Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.1 CrRejected-Finance | ₹2.1 Cr | L2 | Rejected-Finance As per recommendation of Financial Evaluation Committee |
| 3 | L3₹2.2 CrRejected-Finance | ₹2.2 Cr | L3 | Rejected-Finance As per recommendation of Financial Evaluation Committee |
| 4 | L4₹2.2 CrRejected-Finance | ₹2.2 Cr | L4 | Rejected-Finance As per recommendation of Financial Evaluation Committee |
| 5 | Rejected-Technical CHANGANACHERRY GENERAL ELECTRICAL WORK | ERNAKULAM | KERALA | 682001 | - | - | Rejected-Technical As per recommendation of Technical Evaluation Committee |
| Sl No | Description | Qty | Unit | GEORGE THOMAS L2 | Prathiba Developers (P) Ltd. L4 | CUBIX INFRASTRUCTURES L1 | DELMANN CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|---|
| 1.00Civil Works | |||||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer - in - charge. All kinds of soil | 353.57 | cum | 323 ₹1,14,202.79 | 150 ₹53,035.35 Lowest | 250 ₹88,392.25 | 395 ₹1,39,659.76 |
| 1.02 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 50 | cum | 125 ₹6,250 Lowest | 200 ₹10,000 | 130 ₹6,500 | 144 ₹7,200 |
| 1.03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 150 | cum | 100 ₹15,000 Lowest | 150 ₹22,500 | 300 ₹45,000 | 285 ₹42,750 |
| 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 84.55 | cum | 7,139 ₹6,03,602.45 | 7,000 ₹5,91,850 Lowest | 7,800 ₹6,59,490 | 7,140 ₹6,03,687 |
| 1.05 | Providing and applying antitermite treatment by spraying chemical in excavated pit and trenches for foundation and plinth beam and after back filling in the filled earth, complete building foot area and sides including all cost of material and labour charges (plinth area only to be measured for payment | 600 | sqm | 60 ₹36,000 Lowest | 110 ₹66,000 | 75 ₹45,000 | 125 ₹75,000 |
| 1.06 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more | 16,350 | kg | 101 ₹16,51,350 | 90 ₹14,71,500 Lowest | 90 ₹14,71,500 Lowest | 102 ₹16,67,700 |
| 1.07 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | 31,330 | kg | 101 ₹31,64,330 | 92 ₹28,82,360 | 90 ₹28,19,700 Lowest | 102 ₹31,95,660 |
| 1.08 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is not less than @330 kg/cum. All work upto plinth level | 111.81 | cum | 10,500 ₹11,73,973.5 | 9,000 ₹10,06,263 Lowest | 9,930 ₹11,10,243.51 | 9,800 ₹10,95,708.6 |
| 1.09 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is not less than @330 kg/cum. All work above plinth level upto floor V level. | 198.7 | cum | 11,500 ₹22,85,004 | 9,750 ₹19,37,286 Lowest | 9,930 ₹19,73,051.28 | 11,630 ₹23,10,834.48 |
Tender Value
₹2.3 Cr
EMD Value
₹1 L
Closing Date
19 Feb 2026, 3:00 pmClosed
THE REGISTRAR
CUSAT, Kochi-22
Construction of Central Academic Block at the Department of Ship Technology utilizing the CSR funds of M/s. Mazagon Dock Shipbuilders Ltd. (MDL).
2026_CUSAT_834041_1
CUSAT/ET-54 (Civil and Electrical)/5371/25-26
Open Tender
Civil Works - Buildings
Item Rate
545 days
CUSAT, Thrikkakara Campus
One single Civil work costing One Crore or above within 3 years for Government/Semi Government Clients.
8 documents required · 8 mandatory
₹9,794
₹1 L
Engineering Department, CUSAT
1 Apr 2026
6 Feb 2026
24 Feb 2026
6 Feb 2026
19 Feb 2026
6 Feb 2026
11 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Civil Works | |||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer - in - charge. All kinds of soil | 0.6 | cum | - | - |
| 1.02 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | - | cum | - | - |
| 1.03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | - | cum | - | - |
| 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 1 | cum | - | - |
| 1.05 | Providing and applying antitermite treatment by spraying chemical in excavated pit and trenches for foundation and plinth beam and after back filling in the filled earth, complete building foot area and sides including all cost of material and labour charges (plinth area only to be measured for payment | - | sqm | - | - |
| 1.06 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more | - | kg | - | - |
| 1.07 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | - | kg | - | - |
| 1.08 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is not less than @330 kg/cum. All work upto plinth level | 0.8 | cum | - | - |
| 1.09 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is not less than @330 kg/cum. All work above plinth level upto floor V level. | 0.4 | cum | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
ApprovedMakeList-CivilandElectrical.pdf
Other Document • 0.53 MB
PlansMerged.pdf
Other Document • 5.83 MB
Pre-QualificationDetails.pdf
Other Document • 0.63 MB
Tenderform.pdf
Tender Documents • 0.60 MB
Agreementform.pdf
Additional Documents • 0.01 MB
Epaymentform.pdf
Additional Documents • 0.05 MB
BOQ_1402904.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].