Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.8 LAccepted-AOC | ₹10.8 L | L-1 | Accepted-AOC AS PER CWC-II DECISION HELD ON 03/01/2025 |
| 2 | L-2₹12.3 L+₹1.5 L (13.6%)Rejected-AOC | ₹12.3 L+₹1.5 L (13.6%) | L-2 | Rejected-AOC AS PER CWC-II DECISION HELD ON 03/01/2025 |
| 3 | L-3₹12.4 L+₹1.5 L (14.1%)Rejected-AOC | ₹12.4 L+₹1.5 L (14.1%) | L-3 | Rejected-AOC AS PER CWC-II DECISION HELD ON 03/01/2025 |
| 4 | L-4₹12.7 L+₹1.8 L (17.0%)Rejected-AOC | ₹12.7 L+₹1.8 L (17.0%) | L-4 | Rejected-AOC AS PER CWC-II DECISION HELD ON 03/01/2025 |
Tender Value
₹12.5 L
EMD Value
₹25,100
Closing Date
5 Oct 2024, 2:45 pmClosed
CHIEF GENERAL MANAGER
O.F.Bhandara
Repairs to HT panels, HT overhead lines, HT underground cables, Transformers, HT 11 KV Air break switches etc. at estate and KWW area, at O.F.Bhandara.
2024_MIL_208309_1
EO/51/RD2402/BF
Open Tender
Electrical Works
Item Rate
365 days
O.F.Bhandara
AS per Tender document
7 documents required · 7 mandatory
₹0
₹25,100
Yes
6 Jan 2025
14 Sept 2024
7 Oct 2024
14 Sept 2024
5 Oct 2024
14 Sept 2024
Amount
M&L for Cable joint kit for 11000 V (E) graded cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitbale for 3 Core Cable, sizes from 50 sq.mm to 95 sq.mm XLPE insulated aluminium conductor. RPG Raychem/3-M/REPL make or equivalent.
M&L for Cable joint kit for 11000 V (E) graded cable for straight through termination heat shrink type joint complete with jointing material and accessories suitbale for 3 Core Cable, sizes from 50 sq.mm to 95 sq.mm XLPE insulated aluminium conductor. RPG Raychem/3-M/REPL or equivalent.
M&L for lightning arresters expulsion type complete with all fittings, transmissoin class, discharge capacity 65 Kilo Amp on 11000 V OH line. Make: ELPRO or any approved make as per IS standard & as directed by EIC
S& F galvanised steel wire 3.14 or 4 mm dia.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
S & F galvanised stay wire strand size 7/4mm.
S& F stay assembly complete with 20 mm dia. Stay rod and other assessories as shown in electrical plate No. 1. (Excavation and concrete, loop insulator and stay clamp to be mesaured separately)
Rough excavation in hard dense soil in trenches not exceeding 1.5 mtr deep & 1.5 mtr wide and getting out
Rough excavation in Mud in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out.
Rough excavation in hard rock in trenches not exceeding 1.5 mtr deep and 1.5 mtr wide and getting out
Back filling of excavated soil spreading, levelling, watering & well ramming in layers.
M & L fine sand filling in the trench for cushioning of cable /Substation trench filling.
Demolition and dismantling of Cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level).
M & L for remaking of concrete by PCC of 1:2:4 of type B-2 using 40 mm aggregate.
M&L for Galvanised steel tube medium grade 100 mm dia.
M&L for UN-REINFORCED PRECAST CONCRETE CABLE COVER , CLASS HV, TYPE 1, Flat, size 300mmX180mm X40 mm in the cable trench .
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed by EIC.
Labour only for Repairing/Fixing/Restringing/removing of ACSR / Copper / GI conductor of any size for repairing of HT OH lines per span per conductor.
Labour only for Rejointing of broken/ defective jumper wire/ cable lead/lug on HT pole by re-binding/ reluging.
Labour only for 11 KV HT OCB/VCB maintenance work like Cleaning, IR Testind, BDV Test of Oil, Contacts cleaning, Bushing, Overhauling, varnishing/ epoxy painting etc and as directed by EIC.
Labour only for maintenance of HT Panels (Excluding OCB/VCB) including busbar and cable chamber equipments, Insulators, Terminations, CT, PT, shutter mechanism, IR value testing and improvement, closing/tripping operation etc and as directed by EIC
Labour only for Transformer Oil top-up, Breather, IR Test, TF Oil BDV test, Earth Resistance test, Buchholtz Relay Test, bushings, valves etc. For transformer capacity from 100 KVA to 10 MVA and as directed by EIC ( Material will be provided by OFBa)
Labour only for Shifting of Indoor/Outdoor type Transformer, Panel, VCB/OCB, AB Swiches by dismanteling in good condition for reuse as directed by EIC ( Store to be hand over to OFBa)
Labour only for Triming of Tree branches on overhead line, Adjascent to DP/4-Pole Structure during Patrolling of HT Line etc as directed by EIC
Labour only for Dismantling of faulty Disc insulator, taking down ACSR conductor with turfer/tension arrangement, removing of jumpers or fixing of new Disc Insulator and tension hardware, restringing of ACSR conductor, re-jumpering, completeness of work and restoring power supply to healthy condition and as directed by EIC ( Materials will be provided by OFBa)
Labour only fo Dismantling of faulty Pin insulator, taking down ACSR conductor or fixing of new insulator (5 KN/10 KN), its hardware, pin, binding, jumpering etc and as directed by EIC ( Materials will be provided by OFBa)
M & L for epoxy insulation paint( Make STANVAC ; Product Code Z906 Provar Anti-tracking, Aerosol Spray, Can of 500 ml.) or it's equivalent and painting of insulated bus-bars, HT insulator, CT, PT, Cast Resin equipment damaged by partial discharge/Tracking of complete feeder and as direcetd by EIC ( Materials will be provided by Contractor)
Labour only for 11 KV Air Break Switch overhauling and maintenance as directed by EIC ( Materials will be provided by OFBa)
Labour only for dejungling/grass cutting under and adjascent to HT overhead line, Pole structures, substation surroundings etc.
M&L cable route marker fixing on existing under ground cabling with PCC base (300*300*200mm) including earth removing and refilling.( Route marker with MS angle and hardwares will be provided by O.F Bhandara)
Labour only for HT & LT under ground cable fault locating using cable fault locator instrument as directed by EIC ( Cable fault locator shall be arranged by Contrcator).
Labour only for Shifting of Cable drum , Laying & Connection of HT cable , Size 70 sq.mm to 240 Sq.mm only.(Cable will be supplied by O.F.Bhandara)
M&L for ready mix special grade asphalt (self grade) premixed with special aggregate and chemical plus pressure sensitive polymers for pavement surface /poth holes repair by cold application in wet or dry weather preferably insta patch.
Labour only for disconnecting/reconnection of HT cable in panel/ AB Switches/ Transformer for testing/ repairing/ maintenance of Cable per cable per end of any size and any type.
M&L for replacement of faulty DO fuse on Pole mounted Transformers of any rating as directed by EIC.
Labour only for removal/filling of sand in cable trenches during removal/maintenance of Cable/Panel etc.
Labour only for Patrolling/Inspection of HT Line/Cabling during searching of exact fault location.
M&L for Double wall Corrugated (DWC) Pipe of HDPE, Industrial grade heavy duty Type INSIDE dia should be greater than 107mm minimum suitable to fit to 100mm dia GI Pipes. Corrugation shall be on outer wall but inner wall shall be plain.
RAJESH ELECTRICAL CONSTRUCTION (BID ID -747269)
M B ELECTRICALS (BID ID -744823)
Swati Enterprises (BID ID -749930)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .