Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹73.7 LAccepted-AOC 550 HIWARI LAYOUT WARDHAMAN NAGAR NAGPUR MAHARASHTRA 440008 | NAGPUR | MAHARASHTRA | 440008 | L-1 | Accepted-AOC AS PER CWC-II DECISION HELD ON 11/10/2023 | |
| 2 | L-2₹87.2 L+₹13.5 L (18.3%)Rejected-AOC | L-2 | Rejected-AOC AS PER CWC-II DECISION HELD ON 11/10/2023 | |
| 3 | L-3₹97.7 L+₹24.0 L (32.5%)Rejected-AOC | L-3 | Rejected-AOC AS PER CWC-II DECISION HELD ON 11/10/2023 | |
| 4 | Rejected-Technical | - | Rejected-Technical AS PER CWC I DECISION HELD ON 09/09/2023 |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
28 Jul 2023, 2:30 pmClosed
GENERAL MANAGER
O.F BHANDARA
Construction of building for Maturation process of wet paste inside factory at O.F. Bhandara.
2023_MIL_161056_1
No.EO/F/51/ND2203/BF
Open Tender
Civil Works - Buildings
Item Rate
365 days
O.F.BHANDARA
As per Tender Documents.
7 documents required · 7 mandatory
₹0
₹1.9 L
Yes
11 Oct 2023
14 Jul 2023
31 Jul 2023
14 Jul 2023
28 Jul 2023
14 Jul 2023
Amount
M & L for grubbing up tree trunk exc. 30 cm and n exc. 100 cm girth including cutting of trunk portion protruding over ground , digging out roots ,filling holes and levelling off ground , stacking of serviceable material an removing of unserviceabe material to a distance n exc.50 m and ciearing site, complete all as specified.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified
M & L for removing excavated material (rocks), exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified.
M & L for hardcore of broken stone or boulders exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface, complete all as specified
M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified
M & L for PCC 1:4:8 Type D2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC 1:2:4, type B0 using 20mm graded aggregate for foundations, including rafts, footing, foundation beams, plinth beam bases for column etc.basement slab, under reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge..
M & L for RCC 1:2:4, type B1 using 20mm graded aggregate for Columns, pillars, piers, posts and struts complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC 1:2:4, type B1 using 20mm graded aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, work in rough finished flat surfaces of concrete complete all as specified and as directed by the E-I-C
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) work in rough finished flat surfaces of concrete complete all as specified and as directed by the E-I-C
M & L for mild steel deformed or twisted bars of 8 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including M.S. wire (annealed) not less than 0.9mm
M & L for brickwork with subclass "B" bricks ,in straight curved on plan exc 6m mean radius ,built in CM 1:6 complete all as specified and as directed by the engineer -in-charge.
M & L for rendering 25mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces & is to be finished even and smooth complete all as specified and as directed by the Engineer-in-Charge
Finishing surface of concrete road, pavement by brooming.
Forming 20mm thick Expansion joints 100mm filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’
M&L for bitumen mastic antistatic flooring 25 mm thick with matt finish in floor confirming to IS - 8374 (1977 ), IS - 1195 ( 2002 ) and IS - 1196 (1978 reafferiming 2001), with application of bitumen primer and 32 gauge brass strip 25 mm wide laid @ 300 mm C/C both way and fixed with brass screw and grits including testing of floor for electric resistivity in between 50x10 ³ ohms 2X10 ⁶ ohms etc. all as specified and directed by EIC.
M & L for 25 mm thick Bitumen mastic to vertical surface of drains/walls in two coats with application bitumen primer and making rounded at joint of floor- wall including wired o.90 mm dia, 16mm mesh fixed with tinned tickets or wire staples at 150 mm C/C all as specified
S & F 1st class hardwood chowkats and frames Plain, solid, straight, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed by the Engineer-in-Charge
S & F 40mm thick, Ist class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged); fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge
S&F for 35mm thick Ist class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
M & L for rough cast wired glass 6.4 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
S & F butt hinges 100mm size, type B-12, extruded brass, with mild steel hinge pin, bright polished complete all as specified and as directed by the Engineer-in-Charge
S & F butt hinges 75mm size, type B-12, extruded brass, with mild steel hinge pin, bright polished complete all as specified and as directed by the Engineer-in-Charge.
S & F 200mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 150mm extruded brass handles, fabricated type polished complete all as specified and as directed by the Engineer-in-Charge.
S & F 300mm long brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and as directed by the Engineer-in-Charge
M&L Preparation of new surfaces and painting wooden surfaces of any description, not otherwise described over 10 cm width or girth with one coat of pink primer and two coats of synthetic enamel paint.
M&L Preparation of new or previously untreated surfaces and painting Bricks, stone, concrete, asbestos cement or plaster surfaces of any description over 10 cm width or girth not otherwise described with one coat of Priming paints plaster coat and two coats of synthetic enamel paint.
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Supply and Laying in trench/ fixing of cable on wall using saddles and making connection, brass glands, copper lugs etc. XLPE insulated heavy duty , PVC inner and outer sheathed electric cables with Aluminium Conductor, Size 3.5 C x 185 sq.mm ,1100 Volt grade, GI strip/wire armoured and with cable size, make and length marking on every 1 meter of cable conforming to IS:7098 (patr-I) .Make-Gloster/ Polycab/ Uniflex/Havells or equivalent.
Ditto, but of size 4 C X 10 Sq.mm
Supply & Fixing for Wiring for circuit /submain wiring along with earthwire with the following sizes of FR PVC insulated copper conductor (multistrand), make : Polycab/Finolex/V-Guard /HPL/L&T or equivalent, single core cable in surface/recessed (concealed) as required in Steel Conduit. Size 2X2.5 sq.mm +1X1.5 sq.mm earth wire (Suitable metal union and bend should be provided). Steel Conduit should be FLP type, heavy duty & pressure tested.
Supply & Fixing for Wiring for circuit /submain wiring along with earthwire with the following sizes of FR PVC insulated copper conductor (multistrand), make : Polycab/Finolex/V-Guard /HPL/L&T or equivalent , single core cable in surface/recessed (concealed) as required in Steel Conduit. Size 2X4.0 sq.mm +1X2.5 sq.mm earth wire. (Suitable metal union and bend should be provided) .Steel Conduit should be FLP type, heavy duty & pressure tested.
M & L for earthing complete with using copper earth plate electrode 60×60cm ×3.15mm thick ,buried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts,nuts,ckeck nuts and washers of galvanised iron or steel including upto 7.5 mtr length/test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indicated including testing on completion and as directed by EIC
M & L for earthing complete with galvanised steel earth plate electrode 60x60 cm x6.3 mm thick ,buried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised strip 32x6 mm as earthing lead by means of bolts,nuts,ckeck nuts and washers of galvanised iron or steel including upto 7.5 mtr length/test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indicated including testing on completion and as directed by EIC
Excavation in hard dense soil 1.5 mtr wide & 2.5 mtr deep for earth pits
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 mm G.I Strip with insulator and fixing screw.
M & L for aluminium strip 25 x 3.15mm with saddle,epoxy insulator(1 meter apace), fixing screw ,GI nut bolts,etc. for roof conductors and down conductors above ground ..
Supply & fixing of GI Pipe medium grade 25 mm Dia with GI nuts & bolts ,2 nos of clamp ,funnel etc as watering pipe in earth pits and as directed by EIC.
Supply & Fixing of supports/ clamps of MS angle 50 x 50 x 6 mm size and back/top plates (size: 50 x 50 x 6 mm) fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of oil paints.
Supply and fixing of GI pipe medium grade 80mm dia under road/culvert etc.
Ditto, But medium grade 40mm dia
M & L for pre-cast cement concrete blocks set in cement mortor 1:4 ,type B1 1:2:4 (20 mm grade arrregate)masonry with solid blocks , exc. 10 cm.
M & L for Air termination, single pointed aluminium rod 12 mm dia. and 300 mm long with GI Nuts Bolts.
Material and labour for precast cement concrete hollow block ( Set in Cement mortar 1:6) ,size 50 X 50 X 80 cm( outer dimension), 10 cm width (type 1:3:6 using 16 mm graded aggregate ) as per IS 383.
Demolition/Dismantelling cement concrete in building pavements, gantries up to 15cms thick
M&L for making concrete ,20 mm grade typeC-1 , 1:3:6. on above dismnateled portion.
Back filling of excavated soil spreading, leveling & well raming in layers.
M&L for reinforced precast concrete cable covers ,class LV, Type 1, flat, size 250X150X40 mm.
Supply and Laying GI wire size 4mm dia runing in cable trench.
S&F of Flameproof switches ,rotary type with termination box LM 6, 16A, double pole,250 V,duly certified by CIMFR, Dhanbad . Make: CG/Sudhir Switchgear/ Shyamm or any reputed make.
S & F of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+ earth
S&F of Switch piano, flush type, single pole, one way 5 Amp, Anchor / Cona/Havells or Equivalent make.
Ditto, but 15 Amp
S&F of socket outlet 2 in 1, 3 Pin, 5 amps flush type, anchor / cona or equal make.
S&F of socket outlet 2 in 1, 3 pin , 5 and 15 amps flush type, anchor / cona or equal make.
M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 .
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
M & L for Ceiling rose, 3 phase/PVC/ polycarbonate , isolated body.
M & L for Boxes junctions, plastic, round, four terminals.
M & L Cast iron pressed steel terminal boxes 60mm deep size 250mmx300mm rectangular for mounting, switches, sockets, fan regulator etc with 3mm thick pastic laminared sheet cover not exceeding the size 250x300mm.
Supply & Fixing only Teak Wood / summica board in closed recessed 250mmX300mmX4 mm.
Supply & laying /fixing on wall through G.I saddling of cable electric PVC / XLPE insulated , PVC sheathed , copper conductor, size 4 core* 4 sq. mm, armoured 1100 volt grade as per IS. Make – polycab /gloster and equivalent
S & F of Light fitting bulk head industrial type totally enclosed suitable for 9-14 watt LED lamp, B-22 cap with clear glass & 19 mm incoming gland provision for cable entry make: bajaj/ surya or equivalent.
Supply & Fixing of Flameproof LED Well glass ,30 to 40 Watt , duly certified by CIMFR, Dhanbad . Make: CG/Sudhir Switchgear/ Shyamm or any reputed make.
Supply & Fixing of Flameproof junction box, 16 Amp rating, 4Way connector,100mm dia duly certified by CIMFR,Dhanbad.Make: CG / Sudhir Switchgear / Shyamm or any reputed make.
Supply & Fixing of Flameproof Gland ,size 19mm , Double compresson type duly certified by CIMFR,Dhanbad.
Supply & Fixing of Flameproof Gland ,size 25mm , Double compresson type duly certified by CIMFR,Dhanbad.
Supply & Fixing of Flameproof MCB DB , including , 4 Pole ,32 Amp-1 Nos rotary swiitch for incomer , Outgoing- 1) Rotary switch with MCB SP (C Curv) 6/10 Amps - 6 Nos. 2) Rotary switch with MCB SP(C Curv) 16 Amps - 3 Nos. duly certified by CIMFR,Dhanbad. Make of MCB-ABB/SEIMENS/SCHNIDER ELECTRIC/L&T/GE or equivalent.
Supply and Laying in trench/ fixing of cable on wall using saddles & Steel Conduit of 19 mm size and making connection, brass glands, copper lugs etc. XLPE insulated heavy duty , PVC inner and outer sheathed electric cables with Copper Conductor, Size 3C x 1.5 sq.mm ,1100 Volt grade, GI strip/wire armoured and with cable size, make and length marking on every 1 meter of cable conforming to IS:7098 (patr-I) .Make-Gloster/ Polycab/ Uniflex/Havells or equivalent.
M & L for Temperature controller digital 0-200 degree celsius RTD input PT 100 ohms (metal body) size 96 x 96 deep operating on 24 V AC/DC with Box / housing arrangement and fixing on wall with nut, bolt, washer etc.
M & L for 9 mtr long steel tubulers swaged poles complete with cast iron based plate, final taper plug, bolts,nuts & screws as per specified type 410 SP -31 including Aluminium painting, digging and refilling with concrete for grouting and as directed by EIC.
Supply & fixing outdoor type distribution box made out of CRCA sheet metal 2 mm thick on pole 415 V consisting of 1 nos. of 63 A connector and one no. of 6A MCB SPN with bottom cable plate drilled, danger sticker 415 V and fixed with rubber gourments.The DB cover will have lockable arrangements. The DB should be of size 300X300X150 mm, 2 Nos. of GI clamp of 25X5 mm dully painted to be provided to fixed the DB on pole.
M & L for LED Street light fitting, 60W, 100 lum/W, IP66, color temp 5700K, life 50000 burning hours as per LM79 & LM80 applicable for LEDs (Make Cree/Seoul/Philips/ Osram/ Nischia or equivalent) and inbuilt 5 KV surge protection, (100V-300V)AC, 50/60Hz, PF>0.95, Epoxy powder coated pressure die cast aluminium housing with waterproof gasket and including GI pipe bracket made out of 40mm bore medium grade 1.5 Mtr. long fixed with two sets of clamps of MS flat iron 25x5mm, nuts bolts and washer and painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by EIC. Make Bajaj product code 169941 BRLEP 60W LED V2 or equivelent make of CG/Wipro/Philips.
M & L for Brass cable gland nickel plated of size 25 mm inner dia.
M & L for Sunmica wooden board 250 mm x 300 mm.
M & L GI flexible conduit size 19mm.
M & L GI flexible conduit size 25mm
S & F of FRP/ DMC conical insulator M10*60 HT, rated volt 440V, test volt 2KV for 1 min, size base diameter 60mm, height not less than 60 mm from base, top face diameter not less than 40 mm, effective threaded length not less than 16 to 19 mm with brass / stainless steel nut, bolt & washer.(fixing of insulator as directed by EIC)
Supply & Fixing of Paperless recorder, make endress & hauser, model:RSG30-B1B1AEA Ecograph TRSG30, 3 digital inputs, 6 universal inputs, power supply: 100-230 VAC, multichannel display mode, 4 relays, memory medium, with pc software package readwin 2000, with Box / housing arrangement and fixing on wall with nut, bolt, washer etc.
S & F of Signal wire for RTD, Teflon coated 6 wire and overall SS covering.
S & F of industrial Smoke detector sensor,for detection of smoke resulting from a fire, operating voltage: 17-28V DC, with alarm indication, relative humidity:0-95%, operating temp:- 20 to 60 Deg C, protection IP43, with connection cable 2 core, art no.907541, type: omx 95, make: Minimax or equivalent with Flame proof Box / housing arrangement and fixing on wall with nut, bolt, washer etc.
S & F Aluminium checkered plate size 600x600x8mm for static charge dissipator.
M&L of LT PCC cum MCC Panel indoor type consisting of the following: MCCB 400 Amp,4P, 50 KA as incomer = 1 No ; Outgoing feeders consisting of folowing: 1) MCCB (4P), 250 Amp,36KA = 1 No; 2) Fuseless Starter 5.5 KW Motor (10 to 16 Amps) = 1Nos; 3) Fuseless Starter 2.2 KW Motor (4 to 6.3 Amps) =2 Nos; 4) MCB 32 Amps 4P-3 no; 5) MCB 16 Amp 2P=6 Nos; 6) MCB 10 Amps single pole-4 no; as per technical specification attached Annexure'A'
Writing letters or figures by stenciling, 8 CM height with white enamel paint. (Block,Roman,Italic or Indian ) not exceeding 30 cm height.
Rajesh Gurao
M/s. H.B.CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .