Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC 131 SITANATH BOSE LANE BLOCK B GR FLR SALKIA HOWRAH WEST BENGAL 711106 | HOWRAH | HOWRAH | WEST BENGAL | 711106 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.3 L+₹1.4 L (20.5%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹9 L+₹2.1 L (30.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L3₹9 L+₹2.1 L (30.7%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹9.4 L
EMD Value
₹18,900
Closing Date
24 Sept 2021, 5:00 pmClosed
Managing Director WBEIDC Ltd
Webel Bhavan Salt Lake SEC V EP GP Block KOL 91
Selection of agency for supply and installation of Digital UV printed designer false ceiling for the Webel Tower I project at plot no BN 4 Sec V Salt Lake Kol 91
2021_WEBEL_343550_1
07/Webel/IDM/21-22/26
Open Tender
IT WORKS ORG
Item Rate
30 days
BN4 IT Park Salt Lake SEC V Kolkata
Please refer to the tender documents
5 documents required · 5 mandatory
₹500
₹18,900
21 Dec 2021
13 Sept 2021
25 Sept 2021
13 Sept 2021
24 Sept 2021
13 Sept 2021
Amount
Supplying, fitting, fixing, installation complete work in all respect including required scaffolding, etc. Mineral Fibre Acoustical Suspended Ceiling System to be fixed at the atruim portion of height about 7.8 meters with 19 mm thick Ultima Create Microlook 90 Edge Tiles ULTIMA CREATE RH99 ML90 15 600X600X19MM WITH DOUBLE COAT UV PRINT OF CUSTOM IMAGE OF World Map or equivalent design as approved by the Engineer-In-Charge with Silhouette 15mm face exposed grid.
The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTM E-1477, Thermal Conductivity k = 0.045 - 0.048 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTM E 84 with 19mm Square Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable, soil and scratch resistant and having superior scrub-ability (Gardner Test). The tiles shall be classified as ISO 14644-1 cleanroom class 5. The tile shall have a rating of 8 or above for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 36%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product.
SUSPENSION: The tile shall be laid on Silhouette 38 profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour with mitred ends & “bird’s mouth” notches to provide mitred cruciform junctions colour global white (Matching to tile color).Grid shall have double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 7.9 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 9.5 kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull-out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of 0T bending capability.
INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per recommended procedure.
SUSPENSION SYSTEM accessories supplied by consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).
S S ENGG. ENTERPRISE
PRESCIENCE TECHNO INDUSTRIES
ALUSTEEL INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .