Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Lowest One | |
| 2 | L2₹42.8 L+₹8.3 L (24.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.6 L+₹10.0 L (29.1%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | Not Admitted-Fee/PreQual/Technical V P O JAWALAMUKHI TEHSIL JAWALAMUKHI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 176001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹33.3 L
EMD Value
₹57,500
Closing Date
10 Aug 2020, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Jal Shakti Division Mandi
Jal Shakti Division Tarna Hill Mandi HP
Construction of Basement and Design of framed structure complete building
2020_HPIPH_39499_1
5394-5443
Open Tender
Civil Works
Item Rate
120 days
Dhangsidhar Mandi
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
Yes
EE Mandi
₹57,500
Yes
23 Dec 2020
3 Aug 2020
10 Aug 2020
3 Aug 2020
10 Aug 2020
3 Aug 2020
120 days
Amount
Excavation in foundation and trenches in earth work upto all depth in all kinds of soil such as pick work jumper work,blasting work,chiselling of soft /hard rock where blasting is prohibited in all leads and lifts and including trimming of sides levelling of bed to correct grade stacking the excavated soil in 15cm. layers when required into plinth sides of foundation including consolidating each deposited layer by ramming and watering and then disposing oof all surplus excavated soil as directed in all leads and lifts and soring/strutting timbering and dewatering where ever required to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size ) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts.
Random Rubble Masonry / polygonal rubble masonry (uncoursed / brought to courses) with hard stone of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20 mm nominal size) at plinth level in cement mortor 1:6 ( 1 cement : 6 sand) with in all leads and lifts.
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu- reinforcement concrete and plain concrete work in:-
Foundation footing bases of columns etc and mass concrete.
Columns, pillars, post and struts.
Square, rectangular or polygonal in plan.
Beam, cantilever, girders and lintels.
Sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. in depth in all heights from floor.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like.
Floors etc. up to 200 mm in thickness.
Edges of slab and breaks in floors and walls under 20 cm wide.
Stair cases with sloping or stepped soffits excluding landings.
Providing & Laying cement concrete work 1:11/2: 3 (1 cement : 11/2 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Foundation footing bases of columns etc and mass concrete.
Colunms pillars posts and struts upto floor two level.
Lintels, beams girders bressumers and cantilevers upto floor two level.
Providing and laying cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement in:-
Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level.
Stair cases (Except spiral stair cases) excluding landing but including preparing of the surface and finishing of nosing upto floor two level.
Providing mild steel / Tor steel reinforcement for RCC work including bending binding and placing in position complete upto floor two level. Tor Steel
Provdiing and laying 20 cm thick composit stone masonry with stone masonry with stone facing of chisel dressed stone one line dressed in cement mortar 1:6 (1 cement :snnd) and concrete backing with cement concrete 1:3:6 (1cement :3and :6 graded stone aggregate 20 mm norinal size) on inner face of walls including cenrting shuttering and propping complte upto floor two level.
Brick work using common burunt clay building bricks in super structure above plinth level upto floor two level in cement mortor 1:6 (1 cement : 6 sand) (Ist class brick)
Half bricks masonry in common burnt clay building bricks in cement mortar 1:4 (1cement : 4 sand) (Ist class brick)
Providing and Fixing anodized powder coated aluminium work for doors, windows, ventilators and partions with extruded built up standerd tublar and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade acccording to IS -1868 (minimum anodic coating of grade AC (15) fixed with raw plugs and screws or Fixing with clips or with expension hold fasteners I/C necessary filling up of gaps at junction at top bottom nd sides with required PVC neroprene etc. aluminium section shall be smooth, rust free, straight mitered and jointed machenically where ever required including cleat angle aluminium snap beading for glazing, pannelling CP brass stainless screws, long bolts 10 mm dia on top and bottom tail of doors, complete for door frmes pannellled and glazed, wire gauge shutters etc. as per architectural drawings in all leads and lifts.
6mm cement plaster to ceiling in CM 1:3 ( 1 Cement : 3 Sand)
15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:5 (1 cement: 5 sand)
20 mm thick cement plaster in single coat on rough side of brick/stone/concrete walls for interior plastering up to floor two level including arrisses, internal rounded angles, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with in all leads and lifts in C.M 1:5 ( 1 cement : 5 sand )
Stone soling under floor with in all leads and lifts.
Providing and laying cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth.
Kota stone slab flooring 20 mm (average) thick base of cement mortar 1:4 ( 1 cement : 4 sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.30 mm thick.
Kota stone slab 25 mm thick in riser of steps, skirting dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 sand ) and jointed with gray cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete .30 mm thick.
Providing and laying granite stone in flooring 20mm (average) thickness base of cement mortor 1:3 (1cement : 3sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of granite stone including rubbing and polishing complete. 20 mm thick.
Coloured glazed tiles 6 mm thick (300x450 mm) in skirting risers of steps and dedo12 mm thick cement mortar 1:3 (1 cement : 3 sand) and jointed with cement slurry in all leads and lifts.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size.
Proving under layer for plinth protection of 75 mm thick (unconsolidated) bed dry brick/stoneAggregated 40 mm nominal size will rammed with rammed and consolidated and grouted with fine sand including preparation of ground.
Constructing course rubble hammer dessed "U" shape open surface drain with side wall 15x22 cm in cement mortor 1:6 (1cement : 6 sand) and inside plastering with cement plaster 1:3 (1cement : 3 sand) including earth work and laayng 10 cm cement concrete in 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40 mm nonminal size) and 7.5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete .
Applying one coat of Acrylic primer (Spectrum or equivalent of Superior quality) on new concrete/masonry/plastred surfaces after and including preparing the surface by thoroughly brushing the surface free from mortar droppings and other foreign matters, sand papering the surface smooth complete.
Finishing wall with weather proof exterior grade emulsion of approved design (Apexultima) or its equivalent on undecorated wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter etc. including sand paper smooth complete.
Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete / stone / plastered wall surfaces to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth including applying of putty a required for metling the surface.
Painting two coats (excluding priming coat) over new steel and other metal surfaces with enamel paint to give an even shade including cleaningthe surface of dirt, dust and other foreign matters sand papering and stopping with enamel paint other than white.
Providing and Fixing 75 mm x 60 mm rounded hand rails in straight length complete in 1st class indian teak wood.
Providing and Fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rails of T- iron 40x40x6 mm with 38 mm dia steel pulley complete with bolts & nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint.
ELECTRICAL WIRING :-
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group "C"
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying & Fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-
4 modules (140mmx78mmx50mm)
6 modules (205mmx78mmx50mm)
8 modules (120mmx135mmx60mm)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2 x 1.50 Sq. mm.
2 x 2.50 Sq. mm.
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 15/ 16 Amps one way Modular switch.
6 pin,15/16 Amps Modular socket outlet.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
TV. Socket outlet, modular.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
Telephone socket outlet, Modular.
Supplying and Fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
Supplying and Fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-12 way
Supplying and Fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
Supplying and Fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 450 mm & cross-sectional area (25.4 mm x 4.75 mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530 mm x 450 mm x 150 mm) nominal with all accessories including connections, earthing the body etc. as required.
Providing and Fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required.
100 Amp. Category-A
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required.
Single pole & neutral. Cat-B.
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required.
Supplying and Fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-B.
Supplying and Fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and Fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and Fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required.
25 Liter capacity water heater (Cat-A)
10 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and Fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.
Exhaust Fan, Light duty, (Domestic) 225 mm sweep
Providing and Fixing of Syska make LED Tube Fixture 18 watt complete in all respect in all leads and lifts.
Supplying and Fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
Supplying and Fixing bakelite batten/angle holder including connections etc. as required.
Supplying and Fixing of integral CFL Post Top Lantern of following capacity, cast aluminium spigot, spun aluminium canopy, opal acrylic diffuser, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required.
Gate post top lantern - CFL 26 watt.
Spplying and Fixing of split type air conditioner Blue Star / LG / Onida Whirlpool / Lioyd / Samsung make having two stars features auto clean filter four way swing all copper pipes including making provision of draining of back moisture water tharough GI pipe 20 mm dia electronic voltage stabilizer, cutting holes for conduits in wall, unit bracket set fixed on outer wall complete as required. 1.50 Tonne capacity.
Providing and Fixing of Water Cooler makes of reputed make i.e. USHA/ Voltas / Blue Star etc. having capacity of 40 liters in all leads and lifts
WATER SUPPLY AND SANITARY FITTINGS :-
Providing and Fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including Fixing with approved adhesive etc. complete.
75 mm dia
110 mm dia
Providing and Fixing PVC plain bend ISI marked including Fixing with approved etc. complete.
75 mm dia
110 mm dia
Providing and Fixing PVC door bend with oval access door, insertion rubber washer 3 mm thick bolts and nuts ISI marked complete including Fixing with approved etc. complete.
75 mm dia
110 mm dia
Providing and Fixing PVC collars ISI marked including Fixing with approved etc. complete.
75 mm dia
110 mm dia
Providing and Fixing PVC singal equal branch plain ISI marked including Fixing with approved etc. complete.
75 mm dia
110 mm dia
Providing and Fixing PVC single equal branch with oval access door, ISI marked insertion rubber washer 3 mm thick bolts and nuts complete including Fixing with approved etc. complete.
75 mm dia
110 mm dia
Providing and Fixing PVC floor trap ISI marked of self cleaning design including Fixing with approved, cost of cutting and making good the wall and floors etc. complete.
110 mm x 90 mm.
Providing and Fixing vitreous China wash, down water closet (EuropeanType WC pan) with integral "P" or "S" trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 3 sand) ( seat and cover to be measured and paid for seperately) : Anglo Indian (Universal Closet)
Providing and Fixing white solid type plastic sheet and cover for wash down water closet with CP brass hinges and rubber buffers.
Providing and Fixing 10.00 liters Concealed cistern with a pair of C.I. or mild steel brackets, complete with fitting such as lead valve less syphon, 15 mm nominal size brass ball valve with polythene float, C.P. Brass handle, Unions and couplings for connections with inlet, outlet and couplings for connections with inlet, outlet and over flow pipes, 40 mm dia C.P. flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for separately) in all leads and lifts.
Providing & Fixing viterious china wash basin with single hole for pillar tap with C.I. or M.S. bracket painted white including cutting hole including good the same excluding fitting Cera sanitary work (cornet) white Flat back 630 mm x 450 mm.
Providing and Fixing viterious china padestral for wash basin complete recessed at the basic for reception of pipe and fittings Cera sanitary work (carnet) white (Viterious China in White Colour)
Providing and Fixing M.I. Union for wash basin or sink 32 mm dia.
Providing and Fixing C.P. brass waste and plug for glazed ware sinks, basins etc. with long screwed shank and fly nut and fixed to steel pipe including vulcanite plug, brass chain and stud 32 mm nominal bore.
Providing and Fixing 600 mm x 450 mm bevelled edge mirror of superior glass marked on 6mm thick AC sheet or plywood sheet and fixed to wooden plug with CP brass screws and washer.
Providing and Fixing CP Brass towel rail complete with CP Brass brackets fixed to wooden plug with CP Brass screws 600 mm x 20 mm.
Providing and Fixing 600 mm x 120 mm glass shelf with C.P. Brass bracket and guard rail complete, fixed to wooden plugs with C.P. Brass screws.
Providing and Fixing chromium plated brass soap dish with C.P. Brass brackets fixed to wooden cleats with C.P. brass screws.
Providing and Fixing Tooth brush and Tumbler holder (Viterious China)
Providing and Fixing C.P. Brass Shower Rose with 15 mm to 20 mm inlet 100 mm dia.
Providing and Fixing brass bib tap (Superior or heavy type) 15 mm dia long nose.
Providing and Fixing brass bib tap (Superior or heavy type) 15 mm dia short body.
Providing and Fixing C.P. brass angle valve 15 mm without Nuts and pipe.
Providing and Fixing Brass Divertor 15 mm of superior quality in all leads and lifts.
Providing and Fixing Kitchen Sink mixture of superior quality complete in all respect in all leads and lifts.
Providing and Fixing wash basin mixture of superior quality complete in all respect in all leads and lifts.
Providing and Fixing P.V.C. connection with brass unions 300 / 450 mm length 15 mm nominal bore.
Providing and Fixing 100 mm dia chromium plated grating of superior quality for floor, gully or Nahni trap.
Providing and Fixing PTMT Jet spray of approved quality and colour with one meter tube.
Providing and Fixing of C.P. Towel ring of superior quality.
Providing and Fixing of C.P. towel rack 600 mm x 250 mm of superior quality.
Providing and Fixing stainless steel kitchen sink (Double Bowl) of approved standard ISI make with drain board and C.P. waste with C.I. or M. S. brackets painted white including cutting holes and making good the same but excluding fitting 610 x 460 mm with bowl depth 200 mm.
Providing and Fixing to wall ceiling and floor galvenised mild steel tubes (light grade) tube fittings and clamps including making good the wall, ceiling and floor in all leads and lifts.
25 mm nominal bore
Providing and Fixing brass full way valve with wheel of 25 mm dia (Heavy Duty) complete in all respect in all leads and lifts.
Providing and Fixing to wall ceiling and floor KITEC Composite PR Pipes (as per IS 15450:2004) (The pipes are having inner layer in natural colour & outer layer in black colour) and clamps including making good the wall, ceiling and floor complete in all respect in all leads and lifts.
15 mm nominal bore
20 mm nominal bore
Providing and Fixing KITEC Coupler composite crimp fittings-internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
15 mm dia
20 mm dia
Providing and Fixing KITEC Elbow composite crimp fittings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
15 mm dia
20 mm dia
Providing and Fixing KITEC Equal Tee Pcomposite crimp fiitings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
15 mm dia
20 mm dia
Providing and Fixing KITEC Reducing Tee composite crimp fittings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
20x15 mm dia
Providing and Fixing KITEC Reducer composite crimp fittings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
20x15 mm dia
Providing and Fixing KITEC female threaded connector composite crimp fittings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
15 mm dia
20 mm dia
Providing and Fixing KITEC Male threaded connector composite crimp fittings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
15 mm dia
20 mm dia
Providing and Fixing KITEC Female Elbow composite crimp fittings internal sealing of size mentioned below (Heavy Duty) complete in all respect in all leads and lifts.
15 mm dia
20 mm dia
Providing and fixing KITEC pipe Holding Clamps with brass plate of approved design with steel screws and rawal plugs etc. complete.
Providing and Fixing of PVC water storage tank sintex having of capacity 1000 liters with necessary fittings including over flow pipes, scour pipes etc. inlet and outlet and inside paint of required size for inlet or outlet and inside paint of approved quality complete including hoisting complete in all respects.
Construction of manhole with RCC top slab in 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 (1cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) in side plastering 15 mm thick with cement mortar 1:3 (1cement:3 sand) finished with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1cement:2 sand:4 graded stone aggregate 20 mm nominal size) including curing complete.
i) In side size 800 mm x 800 mm x 500 mm deep excluding CI cover with frame (light duty single seal pattern - 1) 455 mm x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (Weight of cover 23 kg and weight of frame 15 kg)
With 200 mm thick walls of brick masonry using common burunt clay building bricks in cement mortor 1:3 (1cement : 3 sand)
Providing and Fixing stoneware gully trap grade "A" complete with C.I. grating, brick masonry chamber in cement mortor 1:5 and water tight C.I. cover with frame of 300 mm x 300 mm size (inside) the weight of cover to be not less than 4.53 kg and frame to be not less than 2.72 kg. (Sqaure Mouth traps 100 mm x 100 mm size P type)
Provision for structural Drawings and Design of building from Basement to second Floor of all components and foundation plan including steel roofing as per architectural drawing supplied by the department.
RAKESH GOEL
Jagdish Kumar, Govt. Contr
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .