Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Admitted |
| 2 | Accepted-Technical | Accepted-Technical Admitted |
| 3 | Accepted-Technical | Accepted-Technical Admitted |
| 4 | Accepted-Technical THANGZANG ROAD BEAMATHANG BAROO BAROO KARGIL KARGIL JAMMU KASHMIR 194105 | KARGIL | LADAKH | 194105 | Accepted-Technical Admitted |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
21 Mar 2026, 4:00 pmClosed
Executive Engineer ED Kargil
Kargil Drass
Annual Maintenance/repair of HT AND LT lines and Sub-Stations labor component only in Zanskar Sections of district Kargil 2026-27.
2026_PDNRE_18537_1
E- NIT 01 OF 2026-27
Open Tender
Electrical Works
EOI
7 days
Baroo Kargil
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Executive Engineer Electric Distribution Division
₹1 L
24 Mar 2026
4 Mar 2026
23 Mar 2026
7 Mar 2026
21 Mar 2026
16 Mar 2026
Loading of Poles
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Unloading of pole at road side and its carriage upto 25 Mtr.
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Dragging/ Manual carriage of pole to site of work for every subsequent 50 Mtr.
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Loading of line material.
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Unloading and manual carriage of line material upto 25 Mtr.
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Carriage of line material manually to site of work for every additional 50 Mtr or part thereof.
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Erection of pole ( with plantation depth equal ot 1/6th of the pole length) for HT/LT including pit excavation in all soil as per REC Standards ammended upto date.
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
Providing & laying Cement bottoming of Poles
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
Laying , Stringing of A.C.S.R Conductor.
A.C.S.R conductor up to 30 mm² (Squirrel / Weasel )
A.C.S.R conductor 50 mm² (Rabbit)
A.C.S.R conductor 100mm² (Dog)
Re-stringing/Tightening of snapped /loose conductor
A.C.S.R conductor up to 30mm² (Squirrel / Weasel )
A.C.S.R conductor 50mm² ( Rabbit)
A.C.S.R conductor 100mm² (Dog)
Dismantling of overheated/Damaged/ worn out Conductor and Bundling.
A.C.S.R conductor up to 50mm² (Squirrel / Weasel)
A.C.S.R conductor 50mm² (Rabbit)
A.C.S.R conductor 100mm² (Dog)
Erection of guy rod complete
LT Line
HT Line
Dismantling of D.Wood/ broken/under size pole in HT/LT Line.
Fixing of Jumper sets
HT Line
LT Line
Laying and stringing of overhead LT/AB Insulated cable
Upto 16 mm² - 35mm²
Item Code 79
Laying of single core 3P 4W LT U/G Cable
Earthing of ST pole of all length
Pipe Earthing
Spiral Earthing
Survey, Route alignment
HT Line
LT Line
Branch Cutting
Guard Netting (Single Span) (Avg Span of 50mtr)
Installation/ Erection of equipments
L.A Set
D.O Set
Link Set
G.O Set
H.G Set
Iron work such as fabrication of steel work.
Loading of 11/0.4 KV Distribution transformer
Upto and including 63 KVA
From 100 KVA upto and including 200 KVA
Above 200 KVA upto and including 630 KVA
Unloading of 11/0.4 KV Distribution transformer
Upto and including 63 KVA
From 100 KVA upto and including 200 KVA
Above 200 KVA upto and including 630 KVA
Dragging of 11/0.4 KV Distribution transformer for every subsequent 50 Mtr.
1Upto and including 63 KVA
100 KVA upto and including 200 KVA
200 KVA upto and including 630 KVA
Mounting of Transformer on X-arm bed
Upto and including 63KVA
Above 63 KVA upto and including 200 KVA
Above 200 KVA upto and including 630 KVA
Mounting of Transformer on plateform .
From 630 KVA Upto 1.5MVA
Erection/ Installation of LT Cable circuit complete job.
Upto and including 63 KVA
Above 63 KVA upto and including 200 KVA
Above 200 KVA upto and including 630 KVA
Errection/Installation of HV and Earth connections.
Upto and including 63 KVA
Above 63 KVA upto and including 630 KVA
Erection/ Installation of MCCB complete job
Fixing of service line.
Fixing of Consumer Service line
Installation of Single Phase Energy Meter
Installation of Three Phase Energy Meter/ Prodigy Meter
Laying and Stringing of 11 KV AB cable
Item Code 166
Installation and dismantling of HT/LT AB cable jointing kit.
Installation of CT/PT Unit along with Meter (Complete job)
Fixing of danger Plates (HT/LT)
Fixing of Anti Climbing Device
Painting of MS cross arms, braces and clamp with one basecoat and two coats of aluminum Paint.
Painting of Steel Tubular poles including cross arm & clamp etc. with one basecoat and two coats of aluminum paint.
8 Mtr long
9 Mtr long
Erection of MS cross arm
up to 3 feet long
above 3 feet to 6 feet long
above 6 feet to 12 feet long
Erection of MS V-cross arm with F-top
Fixing of Braces
Fixing of HT Pin insulator Poymer/porcalein
Fixing of LT Pin/Shackle insulator Poymer/porcalein
Fixing of Disc insulator Poymer/porcalein
Fixing of Top clamp for pin insulator (HT)/ PG clamp
Fixing of U/D clamp
Transportation of Distribution transformers from Divisional Store Kargil to site or vice-versa.
Per Day Charges of Skilled labour (Electrician)
Per Day Charges of Unskilled labour
Topping up of Transformer Oil in various capacity transformers
P/F of timer for highmast lights
Item Code 226
P/F OF CONTACTOR FOR HIGHMAST LIGHT
Replacement of 150 W LED
Providing and Laying/ Fixing of items Purely on rent basis.
P/F of 4mm.sq PVC wire
P/F of 2.5mm.sq PVC wire
P/F of 1.5mm.sq PVC wire
P/F of 1mm.sq PVC wire
P/F of 12 Watt LED Bulb
P/F of Holder for blub
P/F of Bed Switch
P/F of Insulation Tape Roll
P/F of MCB 16Amp
P/F of Nail Concrete
P/F of Saddle 6mm
P/F of 63Amp Changeover switch
P/F of 32 Amp. DP
P/F of 16Amp S.S. Combine
P/F of 16Amp. Socket
P/F of 10 Watt LED Flood light
P/F of 80 Watt LED Flood light
P/F of 50 Watt LED Flood light
P/F of Decoration Lamp hanging type (Tri-Colour)
P/F of 10mm.sq. Al Cable 2-Core
Tri-Colour LED decoration light (Rope/Strip type)
P/F of 6 Pin Extension card
P/F of 16mm.sq. Al Cable 2-Core
Item Code 252
P/F of 63Amp Changeover switch
P/F of 32 Amp. DP
P/F of 16Amp S.S. Combine
P/F of 16Amp. Socket
P/F of 10 Watt LED Flood light
P/F of 80 Watt LED Flood light
P/F of 50 Watt LED Flood light
P/F of Decoration Lamp hanging type (Tri-Colour)
P/F of 10mm.sq. Al Cable 2-Core
Tri-Colour LED decoration light (Rope/Strip type)
P/F of 6 Pin Extension card
P/F of 16mm.sq. Al Cable 2-Core
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
sbd2026.pdf
Tender Documents • 0.26 MB
BOQ_44486.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .