The Executive Engineer Electrical HEED
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
GENERAL-THANGASSERY FISHING HARBOUR-Upgradation and Capital repairs of electrical installations-General Electrical Work
2025_HED_822333_1
HED/CEHED/TR/247/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
THANGASSERY FISHING HARBOUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
5 Jan 2026
17 Dec 2025
29 Dec 2025
17 Dec 2025
27 Dec 2025
17 Dec 2025
Work Name:GENERAL-THANGASSERY FISHING HARBOUR-Upgradation and Capital repairs of electrical installations-General Electrical Work
uitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole<OD145/2025-2026:Supplying and fixing surface /recess mounting 1 row 18 modules distribution board with Double door , dust and water proof IP 66 Hensel make KV 9118M opaque or equivalent , DB of poly carbonate inclusive of, common neutral link, earth bar, din bar for mounting MCB with provision for RCCB as incomer. 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps±2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wi
made out of 25x5 mm MS flat and anchor bolts, filling the space between slab and pole using PCC 1:11/2:3 (M20) , constructing muffing of size 30 cmx30cmx30cm in M20 mix. The top of the pole must be closed with Table E MS flange and dummy flange, bolted with stainless steel nut and bolts and it must have an inverted Y arrangement using 25mm GI medium pipe 10cm long welded to the pole 10 cm below the top flange to take outgoing wire. The tubular post shall be painted with two coats of epoxy primer and epoxy paint of approved make and colour.nOD6485/2025-2026:Supply and fixing 2 m long tubular pole made out of 50 mm dia (Class B) GI pipe with ISI mark on GI roof truss by using flange, clamping the pipe to the GI truss using MS clamps made out of 25x5 mm MS flat and nut & bolts. The top of the pole must be closed with MS flange and dummy flange, bolted with stainless steel nut and bolts and it must have an inverted Y arrangement using 25mm GI medium pipe 10 cm long welded to the pole 10 cm below the top flange to take outgoing wire. The tubular post shall be painted with two coats of epoxy primer and epoxy paint of approved make and colour¬OD6454/2025-2026:KSEB Documentation charge for getting new connection connected work including preparation of drawing ,file work submitting application etc complete as req job CIVIL WORKç15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.60 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd.pdf
Tender Documents • 1.67 MB
BOQ_1378211.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .