Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹44.7 L+₹2.6 L (6.10%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹46.2 L+₹4.1 L (9.64%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹46.2 L+₹4.1 L (9.69%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹47.7 L+₹5.5 L (13.1%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
11 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
ADDN ALTN OF BLDG NO P 346 AND P 351 AT MIL STN DHRANGADHRA
2024_MES_650087_1
GE(A)/GNR/TOKEN/01 of 2024-25
Open Tender
Civil Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹87,000
Yes
5 Jul 2024
15 Apr 2024
13 May 2024
15 Apr 2024
11 May 2024
28 Apr 2024
15 Apr 2024 - 26 Apr 2024
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed.
Excacation of post holes (or simllar holes) each n. exc 0.5cum, and getting out insoft/loose soil retuting and filling in and ramming earth of brokrn rubble mixes with earch around in layers not exceeding 25 cm in soft/disintegrated rock completed all as specified and as directed.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for hard core of gauge exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface completed all as specified and directed.
M&L PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as specified and directed.
M&L PCC (1:3:6) C-2 using 40mm graded stone aggregate as in mass concrete as in foundation filling and mass concrete all as completed as directed.
Providing, cement concrete type B0 1:2:4 (12.5mm graded aggregate) for back filling of pressed steel frame etc complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping, benching, bressumers, steps, incl necessary formwork complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 with using 20mm graded stone aggregated for embedding of hold fast, filling etc. complete all as specified and directed.
M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed .
M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 except blocks, complete all as specified and directed .
M&L for reinforced cement concrete (nominal Mix) 1:2:4 type B-1 using 20mm stone aggregateas in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, underreamed piles and mass concrete complete all as specified and directed.
M&L for RCC 1:1.5:3 type A-1 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including demolition of existing RCC work in any position complete all as specified and directed.
Supply only polyester triangular fibrea as secondary reinforcement in all typeof concrete and mortars complete all as specified and directed.
Supply only Integral waterproofing compound complete all as specified and directed.
Supply & laying sub class 'B' bricks for protection of cable and laid perpendicular to the trench all as specified & directed by Engineer-in-Charge.
M&L for walling of random rubble stone masonry, brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for walling of random rubble, except stone, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm for sand stone and dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses completed as specified and directed.
M&L for granite/ trap stone kerb of roughly squared stones of sectional size 10 cm x 30 cm and not less than 45 cm length, all surfaces hammer dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 20 mm jointed in cement mortar 1:6 and struck flush complete all as specified and as directed.
Rough finished flat form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick complete all as specified and directed.
Rough finished flat Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide
S&F, Flush shutters, 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5 sq.m but not exc. 4 sq.m each complete all as specified and directed.
S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm and fixed complete all as specified and directed
S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
S & F Aluminium handles, cast type, anodised 150 mm long complete all as specified and directed.
S&F, 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
S&F mild steel in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including one shop coat of red oxide, zinc chrome primer complete all as specified and directed.
S&F M.S Framed work such as grills gratings etc with ends of bars sholdered and/or riveted into spikes ,framed guard bars /railings all as directed .
M&L for TMT 10mm dia bar and over, as in stiffeners, cut to length, bent to shape required, including cranking, bending, hooking ends, binding with and incluing mild steel wire(annealed) not less than steel wire 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT 6 to 8 mm dia bar, cut to length, bent to shape required, including cranking, bending, hooking ends, binding with and inlcuding mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips and confirming to FE-410-S and 310-0) complete all as specified and directed.
Fixing only rolled mild steel section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed.
S&F, rolled mild steel section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for rolled mild steel angle iron work as in door frames complete, drilled for fixing of hinges etc. also fastening and fixing conforming to Fe-290 (Gde-E-165) complete all as specified and directed.
S&F, in repair, galvanished, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm barvs dia barbs at 75mm spacinges and straining and fixing to any type of standard rails strining bolts including secuting or tying at crossinges with and provision of galvanished mild steel wire stapples or steel pins,etc complete all as directd and as specified
S&F, steel window with side hung shutters including box type hinges with steel handle, and steel tower bolt complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F, steel window with side hung shutters including box type hinges with steel handle, and steel tower bolt complete withiout glazing bars, dovetailed or welded complete all as specified and directed.
S&F factory made steel ventilators with top hung shutter including hinges, steel peg stay, glazing bars including applying one shop coat of red oxide primer all as specified and directed
S&F, 1.25mm thick pressed steel frames size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges (125mm long - 06Nos.& 75mm long - 2 Nos for each door), lock strike plate, etc. complete all as specified and directed.
S&F, in repair, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L cutting out cracks to V-section in existing roofs slab or terrae, cleaning out, wetting, grouting with cement and sand slurry 1:3 with mixing of WPC "2% by weight of cement complete all as specified and directed.
Taking/removing existing tar felt treatment of any description from RCC roof slab, terrace etc. by means of MS scrapper patty or any other suitable tools and removing to a distance 500 mtr from the starting point and depositing complete all as specified and directed.
M&L for water proofing treatment to roof surfaces including a coat of applied bituminous shalitex primer @ 0.30 litre/sqm eenly on roof surface and a coat of hot bitumen and 85/25 @ 1.2 Kg/sqm shall be applied on primed surface and laying 3mm thick APP modified polymeric membrane (weight not less than 3 Kg/sqm) unrolled and bonded completly to the substrate with side overlap of 75mm and end overlap of 100mm and then sealed/fused by flame or bitumen and a coat of hot blown bitumen grade 85/25 " 1.2 Kg/sqm shall be applied on top of AOO modified polymeric membrane as per manufacturer instruction and finally it will be finished with a coat of aluminium paint " 0.20 kg/sqm complete all as specified and directed .
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L for kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B2, using 40mm graded stone aggregate as in paving /hard standing/ path etc. finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 50 mm thick cement concrete 1:3:6 type C2, using 40mm graded stone aggregate as in plinth protection, finish even and smooth without using extra cement complete all as specified and as directed.
M&L for 25mm Thick Cement Concrete Type B-1, 1:2:4 (20mm Graded Aggregate) complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring finished fair and even to receive floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles joint free, any coloured / shed of size 450mm x 300mm x 7mm on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including rendering 10mm thick in cement mortar (1:4), complete all as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8 mm thick joint free tiles, (square/rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L, for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658- 2006 of 60mm thickness, M-35 grade, with grey cement & pigment insertion filled with sand and bedded with and including 50mm thick sand cousion laid uniformly and duly compected with plate vibrator complete all as specified and directed.
M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as sepcified and directed.
M&L for 10mm thick rendering in CM 1:4 on ceiling, soffits, chajja projection etc complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of concrete surfaces of roof as water proofing treatment in CM 1:4, including finishing the surface even and smooth complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on stone masonry surface or surface other than fair face of brickwork surface finished fair and even without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in two layers consisting of 5mm in CM 1:4 over 10mm thick in CM (1:6) plastering on stone masonry surface and rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for taking down, chipping and removing the loose, spailt, damaged cement concrete, cement mortor surfaces of RCC Columns, beams, walls, chajjah etc and exposing the reinforced cement , wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortor in CM 1:3 mix , 40mm thk in two coats, using polymer SBR Latex or equivalent as approved @ 5 Ltrs per 50 Kg bag of cement complete all as per manufacturer's Specifications/instructions and as directed. Note :-( New reinforcement (Welded wire fabric) will be measured and paid separately) Make : Dr. Fixit/Sunanda/chemestik/Fosrok
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coat of oild bound distemper over and including a layer of wall care putty to achive a smooth finish surface (average thickness 1mm) complete all as specified and directed.
M&L for preparation of old plastered surface by complete removal of existing treatment and applying two coat of oild bound distemper over and including a layer of wall care putty (average thickness 1mm) complete all as specified and directed.
M&L for preparing of plastered or unplastered old decorated surfaces of walls by complete removal of existing treatment, moulds, moss and efflorescent salt and treating oil and greasy spot and applying three coat of white wash on walls including cornices etc complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for two coats of exterior emulsion paint (weather coat of Berger or equivalent) over a coat of primer over a thin layer of external wall putty after complete removal of existing treatment complete all as specified and directed.
M&L for new plastered or un-plastered surfaces of finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied complete all as specified and directed.
S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq.m in each pane
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F, steel water tubes with rubber gasket at end of each pieces of pipe, light grade, galvanized, with all fittings of size 40mm dia laid in floors/trenches/fixed with poles for protection of cable complete all as specified and directed.
S&F, steel water tubes with rubber gasket at end of each pieces of pipe, light grade, galvanized, with all fittings of size 50mm dia laid in floors/trenches/fixed with poles for protection of cable complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars , block walling, ashlar fencings, dresed stone work including all quoins, etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc. 15cm thickness (below or above ground level) all as specified and directed.
M&L for demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete in any position not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed
Dismantling structural steel work including door , gatesbut excluding framed truss etc complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheet in roof covering
Dismantling barbed wire fencing, wire mesh, any type completed all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section, post embedded in concrete, birck work, masonry etc. including taking out embedded portion and making good disturbed ground completed all as specified and directed.
Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Material and labour for point wiring in steel conduit unsheathed multistrand copper conductor cable of 1.5 sqmm (for phase, neutral & earth) single core FRLS for one light/fan point controlled by one flame proof switch including continuouse earth continuity copper earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Note : (a) wiring shall be done by using proper colour coding.
S&F LED flameproof light fitting 2 x 16 Watts, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP65 protection with die cast aluminium housing with heat resistant toughned glass with LED tube light fixtures, driver, holder, connector etc. complete with all accessories pre-wired and including connecting up with three core flexible copper conductor wire of suitable size complete all as specified and as directed by Engr-in-Charge.
S&F Switch flame proof rotary type with termination box in LM6, 16 Amps, single pole 250 volts. Make : Sudhir Switchgears or equivalent complete all as specified and directed.
S&F Ceiling rose 3 terminal size 50x65mm surface type 230 volts complete all as specified and directed.
S&F Flame proof SPN DB 4 way 240 V having 200 A rated bus bars with 32 Amps SPN MCB-01 No and 16-32 Amps SP MCB's - 03 Nos complete all as specified and directed by Engr-In-charge.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Material and labour for copper strip of 20mm x 3.0mm with screws/ washers etc. over PVC saddles/spacers on wall and roof of building complete all as specified and as directed by Engr-in-Charge. Note : Max distance between spacers/saddles is 0.3 mtr complete all as specified and directed.
Material and labour for air termination, single pointed, copper rod 12 mm dia and 300mm long screwed properly on copper strip complete all as specified and as directed by Engr-in-Charge.
Material and labour for test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hax. head screw complete all as specified and as directed by Engr-in-Charge.
M&L for pipe Chemical earthing with GI pipe electrode 2.25m long having outer pipe nominal dia 80mm & inner dia 50mm dily filled with highly condictive and corrosive compound of required quantity having chemical Betonite 40%, Copper sulphate 20%, Gypsum 5%, Grafite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% Buried in ground digging a bore of 150mm dia surrounded by soil friendly backfill compound non solube in water including PCC pit with RCC cover etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:- [i] Excavation & earth work in any type of soil including removing of surplus material upto 50 M [ii] PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles and testing on completion complete all as specified and directed.
M&L for point wiring in & including PVC conduit concealed in brick or stone wall using FRLS PVC unsheathed multistrand copper conductor wire 1.5 sqmm (for phase, neutral & earth) single core including modular white cover plate with frame of suitable modules over modular metal flush box concealed type and earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge for the following :- Note : Wiring shall be done by using proper colour coding.
(a) One light/fan/bell point controlled by one switch one way
(b) 6 Amp socket outlet on independent board complete all as specified.
(c) 6 Amp socket outlet on same board complete all as specified.
(d) 6/16 Amp independent socket outlet using 2.5 sqmm single core wire (for phase, nuetral and earth) complete all as specified.
S&F, modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F , modular socket 6A, 3 pin combined, 2 module complete all as specified and directed.
S&F, modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F, modular socket 16A, 2/3 pin combined, 2 module complete all as specified and directed.
S&F, modular fan step type regulator, suitable for 1200mm/1400mm sweep ceiling fan, 2 module complete all as specified and directed.
S&F lamp holder (Angle/bracket) insulated body with back plate for batten fittings complete all as specified and directed.
S&F LED Adore Lamp 10W, B22 base 6500K CDL type complete all as directed by Engr-In-charge.
S & F decorative box type LED light fitting, 1 x 18 Watt, 230 V,C surfacce mounting white powder coated CRCA sheet steel housing with crescent light opening in a perforated metallic frame complete with 18 W LED tube rod complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed by Engr-in-charge.
Disconnecting carefully and taking down the existing ceiling fan of any size, and depositing to MES E/M store for safe custody complete all as directed by Engr-in-Charge
S&F ceiling fans 1200mm sweep energy efficient five star rated 230 volts with brushless direct current motor (BLDC) with blades, down rods, electronic regulator control type and accessories with brushless direct current motor (BLDC) including down rods and connecting up with 3 runs of suitable size single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors from ceiling rose to fan complete all as specified and as directed.
Supply and fixing LED energy efficient street light fitting 30 watt LED pressure die cast aluminium housing in heat resistant glass covered with IP-65 protection and including GI pipe bracket as required length and size with fixing accessories complete. Make : Crompton/Havells/Wipro
S&F, industrial socket 32A with top, 3 pin combined, complete all as specified and directed.
M&L for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 1 x 4 sqmm in concealed PVC conduit of 20mm complete all as specified and directed
S&F MCB DB, SPN 8 way, double door, concealed flush type with 200A rated busbar, 240 V complete all as specified and directed
Supply and fix MCB SPN 32A, 10 kA, C series, 230 Volts complete all as specified and directed
Supply and fix MCB SP 6-32A, 10 kA, C series, 230 Volts complete all as specified and directed
Taking down Main switch / DBs inluding MCBs of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
Taking down old unserviceable / worn out aluminium sub main of any type and size complete all as specified and directed.
S & F LED highbay 90 watt lumianaries a fine ventilation technology for better thermal management and its cutting edge LED technology with LEDs 90 watt and with flat white high transmission acrylic diffuser white/neutral white color temperature etc, prewired with all hanging arrangements of the fitting as per site requirement such as steel rope, hooks etc. complete all as directed by Engr-in-Charge.
Supply, laying, testing, connecting and commissioning underground cable LT 1100 volt grade heavy duty XLPE insulated armoured with aluminum stranded conductor complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands criping type cable lugs etc all as specified and directed of size 10 Sqmm 2 core Note-Excavation, earthwork, sand cushioning, GI pipe protection, cable cover shall be measured and paid separately complete all as specified and directed.
Supply, laying, testing, connecting and commissioning underground cable LT 1100 volt grade heavy duty XLPE insulated armoured with aluminum stranded conductor complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands criping type cable lugs etc all as specified and directed of size 50 Sqmm 3.5 core Note-Excavation, earthwork, sand cushioning, GI pipe protection, cable cover shall be measured and paid separately complete all as specified and directed.
Supply, installing, testing and commissioning factory made and tested (including CPRI test certified) LT feeder pillar box (KIOSK) compartment type, outdoor type, plateform mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars of rating 400 amps rating installed on porcelain insulator. The panel shall be dust and vermin proof. IP-65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with double door setter and locking arrangement (including provn of 65mm Godrej lock with two keys) internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size and comprising of the following :- (a) Incoming :- MCCB 4 pole 16 KA, 100 Amps capacity 415 V, 50 Hz, , AC supply, IS marked, complete with all standard accessories - 01 Nos (b) Outgoings :- (i) MCCB 3 pole 16 KA, 63 Amps capacity- 03 Nos (iii) Digital multimeter and indication lamp showing Amps, Volts, Hz (vi) Three CTs of ratio 400/5A class-1 burden 15VA- 01 Set (vii) Providing space for MCCB 3 pole - 01 No
S&F 32mm x 6mm galvanised iron strip as earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe complete all as specified.
Singh Engineer And Contractor
ALBA AC AND REF SERVICES
Shree Builders
Bhumi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .