Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAdmitted-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹22.9 L | L1 | Admitted-Finance |
| 2 | L2₹22.9 LAdmitted-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | ₹22.9 L | L2 | Admitted-Finance |
| 3 | L3₹25.9 LAdmitted-Finance | ₹25.9 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RASAM ENGINEERING COMPANY L1 | BK CONSTRUCTION L2 | Onkar Electricals L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter in depth for taking out cable/ pipe line not exceeding 10 sq meter on plan and not exceeding 1.5 meter depth and getting out in soft/ loose soil complete all as specified and as directed.
Note:- (i) During the excavation damage of Road, Electric cable, Signal Cable should be rectified by the contractor without any extra cost.Surface should be matched as existing road.
(ii) Digging shall be carried out by manual means only. | 295 | CUM | 290 ₹85,550 | 240 ₹70,800 | 300 ₹88,500 |
| 2.00 | Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm. | 185 | CUM | 70 ₹12,950 | 120 ₹22,200 | 80 ₹14,800 |
| 3.00 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point. | 110 | CUM | 70 ₹7,700 | 140 ₹15,400 | 80 ₹8,800 |
| 4.00 | M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.Note : Punned thickness of sand shall measured and paid. | 72 | CUM | 950 ₹68,400 | 1,250 ₹90,000 | 1,500 ₹1.1 L |
| 5.00 | M & L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise all as directed | 9 | Per 1000 | 7,500 ₹67,500 | 7,000 ₹63,000 | 9,000 ₹81,000 |
| 6.00Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :- | ||||||
| 6.01 | 120 Sqmm 3.5 core | 250 | RM | 40 ₹10,000 | 60 ₹15,000 | 90 ₹22,500 |
| 6.02 | 95 Sqmm 3.5 core | 100 | RM | 40 ₹4,000 | 60 ₹6,000 | 80 ₹8,000 |
| 6.03 | 70 sqmm 3.5 core | 150 | RM | 30 ₹4,500 | 60 ₹9,000 | 75 ₹11,250 |
| 6.04 | 50 sq mm 3.5 core | 250 | RM | 30 ₹7,500 | 50 ₹12,500 | 50 ₹12,500 |
Updated dates
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
25 May 2026, 6:00 pmClosed
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2026_MES_762555_1
8978
Open Tender
Electrical and Maintenance Works
270 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
GE ARMY BARODA
₹42,000
Yes
30 May 2026
28 Apr 2026
26 May 2026
28 Apr 2026
25 May 2026
13 May 2026
29 Apr 2026 - 5 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter in depth for taking out cable/ pipe line not exceeding 10 sq meter on plan and not exceeding 1.5 meter depth and getting out in soft/ loose soil complete all as specified and as directed.
Note:- (i) During the excavation damage of Road, Electric cable, Signal Cable should be rectified by the contractor without any extra cost.Surface should be matched as existing road.
(ii) Digging shall be carried out by manual means only. | 295 | CUM | - | - |
| 2 | Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm. | 185 | CUM | - | - |
| 3 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point. | 110 | CUM | - | - |
| 4 | M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.Note : Punned thickness of sand shall measured and paid. | 72 | CUM | - | - |
| 5 | M & L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise all as directed | 9 | Per 1000 | - | - |
| 6Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :- | |||||
| 6.01 | 120 Sqmm 3.5 core | 250 | RM | - | - |
| 6.02 | 95 Sqmm 3.5 core | 100 | RM | - | - |
| 6.03 | 70 sqmm 3.5 core | 150 | RM | - | - |
| 6.04 | 50 sq mm 3.5 core | 250 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tenderpages8978.pdf
Tender Documents • 0.42 MB
BOQ_854173.xls
BOQ • 6.70 MB
Download all tender documents and submit your bid