Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹29.0 L+₹2.5 L (9.53%)Rejected-AOC FLAT NO 4 C GH 39 MANSA DEVI COMPLEX SECTOR 05 PANCHKULA 134 109 HRY | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-AOC Quoted L2 |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
1 Jul 2023, 6:00 pmClosed
GE AF Chandigarh
GE AF Chandigarh PIN-160003 C/o 56 APO
SPECIAL REPAIRS TO BUILDING NO. P-99 AT AF STATION KASAULI UNDER GE (AF) CHANDIGARH
2023_MES_600938_1
GE(AF)/CHD/T-17/2023-24
Open Tender
Civil Works
Item Rate
183 days
Kasauli
All as per NIT and Tender documents
10 documents required · 10 mandatory
₹500
GE AF Chandigarh
₹69,000
Yes
30 Aug 2023
3 Jun 2023
7 Jul 2023
3 Jun 2023
1 Jul 2023
17 Jun 2023
3 Jun 2023 - 9 Jun 2023
Amount
Taking down shutters of any description exc. 1 sqm but n. exc. 2 Sqm each and refixing in the same opening after repairs complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and out of defense land complete all as specified and directed.
M&L for Non skid joint free ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement to match the shade laid over and including 15mm thick screed be or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L glazed ceramic coloured/ printed tiles 450mm x 350mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed.
M&L for metal suspended ceiling system OREO GI laid in plain 600mm x 600mm x 0.5mm (tegular) edge tiles in global white colour to be laid on strong 24mm T-section flanges colour white having rotary stitching on the main runner with web height of 38mm comprising main runner spaced at 1200mm c/c securely fixed to the structural soffit at 1200mm maximum c/c and first/ last suspension system at the end of each main runner not more than 450mm from the adjacent wall, flush fitting 1200mm long cross tees interlocked between main runners at 600mm c/c to form 1200mm x 600mm mould, cut cross tees longer than 600mm having independent support; 600mm x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between 1200mm cross tees; perimeter trim to wall angles of size 3000mm x 19mm x 19mm secured to walls at 450mm (maximum) c/c, suspension system accessories consisting of HLC sleeve anchor fasteners of thread size 6.50mm x 25/5 with soffit cleat made of galvanised steel of size 27mm x 37mm x 1.60mm & level clip in dimensions of 85mm x 30mm x 0.80mm with 4mm GI wire complete all as specified & directed. Make: High steel, Armstrong & Dexune.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/ slabs/ blankets any thickness including cover fillets and snap grid complete all as specified and directed.
Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified as in rain water gutter complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L framed work as in doors or gates or rain water gutters etc. of angle or other section with gusset plates, rails, braces, etc. complete; drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F rolled mild steel sections as in posts, main and cross beams, hip and jack rafters; purlins, where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc. conforming to Fe-290 (Gde E-165) complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F 100mm PVC (SWR) bends any radius all as specified and directed.
S&F PVC (SWR) reducers all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position including separating, scraping and cleaning of reinforcement and removal of debris to a distance n. exc. 50m complete all as specified and directed.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges flat for rough finished surface complete all as specified and directed.
M&L mild steel TMT bars 10mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
M&L for RCC (1:1½:3) type A-1 using graded stone aggregate as chajja, fins, louvers, roof projection, beam and lintel after removing of loose concrete including preparation of surface by application of de-rusting chemical such as Dr fixit rust remover or equivalent and welding additional main bars/ distribution bars by inserting to adequate depth in beam by drilling, priming reinforcement bar old/ new with a coat of anti corrosive Nitozinc primer of M/s FOSROC complete all as specified and directed. Notes: 1. Quoted rate shall be deemed to include for necessary scaffolding etc. as required for single storey high buildings. 2. Reinforcement will be measured and paid separately. 3. Nitozinc primer will be paid separately.
M&L for RCC (1:1½:3) type A-1 using graded stone aggregate as chajja, fins, louvers, roof projection, beam and lintel after removing of loose concrete including preparation of surface by application of de-rusting chemical such as Dr fixit rust remover or equivalent and welding additional main bars/ distribution bars by inserting to adequate depth in beam by drilling, priming reinforcement bar old/ new with a coat of anti corrosive Nitozinc primer of M/s FOSROC complete all as specified and directed. Notes: 1. Quoted rate shall be deemed to include for necessary scaffolding etc. as required for triple storey high buildings. 2. Reinforcement will be measured and paid separately. 3. Nitozinc primer will be paid separately.
M&L for applying anti-corrosive primer, Nitozinc of M/s FOSROC or equivalent as approved by GE to old de-rusted reinforcement bars in chajjas complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on concrete surface as in chajja, ceiling etc. finished even and smooth without using extra cement including application of two coats of cement base paint complete all as specified and directed. Note: Quoted rate shall be deemed to include for necessary scaffolding etc. as required for triple storey high buildings.
Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed.
M&L for providing water proofing treatment to sunken portion of WCs, bathroom etc. comprising the following complete all as specified and directed:- (a) Applying neat cement slurry @ 1.3 Kg/ Sqm of surface including wire brushing, cleaning, washing and preparing floor & sides of walls. (b) 15mm thick plaster in cement mortar (1:3) mixed with integral water proofing compound on floor and wall and finishing the surface even and fair. (c) Applying first layer of cement slurry @ 0.488 Kg/ Sqm mixed with and including Acrylic based polymer modified cementations composite compound @ 0.253 Kg/ Sqm after the rendering has set and dried up. (d) Applying second layer of cement slurry @ 0.242 Kg/ Sqm mixed with Acrylic based polymer modified cementations composite compound @ 0.126 Kg/ Sqm after 4 hours of application of first layer of cement slurry. This layer will be allowed to air dry for 4 hours followed by water curing for 48 hrs. Note: Supply only water proofing compound shall be measured and paid separately.
M&L for PCC (1:5:10) type E-2 using brick aggregate as in sunken portion complete all as specified and directed.
Supply only integral water proofing compound
M&L for 25mm thick PCC (1:2:4) type B-0 using graded stone aggregate as in sub floor for laying floor tiles complete all as specified and directed.
S&F 40mm dia medium grade GI pipe as in spout for sunken floor; fixed as in wall with inside end fixed with wire netting and external bevelled edge at 45⁰ complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc. 15cm thickness (below or above ground level) and removing debris out of MoD land complete all as specified and directed.
M&L for 75mm thick plain cement concrete (1:3:6) type C-1 using graded stone aggregate as in plinth protection including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick, concrete stone surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick floating coat in cement mortar (1:4) finished even and smooth over and including 10mm thick backing coat in cement mortar (1:4) on brick or concrete surfaces complete all as specified and directed. Note: Supply only of WPC will be measured and paid separately.
Dismantling of CI soil, waste, vent or rain water pipes of any dia any pattern including all fittings all as specified and directed.
S&F 75mm bore cast iron sand cast soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed.
S&F 75mm bore cast iron sand cast soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls all as specified and directed.
S&F 100mm bore cast iron sand cast soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed.
S&F 100mm bore cast iron sand cast soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls all as specified and directed.
S&F 100mm branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches all as specified and directed.
S&F 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F 75mm bore CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches suitable for all as specified and directed.
S&F PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
Disconnecting of geyser carefully and re fixing the same including all necessary fittings complete all as specified and directed.
Supply and fixing/ hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top) 500 litre capacity ‘double layered’, hoisted and fixed in position including inlet, outlet and drain pipe with plug including dismantling existing tank complete all as specified and directed.
Taking up or down existing steel water tubing and connections 15mm bore for re-fixing or removing from site to store for reuse or credit including taking down standard fittings complete all as specified and directed.
Supply, laying, jointing and testing 15mm bore galvanised iron tube medium grade with all fittings and fixed complete to walls and ceiling or laid in floor including clamps for fixing to wall complete all as specified and directed.
M&L for re-fixing galvanised water tubing 15mm bore with new fittings in new or old position, fixed complete to walls and ceiling or laid in floor including clamps for fixing to wall complete all as specified and directed.
Taking up or down existing steel water tubing and connections 20mm bore for re-fixing or removing from site to store for reuse or credit including taking down standard fittings complete all as specified and directed.
Supply, laying, jointing and testing 20mm bore galvanised iron tube medium grade with all fittings and fixed complete to walls and ceiling or laid in floor including clamps for fixing to wall complete all as specified and directed.
M&L for re-fixing galvanised water tubing 20mm bore with new fittings in new or old position, fixed complete to walls and ceiling or laid in floor including clamps for fixing to wall complete all as specified and directed.
S&F in repairs vitreous china wash hand basin (flat back or angle back type) of size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand, PTMT waste coupling, waste pipe complete all as specified and directed. MAKE: HINDWARE/ CERA/ FRORENTINE OF JAQUAR
S&F brass chromium plated fancy type pillar tap for wash hand basin screwed for iron pipe 15mm bore complete all as specified and directed.
S&F in repairs brass chromium plated fancy type pillar tap for wash hand basin screwed for iron pipe 15mm bore complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) with plastic water closed seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging devices including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc. complete all as specified and directed.
S&F in repairs chromium plated steel jet pressure unit alongwith suitable size and of appropriate length PVC pressure pipe, fixed to EWC/ IWC complete all as specified and directed.
Taking down and re-fixing after necessary cleaning, bleaching, washing & changing minor parts as washers etc., 10 litre capacity low level flushing cistern complete including PVC bend/ flush pipe, making all connection complete all as specified and directed.
S&F in repair fancy type stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions 15mm dia and fixed complete all as specified and directed.
S&F in repairs 15mm dia bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
Taking down and re-fixing 15mm dia bib tap complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutter from the frame) of any description along with fittings exc. 1.50 Sqm but n. exc. 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutter from the frame) of any description along with fittings n. exc. 1.50 Sqm each complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge mitred cut at two corners and joined by inserting two No. 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall by drilling and providing 100mm long MS screws with PVC fasteners complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rain, lock & bottom rail on either side & as gap insert for top rail & bottom rail, Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frame at site as per specification complete all as specified and directed.
S&F pressed steel frame for doors of size 125mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed.
M&L 40mm thick flush door shutter, solid core construction with block board core and plywood face panels, commercial type on both side complete all as specified and directed.
M&L for cutting holes in brick/ stone walls built in cement mortar or cement lime mortar for inserting hold fasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate for the required depth of embedded portion of holdfasts or lugs measured from the face of jamb into the wall exc. half brick but n. exc. one brick complete all as specified and directed.
S&F steel window box type, primer coated, comprising ERW Hollow `P’ section of size 60mm x 25mm of 1.25mm wall thickness frame, single rebated, skeleton shutter (suitable for wire gauge), made of ERW section 50mm x 20mm of 1mm wall thickness, and operated leaf side hung, without glazing bars but including Flat iron 12mm x 3mm for securing wire mesh, dove tailed or welded/ riveted welded to frame of shutter and openable shutter prepared to receive wire gauge, complete including cutting holes four Nos for each window and making good disturbed portion in PCC (1:3:6) type C-1 including following fittings welded to frame/ shutter complete all as specified and directed:-(a) hold fast 150mm long out of 25mm x 6mm flat iron made to shape - 04 Nos each window (02 Nos on each side).(b) Handle of `Z’ section 20mm x 25mm, 100mm long- 01 No (each leaf).(c) MS tower bolt 150mm long- 02 Nos (each leaf). (d) `Z’ section 20mm x 25mm, 100mm long stopper- 01 No (each leaf). (e) Cleat 55mm long of hollow square section 15mm x 15mm of 24 gauge wall thickness, welded to hinge of 55mm size- 01 No (per leaf). (f) MS box type hinges of 75mm size- 03 Nos (per leaf). (g) Fabrication and fixing compete as per approval & drawing.
Notes: (i) Wire gauge and painting shall be measured and paid separately under respective items. (ii) Design shall be approved from the Engineer-in-Charge as per Drg No CEAF/STD-185/2012 sheet 1/2 to 2/2 before fabrication and bulk order to the manufacturer.
S&F steel window box type, primer coated, comprising ERW Hollow `P’ section of size 60mm x 25mm of 1.25mm wall thickness CRCA sheet frame, single rebated, skeleton shutter (suitable for glazing), made of ERW section 50mm x 20mm of 1mm wall thickness and operated leaf side hung, with two Nos glazing/ sash bars of `T’ section 20mm x 3mm welded to frame of shutter, prepared to receive glass complete with one shop coat of red oxide zinc chromate primer including cutting holes four Nos for each window and making good disturbed portion in PCC (1:3:6) type C-1 including following fittings welded to frame/ shutter complete all as specified and directed:- (a) Hold fast 150mm long out of 25mm x 6mm flat iron made to shape- 04 Nos each window (02 Nos on each side). (b) Handle of `Z’ section 20mm x 25mm, 100mm long- 01 No (each leaf). (c) MS tower bolt 150mm long- 02 Nos (each leaf). (d) `Z’ section 20mm x 25mm, 100mm long stopper- 01 No (each leaf). (e) Cleat 55mm long of hollow square section 15mm x 15mm of 24 gauge wall thickness, welded to hinge of 55mm size- 01 No (per leaf). (f) MS box type hinges of 75mm size - 03 Nos (per leaf). (g) Fabrication and fixing compete as per approval and drawing.
Notes:- (i) Glazing and painting shall be measured and paid separately under respective items. (ii) Design shall be approved from the Engineer-in-Charge before fabrication and bulk order to the manufacturer(s) as per Drg No CEAF/STD-184 of 2012, sheet 1/3 to 3/3.
S&F factory made box type steel section ventilator with box type section double leaf shutter for glazing and wire gauze with pintel hinges, 01 No 150mm long mild steel tower bolt, steel handle to each shutter (steel handle dovetailed or welded), and with one shop coat of red oxide zinc chromate primer complete all as specified and shown in drawing duly fitted with all fittings, welded to frame/ shutter including cutting holes for hold fasts & making good in PCC 1:3:6 Type C-1 complete all as specified and directed. Notes: (i) Wire mesh & glazing shall be measured and paid separately. (ii) Design shall be approved from the Engineer-in-Charge before fabrication and bulk order to the manufacturer(s) as per Drg No CEAF/STD-186/2012 sheet 1/1.
S&F stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed to wood/ steel frames with stainless steel wire staples complete all as specified and directed.
S&F 100mm size stainless steel butt hinges, medium weight, cold rolled complete with stainless steel screw all as specified as directed.
S&F in repairs 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified.
S&F 125mm extruded aluminium alloy handles, fabricated type, anodized complete all as specified and directed.
S&F floor door stopper, 140mm overall length of cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified and directed.
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F in repairs stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed to wood/ steel frames with stainless steel wire staples complete all as specified and directed.
M&L for preparing new or previously un-treated wooden and wood based surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden or wood based surface over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel surface of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of oil bond distemper over a coat of primer complete all as specified & directed.
M&L for complete removal of existing treatment with electric operated blade, washing with water and bleaching powder solution from wall surface, stopping the surface & levelling/ edging the disturbed surface/ edges using cement based wall care putty to obtain smooth finish and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls including cornices and applying two coats of white wash complete all as specified and directed.
M&L for applying three coats of white wash on ceilings including preparation of newly plastered surfaces complete all as specified and directed.
M&L for providing and applying plaster of Paris putty of 2mm thick over plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for preparation of new surface and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489: 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified and directed. Notes: (i) Pattern of camouflage if any shall be as approved by GE (if any). (ii) Rate quoted by contractor shall be deemed to include the cost of use and waste of necessary ladder, wooden platform etc. as may be required to execute work at any height upto 8.00m.
S&F 5.5mm thick figured glass, pin head type and glazing with oil putty wooden beads as directed in squares n. exc. 0.50 Sqm in each pane complete all as specified and directed.
Demolition of brick masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facings, dressed stone work including removal of rubbish outside MD land complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Excavating in trenches in hard/ dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation or for shafts, wells, cesspit, manholes etc. n. exc. 10sqm on plan and getting out complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer n. exc. 25cm complete all as specified.
Removal of excavated soil to distance n. exc. 50 metre and depositing where directed at a level n. exc. 1.5metre above the starting pointing complete all as specified and as directed.
Demolition of SGSW drain pipe 100mm bore with PCC bedding and haunching /hunching and taking out of trenches if required with fittings and removing the entire material out of defence land complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using graded stone aggregate as in bed to 150mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for supply, lay & jointing 150mm bore reinforced concrete pipes, class NP-2 with collars laid in trenches and jointed in cement mortar complete all as specified and directed.
S&F door seal with PVC body & fitted with rubber seal complete all as specified and directed.
S&F in repairs fibre glass reinforced translucent corrugated sheeting 2mm thick in thickness with two corrugation side lap fixed with ‘L’ type or ‘J’ type hooks bolts complete all as specified and directed.
S&F in repair 10 litre capacity PVC valveless, symphonic action type low level flushing cistern white including inlet, ball valve, float, handle including brackets AND flush pipe complete all specified and directed.
M&L for second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F pre-laminated particle board 18 to 19mm thick, interior grade, pre-laminated on both sides with decorative choice lamination on one face & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
S&F extruded aluminium alloy handle, fabricated type anodised of 75mm long all as specified and as directed.
S&F in repairs 25mm dia Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. with brackets etc complete all as specified and as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. complete all as specified and directed. Note: Taking down of fittings such as switches, ceiling roses, pendants, regulators, sockets etc. shall be measured and paid for separately.
Taking down carefully submain wiring including service connection complete with PVC conduit/ casing caping & GI wire any size and making good disturbed surfaces complete all as specified and directed.
M&L for point wiring surface/ concealed complete with single core multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour code 1100 volts grade drawn through in and including medium grade non metallic rigid PVC conduit 19mm dia or higher with all standard fittings such as Tee junction, bends, including new sunken terminal boxes duly epoxy painted for mounting modular switch/ sockets etc. and including 1.5 Sqmm multi stranded copper conductor PVC insulated unshearthed FRLS colour code cable 1100 volts grade for earth continuity for one light/ ceiling fan /exhaust fan, bell point (through regulator), controlled by one switch complete all as specified and directed:-
One light pint controlled by one way switch.
One fan/ exhaust fan point controlled by one way switch.
One three pin 6 Amp switch socket cum on same board.
One light pint controlled by two No. two way switches.
One three pin 6 amp socket outlet multipurpose on independent board.
All as per item No. 111.00 above but with 4.0 sqmm cable insulated for 3 pin 16 amp multipurpose outlet including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board complete.
S&F in repairs switch piano, flush type, single pole, one way, 5 Amps, 230 volts complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, two way, 5 Amps, 230 volts complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, one way, 15 Amps, 230 volts complete all as specified and directed.
S&F in repairs bell push, flush type, single pole, 5 Amps, AC, 230 volts complete all as specified and directed.
S&F in repairs call bell of multi music type, single pole, AC, 230 volts complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3 pin 5 Amps, 230 volts complete all as specified and directed.
S&F in repairs socket outlet, flush type, multipurpose, multi pin, 2 in 1, 3 pin 5 Amps & 15 Amp, 230 volts complete all as specified and directed.
S&F in repairs ceiling rose PVC/ polycarbonate isolated body 65 x 50mm with 2 to 3 terminals 230 Volts, AC Single phase complete all as specified and directed.
Supply, fixing, connecting and testing MCB SPN, 6 to 40 Amps, 240 volts of rupturing capacity 10kA, 'C' curve type complete all as specified and as directed.
Supply, fix, connecting and testing MCB isolator SPN, 40 Amps all as specified and as directed.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 42, SPN, 12 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 100 Amps, 415 volts breaking capacity, 35kA with adjustable thermal and fixed magnetic setting conforming to IS: 13947-II including taking down the existing one complete all as specified and directed.
S&F in repairs LED Decorative box type batten fitting 1 x 18 to 20 watt prewired suitable for retrofit LED tube rod duly prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sqmm from ceiling rose to connector block complete all as specified and directed.
S&F in repairs LED tube rod 20 watt (retrofit tube rod) energy saving, recess/ surface mounted luminaire suitable for fixing in 1 x 18 to 20 22 watt fitting complete all as specified and directed.
S&F in repairs LED light fitting, 9 to 20 watt, wall/ ceiling mounted type complete with all accessories pre-wired including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repairs lamp holder insulated body with back plate for batten fittings/ angle holder as required complete all as specified and directed.
Supply and fix 9 watt LED bulb all as specified and as directed.
Supply and fix in repairs LED channel 10 watt with suitable accessories duly pre-wired including connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repairs LED bulk head luminaire 1 x 10 watt IP65 and heat resistant complete all as specified and as directed.
M&L earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mm x 6 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1, RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old u/s earthing materials complete all as specified and directed.
Notes :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 50cm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance shall be less than 3Ohm. In case test results are not found below 3Ohm, complete earthing will be re-done without any extra cost to Govt.
M&L for submain wiring with 2 run of FRLS PVC insulated & unsheathed multi stranded copper conductor of nominal cross section area 6.0 sqm alongwith one run of FRLS PVC insulated & unsheathed copper conducter of nominal cross sectional area 4.0 sqm as earth continuity conductor drawn through and including PVC conduit concealed as required size confirming to IS: 9537 (Part-3), including accessories fixed on wall/ ceiling all as directed including taking down existing submain wiring and making good of disturbed surface complete all as specified and directed. Note: Two runs of 6.0 sqmm multi-stranded cable and one run of 4.0 sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring with 2 run of FRLS PVC insulated & unsheathed multi stranded copper conductor of nominal cross section area 4.0 sqm alongwith one run of FRLS PVC insulated & unsheathed copper conducter of nominal cross sectional area 2.5 sqm as earth continuity conductor drawn through and including PVC conduit concealed as required size confirming to IS: 9537 (Part-3), including accessories fixed on wall/ ceiling all as directed including taking down existing submain wiring and making good of disturbed surface complete all as specified and directed. Note: Two runs of 4.0 sqmm multi-stranded cable and one run of 2.5 sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
S&F in repairs stepped flush type electronic ceiling fan regulator 450 watt, 250 volts all as specified and directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 230 Volts including taking down old one complete all as specified and directed.
M&L taking down ceiling fan after dis-connecting the electric connection and keeping in safe custody and hanging the same after repairs to building including making connection from ceiling rose to connector of fan with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Babu Ram Sud and Sons
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .