Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAdmitted-Finance | ₹4.1 L | L1 | Admitted-Finance |
| 2 | L2₹4.2 LAdmitted-Finance 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 UDYAM JH 02 0001826 | CHATRA | JHARKHAND | 825321 | ₹4.2 L | L2 | Admitted-Finance |
| 3 | L3₹4.3 LAdmitted-Finance GUNJARDIH BHANDARIDAH BOKARO JHARKHAND PIN NO 829132 | BOKARO | JHARKHAND | 829132 | ₹4.3 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S R.N. ELECTRICAL WORKS L1 | ARJUN ENTERPRISES L2 | MAHTO ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.01 | Dismantling of old defective lights from pole | 140 | nos | 190 ₹26,600 | 192 ₹26,880 | 210 ₹29,400 |
| 1.02 | Replacement of old defective lights with new lights and fitting of new lights on the pole | 140 | nos | 220 ₹30,800 | 222 ₹31,080 | 230 ₹32,200 |
| 1.03 | Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 1x1.5 sq.mm (for light connection) (100 nos. x 3 mtr. Average) | 300 | mtr | 100 ₹30,000 | 102 ₹30,600 | 120 ₹36,000 |
| 1.04 | Dismantling of 02 wire system OH line (10 span) & 03 wire system OH line (5 span)
(02*40mtr*10 times*0.214)+ (03*40mtr*5 times*0.214) | 299.6 | kg | 65 ₹19,474 | 66 ₹19,773.60 | 70 ₹20,972 |
| 1.05 | Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including
binding etc. as required.
Erection of 02 wire system OH line (10 span) & 03 wire system OH line (5 span) during blasting (02*40mtr*10 times*0.214)+ (03*40mtr*5 times*0.214) | 299.6 | kg | 195 ₹58,422 | 196 ₹58,721.60 | 210 ₹62,916 |
| 1.06 | Providing of RCC Pole of 8 mtr | 10 | nos | 5,500 ₹55,000 | 5,600 ₹56,000 | 5,700 ₹57,000 |
| 1.07 | Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. | 10 | Nos. | 4,800 ₹48,000 | 4,800 ₹48,000 | 4,900 ₹49,000 |
| 1.08 | Clearing tree branches including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the
periphery of the area cleared. 700 mtr. x 2 mtr. X 1 side | 700 | Sqm | 11 ₹7,700 | 11 ₹7,700 | 12 ₹8,400 |
| 1.09 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 4 | Set. | 5,400 ₹21,600 | 5,400 ₹21,600 | 5,500 ₹22,000 |
| 1.10 | Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) of specified size and shape including form work, plastering if specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/pipe not to be deducted) 2.5’ x 2’ x 2’ x 5 nos. x 0.0283 = 1.415 cum | 1.42 | cum | 5,400 ₹7,641 | 5,400 ₹7,641 | 5,500 ₹7,782.50 |
Tender Value
₹4.4 L
EMD Value
₹5,600
Closing Date
16 Mar 2026, 9:00 amClosed
PE EnM AADOCM
Office of PE EnM AADOCM
Improvement of lighting at siding along with maintenance of 440v/220v overhead line at AADOCM Dhori Area.
2026_CCL_355648_2
AADOCM/ENM/25-26/11
Open Tender
Electrical and Maintenance Works
7 days
AADOCM
Please refer tender document
2 documents required · 2 mandatory
₹5,600
24 Mar 2026
6 Mar 2026
17 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
6 Mar 2026 - 16 Mar 2026
Dismantling of old defective lights from pole
Replacement of old defective lights with new lights and fitting of new lights on the pole
Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 1x1.5 sq.mm (for light connection) (100 nos. x 3 mtr. Average)
Dismantling of 02 wire system OH line (10 span) & 03 wire system OH line (5 span) (02*40mtr*10 times*0.214)+ (03*40mtr*5 times*0.214)
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required. Erection of 02 wire system OH line (10 span) & 03 wire system OH line (5 span) during blasting (02*40mtr*10 times*0.214)+ (03*40mtr*5 times*0.214)
Providing of RCC Pole of 8 mtr
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.
Clearing tree branches including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 700 mtr. x 2 mtr. X 1 side
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) of specified size and shape including form work, plastering if specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/pipe not to be deducted) 2.5’ x 2’ x 2’ x 5 nos. x 0.0283 = 1.415 cum
Transporting of pole.
Supplying and erection of galvanised 'D iron clamps complete with shackle insulator (100 mm X 110 mm), GI bolts, nuts and washers, coach screws etc. as required.
Supplying and erection of 100 mm x 80 mm pin insulator complete with G.I. spindle and nuts etc. as required 220V grade.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as reauired.
Erection of angle iron/ channel iron cross arm on wood/RCC/PCC/ steel tubular/ rail pole etc. as required.
Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Supply of 10 SWG G.I. wire for cradling and earth continuity. 5 span x 29 lacing x 3.5 mtr. x 0.131Kg/m
Erection of cradle guard as required. 5 span x 29 lacing.
Providing and fixing of anti climbing device.
Clamp for fixing of light.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.70 MB
BOQ_368493.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid