Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAdmitted-Fee/PreQual/Technical/Finance | ₹5.1 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹5.3 L+₹24,223 (4.79%)Admitted-Fee/PreQual/Technical/Finance | ₹5.3 L+₹24,223 (4.79%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹5.3 L+₹27,008 (5.35%)Admitted-Fee/PreQual/Technical/Finance | ₹5.3 L+₹27,008 (5.35%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹5.4 L+₹36,113 (7.15%)Admitted-Fee/PreQual/Technical/Finance | ₹5.4 L+₹36,113 (7.15%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹5.5 L+₹48,598 (9.62%)Admitted-Fee/PreQual/Technical/Finance | ₹5.5 L+₹48,598 (9.62%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | A.D.PRAKASH ENTERPRISES L5 | RAJ CONTRACTOR L4 | V BEST ENGINEERS L1 | G KUMAR L2 | ABI BUILDERS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of pre-wired LED street light with pressure die cast housing and secondary lens delivering lumen level not less than 3600lumens and not more than 30W power, IP66 protection and 4kV inbuilt surge protection, THD<10%, PF>=0.95, 5700K pure white, conforms to IS 10322 Part 5 complete, including necessary interconnections and Earthing as required. (Approved makes: Bajaj/Philips/Havells/Crompton) | ||||||||
| 1.01 | On Octagonal Pole | 22 | Each | 11,784.25 ₹2,59,253.5 | 7,000 ₹1,54,000 | 1,430 ₹31,460 Lowest | 4,500 ₹99,000 | 3,200 ₹70,400 |
| 2.00Supply and installation of a 3-meter-high Hot Dip Galvanized (HDG) octagonal pole made out of 3 mm thick hot rolled steel sheet having 130 mm bottom A/F and 70 mm top A/F, provided complete with a base plate of size 200 mm × 200 mm × 16 mm thick. The pole shall be erected on RCC foundation of mix 1:1.5:3 (1 cement : 1.5 coarse sand Zone-III : 3 graded stone aggregate of 20 mm nominal size) including necessary foundation bolts, excavation, cantering, shuttering, strutting, propping, placing in position and curing etc. complete. The work includes providing and placing Thermo-Mechanically Treated (TMT) reinforcement bars of grade Fe-500D or higher, including straightening, cutting, bending, binding and placing in position for RCC work up to plinth level, as per the pole manufacturer’s recommendations. The item shall also include: 1. Excavation and refilling of foundation pit 2. Finishing of foundation 3. Providing and fixing 6A DP MCB inside suitable enclosure 4. Providing 3 Core × 1.5 sq.mm flexible PVC insulated copper cable for interconnection between luminaire and MCB 5. GI sheet for cable gland mounting 6. Proper earthing arrangement 7. Two coats of epoxy primer and epoxy paint (Aluminium grey) All necessary civil and electrical accessories to complete the work in all respects as per pole manufacturer’s recommendation and as directed by Engineer-in-Charge. (Approved makes: Bajaj/RR Ispat/Crompton; MCB: Legrand/L&T; Cable: Polycab/RR Kabel/Finolex/Havells) | ||||||||
| 2.01 | With 0.5mtr long hot dip galvanized standard type Single armbracket made up of 40NB dia GI pipe suitable to mount on a pole having a top 70mm A/F. (Approved makes: Bajaj/RR Ispat/Crompton) | 16 | Each | 2,757.69 ₹44,123.04 Lowest | 3,200 ₹51,200 | 15,125 ₹2,42,000 | 13,500 ₹2,16,000 | 15,600 ₹2,49,600 |
| 2.02 | With 1mtr long hot dip galvanized standard type Double armbracket made up of 40NB dia GI pipe suitable to mount on a pole having a top 70mm A/F. (Approved makes: Bajaj/RR Ispat/Crompton) | 3 | Each | 2,900 ₹8,700 Lowest | 5,500 ₹16,500 | 15,950 ₹47,850 | 13,500 ₹40,500 | 16,800 ₹50,400 |
| 3.00Supply of FRLS XLPE power cable of 1.1 kV grade of the following sizes as required. (Approved makes: Polycab/RR Kabel/Finolex/Havells) | ||||||||
| 3.01 | 3C x 4 sqmm Aluminum armored cable | 337 | Mtrs | 220.65 ₹74,359.05 | 310 ₹1,04,470 | 170 ₹57,290 | 135 ₹45,495 | 130 ₹43,810 Lowest |
| 4.00Supplying and laying of the following size DWC HDPE pipe, ISI marked, along with all accessories like socket, bend, couplers, etc., conforming to IS 14930, Part II, complete with fitting and cutting, jointing, etc. Direct in-ground (75 cm below ground level), including excavation and refilling the trench, but excluding sand cushioning and protective covering, etc., complete as required. | ||||||||
| 4.01 | 63 mm dia (OD-63 mm & ID-51 mm nominal) | 365 | Mtrs | 140 ₹51,100 | 165 ₹60,225 | 95 ₹34,675 Lowest | 110 ₹40,150 | 175 ₹63,875 |
| 5.00Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of the following size in the existing RCC HUME/ METAL/DWC/ HDPE pipe as required. | ||||||||
Tender Value
₹5.5 L
Closing Date
6 Jun 2026, 5:00 pmClosed
The Director (i/c)
Trichy to Pudukkottai Main Road Tiruchirappalli 620 024
Supply, Installation, Testing and Commissioning of Street Lighting Works for the Proposed Parking Area near to the Academic Block of IIM Tiruchirappalli
2026_IIMT_907210_2
26SP009T
Open Tender
Miscellaneous Works
Works
30 days
IIM Tiruchirappalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
Exempted
15 Jun 2026
27 May 2026
8 Jun 2026
27 May 2026
6 Jun 2026
27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commissioning of pre-wired LED street light with pressure die cast housing and secondary lens delivering lumen level not less than 3600lumens and not more than 30W power, IP66 protection and 4kV inbuilt surge protection, THD<10%, PF>=0.95, 5700K pure white, conforms to IS 10322 Part 5 complete, including necessary interconnections and Earthing as required. (Approved makes: Bajaj/Philips/Havells/Crompton) | |||||
| 1.01 | On Octagonal Pole | - | Each | - | - |
| 2Supply and installation of a 3-meter-high Hot Dip Galvanized (HDG) octagonal pole made out of 3 mm thick hot rolled steel sheet having 130 mm bottom A/F and 70 mm top A/F, provided complete with a base plate of size 200 mm × 200 mm × 16 mm thick. The pole shall be erected on RCC foundation of mix 1:1.5:3 (1 cement : 1.5 coarse sand Zone-III : 3 graded stone aggregate of 20 mm nominal size) including necessary foundation bolts, excavation, cantering, shuttering, strutting, propping, placing in position and curing etc. complete. The work includes providing and placing Thermo-Mechanically Treated (TMT) reinforcement bars of grade Fe-500D or higher, including straightening, cutting, bending, binding and placing in position for RCC work up to plinth level, as per the pole manufacturer’s recommendations. The item shall also include: 1. Excavation and refilling of foundation pit 2. Finishing of foundation 3. Providing and fixing 6A DP MCB inside suitable enclosure 4. Providing 3 Core × 1.5 sq.mm flexible PVC insulated copper cable for interconnection between luminaire and MCB 5. GI sheet for cable gland mounting 6. Proper earthing arrangement 7. Two coats of epoxy primer and epoxy paint (Aluminium grey) All necessary civil and electrical accessories to complete the work in all respects as per pole manufacturer’s recommendation and as directed by Engineer-in-Charge. (Approved makes: Bajaj/RR Ispat/Crompton; MCB: Legrand/L&T; Cable: Polycab/RR Kabel/Finolex/Havells) | |||||
| 2.01 | With 0.5mtr long hot dip galvanized standard type Single armbracket made up of 40NB dia GI pipe suitable to mount on a pole having a top 70mm A/F. (Approved makes: Bajaj/RR Ispat/Crompton) | - | Each | - | - |
| 2.02 | With 1mtr long hot dip galvanized standard type Double armbracket made up of 40NB dia GI pipe suitable to mount on a pole having a top 70mm A/F. (Approved makes: Bajaj/RR Ispat/Crompton) | - | Each | - | - |
| 3Supply of FRLS XLPE power cable of 1.1 kV grade of the following sizes as required. (Approved makes: Polycab/RR Kabel/Finolex/Havells) | |||||
| 3.01 | 3C x 4 sqmm Aluminum armored cable | - | Mtrs | - | - |
| 4Supplying and laying of the following size DWC HDPE pipe, ISI marked, along with all accessories like socket, bend, couplers, etc., conforming to IS 14930, Part II, complete with fitting and cutting, jointing, etc. Direct in-ground (75 cm below ground level), including excavation and refilling the trench, but excluding sand cushioning and protective covering, etc., complete as required. | |||||
| 4.01 | 63 mm dia (OD-63 mm & ID-51 mm nominal) | - | Mtrs | - | - |
| 5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of the following size in the existing RCC HUME/ METAL/DWC/ HDPE pipe as required. | |||||
stage.html
html • 0.02 MB
finance_957012.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
009TStreetLightingAcademicOffice.pdf
Tender Documents • 0.57 MB
BOQ_957012.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .