Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Ist₹1.7 LAccepted-Finance | Ist | Accepted-Finance ACCEPTED | |
| 2 | IInd₹1.7 LAccepted-Finance | IInd | Accepted-Finance ACCEPTED | |
| 3 | IIIrd₹1.7 LAccepted-Finance | IIIrd | Accepted-Finance ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
12 Jul 2024, 12:00 pmClosed
Executive Engineer
EXECUTIVE ENGINEER ELECTRICITY 400 KV SUBSTATION DIVISION DAHI CHOWKI UNNAO
GPS SURVEY PREPARATION AND PROVIDING OF VARRIOUS DETAILED DRAWINGS ELECTRICAL LAYOUT OF ADDITIONAL 4TH 160MVA TRANSFORMER
2024_UPTCL_926172_1
02/ESDU/2024-25
Open Tender
Miscellaneous Services
Fixed-rate
30 days
Electy 400 KV Substation Dahi Chowki Unnao
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer
₹2,000
19 Jul 2024
5 Jun 2024
12 Jul 2024
5 Jun 2024
12 Jul 2024
6 Jun 2024
Amount
For Existing substation switchyard of 400 kV Unnao Ss:- Carrying out GPS Survey, Feasibility study, providing technical consultancy & giving best option for feasible arrangements/ layouts with the need of future requirements and preparation of detailed drawings (SLD/ ELD and ES) of 400 KV Sub-Station, Unnao on as is where is basis for illustration of Ss Steel Structures, T/Fs, Equipment, Bus-Bars etc. along with marking the boundaries & General arrangement of all Structures, Equipments, Installations. Bus-Bars/ Bays of all voltage levels including jumper interconnections along with all the empty Spaces/ Land in the Switchyard & adjoining area under UPPTCL after necessary Survey at site. The detailed drawings including necessary revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for 400 kV Unnao.
(2x315+1X500) MVA, 400/220KV ICTs Switchyard area including 12Nos 400KV Bays with 400KV Double Main and Transfer Bus Scheme, at 400 kV Substation Unnao.
For Exixsting substation switchyard of 220 kV at 400kV Unnao Ss GPS Survey, Feasibility study, providing technical consultancy and preparing and then submitting best options for extension of existing 220 kV substation (external electical system) in the vacant space (Approx. area 68X88=5984 Sq. Mtr.) with 07 nos 220 kV Feeder bays, 06 nos T/f bays, 01 no TBC and 01 no Bus coupler bay with Double Main and Transfer Bus scheme with suggestion of extension for addition of 4th 220/132KV, 160MVA T/F and its HV 220 kV bay. The detailed drawings including necessary revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for proposed 220 kV extension substation at 400kV S/S Unnao.
(3x160) MVA, 220/132KV ICTs Switchyard area including 15 Nos 220KV Bays with 220KV Double Main and Transfer Bus Scheme, at 400 kV Substation Unnao (Total Area approx. 46000 S.Q. Mtr.).
For incresing capacity and modifications in switchyard at 400kV Unnao Ss Carrying out GPS Survey, Feasibility study, providing technical consultancy & giving best option for feasible arrangements/ layouts with the need of future requirements and existing and detailed modified Electrical Drawings of 132 kV switchyard at 400kV Sub-Sation Unnao, showing proposed shifting of existing Bays & extension for addition of 4th 220/132KV, 160MVA T/F and its LV 132 kV bay including required proposal for making 132KV Double Main Bus and addition of new 132KV Transfer Bus schemes along with shifting/ modification as needed to accomodate required installations on as is where is basis for illustration of SS Steel Structures, T/Fs, Equipment, Bus-Bars etc. along with marking the boundaries & General arrangement of all switchyard Structures, Equipment, Installations. Bus-Bars/ Bays of all voltage levels including jumper interconnections along with all the empty Spaces/ Land in the Switchyard & adjoining area under UPPTCL after necessary Survey at site. The detailed drawings including necessary required revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for 132 kV system.
GPS Survey of 132 kV Switchyard, Preparation & Providing of detailed modified Electrical Layout Drawing of 132 kV switchyard at 400kV Sub-Sation Unnao showing proposed shifting of existing Bays & extension for addition of 4th 220/132KV, 160MVA T/F and its LV 132 kV bay including required proposal for making 132KV Double Main Bus and addition of new 132KV Transfer Bus schemes along with proposal for connecting 132KV Main Bus of 132KV S/S Sonik indivisually from each 132KV Main Bus including possibility to emanate at least 03 Nos. 132KV Feeders along with shifting/ modification as needed to accomodate required installations, site survey to explore technical feasibility on A-l size sheet and soft copy.
Preparation and submission of detailed survey and profiling report for shifting of 132KV Sonik-Chakalvansi Line, 132KV Sonik-Hasanganj Line and 132KV Sonik-Mohan Road Line to terminate at modified 132KV Switchyard of 400kV Sub-Sation Unnao alongwith detailed tower schedule and GPS coordinate matching with SS gantry.
Survey including preparation of schedule of materials, marking of locations (Route length), GPS Survey of line with co-ordinates of each tower for above 132KV Lines (The length of line shall be authenticated by GPS Survey).
lodhi switchgear enterprises
PRADEEP KUMAR PANDEY
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .