Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹3.4 L+₹661 (0.20%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹3.9 L+₹54,873.60 (16.3%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹4.1 L+₹72,900.80 (21.6%)Accepted-Finance | L4 | Accepted-Finance OK | |
| 5 | L5₹4.5 L+₹1.1 L (32.1%)Accepted-Finance | L5 | Accepted-Finance OK |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
15 Jul 2024, 12:30 pmClosed
EE
CHANDRAWAL WATER WORKS
Renovation of electric work for laboratory, their offices and allied areas at Chandrawal WW-II
2024_DJB_259157_1
NIT NO. 02 (2024-25)
Open Tender
Miscellaneous Works
Works
30 days
CHANDRAWAL WATER WORKS
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJBEMD A/c No-50448339804 THROUGH SUBPAISA GATEWAY
₹9,000
7 Aug 2024
8 Jul 2024
15 Jul 2024
8 Jul 2024
15 Jul 2024
8 Jul 2024
8 Jul 2024 - 15 Jul 2024
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B ( DSR 2022 code 1.10.2 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required ( DJB approved make ) a) 1 x 1.5 sqmm
b) 2 x 2.5 sqmm
c) 2 x 4 sqmm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.. ( DJB approved make ) a) 5/6 amps switch
b) 3 pin 5/6 amp socket outlet
c) 15/16 amps switch
d) 6 pin 15/16 amp socket outlet
Supplying and fixing the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as required. a) 8 module ( 125 mm x 125 mm )
b) 6 module ( 200mm x 75 mm )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. 2 x 10 + 1 x 6 sqmm earth wire. ( DSR 2022 code 1.14.5 )
Supplying and fixing of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including ,painting etc. ( DSR 2022 code 1.57 )
Supplying and fixing of modular blanking plate on the existing modular plate and switch box excluding modular plate as required. ( DSR 2022 code 1.26 )
Supplying and fixing of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc ( DSR 2022 code 1.32 )
Supplying of wall fan of 400mm size at site ( crompton /Havells or equivalent ) ( make : USHA/crompon/Havells and DJB approved make ) ( SOR 20.4.1 )
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. ( DSR 2022 code 1.25 )
Supplying and fixing of following sizes of medium class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20mm
Higher Wattage Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. ( Philips/havells/Polycab and DJB approved make )
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less Direct Currnet ( BLDC) Motor, class of insulation: B, 3 nos blades, 30 cm long down rod, 2 nos canopies, shackles kit, safety rope, copper winidng , Power factor, not less than 0.9 service value ( CM/M/W) minimum 6.00 , Air delivery minimum 219 Cum/min 350 RPM ( tolerance as per IS: 374-2019) , THD less than 10% remote of electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C ( max) insulation resistance more than 2 mega ohm, suitable for 230 volt 50 HZ single phase AC supply , earthing etc complete as reqd
Supplying of LED decorative diffuser 2x2 panel light i/c making connection etc as reqd. at site. ( Philips/havells/Polycab and DJB approved make ) ( SOR 2022 19.9.3 )
Supplying and fixing of brass batten/angle holder including connections etc as required. ( DSR 2022- 1.34)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door ( L&T/Siemens/Hagger and DJB approved make ) ( DSR 2022 code 2.3.3)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole ( L&T/Siemens/Hagger and DJB approved make ) ( DSR 2022 code 2.10.1 )
Supplying and fixing following 63 amp, double pole, 240 volts, DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( L&T/Siemens/Hagger and DJB approved make ) ( DSR 2022 code 2.12.2 )
Providing of 12" ( 300mm ) exhaust fan with all accessories and making connection etc as reqd. at site ( Havells/ CG / Orient/ Usha/Almonard/DJB approved )
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep.
Supplying and fixing of fan rod 3' for the ceiling fan including making connection etc as reqd.
Loading, unloading, cartage and transportation charges for the above pole upto the side i/c charges of heavy labour etc. as per site requirement.
Supply of double box type fitting complete with all accessories i/c making connection etc as reqd. TMC 502 1X T-LED 22W P3242 i/c having 2 nos steller 20 watt LED tube light in the existing fitting etc as reqd. ( Philips /havells /Polycab and DJB approved make )
Supplying and fixing of LED bulb 12 watt i/c making connection etc as reqd. at site ( Philips/Polycab/Havells and DJB approved make )
Supplying of 24" Almonard wall fan 600 mm Air circulating fan alloey steellow noise motor with all accessories and making connection etc as reqd. at site ( Crompton/Havlls/ DJB approved )
Installation, testing and commissioning of LED fitting of all type complete with all accessories directly on ceiling wall including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and earthing etc as reqd. at site. ( DSR 2022 code 1.41)
Installation, testing and commissioning of 48" ceiling fan including wiring the down rods standard length single core copper conductor cable etc as reqd. at site. ( DSR 2022 code 1.44)
Testing and commission of complete work in the presence of Engineer-in-charge with full satisfaction.
S S P ENTERPRISES
GOGIA BROTHERS
EVERSHINE ENTERPRISES
JAI DURGA ENGINEERS AND CONTRACORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .