Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 24 85 7 SANATH NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹1.1 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹1.1 Cr+₹2.3 L (2.07%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | ₹1.1 Cr+₹2.3 L (2.07%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹1.2 Cr+₹3.4 L (3.03%)Rejected-Finance DOOR NO 36 72 5 BOOSAVARI STREET REDDY KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹1.2 Cr+₹3.4 L (3.03%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹1.2 Cr+₹5.9 L (5.24%)Rejected-Finance | ₹1.2 Cr+₹5.9 L (5.24%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹1.2 Cr+₹8.2 L (7.26%)Rejected-Finance | ₹1.2 Cr+₹8.2 L (7.26%) | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
26 Mar 2024, 6:00 pmClosed
Col KK Srivastava, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
AS and AS and Special repairs to Sports office and TDEC Complex bldg No. P38 at INS Viswakarma and bldg No P 03 and P 06 at Naushakti vihar, Visakhapatnam
2024_MES_638797_1
82409/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class B and Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Depot
₹2.0 L
Yes
1 May 2024
6 Feb 2024
28 Mar 2024
6 Feb 2024
26 Mar 2024
9 Mar 2024
6 Feb 2024 - 13 Feb 2024
Amount
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5 KM complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5 KM complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5 KM complete all as specified and as directed.
Dismantling Timber framed works as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Taking wooden down shutters of any description exceeding 1 Sq.M but not exceeding 2 Sq.M each and removing to or from store.complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish/ debris to a distance exceeding 1.50 KM but not exceeding 5 KM complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled with power road roller of 8 to 12 ton capacity and consolidated to required gradient and camber complete all as specified.
M & L for Providing Precast Cement Concrete Solid Block Masonry of 1:3:6, Type C1 using 20mm graded stone aggregate exceeding 100mm width with plain or interlocking joints set in cement mortar 1:6 complete all as specified and as directed.
M & L for providing Precast RCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, chajjas, water troughs, mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 including use of necessary form work/ moulds, etc. complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate as in Coping, Bed blocks, holdfast blocks, cill and the like including weathering, slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.
Supply only approved integral water proofing compound all as specified.
M & L for treating the leakage/ seepage by providing Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting Cement Slurry mixed with Grout Admixture "CONBEXTRA E 100" of Fosroc or equivalent at 225 Grams for 50 KG of cement complete all as per manufacturers instructions and as directed.
M & L for preparing surfaces of sunken floor and applying two coats of Brush Bond of M/s Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed at site.
M & L for treating the leakage/ seepage by providing NITOTILE of Fosroc or equivalent grouting into the tile gaps in Toilets and Kitchens including pointing and finishing complete all as per manufacturers instructions and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made 35mm thick, Second Class Hard Wood, Plain framed, Panelled Shutter [Two Panel] with Lock Rail and Panel of 9 mm BWP Commercial Ply or 12 mm Veneered Particle Board with Commercial Veneering on both faces, the size of Rail and Stile as per IS – 1003 [Part – I], Kiln Seasoned and Chemically Pressure treated and fitted to Chowkats complete all as specified and as directed.
S & F Factory made 35mm thick , Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [a] and fitted to Chowkats complete all as specified and as directed.
S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm WPC sheet reinforced with MS square tube in opening of Sintex ot its equivalent make as approved by GE complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Factory made PVC Ventilator made out of multi chamber PVC hollow section DWUF 405 [40x46mm] with 3mm pin headed glass fixed to the lower section using extruded PVC section of 9 X 19.5mm size OL19 with EPDM gasket [SPL 003] for both PVC sections, ventilator's centre mullion shall be made up of multi chamber hollow PVC section DWUF-406 [63.5mmX40mm] with EPDM gasket GL-19 and fixed to the 3 sides of DWUF-405 and DWUF 406 [63.5X40mm] above the centre mullion, Glass panels with aluminium lower set shall be fixed to the frame DWUF-405 on the top of the ventilator for the glass, DWUF 405 and DWUF 406 comers shall be mitred cut and welded, jointed with 12mm MS Rods [Guard Bars] including necessary fixtures complete all as specified and as directed.
M & L for Powder coated aluminium sections [Minimum 50 Micron thick] of approved colour for Doors, Windows, Ventilators, Partitions with frame and shutters fully or partly glazed, sliding / openable including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangements etc., complete all as specified and as directed. Notes: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates. [c] Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. [d] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangements etc., and fixing only of panel inserts of glass / particle board / gauge etc.
S & F 4mm thick Figured Glass or Pin headed Glass and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm alongwith tinned tacks or Aluminium wire staples complete all as specified and as directed.
S & F in repairs Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or Aluminium wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.
S & F aluminium powder coated grill of make "Deco grill" of DG - 104 model with apperture of size 105 x99 mm with suitable outer channel 'U', ''F'' or ''E'' section fixed to window/ventilator frame for securing Deco grill and interlock and secruing the frame to masonry wall with brass screws complete all as specified and directed.
S & F in repairs 19mm thick, Prelaminated Particle Board, One Side Decorative Choice Lamination and other side Balancing White, Medium Density, Interior Grade fixed with screws to timber frame work complete all as specified and as directed.
S & F 100 mm size, Butt hinges, Extruded Aluminium alloy with galvanised mild steel hinge pin, anodised, Type C-21, including fixtures complete all as specified and as directed.
S & F 100mm size, medium weight Butt Hinges, cold rolled, mild steel including fixtures complete all as specified and as directed.
S & F Aluminium anodised Handle of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 100 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F in repairs Harrison Rails [Curtain Rails], Mild steel CP with fixing brackets, stops, rollers etc complete all as specified and as directed.
S & F in repairs Hasp and Staple, safety type of aluminium anodised including bolt to hinge plate, fixed with screws of 100mm size complete all as specified and as directed.
S & F in repairs 300mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S & F in repairs Door Closer, aluminium body, Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
S & F Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 316L, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 8mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
S & F in repairs False Ceiling Frame Work using Anodised Aluminium snap grid frame work of 600 X 600 mm panel size for false ceiling with Aluminium "T" section of size 38 X 25 X 1.50 mm thick for Main Runners, 25 X 25 X 1.5 mm thick for Cross Runners and Angle of size 25 X 25 X 1.50 mm thick along the Walls suspended with and including 6 mm dia, Galvanized mild steel wire as in suspenders of ceiling members fixed in proper position with 60mm long GI cleats of size 40 x 3mm fixed to ceiling with suitable expandable fasteners including fixing Gypsum board of 12 mm thick conforming to IS - 2095 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres and including applying two coats of Acrylic washable Distemper over a coat of Alkali resistant primer complete all as specified.
M & L for 100 mm thick PCC 1:3:6, Type C-2, using 40 mm graded stone aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, Type B-0, using 12.5 mm graded stone aggregate as in leveliing course/ Sub base for flooring complete all as specified and as directed.
M & L for 75 mm thick PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Flooring/ hardstanding/ plinth protection, surface finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Vitrified Tiles, Double Charged, Coloured, dark shade, Premium Quality of size not exceeding 0.36 Sq.m, 8 to 9 mm thick as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, dark shade, Premium Quality of size not exceeding 0.36 Sq.m, 8 to 9 mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Marble Stone Slabs of 18 to 20 mm thick of Green Colour as in Flooring, Treads and Risers of Steps, Landings of Staircase etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, slabs shall be of design / pattern as directed, including inlays, borders, margins, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious joint filler to match the shade of the Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire width of Steps, Risers & Landing etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for Chequered Cement Concrete Tiles of size 250 X 250 mm / 300 X 300 mm, 22mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 of cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4 and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for One coat of white wash on old decorated surfaces of wall including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for One coat of white wash on old decorated surfaces of ceiling including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces by using vaccume based sanding machine and applying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer on ceiling over 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on wall surfaces by using vaccume based sanding machine, removal of nails and applying two or more coats of Cement based Wall Care Putty on walls to obtain an even surafce by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Fire resistant paint by using auto roller/ airless sprayer over one of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer of same manufacturer as that of paint on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed. Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting and allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on walls surfaces by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed. Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting and allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Preparing surfaces of wood and wood based materials, steel and iron work new or old, of any description and girth not otherwise described, and treating ends of posts, backs of Chowkats, etc. area tarred not exceeding 0.1 Sq.m each with tar or coal tar black paint complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for One coat of synthetic enamel paint on old painted wooden surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for One coat of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Double Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including dismantling and taking out existing unserviceable PVC tanks of any description and capacity complete all as specified and as directed.
M & L for Cleaning of water tanks of capacity not exceeding 250 Litres and removing all scale dirt etc. from tanks and from mouths of circulating pipes complete all as specified and as directed.
S & F in repairs Ball Valves, 25 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc complete all as specified and as directed.
S & F 16 mm outer diameter CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed.
S & F CPVC Pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing including taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed.
S & F in repairs Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
S & F in repairs Two way angle Cock, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed. Make: Jaquar Catalogue No. OPP-15041PM or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine
S & F in repairs Angle Cock, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as specified and as directed. Make: Jaquar Catalogue No. OPP-15053PM or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree
S & F in repairs Health Faucet, ABS body, including 1.25 m long flexible tube, ABS wall hook, non return valve complete all as specified.
S & F in repairs Stop Valves, 15 mm bore dia of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repairs, Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
S & in repairs F Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe complete all as specified and as directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, of size 580 x 440 mm including flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap including taking down of existing unserviceable water closet complete all as specified and as directed.
S & F in repairs Vitreous china urinal, bowl type, flat back, white of size 465 X 355 X 265mm, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, grating and union for discharge pipe, Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe [Minimum weight 60 Grams] etc. complete all as specified and as directed.
S & F in repairs 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle including brackets and connections to pipe and flush pipe complete all as specified and as directed.
S & F in repairs PVC Connection of 15mm Bore and 450mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs 100mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
S & F 75mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes including taking up / down unserviceable / cracked cast iron pipes 75mm dia including taking out joints and fittings of any type complete all as specified and as directed.
S & F 110mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes including taking up / down unserviceable / cracked rain water pipes including taking out joints and fittings of any type complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore UPVC [SWR] Junction Single [Single "Y"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore UPVC [SWR] Junction Single [Single "Y"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
M & L for 100 dia for Salt Glazed Stoneware Drain Pipes of Grade "A" laid in trenches and jointed including Demolition and breaking up drain pipes [Salt glazed ware, AC or Reinforced concrete] of any diameter set in cement mortar complete all as specified and as directed.
M & L for 150 dia for Salt Glazed Stoneware Drain Pipes of Grade "A" laid in trenches and jointed including Demolition and breaking up existing drain pipes [Salt glazed ware, AC or Reinforced concrete] of any diameter set in cement mortar complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 100 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate including demolition of existing concrete bed complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate including demolition of existing concrete bed complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
Taking down existing unserviceable Sub main wiring of any description and size from any position alongwith wooden battens / conduits / casing capping including making good the disturbed surfaces to match with the adjacent surfaces complete all as specified and as directed.
Taking down MCCB DBs, MCB DBs, SPN / TPN Enclosures alongwith MCCBs, MCBs etc of any description and any capacity and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point complete all as specified and as directed. Note: The rate quoted shall be deemed to include cost of cutting chases not exceeding 10 cm girth, pinning in brick walls and making good in cement mortar as required.
All as per Serial Item No. 111 above but One light point controlled by 2 Nos of Two way switches complete all as specified.
All as per Serial Item No. 111 above but one 3 Pin Socket Outlet 6 Amps on independent board, complete all as specified.
All as per Serial Item No. 111 above but One 3 Pin Socket Outlet 6 Amps on same Board with other switches complete all as specified.
All as per Serial Item No. 111 above but one 3 Pin Socket Outlet 16 Amps power point on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
M & L for Sub main wiring with 2 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as per existing complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as per existing complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps cum 3 pin 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Bell Push, Modular type, one module, Single Pole, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Bell, Ding Dong / Multi Music Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repairs Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F in repairs Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F MCCB DB, VTPN, 4 Way, 415 Volts with DIN Channel, N3 Frame, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 100 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 100 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F MCB DB, SPN, 4Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F MCB, TPN, 40-100 Amps, 10 KA, C Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SPN, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SPN, 40 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB 415 V , 16 KA, 4 Pole, 100 Amps capacity complete all as specified and as directed.
S & F MCCB 415 V , 16 KA, 4 Pole, 63 Amps capacity fixed in and including suitable factory made sheet metal enclosure flush mounted with wall complete all as specified and as directed.
S & F MCCB 415 V , 36 KA, 3 Pole, 500 Amps capacity with adjustable thermal and magnetic settings fixed in and including suitable factory made sheet metal enclosure flush mounted with wall complete all as specified and as directed.
S & F MCCB 415 V , 36 KA, 3 Pole, 160 Amps capacity with adjustable thermal and magnetic settings fixed in and including suitable factory made sheet metal enclosure flush mounted with wall complete all as specified and as directed.
S & F RCCB, DP, 30mA, 40/ 63A , 230 Volts, complete all as specified and directed.
S & F SPN sheet metal enclosure, Modular type, with two pin and earth plug and socket, with and including One MCB, SP, 20 Amps, 10 KA, C curve, 240 Volts complete all as specified and as directed.
Taking down Light Fittings of any description and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning and minor repairs complete all as specified and as directed.
S & F in repairs Square recess mounted Flat Panel LED Light fitting 2' x 2' size, not less than 3600 Lumens output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing LED light fittings of any description and making good the disturbed surfaces to match with existingcomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1800 Lumens output, 5700 K of cool white, with extruded aluminium housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing LED tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing LED tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 900 Lumens output, 5700 K of cool white, comprising of batten with necessary polycarbonate diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Recess mounted LED Downlight, Round type of not less than 1000 Lumens output, 6000 K with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Energy efficient & Long life Security Light Luminaire, 35 Watt with Pressure die-cast Aluminium housing, IP 65 Protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 2.00 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Security light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient LED Bollard light fittings of not less than 1000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, with Opal Acrylic Diffuser, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Integral LED Aviation Light comprising of aluminium housing with polycarbonate enclosure including standard fixing arrangements and connecting up complete all as specified and as approved. Note: Light fitting shall be of PF>0.95 Make: Cat No. BGAV 302 LED of M/s. Bajaj or equivalent approved model in Philips/ Cropmton/ Havells
S & F in repairs LED Bulb of not less than 700 Lumens output, 3000 K, IP40 operating voltage 90-270 Volts, AC, 50 Hz, Natural white colour including holder complete all as specified and as directed.
S & F in repairs LED Bulb of not less than 1500 Lumens output, 3000 K, IP40 operating voltage 90-270 Volts, AC, 50 Hz, Natural white colour including holder complete all as specified and as directed.
Supply and fix Single Phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed.
S & F Energy efficient, BEE 5 Star rated Storage type Water Heater [Geyser] 25 Litres Capacity with 2000 Watt Capacity heating element Conforming to IS - 2082, Vertical Storage type with Stainless Steel Inner Tank and ABS Outer Shell complete fixed to wall with suitable expansion fasteners including 02 Nos. of 450 mm long x 15mm dia Stainless Steel braided Flexible Hot & Cold Water connections and 15mm bore Non-Return Valve complete all as specified and as directed. Note: Ceiling Fan shall be provided with 05 Years onsite replacement warranty. Rate quoted is deemed to be including the same and nothing shall be paid extra on this account.
S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep of any colour as approved, 03 blades, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 374, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, including Down Rod, Canopies, Shackles, Safety Rope, Hanging Clamps, Bushes, having P.F >0.95, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% including provision of Electronic speed control Regulator step type, including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing unserviceable ceiling fans of any description and size and depositing into MES stores complete all as specified and as directed. Note: Ceiling Fan shall be provided with 03 Years onsite replacement warranty. Rate quoted is deemed to be including the same and nothing shall be paid extra on this account.
S & F Exhaust Fan, 300mm Sweep, 1400 RPM, Metal Body, Heavy Duty with Double Ball Bearing, generally Conforming to IS-2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill / Guard and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and taking down existing exhaust fan of any description and depositing at MES Store Yard complete all as specified and as directed.
S & F Exhaust Fan, 250mm Sweep, 1400 RPM, PVC Body, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter/ Grill and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match including taking down existing unserviceable exhaust fans of any description and size and depositing into MES stores complete all as specified and as directed. Make: Crompton Greaves / Havells / Almonard / Bajaj / Orient
M & L for Taking down existing Ceiling Fan of any description and refixing the same after repairs to buildings at same location or at new location, connecting up and testing including provision of Spares such as Capacitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts, three core PVC insulated sheathed flexible copper conductor cable of size 1.5 Sq.mm, etc. as required including rewinding the motor using super enameled copper conductor of suitable gauge including insulation, varnishing, packing, testing and refixing into the fan including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Nuts & Bolts, washers, three core PVC insulated sheathed flexible copper conductor cable of size 1.5 Sq.mm, etc. as required including rewinding the motor using super enameled copper conductor of suitable gauge including insulation, varnishing, packing, testing and refixing into the fan including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for Servicing of Solar water heater including solar panel,cleaning,brazing,welding and jointing of inlet outlet pipes, tanks,solar panels etc as per site requirement and testing and checking of solar water heater and making in working condition using all necessary minor spares, pipe joints (Tee,Elbow,Nipple etc)complete all as specified and as directed.
Taking down indoor and outdoor units of Split/ Window type Air Conditioner of any capacity and of any description carefully from its position including Servicing of Air conditioner electric blower, motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, grills etc and checking of all the electrical connections including replacing of copper pipes of suitable size including providing suitable insulation, topup/refilling the refrigerant gas af required and replacement of Nuts & Bolts etc. and re-fixing the Air conditioner after repairs to buildings, at same location or at new location as directed including connecting up and testing complete all as specified and directed. Notes: [a] The Rate quoted by the contractor is deemed to be inclusive of safe custody of the Air Conditioers during B/R repair works including cleaning the AC units, carrying out minor repairs and making good any damages caused during the custody to match with the original fitting complete all as specified and as directed. [b] The rate quoted by the contractor is deemed to be inclusive of Provn of making holes/core cutting in wall for passing of PVC pipe for indoor/outdoor unit with provision of PVC pipe .
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with stranded aluminium conductor 1100 Volt grade of size 4 Core, 10 Sq.mm cross section suitable for earthed system, laid in floor / duct or fixed to poles/ walls or drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old Cables of any description complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with stranded aluminium conductor 1100 Volt grade of size 3.5 Core, 35 Sq.mm cross section suitable for earthed system, laid in floor / duct or fixed to poles/ walls or drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old Cables of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Earth continuity conductor or main earthing lead made of 4 mm GI Wire [Earth Lead] , fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
SREE CONSTRUCTIONS
CHAMUNDESWARI ENTERPRISES
TECHNO SOFT SOLUTIONS
P SRINIVASA RAO
S A R CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .