Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | ₹15.7 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹16.2 L+₹46,880 (2.99%)Rejected-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹16.2 L+₹46,880 (2.99%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹16.5 L+₹75,915 (4.84%)Rejected-AOC 264 2 GALI NO 7 RAM NAGAR ROORKEE DIST HARIDWAR UK | ₹16.5 L+₹75,915 (4.84%) | L3 | Rejected-AOC REJECTED |
| 4 | L4₹16.9 L+₹1.2 L (7.40%)Rejected-AOC | ₹16.9 L+₹1.2 L (7.40%) | L4 | Rejected-AOC REJECTED |
| 5 | L5₹20.8 L+₹5.1 L (32.6%)Rejected-AOC | ₹20.8 L+₹5.1 L (32.6%) | L5 | Rejected-AOC REJECTED |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Jan 2020, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
REPAIRS MAINT AND REPLACEMENT OF LT PANNEL FEEDER PILLAR BOXES LT SWITCH GEARS AND OTHER CONNECTED WORKS IN POCKET 4 TO 6 UNDER GE ROORKEE
2019_MES_308649_1
8391/890/E8
Open Tender
Civil Works
Item Rate
180 days
ROORKEE CANTT
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹50,000
Yes
25 Jun 2020
23 Dec 2019
21 Jan 2020
23 Dec 2019
20 Jan 2020
6 Jan 2020
Amount
M&L for Repair/overhauling to outdoor type LT panel/feeder pillar box of any size/ make including insulating to bus bars with shrinkable PVC sleeves of colours red, yellow, blue and black replacement of worn out / us cables as per existing gauge, door rubber beedings, nuts, bolts washers, hinges, thimbles, lugs, cable glands & welding work etc making functional to the system and testing on load complete all as specified and as directed at site by Engr-in-charge.Note:- Spares required for replacement will be measured & paid separately under respective items.
All as per Srl item No. 1.00 above but indoor type LT Panel/ feeder box.
M&L for painting to indoor/outdoor type LT panel/FP box of size not more than 1.8 m height internally as well as external surfaces complete with two coats of synthetic enameled paint of approved quality including preparation of old surfaces, writing of bus bars & outgoing /incoming locations with white paint gridth upto 2” (50mm) complete all as specified & as directed at site by Engr-in-charge.
Supply and fixing in replacement on panel including making in coming /out going connections :-
a) MCCB TP pole 250 Amp, 36/35kA, 415 Volts Make : Legrand/Havells/C&S/Indo Asian
b) MCCB rating 200 Amp, 36kA 3/4 pole Make : Legrand/Havells/C&S/Indo Asian
c) MCCB rating 160 Amp, 36 kA, 3/4 Pole Make : Legrand/Havells/C&S/Indo Asian
c) MCCB rating 125 Amp, 25KA, 3/4 pole Make : Legrand/Havells/C&S/Indo Asian
d) MCCB rating 100 Amp, 25 kA 3/4 pole Make : Legrand/Havells/C&S/Indo Asian
e) MCCB rating 320 Amp, 36 kA, 4 Pole Make : Legrand/Havells/C&S/Indo Asian
f) MCCB rating 63 Amp, 16 kA, 3/4 pole Make : Legrand/Havells/C&S/Indo Asian
g) Digital Voltmeter of rating 0-500 V , size 96mm square type (Make: AE/MICO/L&T
h) Digital Ammeter of rating upto 0-600 Amp, size 96mm square type (Make : AE/MICO/L&T).
j) LED Indicator assy with colour red/ yellow/ blue.
k) Copper Current transformer (CT) ratio 5/100 Amp (Set of 3 Nos).
k) Copper Current transformer (CT) ratio 5/200 Amp (Set of 3 Nos).
m) MCCB Four pole 250 Amp, 36kA, 415 Volts Make : Legrand/Havells/C&S/Indo Asian
n) MCCB Four pole 400 Amp, 36/35kA, 415 Volts . Make : Legrand/Havells/C&S/Indo Asian
S&F in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including a coat of red oxide primer one underand & one finishing coat complete all as specified and directed.
S & F in replacement of stay assembly comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm long, 16mm dia , MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 65 x 90mm clearance of hole 16 mm & other accessories complete all as per SSR Part-1, Plate No.1. complete all as specified and directed. Note : MS clamps, excavation earth work & PCC work will be measured & paid separately.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 50 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
S&F testing commissioning cable jointing kit Heat shrinkable end terminal out door type, suitable for HT 11 KV cable 120 Sqmm to 185 Sqmm 3 core 11 KV (Make : Denson/ M Seal).
S&F testing commissioning cable jointing kit Heat shrinkable end terminal out door type, suitable for HT 11 KV cable 70 Sqmm to 95 Sqmm 3 core 11 KV (Make : Denson/ M Seal).
-do-all as per item No. 12 above but indoor jointing kit for 11 KV cable 120 Sqmm to 185 Sqmm 3 core.
-do-all as per item No. 12 above but indoor jointing kit for 11 KV cable 70 Sqmm to 95 Sqmm 3 core.
Supply, laying & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area as given below:- Make :Havells/Polycab/Finolex
(a) 3.5 core 120sq.mm.
(b) 3.5 core 95 sq.mm.
(c) 3.5 core 50 sq.mm.
(d) 4 core 25 sq.mm.
(e) 4 core 16 sq.mm.
(f) 4 core 10 sq.mm.
(g) 2 core 10 sq.mm.
Excavation in trenches/post holes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed.
Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. ( Note: Thickness after punning shall be measured for payment )
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.
M&L for PCC 1 : 4 : 8 type D-2 using 40 mm graded stone aggregate as in foundtion, filling and mass concrete complete all as specified.
M&L for replacement of unserviceable sheet metal enclosure power distribution board for independent mounting DRX100 MCCB enclosure Make : Legrand cat part No . 607906, including MCCB 63 Amp four pole, 415 volt,10kA Make Legrand and including necessary connection complete all as specified and directed by Engr-in-Charge. Make: : Legrand cat part No.027029 or equivalent in Simens/Schenider
M&L for replacement of unserviceable sheet metal enclosure power TPN , 4 way, DPX3 160 MCCB enclosure distribution board, complete all as specified and directed by Engr-in-Charge. Make : Legrand cat part No . 607913 or equivalent in Simens/Schenider
S & F in replacement of u/s MCB SP 40 Amp, 415 Volt,'c' curve including necessary connection complete all as specified and directed by Engr-in-charge. Make : Legrand / Simens/Schenider
M & L in repair sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 4 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through in existing surface/recessed steel/PVC conduit or PVC flexible sleevs connecting with copper lugs to common earth terminals complete all as specified and directed. Note :-(i) Two run of copper cable and one run of earth wire including conduit /PVC Casing/caping shall be measured as one length.
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of size 900 x 900cm depth not less than 4.0 metre below normal ground level with top edge of the earth plate at a depth not less than 3.4 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers (each layer of 0.23 cu. m) upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Supply testing jointing and commissioning of Heat shrinkable jointing kit end termination 3.5 core x 25-50 sqmm LT XLPE 1100 Volt cable complete all as spd and directed . Make- Raychem/ Denson/ Mseal
Supply testing jointing and commissioning of Heat shrinkable jointing kit end termination 3.5 core x 70-150sqmm LT XLPE 1100 Volt cable complete all as spd and directed . Make- Raychem/ Denson/ Mseal
Supply testing jointing and commissioning of Heat shrinkable jointing kit end termination 3.5 core x 185-300 sqmm LT XLPE 1100 Volt cable complete all as spd and directed . Make- Raychem/ Denson/ Mseal
M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed by Engr-in-charge.
M&L for High Tension cable fault checking by high tension cable fault testing machine by disconnecting the HT cable end termination including insulation testing complete of faulty cable.complete all as specified and directed by Engr-in-Charge.
Dismentaling of old steel tubular pole LT/HT after excavation of PCC and disconecting of cross arm and insulators,and shifting it to new location as required on site including all ACSR conductor any size/ cross arm/insulators connections including PCC work with ratio 1:3:6 and coping and testing of overhead line complete all as specified and directeded.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed.Note : Sand shall be mearsured and paid separately in connected items.
M&L for removing all connections, bindings etc of ACSR/AAC conductor on existing LT poles & stretching of ACSR/AAC conductor upto required sag of any size and cross section of conductor and stretching of GI wire on existing pole including making necessary connection & binding with binding wire including cutting of tree branches from both sides upto the stress on each side complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of old painted surcaces using polish paper painted exposed surfaces silver aluminium paint two coats to steel tubular pole of 11mtr including crossarms.Bracket etc complete with writing Nos of pole with white paint on black 3"dia circle all as directed specified complete.
Material and labour for preparation of old painted surcaces using polish paper painted exposed surfaces silver aluminium paint two coats to steel tubular LT pole upto 9.0mtr including crossarms.Bracket etc complete with writing Nos of pole with white paint on black 3"dia circle all as directed specified complete.
M&L in repalcement of aluminium conductor, steel reinforced off sizes including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed by Engr-in-charge.
Supply & fix Junction box of size 317mm X 265mm X 160 mm) wiith 32 Amps MCB TPN(Make Legrand cat part No.408680 ) with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp (Make Legrand cat part No.4085 87) capacity and PVC cable 2.5 sqmm Aluminium wire upto 7.5 mtr length for connection of security light from junction box to light fitting and includes making suitable hole on existing pole to take out connections to fitting if required at site.Make : Sintex/Naptune
M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia with -4 Nos & flat washer (3mm thick) 01 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.
Supply and spreading graded coarse aggregate of size 40 mm at electrical outdoor installation yard 11KV Substations/ Near DP structures etc including levelling of uneven surface, removing vegetation, grass etc complete all as specified and diected by Engr-in-charge.
Supply & fix in replacement of capacitor , and capacitor should be box type heavy duty, characterized by dielectric with non toxic, biodegradable synthetic oil, having 10 micron pp film ,inrush current protection up to 2 in, dielectric losses less than 0.2 w/kvar, 450 v, 50 hz,having life more than one lakh hours , under ideal condition of the system of capacity 25 kvar complete all as specified and as directed
Supply & fix in replacement of capacitor , and capacitor should be box type heavy duty ,characterized by dielectric with non toxic, biodegradable synthetic oil, having 10 micron pp film ,inrush current protection up to 2 in, dielectric losses less than 0.2 w/kvar,450 v, 50Hz, having life more than one lakh hours , under ideal condition of the system of capacity 10 kvar complete all as specified and as directed
S&F in repair power Contactor 3 Phase with AC coil 32 Amp, CN432 T01 type make Havells Cat part No. IHPAA032401 including making all connections complete all as specified.
Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mm height, 65 mm dia for 1100 Volt grade complete all as specified. Make BHEL/Pactil/Rastriya/Jaipuria.
M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. Make Pactil/BHEL/Rastriya//Jaipuria.
KAPOOR ELECTRICALS
KISHORE CHAND DINESH CHAND
Balraj and Co
Panwar Construction Co.
GLIBS CONSTRUCTION
AGARWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .