Loading…
Loading…
Tender ID
Tender Value
₹8.8 L
EMD Value
₹21,993
Closing Date
20 Mar 2026, 6:00 pmClosed
AE.LID EW ,S.Bathery BP
O/o Assistant Executive Engineer.LID EW , S.Bathery BP
Annual Plan Installation of Generator and Additional Electrical works at Animal Birth Control Building Sulthan Bathery Block General Electrical Work
2026_LSGD_846985_1
AE/LID-EW/BPSBY/07/2025-26
Open Tender
Electrical Works
Item Rate
180 days
Sulthan Bathery
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,940
Yes
₹21,993
Yes
12 Mar 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
20 Mar 2026
12 Mar 2026
DG SET
OD101211/2025-2026:Supply, Installation, Testing and Commissioning of 20KVA Diesel Generating Set conforms to present CPCB IV+ norms having 3 cylinder, liquid cooled, Turbocharged After-cooled, developing 25.2 HP at 1500 RPM. Enabled with electric start, compression ignition, 4 stroke engine designs to run continuously at 1500 RPM with installation of Exhaust pipe upto the top of building as per the norms DIESEL ENGINE COMPRISE OF FOLLOWING: Radiator with Fan . Electric starter motor with soft starting system . G2 class governor . Battery charging alternator . Dry type Air cleaner with service indicator . Flywheel Housing . Lube Oil & Fuel filter . First fill of lube oil, coolant ALTERNATOR: Suitable for continuous operation rated 20 kVA / 16 KW at 1500 rpm, 415 V, 0.8 PF, 50. Hz, 3 Ph. in SPDP enclosure, self-excited, self-regulated Brush less. The alternator conforms to IS: 4722, BS EN 60034-1 and must be suitable for tropical condition ACOUSTIC ENCLOSURE: The Enclosure is of modular construction. . Durable industrial locking system is provided on doors. The sheet metal components are 11 tanks pre-treated and is Polyester based powder coated (inside as well as outside) for long life. Specially designed sound attenuators are provided to control sound at air entry & exit points inside the enclosure. In - build draw in type fuel tank of suitable capacity. The walls of enclosure are insulated with the fire-retardant & noise absorbent foam/rock wool so as to comply with the noise level of 75dB(A) at distance of 1meter in open free field environment as per ISO 8528 part 10 specified by ministry of Environment & Forest. DG CONTROL PANEL WITH GENSET CONTROLLER: The Control Panel should be manufactured with CRCA sheet and is powder coated for a weather-proof and long lasting finish. The Control Panel consists of Microprocessor based Genset controller, MCB of suitable rating, Push Button (starter), LED Battery Charging alternator fail indication, Current Transformers, Instrument fuses etc complete as per KSEI Specifications. The Genset controller has all the basic safeties and protections. FUEL TANK: Daily service fuel tank 55 liters manufactured with sheet metal complete with drain valve, air vent, inlet and outlet connection. Suitable for minimum 8Hrs continuous running BATTERY: EXIDE make 12 V. Electrical Inspectorate Scheme approval and its related Paper works has to be completed by the Electrical contractor before the execution of work
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD101186/2025-2026:Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD101185/2025-2026:Supply and Installing 9 Liter capacity GI Fire bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/wall bracket filled with fine sand painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
OD101237/2025-2026:Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD101213/2025-2026:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system
OD101361/2025-2026:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate
OD101212/2025-2026:Supply, installation testing and commissioning of 1TR 3 star rated split Inverter type air- conditioner unit conforming to IS 1391(Part2/92) suitable for operation on 230V+/- 10% 50 Hz single phase AC supply fitted with hermetically sealed compressor operating on R22/ono CFC refringent with condensing and evaporating unit capable for cooling air circulation and filtering etc. Including refringent copper piping with insulation up to 5 Meter or required length microprocessor control with cordless remote control and providing wall mounting stand for the outdoor unit etc-Inverter AC (With extended two year warranty period). Blue star /LG. Along with Supply and Fixing of 4KVA Voltage stabilizer V Guard with input voltage of 170 -270V and Output Voltage range of 210 to 240V with Overload Protection time relay, Indicators and Chord Wire etc as required
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.22.3:Supply & installation of light fittings on flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
OD101225/2025-2026:Supply, Providing and fixing following capacity 4 Pole Onload Change over switch unit with cubical panel enclosure having LEDs for indication of supply including drilling hole, making connections, etc. as required.63 Amp
90.12.5.28:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
E146SBD.pdf
Tender Documents • 1.93 MB
BOQ_1431086.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .