm
Supplying GI pipes and specials of the following sizes including cutting threading and jointing with necessary specials including carting the materials, fixing to wall with necessary clamps and screws, making holes in roof, repacking the same with necessary brickwork and plastering wherever necessary with scaffolding etc, complete for 25mm GI pipe
Supplying and fixing 25 mm GM Gate Valve
Supplying and fixing 20mm C.P. Screw down Tap
Boring and tapping mains and fixing brass screw plugs or ferrules of size 15mm
Supply and delivery and fixing of HDPE tank 1000 litres capacity as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Supply and delivery of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively.
Bill no.6. SUPPLY, DELIVERY, ERECTION & COMMISSIONING OF ELECTRICALLY DRIVEN HORIZONTALLY SPLIT CASE WATER SUPPLY PUMPSETS WITH ALLIED ELECTRICAL WORKS FOR EZHIL NAGAR 10LL WDS
Supply, delivery, erection, testing and commissioning of electrically driven, water lubricated horizontal split case water supply pumpset with bronze impellers, other accessories suitable for following duty point, including required capacity 3Ph, 415 V, AC, 50 Hz, TEFC, squirrel cage induction motor, on a common base plate, with suitable starter, fasteners including incidental civilworks etc. complete.
UNIT- 1 - 7850 lpm against a total head of 25 m
Supply, delivery, erection, testing and commissioning of vacuum pump of suitable capacity to prime the above pump, including required capacity 3 Ph, 415 V, AC, 50 Hz, Electrical Motor along with a common base plate for the pump and motor, coupling pulley, suitable starter, fasteners including incidental civil works and connecting with the suction pipe of the above pump sets including supply of necessary materials and labour etc.complete as instructed at site.
Vacuum Pump - 10 HP
Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete.
UNIT- 1 - 20 kVAR
Vacuum Pump - 4 kVAR
Supplying and fixing of 200 Amps Triple Pole fuse carrier in MS Sheet steel encloure with provision for accommodating the TNEB meter including earthing etc., complete.
Supplying and fixing of 200 Amps Triple Pole FSU with HRC fuses on suitable angle iron frame with earth connection only.
Capacity of M.V. Panel - 200 Amps
200 A FP Motorised Online Change over Switch 25 kA
150 A TP MCCB 25 kA for UNIT- 1
32 A TP MCCB 25 kA for Vacuum Pump
63 A TP MCCB 25kA (for UNIT- 1 cap.)
32 A TP MCCB 25kA (for Vacuum Pump cap.)
63 A TP MCCB 35kA (for PLC Panel)
32 A TPN MCB 10kA (for LDB)
Capacity of D.G. Set - 63 kVA
Supplying and clamping of variuos sizes of PVC insulated PVC sheathed armoured aluminium LT UG cable by MS clamps on wall or in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed.
From 200 Fuse Carriers to 200 Amps SFU & from there to 200 Amps MCCB Switch of MV panel (Wall)
size 3.5C, 150 Sqmm
From existing Control Panel of DG to 100A MCCB of MV Panel (Under ground)
size 3.5C, 50 Sqmm
From 150 A MCCB of MV Panel to Control Panel of UNIT- 1 (Wall)
size 3.5C, 95 Sqmm
From Control Panel of UNIT- 1 to motor (Wall)
size 3C, 95 Sqmm
From Starter in MV Panel to Vacuum Pump (Wall)
size 3C, 6 Sqmm
From 63 A MCCB of MV Panel to UNIT- 1 Capacitors (Wall)
size 3C, 25 Sqmm
From 32 A MCCB of MV Panel to Vacuum Pump Capacitor (Wall)
size 3C, 6 Sqmm
From 32A MCB of MV Panel to PLC Panel & LDB (Wall) size 4 core 10 sq.mm
From control Panel of Pump to Local P.B. Station & for automation size 3 core 2.5 sq.mm copper (Under ground)
From control Panel of Pump to Local P.B. Station size 3 core 2.5 sq.mm copper (Wall)
Supplying and fixing of cable gland and termination with Al. cable lugsfor the following sizes of PVC insulated PVC sheathed armoured alumunium LT UG cable and with earth connection.
size 3.5C, 150 Sqmm (EB)
size 3.5C, 50 Sqmm (DG)
Size 3.5C, 95 sq.mm (UNIT- 1)
Size 3C, 6 sq.mm (Vacuum Pump)
size 3C, 25 Sqmm (UNIT- 1 capacitor)
size 3C, 6 Sqmm (Vacuum Pump capacitor)
Size 4 core 10 sq.mm PLC Panel and LDB
size 3 core 2.5 sq.mm copper
Supply, delivery and fixing of dust and vermin proof Local Push Button station near the pumpset with 1 No"ON" and 1 No "OFF" push buttons (the "OFF" push button shall be locable in "OFF" position).
Supply, delivery and erection of Three Phase 6 way 32 Amps, 10kA LDB with the following: 1 No of 40 A FP isolator for incoming supply 3 Nos. of 16A, DP RCCB 3 Nos. of 16A, SP MCB 1 No of 16A, DP MCB 3 Nos of 6A, DP MCB in sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete.
Run of 2 of 2.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket.
Wiring with 2.5 sq mm PVC insulated single core copper cables of 650 V Grade on suitable rigid PVC pipe on wall and ceiling with PVC accessories, with MS switch box covered with 3 mm thick hylam sheet with continous earth wire connection of 14 SWG TC wire.
Light points
Fan Points
Wiring with 2.5 sq.mm PVC unsheathed single core copper cable on suitable rigid PVC pipe for 5A 3 pin CS plug non interlocking including supply and fixing of plug pin top in MS box with continuous earth connection by 14 SWG TC wire.
Lighting Fixtures
Supply and installation of 215 V - 1 x 40 W Flouresent TL fitting box type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.
Supply and installation of 215 V - 2 x 40 W Flouresent TL fitting industrial type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.
Supply and fixing of water tight bulk head fitting suitable for 100W bulb with lamp guard and lamp.
Supplying and fixing of 12" sweep AC exhaust fan complete including providing necessary opening in the wall.
Supply and fixing of 48" sweep AC ceiling fan complete with regulator with lm down rod (stem pipe) including supplying and fixing of fan clamp with side plates and cross arms.
a) Supply and erection of 1 No 3" dia 2 m long tubular Wall Mounted post with complete 250W sodium vapour lampwith necessary fitting and other accessories etc.
Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm
Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
Supplying and fixing of 15 amps, single phase, DP SFU switch with F&N on suitable TW Board with earth connection only
Supply and erection of 1 No 3" dia 5 m long tubular Pole Mounted post with complete 250W sodium vapour lampwith necessary fitting and other accessories etc.
Supplying and laying of PVC , LTUG cable under ground in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed for 2 core 4 sq.mm
Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm
Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
Supply and delivery of the following safety equipment a) 5 kg capacity ISI marked dry chemical powder type fire extinguisher
First Aid box ( medium)
Fire bucket - 3 Nos with MS stand
Rubber mat 6mmthick of 1.1 kv grade of size 2m x 1m
Fire safety rules chart
Shock treatment chart
"Caution / Danger" Board
Supply and delivery of the following tools:
Double ended open jaw spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 20x23 24x27, 25x28 & 30x32
Ring spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22 20x23 24x27, 25x28 & 30x32.
Screw driver of size 12 inches
Cutting plier of size 8 inches
Tong Tester ( clamp on type- multiutility) A C voltage 0 - 750 V AC current 0 - 1000 A D C voltage 0 - 1000 V Resistance 0 - 40 mega ohms
Electrical tester
Diesel Filling Pump (Hand operated )
Measuring Dip Rod (MS) (for measuring 200 ltr. standard Barrel )
Hack Saw frame with blade
Lever type Grease gun
Supply and delivery of Rechargeable emergency lamp with 600mm Fluorocuent lamp, dry type rechargable battery etc.,complete.
Earthing as per ISI specifications with necessary masonary work
Supply and connection of earthing conductor including two coats of approved painting and laying between earth pit and equipments
25 x 6 mm GI Flat
40 x 6 mm GI Flat
Supply, Delivery, erection, testing and commissioning of PLC Control Panel including the Remote Terminal Unit/ Programmable Logic Controller (RTU/PLC), Human Machine Interface (HMI), GPRS modem, 1 kVA UPS and accessories along with mounting assembly & cables including installing the PLC programming package and interconnecting with the existing SCADA System at Centralized Monitoring Location (the software will be provided by CMWSSB) as directed by Engineer and interconnecting with the ultrasonic level transmitters, electromagnetic flow meters and with existing MV panels, Capacitor panels at each sewage Pumping Station to switch ON/OFF the pumps based on level feedback, Switch ON/OFF the existing capacitor bank to maintain Powerfactor as per EB norms, and to monitor EB/ DG supply including incidental civil works etc., complete.
Supply, Delivery, erection, testing and commissioning of Ultrasonic Level Transmitter of range 0 - 15 meters in the UGT and OHT of the hed works with necessary mounting arrangements including incidental civil works etc complete.
Operation and maintenance of the installation: Operation and maintenanceof the plant with all auxiliary equipment for a period of 120 days after satisfactory supply, erection , commissioning and operating the entire plant for 30 days, free of cost by the contractor before handing over the plant to the Board.
Bill no.7 Supply,delivery, installation and testing of 200mm dia Electromagnetic flow meter for Inlet of 10LL WDS
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast /Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished as per the details provided in the specificaion (Volume -II)
Specials for Electromagnetic FlowMeter
200 mm F/Spi Tail Piece
200 mm F/Soc Tail Piece
Jointing the DI Socket/spicot specials with rubber gasket(Tyton joint) including cost of jointing materials etc. complete.
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts including the cost of jointing materials etc. complete.
Cutting of DI Pipes true to axis and finishing the ends complete .
Bill no.8 Supply,delivery, installation and testing of 250mm dia Electromagnetic flow meter for Outlet of 10LL WDS
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast /Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished as per the details provided in the specificaion (Volume -II)
Supply, delivery , conveying and fixing DI D/F pipes as per IS:8329/2000 and DI SS/DF specials like Tee, Bends ,Tapers and Tailpieces as per IS:9523/2000 including loading,unloading and stacking at the site excluding earthwork excavation as directed by the Engineer at site etc complete.
Specials for Electromagnetic FlowMeter
250 mm F/Spi Tail Piece
250 mm F/Soc Tail Piece
Jointing the DI Socket/spicot specials with rubber gasket(Tyton joint) including cost of jointing materials etc. complete.
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts including the cost of jointing materials etc. complete.
Cutting of DI Pipes true to axis and finishing the ends complete .
Bill No. 9. CONSTRUCTION OF 5 LAKH LITRES CAPACITY UGT at Ezhil Nagar1st Cross Street
Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, murum, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil as per SS 20B with initial lead of 10m and lift of 2m
Supplying and filling with sand for foundation and basement as per standard specification including watering, consolidating, ramming etc. complete.
C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick including ramming, curing etc. complete
at 1.5-4.5m depth below GL
Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3 m high
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
upto 1.5 m below GL
upto 1.5 m above GL
1.5-4.5m below G.L.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works (Fe-500 D Grade with CRS material)
Granolithic flooring 50 mm thick with cement concrete 1:2:4 using 3 to 10 mm chips and top surface rendered smooth with cement including thread lining 25mm dia G.I.pipe of necessary length for water outlet, curing etc. complete.
Stock brick work with II class brick in cement mortar 1:3 for 23 cm thick wall including curing etc. complete.
Providing and fixing LS cover and frame of size 60x60cm including necessary masonry work and plastering etc complete.
Supplying and fixing of 100mm dia CI ventilating pipe of 0.5m length each with 100mm dia A.C vent cowl (slotted type)
Supplying and fixing of 200mm width 16 gauge GI plate for construction jointing.
Bailing out of sub-soil water (provision for 3 - 4m depth of earthwork excavation). Hire charges for diesel pumpset above 3HP to 7.5 HP
Testing of the UGT by retaining water for 48 hours inside the UGT including cost of water pumping water into the UGT and bailing out of water (after testing ) with necessary pumping equipments including attending the crack if any occurred during the test
Refilling with excavated soils (other than sand) complying with standard specification for filling in foundation and basement.
Disposal of surplus earth
Pile foundation
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural Bored Cast in Situ Piles witha minimum cement content of 400 kg/cu.m under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows: 10mm -32 mm dia rod (Fe-500 D Grade with CRS material)
Labour charges for only Boring and installation of 500mm dia RCC bored cast in situ piles depth measured from existing ground level including boring & socketing in hard stratas/ Rock inclulding tools,plants and all consumable Etc
Testing of piles : Intergrity test on all piles
Testing of piles : Static load test on working pile : Rs. 1000 per tonne
Bill No. 10. SUCTION AND DELIVERY ARRANGEMENTS FROM THE PROPOSED 5LL UGT AT EZHIL NAGAR 1ST CROSS STREET
Pipes and specials from UGT
Suction side
200x150mm D/F DI taper
250mm DI D/Fl 90 deg bend
250mm D/Fl 2.0m length pipes
250mm D/Fl 3m length pipes
250mm CI bell mouth
200x125 mm D/F DI taper
150x200mm D/F DI taper
150mm DI D/Fl pipe 0.50m length
200mm D/Fl pipe 1m length
200 mm DI D/Fl pipe 2.5m long
200x150mm DI A/Fl tee
200x150mm DI FL/Double soc tee
200mm DI D/Fl 90 deg bend
200 mm DI D/Fl 90 deg duckfoot bend
200 mm DI Fl/ Spi Tailpiece
200 mm DI Fl/ Soc Tailpiece
200 mm DI blank flange
Supplying and delivery at site, conveying and fixing CI sluice valves (PN 1.0) of following sizes conforming to IS:including loading, unloading, Transportation charges and stacking at the site etc complete as per specifications.
150mm CI Non return valves
150 mm CI Sluice valves
200 mm CI Sluice valve
150 mm dia Sluice valve
150 mm dia Double air valve
Supply, delivery , laying and jointing D.I. Pipes of the following sizes of socket @ spigot end, push - on - joint DI pipes of classification K9 conforming to IS: 8329/2000 in standard lengths with cement mortar lining inside and outside Zinc coating, including Labour charges for loading, unloading and stacking at the site etc., including earthwork excavation for trenches in hard stiff clay, black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10m and initial lift of 2m conveying to the site of work, lowering into the trenches, and aligning, jointing, refilling the trenches with excavated soil, watering and ramming to consolidation, disposal of surplus earth etc., complete for the pipes of following diametres @ 2.0m depth.
200mm DI soc/spi pipe 5.5m long
Jointing the D.I. Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete (including cost of jointing materials) (mm)
Testing of DI pipes with hydraulic testing equipment by filling with water and testing to recommended pressure in convenient stetches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for the following diametres of pipes.
Construction of thrust blocks
200mm DI D/Fl 90 deg bend
Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soil as per SS20B with initial lead of 10mts. and lift of 2m etc. complete. 0 - 2m
Supplying and filling with sand for foundation and basement as per standard specification
C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick, ramming, curing etc. complete
Stock Brick work in cement mortar 1:4 using second class bricks including curing etc complete.
For over 23cm thick wall
For 23cm thick wall
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M20 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing etc., as per standard specification and as directed by the departmental officers complete
Supplying, fabricating and laying in position MS or RTS rods for RCC works including cost of steel, binding wire, cutting, cranking and tying in position with binding wire assembly etc., complete for well kerb, well steining and raft.
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete complying with standard specifications
Supplying and fixing CI steps etc complete.
Plastering with C.M 1:3 for 20mm thick
Plastering with C.M 1:3 for 12mm thick
Cement concrete 1:2:4 using 20mm gauge hard broken stone jelly for plain cement concrete work including laying, compacting curing etc., complete.
Providing and fixing L.S. cover and frame of size 60cm x 60cm including necessary masonry work and plastering etc., complete.
Disposal of surplus earth
Refilling with excavated earth
Bill No.12 Construction of Pump House Ezhil Nagar 1st Cross Street 5LL WDS
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete I) upto 3m high
II) Above 3m high
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the Board officers complete.
(i) Upto 1.5m (upto Plinth level) above and below GL
ii) Ground floor (1.5 to 4.5m)
Sun shade laying CC 1:2:4 for RCC sun shade works using 20mm BG jelly 100mm thick at wall end and 80mm thick at free end and projecting 900mm from the wall face moulded along with RC lintels and tiled into the full thickness of wall where there are no lintels excluding cost of reinforcement but including centering, shuttering, compacting, curing and finishing etc. complete.
Supplying, fabricating and laying in position M.S. rounds or RTS rods for RCC works including cost of reinforcement, binding wire, cutting, bending, cranking and tying in position with binding wire etc. complete
Stock brick work in cement mortar 1:4 using second class bricks including curing etc. complete for 23 cm thick wall
upto 1.5m from G.L.
Ground floor
Stock brick work in cement mortar 1:4 using second class bricks including curring etc. complete for 11cm thick wall.
Plastering with C.M 1:3 for 12mm thick including curing etc. complete
Special ceiling plastering 10mm thick with C.M. 1:3 for RCC slabs and beams including hacking and curing etc., complete.
Flooring with 100mm thick base cement concrete 1:4:10 using 40mm gauge, hard broken stone jelly including laying ramming, curing, etc., complete.
Paving hydraulic pressed cement mosaic tiles of approved colour and of size 20cm x 20cm x 20mm finished thickness with small verona of indian marble chips (other than Salem magnesite) with cement mortar 1:3 - 20mm thick and pointed with the same coloured cement including polishing with power polisher, to a high degree of polish so as to be perfectly smooth and glossy with grey colour mosaic tiles
Terrace flooring with two course of flat tiles of 15cm x 15cm x 12 mm using cement mortar 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar
Weathering course concrete with broken brick jelly 20mm guage in pure slacked lime over RCC roof slab in proportion of 32:12 1/2 (no sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
Best Indian TW cupboard with frames 100 x 60mm alround and shutters 40mm thick with moulded panels in 20mm thick planks and 4nos of iron hold fasts fixed in CC 1:2:4 using 3-10mm chips 6 nos of butt hinges 100mm long including necessary fittings brass padlock 100mm long of suitable size and suitable brass handles, screws etc complete The cupboard will have 4nos of RCC precast slabs 40mm thick and 40mm bearing at sides neatly packed with CM etc. and firmly fixed in position. The RCC work will be 1:2:4 mix using stone jelly 6-10mm gauge with necessary reinforcement and rendered smooth with CM on all faces, curing etc complete The rear face of the cupboard will be 50mm thick using country bricks in CM 1:4.
Supplying and erecting rolling shutters of 76mm, 18 guage of galvanized steel sheet with push and pull or self coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside etc. complete and painting with priming coat of redoxide without lock (Payment will be made only for actual opening of shutters are rolled up wherever the shutters are to be fixed)
Aluminium openable type window size 1.2m x 1.3m : Maufacturing supplying and fixing in position Anodised Alu. Natural colour mat finish with openable type window with extruded Alu. Sections with two panels of size (Frame - 38 x 33 x21 x 2.4mm @ 0.615 Kg/m, Shutter: Bottom, Top - 38.5 x 33 x 24.5 x 3 & 4mm @ 0.706 Kg/m, Interlocking vertical - 59 x 33 x 25 x 2.5mm @ 1.135 Kg/m) with necessary accessaries such as rubber beadings best quality of lock handle hinges,stays and fixing 4 mm thick plain / frosted/ pin headed glass including cost of all materials labour for electrical consumption required for drilling holes in RCC columns, beams, masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing as directed by the Board officers.The Al.Surfaces is to be anodised with matt finish usder electrically condition in accordance with ISI1868/1962 specification for an average anodic film thick of not less than 15 microns. (All materials should be got approved by the Site Engineer before fixing in position)
Aluminium Door Single Leaf Size 2.1m X 1.0m: Supplying, fabricating and fixing in position of Alumi.Anod.natural colour matt finish door half glazed and half PLB board using 12 mm thick PLB board and 5.5 mm thick glazed door using rectangular Alu.Box section of size (Frame : Section - 101.60 x 44.45 x 3.18 mm @ 2.399 Kg/m, Shutter : Top, Middle, Vertical style- 50 x 44.45 x 2.5mm @ 1.292 Kg/m, Bottom - 100 x 44.45 x2.5mm @ 1.974 Kg/m) with necessary accessories such as rubber beading, Al. Clips, Best double action floor springs, Aluminium Handles on both sides,floor stopper,Tower bolt, Locks and glass including all materials,Labour, power consemption charges required for fabrication if necessary chipping, dismantling making necessary holes in RCC Coloums, Beams or Masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc.,complete. The Alumi. surface must be anodised with matt finish under electrically controlled condition in accordance with IS specification 1868 / 1962 of Anodic filthickness of not less than 15 Microns (Fifteen) for all sections.All the materials should be got approved by the Site Engineer before fixing as directed.
Supplying & fixing door shutters for Medium Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive of three coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete.
Supplying and fixing in position of aluminium anodised colour matt finish Louvered Ventilator. The outer frame will be 62x38x2mm @ 1.17 Kg / m and the louvers with moving arrangements will be made with Alu. Channel of size 60x30x4 mm @ 1.27 kg /m with necessary glass pans for louvers 4mm thick Al. Clips, including all materials, labour & power consumption charges required for fabrication if necessary chipping dismantling making holes in RCC columns,beams or masonry wherever necessary with power drill to the extent required and make good to the original conditions after fixing etc., complete. The Aluminium surface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than15 microns (fifteen) for all sections. All the materials should be got approved by the Site Engineer before fixing in position as directed.
Supplying and fixing M.S. grills for window and gate including one coat of primer with red lead etc. complete as directed.
Colour washing two coats over one coat of white washing.
White washing three coats.
Painting with superior quality ready mixed paint of chocolate, light green grey or any other approved colour for new iron works two coats
Supplying, and fixing 100mm AC down fall pipe including cost of 100mm AC pipe, shoe bend, bracket and teek wood plugs, grating etc. complete with door arrangments
Precast slab in RCC 1:2:4 using 12 to 20 mm B.G jelly including laying, ramming, curing etc. complete for covering the cable trench as instructed at site.
Supply, fabrication, erection and fixing in position of gantry girder along with rails using ISMB 250 @ and ISMC 150 for gantry girder of length 16m - 2 nos, supported by corbels at 4m c/c, including all machineries and labour charges etc complete as directed at site.
Supply, fabrication, erection and fixing in position of manually operated geared travelling trolley with 2 tonne capacity Pulley block for a span of 3m including lifting chain 9m and other necessary arrangements etc.complete.
Refilling with excavated soil (other than sand) compling with standard specification for filling in foundation and basement etc. complete
Disposal of surplus earth including loading, unloading and carting to the place as directed at site etc complete
Bill No.13 WATER SUPPLY AND SANITARY ARRANGEMENTS
SANITARY ARRANGEMENTS
Supplying and fixing 51 cm white glazed water closet pan with P or S trap including WG foot rests and supplying, laying 100mm dia SWP, concrete encasing the pan and complete finishing of W.C. appurtenances etc., complete.
Providing and fixing 100 mm dia CI soil or vent pipe
Providing and fixing 100mm dia AC Vent Cowl (slotted type)
Providing and fixing 50 mm dia CI soil pipe bend without door arrangements
Providing and fixing 100mm dia CI soil pipe bend without door arrangements
Providing and fixing 50 mm dia CI soil or vent pipe
Providing and fixing 15 x 10 cm SW gully trap with CI gratings in BJ concrete in CM 1:4:10 with silt pit diaphragm arrangements etc., complete.
Supplying, laying jointing and testing 100mm dia SW pipe including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10m. lowering the pipes into the trenches, aligning, refilling the trenches with excavated earth in layers of not more than 23cm thick watering, ramming to consolidation and disposal of surplus earth etc., complete at an average depth of 2.0m
Construction of inspection chambers of following sizes with earthwork excavation for foundation with 23cm thick brick jelly cement concrete bed in CM 1:4:10 using 40mm brick jelly for foundation, brick work in CM 1:6 for chamber, plastering with CM 1:3, 12 mm thick, benching, channelling, 75mm thick RCC loose slab covering in cement concrete 1:2:4 mix using 20 mm blue granite jelly including necessary reinforcement etc. complete. a. 60cm x 60cm x 75cm
b. 60cm x 60cm x 60cm
WATER SUPPLY ARRANGEMENTS
Supplying and fixing 55cm x 40cm laboratory wash basin white glazed with lead and brass connection CP pillar tap, lead waste pipe, C.P plug with single chain, etc., complete.
Supplying and fixing best mirror of size 60cmx45cm of 6mm thick with plywood back including necessary fittings, etc., complete
Supplying and fixing C.P towel rails 45cmx 20mm
Supplying GI pipes and specials of the following sizes including cutting threading and jointing with necessary specials including carting the materials, fixing to wall with necessary clamps and screws, making holes in roof, repacking the same with necessary brickwork and plastering wherever necessary with scaffolding etc, complete for 25mm GI pipe
Supplying and fixing 25 mm GM Gate Valve
Supplying and fixing 20mm C.P. Screw down Tap
Boring and tapping mains and fixing brass screw plugs or ferrules of size 15mm
Supply and delivery and fixing of HDPE tank 1000 litres capacity as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Supply and delivery of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively.
Bill No.14 Construction of compound wall at Ezhil Nagar 5LL UGT at Ezhil Nagar 1st Cross Street
Clearing heavy jungle
Earthwork excavation and depositing on bank with initial lead of 10 metres and initial lift 2.00m (in all type of strata) in hard stiff clay stiff black cotton, hard red earth, shales, Muram, gravel, stoney earth and earth mixed with small size boulders S.S. 20-B. (excluding timbering and bailing out sub-soil water) as per P.W.D. standard schedule of rates for Chennai City.
Upto 2.0 m below GL
Supplying and filling M-sand for foundation and basement including watering, consolidating, ramming etc. complete.
Cement concrete 1:3:6 using Crushed stone sand (M-sand) and 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete
Upto 1.5 m below GL
From 1.5 m to 4.5 m below GL
Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3m high
Upto 3 m above and below GL
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using Crushed stone sand (M-sand) and 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the Board officers complete.
Upto 1.5 m below GL
Upto 1.5 m above GL
From 1.5 m to 4.5 m above GL
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows
Stock brick work with II class bricks in cement mortor 1:5 (Crushed stone sand (M-sand)) for 23 cm thick walls including curing etc. complete.
Upto 1.5 m above GL
From 1.5 m to 4.5 m above GL
Band course work flat 10mm to 12mm thick and 50mm deep with C.M. 1:3 (Crushed stone sand (M-sand) including curing, etc., complete as directed
Cement concrete 1:3:6 using Crushed stone sand (M-sand) and 12-20mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete
20mm thick sand faced cement plaster on wall upto hight 10 meters above ground level consisting of 12mm thick backing coat of CM 1:3 ( 1 cement : 3 sand ) and 8mm thick finishing coat of CM 1:1 ( 1 cement : 1 sand ) etc complete
Colour washing two coats over one coat of white washing
Supplying and fixing barbed wire fencing over the proposed compound wall with ‘L’ angle iron 50 x 50 x 6mm & 1.45m posts bent to shape at 2.5m centres with 6 rows of barbed wire and also in a zig zag manner at 25cm c.c. connecting all the rows with barbed wire will be of 2 ply and 12 gauge or other approved size including drilling hole in ‘L’ iron posts and fixing the posts in cement concrete 1:2:4 of size 15x15x45cm etc as directed.
Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations and basement
Disposal of surplus earth
Supplying and fabricating and erection of iron gate with of required size as per direction at site with G.I pipes of 50 mm and specials at all sides and 40x40x6mm angles as bracing on which 2 No.of m.s sheet of 16 gauge of size 2x2m each is welded as two halves fixing letter ''METROWATER' including one coat of primer with red lead etc.compete as directed.
Painting with two coats of ready mixed plastic emulsion paint first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt, etc., complete and including necessaary plaster of paris, putty, etc., wherever required.
Providing and fixing gardening items on site as directed.
Pile foundation
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural Bored Cast in Situ Piles witha minimum cement content of 400 kg/cu.m under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows: 10mm -32 mm dia rod (Fe-500 D Grade with CRS material)
Labour charges for only Boring and installation of 450mm dia RCC bored cast in situ piles depth measured from existing ground level including boring & socketing in hard stratas/ Rock inclulding tools,plants and all consumable Etc
Testing of piles : Intergrity test on all piles
Testing of piles : Static load test on working pile : Rs. 1000 per tonne
Bill no.15 Providing pumping machineries & allied works at the proposed 5 LL UGT at Ezhil Nagar 1st Cross Street
Supply, delivery, erection, testing and commissioning of electrically driven, water lubricated horizontal split case water supply pumpset with bronze impellers, other accessories suitable for following duty point, including required capacity 3Ph, 415 V, AC, 50 Hz, TEFC, squirrel cage induction motor, on a common base plate, with suitable starter, fasteners including incidental civilworks etc. complete.
UNIT- 1 - 2760 lpm against a total head of 25 m
Supply, delivery, erection, testing and commissioning of vacuum pump of suitable capacity to prime the above pump, including required capacity 3 Ph, 415 V, AC, 50 Hz, Electrical Motor along with a common base plate for the pump and motor, coupling pulley, suitable starter, fasteners including incidental civil works and connecting with the suction pipe of the above pump sets including supply of necessary materials and labour etc.complete as instructed at site.
Vacuum Pump - 5 HP
Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete.
UNIT- 1 - 9 kVAR
Vacuum Pump - 2 kVAR
Supplying and fixing of 100 Amps Triple Pole fuse carrier in MS Sheet steel encloure with provision for accommodating the TNEB meter including earthing etc., complete.
Supplying and fixing of 100 Amps Triple Pole FSU with HRC fuses on suitable angle iron frame with earth connection only.
Capacity of M.V. Panel - 100 Amps
100 A FP Motorised Online Change over Switch 25 kA
63 A TP MCCB 25 kA for UNIT- 1
16 A TP MCCB 25 kA for Vacuum Pump
63 A TP MCCB 25kA (for UNIT- 1 cap.)
16 A TP MCCB 25kA (for Vacuum Pump cap.)
63 A TP MCCB 35kA (for PLC Panel)
32 A TPN MCB 10kA (for LDB)
Capacity of D.G. Set - 50 kVA
Supplying and clamping of variuos sizes of PVC insulated PVC sheathed armoured aluminium LT UG cable by MS clamps on wall or in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed.
From 100 Fuse Carriers to 100 Amps SFU & from there to 100 Amps MCCB Switch of MV panel (Wall)
size 3.5C, 50 Sqmm
From existing Control Panel of DG to 75A MCCB of MV Panel (Under ground)
size 3.5C, 35 Sqmm
From 63 A MCCB of MV Panel to Control Panel of UNIT- 1 (Wall)
size 3.5C, 25 Sqmm
From Control Panel of UNIT- 1 to motor (Wall)
size 3C, 25 Sqmm
From Starter in MV Panel to Vacuum Pump (Wall)
size 3C, 6 Sqmm
From 63 A MCCB of MV Panel to UNIT- 1 Capacitors (Wall)
size 3C, 10 Sqmm
From 16 A MCCB of MV Panel to Vacuum Pump Capacitor (Wall)
size 3C, 6 Sqmm
From 32A MCB of MV Panel to PLC Panel & LDB (Wall) size 4 core 10 sq.mm
From control Panel of Pump to Local P.B. Station & for automation size 3 core 2.5 sq.mm copper (Under ground)
From control Panel of Pump to Local P.B. Station size 3 core 2.5 sq.mm copper (Wall)
Supplying and fixing of cable gland and termination with Al. cable lugsfor the following sizes of PVC insulated PVC sheathed armoured alumunium LT UG cable and with earth connection.
size 3.5C, 50 Sqmm (EB)
size 3.5C, 35 Sqmm (DG)
Size 3.5C, 25 sq.mm (UNIT- 1)
Size 3C, 6 sq.mm (Vacuum Pump)
size 3C, 10 Sqmm (UNIT- 1 capacitor)
size 3C, 6 Sqmm (Vacuum Pump capacitor)
Size 4 core 10 sq.mm PLC Panel and LDB
size 3 core 2.5 sq.mm copper
Supply, delivery and fixing of dust and vermin proof Local Push Button station near the pumpset with 1 No"ON" and 1 No "OFF" push buttons (the "OFF" push button shall be locable in "OFF" position).
Supply, delivery and erection of Three Phase 6 way 32 Amps, 10kA LDB with the following: 1 No of 40 A FP isolator for incoming supply 3 Nos. of 16A, DP RCCB 3 Nos. of 16A, SP MCB 1 No of 16A, DP MCB 3 Nos of 6A, DP MCB in sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete.
Run of 2 of 2.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket.
Wiring with 2.5 sq mm PVC insulated single core copper cables of 650 V Grade on suitable rigid PVC pipe on wall and ceiling with PVC accessories, with MS switch box covered with 3 mm thick hylam sheet with continous earth wire connection of 14 SWG TC wire.
Light points
Fan Points
Wiring with 2.5 sq.mm PVC unsheathed single core copper cable on suitable rigid PVC pipe for 5A 3 pin CS plug non interlocking including supply and fixing of plug pin top in MS box with continuous earth connection by 14 SWG TC wire.
Lighting Fixtures
Supply and installation of 215 V - 1 x 40 W Flouresent TL fitting box type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.
Supply and installation of 215 V - 2 x 40 W Flouresent TL fitting industrial type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.
Supply and fixing of water tight bulk head fitting suitable for 100W bulb with lamp guard and lamp.
Supplying and fixing of 12" sweep AC exhaust fan complete including providing necessary opening in the wall.
Supply and fixing of 48" sweep AC ceiling fan complete with regulator with lm down rod (stem pipe) including supplying and fixing of fan clamp with side plates and cross arms.
a) Supply and erection of 1 No 3" dia 2 m long tubular Wall Mounted post with complete 250W sodium vapour lampwith necessary fitting and other accessories etc.
Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm
Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
Supplying and fixing of 15 amps, single phase, DP SFU switch with F&N on suitable TW Board with earth connection only
Supply and erection of 1 No 3" dia 5 m long tubular Pole Mounted post with complete 250W sodium vapour lampwith necessary fitting and other accessories etc.
Supplying and laying of PVC , LTUG cable under ground in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed for 2 core 4 sq.mm
Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm
Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
Supply and delivery of the following safety equipment a) 5 kg capacity ISI marked dry chemical powder type fire extinguisher
First Aid box ( medium)
Fire bucket - 3 Nos with MS stand
Rubber mat 6mmthick of 1.1 kv grade of size 2m x 1m
Fire safety rules chart
Shock treatment chart
"Caution / Danger" Board
Supply and delivery of the following tools:
Double ended open jaw spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 20x23 24x27, 25x28 & 30x32
Ring spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22 20x23 24x27, 25x28 & 30x32.
Screw driver of size 12 inches
Cutting plier of size 8 inches
Tong Tester ( clamp on type- multiutility) A C voltage 0 - 750 V AC current 0 - 1000 A D C voltage 0 - 1000 V Resistance 0 - 40 mega ohms
Electrical tester
Diesel Filling Pump (Hand operated )
Measuring Dip Rod (MS) (for measuring 200 ltr. standard Barrel )
Hack Saw frame with blade
Lever type Grease gun
Supply and delivery of Rechargeable emergency lamp with 600mm Fluorocuent lamp, dry type rechargable battery etc.,complete.
Earthing as per ISI specifications with necessary masonary work
Supply and connection of earthing conductor including two coats of approved painting and laying between earth pit and equipments
25 x 6 mm GI Flat
40 x 6 mm GI Flat
Supply, Delivery, erection, testing and commissioning of PLC Control Panel including the Remote Terminal Unit/ Programmable Logic Controller (RTU/PLC), Human Machine Interface (HMI), GPRS modem, 1 kVA UPS and accessories along with mounting assembly & cables including installing the PLC programming package and interconnecting with the existing SCADA System at Centralized Monitoring Location (the software will be provided by CMWSSB) as directed by Engineer and interconnecting with the ultrasonic level transmitters, electromagnetic flow meters and with existing MV panels, Capacitor panels at each sewage Pumping Station to switch ON/OFF the pumps based on level feedback, Switch ON/OFF the existing capacitor bank to maintain Powerfactor as per EB norms, and to monitor EB/ DG supply including incidental civil works etc., complete.
Supply, Delivery, erection, testing and commissioning of Ultrasonic Level Transmitter of range 0 - 15 meters in the UGT and OHT of the hed works with necessary mounting arrangements including incidental civil works etc complete.
Operation and maintenance of the installation: Operation and maintenanceof the plant with all auxiliary equipment for a period of 120 days after satisfactory supply, erection , commissioning and operating the entire plant for 30 days, free of cost by the contractor before handing over the plant to the Board.
Bill no. 16 Supply,delivery, installation and testing of 200mm dia Electromagnetic flow meters for Inlet Ezhil Nagar 1st Cross Streeet 5 LL WDS
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast /Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished as per the details provided in the specificaion (Volume -II)
Specials for Electromagnetic FlowMeter
200 mm F/Spi Tail Piece
200 mm F/Soc Tail Piece
Jointing the DI Socket/spicot specials with rubber gasket(Tyton joint) including cost of jointing materials etc. complete.
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts including the cost of jointing materials etc. complete.
Cutting of DI Pipes true to axis and finishing the ends complete .
Bill no. 17 Supply,delivery, installation and testing of 200mm dia Electromagnetic flow meters for Outlet Ezhil Nagar 1st Cross Streeet 5 LL WDS
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast /Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished as per the details provided in the specificaion (Volume -II)
Specials for Electromagnetic FlowMeter
200 mm F/Spi Tail Piece
200 mm F/Soc Tail Piece
Jointing the DI Socket/spicot specials with rubber gasket(Tyton joint) including cost of jointing materials etc. complete.
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts including the cost of jointing materials etc. complete.
Cutting of DI Pipes true to axis and finishing the ends complete .
Bill no.18 CONSTRUCTION OF 5 LAKH LITRES CAPACITY UGT Ezhil Nagar 1st Main Road
Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, murum, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil as per SS 20B with initial lead of 10m and lift of 2m
Supplying and filling with sand for foundation and basement as per standard specification including watering, consolidating, ramming etc. complete.
C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick including ramming, curing etc. complete
at 1.5-4.5m depth below GL
Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3 m high
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
upto 1.5 m below GL
upto 1.5 m above GL
1.5-4.5m below G.L.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works (Fe-500 D Grade with CRS material)
Granolithic flooring 50 mm thick with cement concrete 1:2:4 using 3 to 10 mm chips and top surface rendered smooth with cement including thread lining 25mm dia G.I.pipe of necessary length for water outlet, curing etc. complete.
Stock brick work with II class brick in cement mortar 1:3 for 23 cm thick wall including curing etc. complete.
Providing and fixing LS cover and frame of size 60x60cm including necessary masonry work and plastering etc complete.
Supplying and fixing of 100mm dia CI ventilating pipe of 0.5m length each with 100mm dia A.C vent cowl (slotted type)
Supplying and fixing of 200mm width 16 gauge GI plate for construction jointing.
Bailing out of sub-soil water (provision for 3 - 4m depth of earthwork excavation). Hire charges for diesel pumpset above 3HP to 7.5 HP
Testing of the UGT by retaining water for 48 hours inside the UGT including cost of water pumping water into the UGT and bailing out of water (after testing ) with necessary pumping equipments including attending the crack if any occurred during the test
Refilling with excavated soils (other than sand) complying with standard specification for filling in foundation and basement.
Disposal of surplus earth
Pile foundation
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural Bored Cast in Situ Piles witha minimum cement content of 400 kg/cu.m under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows: 10mm -32 mm dia rod (Fe-500 D Grade with CRS material)
Labour charges for only Boring and installation of 500mm dia RCC bored cast in situ piles depth measured from existing ground level including boring & socketing in hard stratas/ Rock inclulding tools,plants and all consumable Etc
Testing of piles : Intergrity test on all piles
Testing of piles : Static load test on working pile: Rs.1000 per tonne
Bill No. 19.SUCTION AND DELIVERY ARRANGEMENTS FROM THE PROPOSED 5LL UGT AT EZHIL NAGAR 1ST MAIN ROAD
Pipes and specials from UGT
Suction side
200x150mm D/F DI taper
250mm DI D/Fl 90 deg bend
250mm D/Fl 2.0m length pipes
250mm D/Fl 3m length pipes
250mm CI bell mouth
200x125 mm D/F DI taper
150x200mm D/F DI taper
150mm DI D/Fl pipe 0.50m length
200mm D/Fl pipe 1m length
200 mm DI D/Fl pipe 2.5m long
200x150mm DI A/Fl tee
200x150mm DI FL/Double soc tee
200mm DI D/Fl 90 deg bend
200 mm DI D/Fl 90 deg duckfoot bend
200 mm DI Fl/ Spi Tailpiece
200 mm DI Fl/ Soc Tailpiece
200 mm DI blank flange
Supplying and delivery at site, conveying and fixing CI sluice valves (PN 1.0) of following sizes conforming to IS:including loading, unloading, Transportation charges and stacking at the site etc complete as per specifications.
150mm CI Non return valves
150 mm CI Sluice valves
200 mm CI Sluice valve
150 mm dia Sluice valve
150 mm dia Double air valve
Supply, delivery , laying and jointing D.I. Pipes of the following sizes of socket @ spigot end, push - on - joint DI pipes of classification K9 conforming to IS: 8329/2000 in standard lengths with cement mortar lining inside and outside Zinc coating, including Labour charges for loading, unloading and stacking at the site etc., including earthwork excavation for trenches in hard stiff clay, black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10m and initial lift of 2m conveying to the site of work, lowering into the trenches, and aligning, jointing, refilling the trenches with excavated soil, watering and ramming to consolidation, disposal of surplus earth etc., complete for the pipes of following diametres @ 2.0m depth.
200mm DI soc/spi pipe 5.5m long
Jointing the D.I. Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete (including cost of jointing materials) (mm)
Testing of DI pipes with hydraulic testing equipment by filling with water and testing to recommended pressure in convenient stetches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for the following diametres of pipes.
Construction of thrust blocks
200mm DI D/Fl 90 deg bend
Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soil as per SS20B with initial lead of 10mts. and lift of 2m etc. complete. 0 - 2m
Supplying and filling with sand for foundation and basement as per standard specification
C.C 1:3:6 using 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15 cm, thick, ramming, curing etc. complete
Stock Brick work in cement mortar 1:4 using second class bricks including curing etc complete.
For over 23cm thick wall
For 23cm thick wall
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M20 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing etc., as per standard specification and as directed by the departmental officers complete
Supplying, fabricating and laying in position MS or RTS rods for RCC works including cost of steel, binding wire, cutting, cranking and tying in position with binding wire assembly etc., complete for well kerb, well steining and raft.
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete complying with standard specifications
Supplying and fixing CI steps etc complete.
Plastering with C.M 1:3 for 20mm thick
Plastering with C.M 1:3 for 12mm thick
Cement concrete 1:2:4 using 20mm gauge hard broken stone jelly for plain cement concrete work including laying, compacting curing etc., complete.
Providing and fixing L.S. cover and frame of size 60cm x 60cm including necessary masonry work and plastering etc., complete.
Disposal of surplus earth
Refilling with excavated earth
Bill No.21 Construction of Pump House at Ezhil Nagar 1st Main Road 5LL WDS
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete I) upto 3m high
II) Above 3m high
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the Board officers complete.
(i) Upto 1.5m (upto Plinth level) above and below GL
ii) Ground floor (1.5 to 4.5m)
Sun shade laying CC 1:2:4 for RCC sun shade works using 20mm BG jelly 100mm thick at wall end and 80mm thick at free end and projecting 900mm from the wall face moulded along with RC lintels and tiled into the full thickness of wall where there are no lintels excluding cost of reinforcement but including centering, shuttering, compacting, curing and finishing etc. complete.
Supplying, fabricating and laying in position M.S. rounds or RTS rods for RCC works including cost of reinforcement, binding wire, cutting, bending, cranking and tying in position with binding wire etc. complete
Stock brick work in cement mortar 1:4 using second class bricks including curing etc. complete for 23 cm thick wall
upto 1.5m from G.L.
Ground floor
Stock brick work in cement mortar 1:4 using second class bricks including curring etc. complete for 11cm thick wall.
Plastering with C.M 1:3 for 12mm thick including curing etc. complete
Special ceiling plastering 10mm thick with C.M. 1:3 for RCC slabs and beams including hacking and curing etc., complete.
Flooring with 100mm thick base cement concrete 1:4:10 using 40mm gauge, hard broken stone jelly including laying ramming, curing, etc., complete.
Paving hydraulic pressed cement mosaic tiles of approved colour and of size 20cm x 20cm x 20mm finished thickness with small verona of indian marble chips (other than Salem magnesite) with cement mortar 1:3 - 20mm thick and pointed with the same coloured cement including polishing with power polisher, to a high degree of polish so as to be perfectly smooth and glossy with grey colour mosaic tiles
Terrace flooring with two course of flat tiles of 15cm x 15cm x 12 mm using cement mortar 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar
Weathering course concrete with broken brick jelly 20mm guage in pure slacked lime over RCC roof slab in proportion of 32:12 1/2 (no sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
Best Indian TW cupboard with frames 100 x 60mm alround and shutters 40mm thick with moulded panels in 20mm thick planks and 4nos of iron hold fasts fixed in CC 1:2:4 using 3-10mm chips 6 nos of butt hinges 100mm long including necessary fittings brass padlock 100mm long of suitable size and suitable brass handles, screws etc complete The cupboard will have 4nos of RCC precast slabs 40mm thick and 40mm bearing at sides neatly packed with CM etc. and firmly fixed in position. The RCC work will be 1:2:4 mix using stone jelly 6-10mm gauge with necessary reinforcement and rendered smooth with CM on all faces, curing etc complete The rear face of the cupboard will be 50mm thick using country bricks in CM 1:4.
Supplying and erecting rolling shutters of 76mm, 18 guage of galvanized steel sheet with push and pull or self coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside etc. complete and painting with priming coat of redoxide without lock (Payment will be made only for actual opening of shutters are rolled up wherever the shutters are to be fixed)
Aluminium openable type window size 1.2m x 1.3m : Maufacturing supplying and fixing in position Anodised Alu. Natural colour mat finish with openable type window with extruded Alu. Sections with two panels of size (Frame - 38 x 33 x21 x 2.4mm @ 0.615 Kg/m, Shutter: Bottom, Top - 38.5 x 33 x 24.5 x 3 & 4mm @ 0.706 Kg/m, Interlocking vertical - 59 x 33 x 25 x 2.5mm @ 1.135 Kg/m) with necessary accessaries such as rubber beadings best quality of lock handle hinges,stays and fixing 4 mm thick plain / frosted/ pin headed glass including cost of all materials labour for electrical consumption required for drilling holes in RCC columns, beams, masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing as directed by the Board officers.The Al.Surfaces is to be anodised with matt finish usder electrically condition in accordance with ISI1868/1962 specification for an average anodic film thick of not less than 15 microns. (All materials should be got approved by the Site Engineer before fixing in position)
Aluminium Door Single Leaf Size 2.1m X 1.0m: Supplying, fabricating and fixing in position of Alumi.Anod.natural colour matt finish door half glazed and half PLB board using 12 mm thick PLB board and 5.5 mm thick glazed door using rectangular Alu.Box section of size (Frame : Section - 101.60 x 44.45 x 3.18 mm @ 2.399 Kg/m, Shutter : Top, Middle, Vertical style- 50 x 44.45 x 2.5mm @ 1.292 Kg/m, Bottom - 100 x 44.45 x2.5mm @ 1.974 Kg/m) with necessary accessories such as rubber beading, Al. Clips, Best double action floor springs, Aluminium Handles on both sides,floor stopper,Tower bolt, Locks and glass including all materials,Labour, power consemption charges required for fabrication if necessary chipping, dismantling making necessary holes in RCC Coloums, Beams or Masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc.,complete. The Alumi. surface must be anodised with matt finish under electrically controlled condition in accordance with IS specification 1868 / 1962 of Anodic filthickness of not less than 15 Microns (Fifteen) for all sections.All the materials should be got approved by the Site Engineer before fixing as directed.
Supplying & fixing door shutters for Medium Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive of three coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete.
Supplying and fixing in position of aluminium anodised colour matt finish Louvered Ventilator. The outer frame will be 62x38x2mm @ 1.17 Kg / m and the louvers with moving arrangements will be made with Alu. Channel of size 60x30x4 mm @ 1.27 kg /m with necessary glass pans for louvers 4mm thick Al. Clips, including all materials, labour & power consumption charges required for fabrication if necessary chipping dismantling making holes in RCC columns,beams or masonry wherever necessary with power drill to the extent required and make good to the original conditions after fixing etc., complete. The Aluminium surface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than15 microns (fifteen) for all sections. All the materials should be got approved by the Site Engineer before fixing in position as directed.
Supplying and fixing M.S. grills for window and gate including one coat of primer with red lead etc. complete as directed.
Colour washing two coats over one coat of white washing.
White washing three coats.
Painting with superior quality ready mixed paint of chocolate, light green grey or any other approved colour for new iron works two coats
Supplying, and fixing 100mm AC down fall pipe including cost of 100mm AC pipe, shoe bend, bracket and teek wood plugs, grating etc. complete with door arrangments
Precast slab in RCC 1:2:4 using 12 to 20 mm B.G jelly including laying, ramming, curing etc. complete for covering the cable trench as instructed at site.
Supply, fabrication, erection and fixing in position of gantry girder along with rails using ISMB 250 @ and ISMC 150 for gantry girder of length 16m - 2 nos, supported by corbels at 4m c/c, including all machineries and labour charges etc complete as directed at site.
Supply, fabrication, erection and fixing in position of manually operated geared travelling trolley with 2 tonne capacity Pulley block for a span of 3m including lifting chain 9m and other necessary arrangements etc.complete.
Refilling with excavated soil (other than sand) compling with standard specification for filling in foundation and basement etc. complete
Disposal of surplus earth including loading, unloading and carting to the place as directed at site etc complete
Bill No.22 WATER SUPPLY AND SANITARY ARRANGEMENTS for Ezhil Nagar 5LL at 1st main Road
SANITARY ARRANGEMENTS
Supplying and fixing 51 cm white glazed water closet pan with P or S trap including WG foot rests and supplying, laying 100mm dia SWP, concrete encasing the pan and complete finishing of W.C. appurtenances etc., complete.
Providing and fixing 100 mm dia CI soil or vent pipe
Providing and fixing 100mm dia AC Vent Cowl (slotted type)
Providing and fixing 50 mm dia CI soil pipe bend without door arrangements
Providing and fixing 100mm dia CI soil pipe bend without door arrangements
Providing and fixing 50 mm dia CI soil or vent pipe
Providing and fixing 15 x 10 cm SW gully trap with CI gratings in BJ concrete in CM 1:4:10 with silt pit diaphragm arrangements etc., complete.
Supplying, laying jointing and testing 100mm dia SW pipe including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10m. lowering the pipes into the trenches, aligning, refilling the trenches with excavated earth in layers of not more than 23cm thick watering, ramming to consolidation and disposal of surplus earth etc., complete at an average depth of 2.0m
Construction of inspection chambers of following sizes with earthwork excavation for foundation with 23cm thick brick jelly cement concrete bed in CM 1:4:10 using 40mm brick jelly for foundation, brick work in CM 1:6 for chamber, plastering with CM 1:3, 12 mm thick, benching, channelling, 75mm thick RCC loose slab covering in cement concrete 1:2:4 mix using 20 mm blue granite jelly including necessary reinforcement etc. complete. a. 60cm x 60cm x 75cm
b. 60cm x 60cm x 60cm
WATER SUPPLY ARRANGEMENTS
Supplying and fixing 55cm x 40cm laboratory wash basin white glazed with lead and brass connection CP pillar tap, lead waste pipe, C.P plug with single chain, etc., complete.
Supplying and fixing best mirror of size 60cmx45cm of 6mm thick with plywood back including necessary fittings, etc., complete
Supplying and fixing C.P towel rails 45cmx 20mm
Supplying GI pipes and specials of the following sizes including cutting threading and jointing with necessary specials including carting the materials, fixing to wall with necessary clamps and screws, making holes in roof, repacking the same with necessary brickwork and plastering wherever necessary with scaffolding etc, complete for 25mm GI pipe
Supplying and fixing 25 mm GM Gate Valve
Supplying and fixing 20mm C.P. Screw down Tap
Boring and tapping mains and fixing brass screw plugs or ferrules of size 15mm
Supply and delivery and fixing of HDPE tank 1000 litres capacity as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Supply and delivery of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively.
Bill No.23 Construction of compound wall at Ezhil Nagar 5LL UGT at Ezhil Nagar 1st Main Road
Clearing heavy jungle
Earthwork excavation and depositing on bank with initial lead of 10 metres and initial lift 2.00m (in all type of strata) in hard stiff clay stiff black cotton, hard red earth, shales, Muram, gravel, stoney earth and earth mixed with small size boulders S.S. 20-B. (excluding timbering and bailing out sub-soil water) as per P.W.D. standard schedule of rates for Chennai City.
Upto 2.0 m below GL
Supplying and filling M-sand for foundation and basement including watering, consolidating, ramming etc. complete.
Cement concrete 1:3:6 using Crushed stone sand (M-sand) and 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete
Upto 1.5 m below GL
From 1.5 m to 4.5 m below GL
Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3m high
Upto 3 m above and below GL
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using Crushed stone sand (M-sand) and 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the Board officers complete.
Upto 1.5 m below GL
Upto 1.5 m above GL
From 1.5 m to 4.5 m above GL
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows
Stock brick work with II class bricks in cement mortor 1:5 (Crushed stone sand (M-sand)) for 23 cm thick walls including curing etc. complete.
Upto 1.5 m above GL
From 1.5 m to 4.5 m above GL
Band course work flat 10mm to 12mm thick and 50mm deep with C.M. 1:3 (Crushed stone sand (M-sand) including curing, etc., complete as directed
Cement concrete 1:3:6 using Crushed stone sand (M-sand) and 12-20mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete
20mm thick sand faced cement plaster on wall upto hight 10 meters above ground level consisting of 12mm thick backing coat of CM 1:3 ( 1 cement : 3 sand ) and 8mm thick finishing coat of CM 1:1 ( 1 cement : 1 sand ) etc complete
Colour washing two coats over one coat of white washing
Supplying and fixing barbed wire fencing over the proposed compound wall with ‘L’ angle iron 50 x 50 x 6mm & 1.45m posts bent to shape at 2.5m centres with 6 rows of barbed wire and also in a zig zag manner at 25cm c.c. connecting all the rows with barbed wire will be of 2 ply and 12 gauge or other approved size including drilling hole in ‘L’ iron posts and fixing the posts in cement concrete 1:2:4 of size 15x15x45cm etc as directed.
Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations and basement
Disposal of surplus earth
Supplying and fabricating and erection of iron gate with of required size as per direction at site with G.I pipes of 50 mm and specials at all sides and 40x40x6mm angles as bracing on which 2 No.of m.s sheet of 16 gauge of size 2x2m each is welded as two halves fixing letter ''METROWATER' including one coat of primer with red lead etc.compete as directed.
Painting with two coats of ready mixed plastic emulsion paint first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt, etc., complete and including necessaary plaster of paris, putty, etc., wherever required.
Providing and fixing gardening items on site as directed.
Pile foundation
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete structural Bored Cast in Situ Piles witha minimum cement content of 400 kg/cu.m under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing fan clamps etc. as per standard specification and as directed by the Board officers complete.
Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works as follows: 10mm -32 mm dia rod (Fe-500 D Grade with CRS material)
Labour charges for only Boring and installation of 450mm dia RCC bored cast in situ piles depth measured from existing ground level including boring & socketing in hard stratas/ Rock inclulding tools,plants and all consumable Etc
Testing of piles : Intergrity test on all piles
Testing of piles : Static load test on working pile : Rs. 1000 per tonne
Bill No 24 Providing pumping machineries & allied works at the proposed 5 LL UGT at Ezhil Nagar 1st Main Road
Supply, delivery, erection, testing and commissioning of electrically driven, water lubricated horizontal split case water supply pumpset with bronze impellers, other accessories suitable for following duty point, including required capacity 3Ph, 415 V, AC, 50 Hz, TEFC, squirrel cage induction motor, on a common base plate, with suitable starter, fasteners including incidental civilworks etc. complete.
UNIT- 1 - 2760 lpm against a total head of 25 m
Supply, delivery, erection, testing and commissioning of vacuum pump of suitable capacity to prime the above pump, including required capacity 3 Ph, 415 V, AC, 50 Hz, Electrical Motor along with a common base plate for the pump and motor, coupling pulley, suitable starter, fasteners including incidental civil works and connecting with the suction pipe of the above pump sets including supply of necessary materials and labour etc.complete as instructed at site.
Vacuum Pump - 5 HP
Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete.
UNIT- 1 - 9 kVAR
Vacuum Pump - 2 kVAR
Supplying and fixing of 100 Amps Triple Pole fuse carrier in MS Sheet steel encloure with provision for accommodating the TNEB meter including earthing etc., complete.
Supplying and fixing of 100 Amps Triple Pole FSU with HRC fuses on suitable angle iron frame with earth connection only.
Capacity of M.V. Panel - 100 Amps
100 A FP Motorised Online Change over Switch 25 kA
63 A TP MCCB 25 kA for UNIT- 1
16 A TP MCCB 25 kA for Vacuum Pump
63 A TP MCCB 25kA (for UNIT- 1 cap.)
16 A TP MCCB 25kA (for Vacuum Pump cap.)
63 A TP MCCB 35kA (for PLC Panel)
32 A TPN MCB 10kA (for LDB)
Capacity of D.G. Set - 50 kVA
Supplying and clamping of variuos sizes of PVC insulated PVC sheathed armoured aluminium LT UG cable by MS clamps on wall or in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed.
From 100 Fuse Carriers to 100 Amps SFU & from there to 100 Amps MCCB Switch of MV panel (Wall)
size 3.5C, 50 Sqmm
From existing Control Panel of DG to 75A MCCB of MV Panel (Under ground)
size 3.5C, 35 Sqmm
From 63 A MCCB of MV Panel to Control Panel of UNIT- 1 (Wall)
size 3.5C, 25 Sqmm
From Control Panel of UNIT- 1 to motor (Wall)
size 3C, 25 Sqmm
From Starter in MV Panel to Vacuum Pump (Wall)
size 3C, 6 Sqmm
From 63 A MCCB of MV Panel to UNIT- 1 Capacitors (Wall)
size 3C, 10 Sqmm
From 16 A MCCB of MV Panel to Vacuum Pump Capacitor (Wall)
size 3C, 6 Sqmm
From 32A MCB of MV Panel to PLC Panel & LDB (Wall) size 4 core 10 sq.mm
From control Panel of Pump to Local P.B. Station & for automation size 3 core 2.5 sq.mm copper (Under ground)
From control Panel of Pump to Local P.B. Station size 3 core 2.5 sq.mm copper (Wall)
Supplying and fixing of cable gland and termination with Al. cable lugsfor the following sizes of PVC insulated PVC sheathed armoured alumunium LT UG cable and with earth connection.
size 3.5C, 50 Sqmm (EB)
size 3.5C, 35 Sqmm (DG)
Size 3.5C, 25 sq.mm (UNIT- 1)
Size 3C, 6 sq.mm (Vacuum Pump)
size 3C, 10 Sqmm (UNIT- 1 capacitor)
size 3C, 6 Sqmm (Vacuum Pump capacitor)
Size 4 core 10 sq.mm PLC Panel and LDB
size 3 core 2.5 sq.mm copper
Supply, delivery and fixing of dust and vermin proof Local Push Button station near the pumpset with 1 No"ON" and 1 No "OFF" push buttons (the "OFF" push button shall be locable in "OFF" position).
Supply, delivery and erection of Three Phase 6 way 32 Amps, 10kA LDB with the following: 1 No of 40 A FP isolator for incoming supply 3 Nos. of 16A, DP RCCB 3 Nos. of 16A, SP MCB 1 No of 16A, DP MCB 3 Nos of 6A, DP MCB in sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete.
Run of 2 of 2.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket.
Wiring with 2.5 sq mm PVC insulated single core copper cables of 650 V Grade on suitable rigid PVC pipe on wall and ceiling with PVC accessories, with MS switch box covered with 3 mm thick hylam sheet with continous earth wire connection of 14 SWG TC wire.
Light points
Fan Points
Wiring with 2.5 sq.mm PVC unsheathed single core copper cable on suitable rigid PVC pipe for 5A 3 pin CS plug non interlocking including supply and fixing of plug pin top in MS box with continuous earth connection by 14 SWG TC wire.
Lighting Fixtures
Supply and installation of 215 V - 1 x 40 W Flouresent TL fitting box type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.
Supply and installation of 215 V - 2 x 40 W Flouresent TL fitting industrial type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.
Supply and fixing of water tight bulk head fitting suitable for 100W bulb with lamp guard and lamp.
Supplying and fixing of 12" sweep AC exhaust fan complete including providing necessary opening in the wall.
Supply and fixing of 48" sweep AC ceiling fan complete with regulator with lm down rod (stem pipe) including supplying and fixing of fan clamp with side plates and cross arms.
a) Supply and erection of 1 No 3" dia 2 m long tubular Wall Mounted post with complete 250W sodium vapour lampwith necessary fitting and other accessories etc.
Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm
Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
Supplying and fixing of 15 amps, single phase, DP SFU switch with F&N on suitable TW Board with earth connection only
Supply and erection of 1 No 3" dia 5 m long tubular Pole Mounted post with complete 250W sodium vapour lampwith necessary fitting and other accessories etc.
Supplying and laying of PVC , LTUG cable under ground in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed for 2 core 4 sq.mm
Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm
Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
Supply and delivery of the following safety equipment a) 5 kg capacity ISI marked dry chemical powder type fire extinguisher
First Aid box ( medium)
Fire bucket - 3 Nos with MS stand
Rubber mat 6mmthick of 1.1 kv grade of size 2m x 1m
Fire safety rules chart
Shock treatment chart
"Caution / Danger" Board
Supply and delivery of the following tools:
Double ended open jaw spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 20x23 24x27, 25x28 & 30x32
Ring spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22 20x23 24x27, 25x28 & 30x32.
Screw driver of size 12 inches
Cutting plier of size 8 inches
Tong Tester ( clamp on type- multiutility) A C voltage 0 - 750 V AC current 0 - 1000 A D C voltage 0 - 1000 V Resistance 0 - 40 mega ohms
Electrical tester
Diesel Filling Pump (Hand operated )
Measuring Dip Rod (MS) (for measuring 200 ltr. standard Barrel )
Hack Saw frame with blade
Lever type Grease gun
Supply and delivery of Rechargeable emergency lamp with 600mm Fluorocuent lamp, dry type rechargable battery etc.,complete.
Earthing as per ISI specifications with necessary masonary work
Supply and connection of earthing conductor including two coats of approved painting and laying between earth pit and equipments
25 x 6 mm GI Flat
40 x 6 mm GI Flat
Supply, Delivery, erection, testing and commissioning of PLC Control Panel including the Remote Terminal Unit/ Programmable Logic Controller (RTU/PLC), Human Machine Interface (HMI), GPRS modem, 1 kVA UPS and accessories along with mounting assembly & cables including installing the PLC programming package and interconnecting with the existing SCADA System at Centralized Monitoring Location (the software will be provided by CMWSSB) as directed by Engineer and interconnecting with the ultrasonic level transmitters, electromagnetic flow meters and with existing MV panels, Capacitor panels at each sewage Pumping Station to switch ON/OFF the pumps based on level feedback, Switch ON/OFF the existing capacitor bank to maintain Powerfactor as per EB norms, and to monitor EB/ DG supply including incidental civil works etc., complete.
Supply, Delivery, erection, testing and commissioning of Ultrasonic Level Transmitter of range 0 - 15 meters in the UGT and OHT of the hed works with necessary mounting arrangements including incidental civil works etc complete.
Operation and maintenance of the installation: Operation and maintenanceof the plant with all auxiliary equipment for a period of 120 days after satisfactory supply, erection , commissioning and operating the entire plant for 30 days, free of cost by the contractor before handing over the plant to the Board.
Bill no.25 Supply,delivery, installation and testing of 200mm dia Electromagnetic flow meters for Inlet of Ezhil Nagar 1st Main Road 5 LL WDS
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast /Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished as per the details provided in the specificaion (Volume -II)
Specials for Electromagnetic FlowMeter
200 mm F/Spi Tail Piece
200 mm F/Soc Tail Piece
Jointing the DI Socket/spicot specials with rubber gasket(Tyton joint) including cost of jointing materials etc. complete.
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts including the cost of jointing materials etc. complete.
Cutting of DI Pipes true to axis and finishing the ends complete .
Bill no.26 Supply,delivery, installation and testing of 200mm dia Electromagnetic flow meters for Outlet Ezhil Nagar 1st Main Road 5 LL WDS
Supply, delivery, erection, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast /Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished as per the details provided in the specificaion (Volume -II)
Specials for Electromagnetic FlowMeter
200 mm F/Spi Tail Piece
200 mm F/Soc Tail Piece
Jointing the DI Socket/spicot specials with rubber gasket(Tyton joint) including cost of jointing materials etc. complete.
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts including the cost of jointing materials etc. complete.
Cutting of DI Pipes true to axis and finishing the ends complete .
Bill no.27 Providing Conveying of 200mm dia DI
Supply, delivery, laying and jointing D.I. Pipes of the following sizes of socket @ spigot end, push - on - joint DI pipes of classification K9 conforming to IS: 8329/2000 in standard lengths with cement mortar lining inside and outside Zinc coating, including rubber gaskets, including Labour charges for loading, unloading and stacking at the site etc., including earthwork excavation for trenches in hard stiff clay, black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10m and initial lift of 2m conveying to the site of work, lowering into the trenches, and aligning, jointing, refilling the trenches with excavated soil, watering and ramming to consolidation, disposal of surplus earth etc., complete for the pipes of following diametres at the following depths.
200mm dia DI K9 pipe at 1.25m depth
Supply, delivery, conveying and fixing following sizes of DI specials of DI push - on joint specials as mentioned below conforming to IS: 9523/2000 including loading, unloading and stacking at the site etc as directed by the engineer at site, and including earthwork excavation, refilling with excavated soil, watering and ramming to consolidation and disposal of surplus earth etc complete.
Specials along conveying main alignment
200mm D/Soc DI 90o Bend
200mm D/Soc DI 45o Bend
200mm D/Soc DI 22.5o Bend
200mm MJ Collar
Supply, delivery, conveying and fixing following sizes of DI specials of DI push - on joint specials as mentioned below conforming to IS: 9523/2000 including loading, unloading and stacking at the site etc as directed by the engineer at site, and including earthwork excavation, refilling with excavated soil, watering and ramming to consolidation and disposal of surplus earth etc complete, for inlet connection to UGT
200mm F/Soc Tail piece
200mm DI/Fl 90 deg duckfoot bend
200mm DI D/Fl pipe 2m length
200mm DI D/Fl 90 deg bend
200mm DI D/Fl pipe 0.5m length
200mm DI D/Fl pipe bell mouth
Supplying, delivery, conveying and fixing the CI sluice valves as per IS 14846/2000 PN 1 with IS :14846/2000 including Flange/socket and Flange Flange/spigot tail pieces etc., loading, unloading , Transportation charges and stacking etc complete as per specifications.
200mm sluive valve with tail piece
200mm x 250mm D/S taper
200mm DI cut pipe 1m long
200mm MJ collars
Supplying and delivery at site, conveying and fixing of CI double air valves and specials of following sizes including loading, unloading, Transportation charges and stacking etc as directed by the engineer at site etc., complete as per specifications.
200x200x80mm S/S/F Tee
80mm air valve
80mm S.V for fixing A.V
Cutting of DI pipes true to axis and finishing the ends complete
Jointing the DI Socket/spigot pipes and specials with rubber gasket(Tyton joint) including cost of jointing materials etc.,complete
For specials
Jointing the DI double flanged pipes and specials with rubber insertion to the required specification with M.S bolts and nuts and testing the pipes to the required pressure with water including cost of jointing materials etc., complete
Testing of DI pipes with hydraulically testing equipment by filling with water ( including cost of water) and testing to recommend pressure in convenient stretches and extending the bursts if any occured during the test, excluding the cost of pipes, including other incidental and operational charges etc. complete for following diameter of pipes.
Construction of Air Valve Chamber in second class brick work in CM 1:4 proportion with 12 mm thick outside plastering and 20mm thick inside plastering in CM 1:3 proportion, RCC cover slab in CC 1:2:4 proportion using 20 mm jelly, chamber foundation and bed block in PCC 1:3:6 proportion using 40 mm jelly including cost of reinforcement and labour charges, CI steps, etc. as per drawing including providing and fixing L.S. cover and frame of size 60cm x 60cm including necessary masonry work and plastering etc., complete as per specification and as per drawing
1.2mx0.9mx1.8m size chamber for 80mm dia Air valve
Construction of Sluice Valve Chamber of following sizes in second class brick work in CM 1:4 proportion with 12 mm thick outside plastering and 20mm thick inside plastering in CM 1:3 proportion, RCC cover slab in CC 1:2:4 proportion using 20 mm jelly,chamber foundation and bed block in PCC 1:3:6 proportion using 40 mm jelly including cost of reinforcement and labour charges, CI steps, etc. as per drawing including providing and fixing L.S. cover and frame of size 60cm x 60cm including necessary masonry work and plastering etc., complete.
1.35x1.35x1.95 m valve chamber for 200mm dia Sluice valve
Disposal of Surplus earth upto a lead of 5Km as directed by the Engineer in charge
200mm dia
Cutting Asphaltic concrete road
Bus Route
Non Bus Route
Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing "METRO WATER" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites.
Providing thrust blocks with Plain Cement Concrete in 1:3:6 with 40mm HBG including fixing of M.S rod for anchorage as directed during execution with necessary earth work excavation including the cost of shuttering, compaction, curing etc. complete.
200mm DI D/S 90o Bend
200mm DI D/S 45o Bend
Hire charges for diesel pump sets of 7.5 HP including cost of fuel and machinist for running the machine per hour of running 3 nos Diesel Engine X 90 Hrs
Interconnection works with 500mm dia DI pipe
Excavation in hard stiff clay , stiff black cotton, hard red earth, shales,muram, gravel stoney earth and earth mixed with small size boulders as per SS 20 B with intial lead of 10m and lift of 2m.
Supply, delivery, conveying and fixing following sizes of DI specials of DI push - on joint specials as mentioned below conforming to IS: 9523/2000 including loading, unloading and stacking at the site etc as directed by the engineer at site, and including earthwork excavation, refilling with excavated soil, watering and ramming to consolidation and disposal of surplus earth etc complete.
200mm F/Soc Tail piece
200mm MJ Collar
500x200 mm Tee
Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations and basement.
Disposal of Surplus earth (pipe portion)
Bailing out water using diesel pumpset 5HP
The Contractor must obtain the existing Static GCP points from CMWSSB which should be considered as the control point with known coordinates X, Y and Z. The static GCP must be established from this PBM using triangulation network method and Frog & leap method for linear areas. The contractor must strictly avoid radial offset method. If the PBM is not available with CMWSSB within the area of interest, the contractor must procure the nearby Survey Of India, GTS benchmark available to establish the static GCP of the project location using the above mentioned methods only.
As built survey for every sewage and water pipeline and other assets must be done using DGPS based RTK method by transferring the coordinates from the nearest Static GCP of CMWSSB. Where there are signal interruptions for the RTK method, Total Station can be used. The coordinates from the static GCP shall be transferred to the Total Station by RTK method and the co- ordinates of the assets can then be captured by Total Station. All the features, attributes of all the assets, utilities captured shall be Geo referenced as per standard Coordinate reference system (WGS 84 UTM Zone 44N). The final base map with assets and utilities shall be furnished in (.shp) format. The geo referenced assets and utilities along with the attributes (as specified by the GIS Wing, CMWSSB) shall be converted into proper geo database (FGDB / PGDB) with the attributes. One set Hard and Soft Copy of all the CMWSSB assets and utility has to be prepared category wise network wise in A0 Print for verification in a print scale of 1:1000 in A0 plot, with standard legends in international and NUIS standards and should be legible and three sets of final Hard Copy in A0 print.
For the Underground / Surface Assets along the roads for the distance ranging from: <2 Km
For the Point Underground / Surface Assets along the roads
Bill no.28 Road cut restoration charges
Providing Wet mix macadam including premixing the material with water at OMC in mechanical mix plant carriage and laying in uniform layers and compacting etc.Complete as per clause 406 of MORT&H specifications
Providing and laying in position machine batched, machinemixedandmachinevibrateddesignmixcement concrete of M30 grade for reinforced cement concrete structural elements under controlledwater cement ratio withplasticiser using20mmanddowngradedmachine brokengranitestone jellyexcluding thecost of centering and shuttering and reinforcement but including curing, fixing, fanclampsetc., asper standardspecificationand as directed by the Board officers complete
Total excluding GST
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
upload.rar
Tender Documents • 4.24 MB
BOQ_759254.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid