Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC 676301 | MALAPPURAM | KERALA | 676301 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.8 L+₹12,044 (7.04%)Rejected-AOC EDAYUR PO VALANCHERY MALAPPURAM | MALAPPURAM | KERALA | 676552 | L2 | Rejected-AOC L2 |
Tender Value
₹1.7 L
EMD Value
₹4,358
Closing Date
12 Jul 2023, 1:00 pmClosed
OFFICEOFASSISTANTENGINEERLIDEWKUTTIPPURAM
OFFICEOFASSISTANTENGINEERLIDEWKUTTIPPURAM
Annual PlanElectrification of Ponnakkaran colony WSS Proj NoS021823Kuttippuram grama panchayathGeneral Electrical Work
2023_LSGD_585395_1
22/2023-24/AE/LID EW/KTPM
Open Tender
Electrical Works
Item Rate
75 days
OFFICEOFASSISTANTENGINEERLIDEWKUTTIPPURAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹4,358
Yes
26 Sept 2023
3 Jul 2023
13 Jul 2023
3 Jul 2023
12 Jul 2023
3 Jul 2023
Amount
Project no: SO 218/23
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD48915/2023-2024:Supply and fixing DOL starter suitable for 7.5 HP 3 phase motor
OD48942/2023-2024:Supply and providing 3KVAR metalised poly propeline capacitor standard duty 440 v box type and giving connection
OD49257/2023-2024:Supply and fixing 3 phase ammeter accuracy class 1 on existing board and giving connection
OD49258/2023-2024:Supply and fixing 3 phase volt meter accuracy class 1 on existing board and giving connection
OD49265/2023-2024:Supply and fixing 32A TPN SDF with sheet steel enclosure and HRC fuses on existing board and giving connection as required
OD49262/2023-2024:Supply and fixing 6/10 A DPMCB on existing board and giving connection as required
OD49263/2023-2024:Supply and fixing phase indication lamp (led) blue on existing board and giving connection
OD49264/2023-2024:Supply and fixing phase indication lamp (led) red/yellow on existing board and giving connection
OD49266/2023-2024:Supply and fixing 40A rating 4pole 100 ma RCCB on existing board and giving connection
OD49270/2023-2024:Supply and fixing TPMCB sheet steel enclosure on surface and giving connection as required
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD49276/2023-2024:Supply and installation of 9w LED Bulb 240V AC
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
OD53084/2023-2024:, supply and installation testing and commissioning of new 7. 5HP borewell submersible motor pumpset suitable for 150mm borewell with 7.5HP,3phase,50Hz,380/415V, 84/205/300 MT head, 7200/5400/3000 liter/hour discharge RF15/54D TEXMO or equivalent make of CRI/DECCAN/KIRLOSKER /V GUARD delivery size of 40mm or nearest using chain pully block/tripole and leackproof materials as required and suspended on existing rope including fixing GI/column pipe as delivery pipe ,lowering upto bottom of well at required water level with necessary supports at both ends of motorpumpset ,giving all electrical connections and conducting trial run at full load satisfactorily
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD56624/2023-2024:Supply and providing HD Collar 40/50mm
OD57178/2023-2024:Supply and laying good quality 50mm HD PE pipe(ISI marked) with specials and giving connection using lrack proof materials as required
OD57186/2023-2024:Supply and providing pvc socket ( FTA) 50mm
OD57217/2023-2024:Supply and providing pvc reducer 63/ 50mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD57225/2023-2024:Supply and fixing 2*25*5 mmGI strip test joint for earthing
OD57226/2023-2024:Supply and fixing25mm*3mm GI Strip earth lead from test joint to earth plate
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD57568/2023-2024:Supply and providing superior quality brass bolt with hexagonal/square head ,nut and washers for the following size etc as required 25*6 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
OD57641/2023-2024:Charges for preparation of KSEB Test report for submitting to the concerned KSEB Section office
OD57645/2023-2024:Supply and fixing dust and vermin proof 3phase syntex meter board GSMB 4537 as required
OD57688/2023-2024:Supply and providing32A HRC fuse link with base and giving connection in the existing meter board
OD57687/2023-2024:Supply and providing 32A neutral link mounted on DMC/SMC base and giving connection in the existing meter board
OD57686/2023-2024:Supply and providing 50mm brass non return valve as required
OD57685/2023-2024:Supply and fixing Dry run cum single phasing preventor suitable for 3 phase 400V 7.5HP Motor on surface and giving connection as required
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD58345/2023-2024:Supply and providing polymer braided twisted cord twin rope string (12mm) for hanging motor pump set
MOIDEENKUTTY KOLAMBAN
Bidder Name
AK ELECTRICALS
MOIDEENKUTTY KOLAMBAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_865067.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .