Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | ₹4.6 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | SMEC Automation Pvt Ltd L2 | Mohandas M L3 | SHIJIN B G L1 |
|---|---|---|---|---|---|---|
| 1.00SUPPLY OF ELECTROMAGNETIC FLOW METERS | ||||||
| 1.00 | OD186520/2024-2025: Supplying and installation of electro magnetic flow meter confirming to protection level of IP 68 for flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard rubber/ neoprene all confirming to drinking water standards. The flow meter is to be installed in 350 mm dia DI pipe (work includes supply, installation, anchor blocks and all connected works ). The flow meter should be coupled with HART with data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions. Provision shall be there for integrating the flow meter reading with the existing SCADA system at PH Circle, Thiruvananthapuram. | 1 | no | 3,95,000 ₹3,95,000 | 4,03,040.5 ₹4,03,040.5 | 3,89,601 ₹3,89,601 Lowest |
| 2.00Construction of Chamber for the Flow meter | ||||||
| 2.00 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 10.94 | cum | 300 ₹3,281.4 | 263.35 ₹2,880.52 Lowest | 263.35 ₹2,880.52 Lowest |
| 2.00 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources) | 0.44 | cum | 9,700 ₹4,277.7 Lowest | 9,977.73 ₹4,400.18 | 9,977.73 ₹4,400.18 |
| 2.00 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 12.16 | sqm | 400 ₹4,864 | 394.74 ₹4,800.04 Lowest | 394.74 ₹4,800.04 Lowest |
| 2.00 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 150 | kilogram | 139 ₹20,850 | 114.92 ₹17,238 Lowest | 114.92 ₹17,238 Lowest |
| 2.00 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 2.15 | cum | 10,200 ₹21,930 Lowest | 10,721.86 ₹23,052 | 10,721.86 ₹23,052 |
| 2.01 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 27.05 | sqm | 307 ₹8,304.35 Lowest | 377.98 ₹10,224.36 | 377.98 ₹10,224.36 |
| 2.01 | 100.98.1008:Engaging Coolie. | 4 | no | 1,000 ₹4,000 Lowest | 1,106.22 ₹4,424.88 | 1,106.22 ₹4,424.88 |
Tender Value
Refer Docs
EMD Value
₹11,816
Closing Date
19 May 2026, 3:00 pmClosed
AEE
AEE, WW North Sub Division, Kowdiar
Non Plan Urban Ugglomeration 2021 2022 Supplying and instalation of electro mechanical flow meter in out let line of Kudapanakunnu Pump house under W W section Peroorkada General Civil Work
2026_KWA_850104_1
WRD/KWA-CE(SR)/TR/31170/2024
Open Tender
Civil Works - Water Works
Item Rate
90 days
WW North Sub Division, Kowdiar
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,045
Yes
₹11,816
Yes
18 Jul 2026
12 May 2026
20 May 2026
12 May 2026
19 May 2026
12 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUPPLY OF ELECTROMAGNETIC FLOW METERS | |||||
| 1.001 | OD186520/2024-2025: Supplying and installation of electro magnetic flow meter confirming to protection level of IP 68 for flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard rubber/ neoprene all confirming to drinking water standards. The flow meter is to be installed in 350 mm dia DI pipe (work includes supply, installation, anchor blocks and all connected works ). The flow meter should be coupled with HART with data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions. Provision shall be there for integrating the flow meter reading with the existing SCADA system at PH Circle, Thiruvananthapuram. | - | no | - | - |
| 2Construction of Chamber for the Flow meter | |||||
| 2.001 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | - | cum | - | - |
| 2.002 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources) | - | cum | - | - |
| 2.003 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | - | sqm | - | - |
| 2.004 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | - | kilogram | - | - |
| 2.005 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 1 | cum | - | - |
| 2.006 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | - | sqm | - | - |
| 2.007 | 100.98.1008:Engaging Coolie. | - | no | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Tendernotice_2.pdf
PDF • 0.04 MB
BOQ_1436511.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .