Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | ₹29.7 L | L1 | Accepted-AOC For Being L1 |
| 2 | L2₹29.8 L+₹7,730 (0.26%)Rejected-AOC | ₹29.8 L+₹7,730 (0.26%) | L2 | Rejected-AOC Not Being L1 |
| 3 | L3₹30.7 L+₹97,320 (3.28%)Rejected-AOC CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | ₹30.7 L+₹97,320 (3.28%) | L3 | Rejected-AOC Not Being L1 |
| 4 | L4₹31.1 L+₹1.4 L (4.73%)Rejected-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | ₹31.1 L+₹1.4 L (4.73%) | L4 | Rejected-AOC Not Being L1 |
| 5 | L5₹31.4 L+₹1.7 L (5.86%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹31.4 L+₹1.7 L (5.86%) | L5 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Sreema Enterprises L1 | M/S AARJAY ASSOCIATES L2 | Classic Builders L3 | SHAIJAL T M L5 | Kuriako Mathai and company L4 | WELTRONENGINEERINGSERVICES L6 | Green Ray Enterprises L7 | ELAN ENGINEERS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed. | 125 | Cubic metre | 250 ₹31,250 Lowest | 400 ₹50,000 | 250 ₹31,250 Lowest | 256 ₹32,000 | 254 ₹31,750 | 262 ₹32,750 | 253 ₹31,625 | 265 ₹33,125 |
| 2.00 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed. | 98 | Cubic metre | 120 ₹11,760 Lowest | 150 ₹14,700 | 120 ₹11,760 Lowest | 123 ₹12,054 | 122 ₹11,956 | 150 ₹14,700 | 121 ₹11,858 | 160 ₹15,680 |
| 3.00 | Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified. | 27 | Cubic Metre | 130 ₹3,510 Lowest | 300 ₹8,100 | 140 ₹3,780 | 144 ₹3,888 | 142 ₹3,834 | 150 ₹4,050 | 141 ₹3,807 | 160 ₹4,320 |
| 4.00 | M&L for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed.
NOTE: Punned thickness shall be measured and paid. | 30 | Cubic Metre | 800 ₹24,000 Lowest | 2,000 ₹60,000 | 800 ₹24,000 Lowest | 1,025 ₹30,750 | 1,015 ₹30,450 | 890 ₹26,700 | 1,010 ₹30,300 | 900 ₹27,000 |
| 5.00 | Supply and lay unreinforced precast cable cover size 250X150X40 mm LV1 complete all as specified and as directed. | 2,200 | Each | 30 ₹66,000 Lowest | 45 ₹99,000 | 30 ₹66,000 Lowest | 31 ₹68,200 | 30 ₹66,000 Lowest | 36 ₹79,200 | 30 ₹66,000 Lowest | 41 ₹90,200 |
| 6.00 | Material and Labour for cutting the existing bituminous road / PCC Hard Standing upto 75cm in depth, 60cm in width and getting out excavated materials making good the damaged portion after laying of pipes by returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate all as specified and directed. | 12 | Running Metre | 1,000 ₹12,000 | 1,000 ₹12,000 | 1,000 ₹12,000 | 1,025 ₹12,300 | 1,015 ₹12,180 | 900 ₹10,800 | 1,010 ₹12,120 | 880 ₹10,560 Lowest |
| 7.00 | Supply and fix HT, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed grade, 3 core cross sectional area 185 sq. mm including taking out complete all as specified and directed. | 80 | Running Metre | 2,000 ₹1,60,000 | 1,600 ₹1,28,000 Lowest | 2,000 ₹1,60,000 | 2,050 ₹1,64,000 | 2,030 ₹1,62,400 | 2,200 ₹1,76,000 | 2,200 ₹1,76,000 | 2,100.99 ₹1,68,079.2 |
| 8.00 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 150 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. | 150 | Running Metre | 1,500 ₹2,25,000 | 750 ₹1,12,500 Lowest | 1,500 ₹2,25,000 | 1,538 ₹2,30,700 | 1,523 ₹2,28,450 | 1,800 ₹2,70,000 | 1,600 ₹2,40,000 | 1,700.89 ₹2,55,133.5 |
| 9.00 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. | 110 | Running Metre | 550 ₹60,500 | 400 ₹44,000 Lowest | 500 ₹55,000 | 513 ₹56,430 | 508 ₹55,880 | 650 ₹71,500 | 505 ₹55,550 | 550 ₹60,500 |
| 10.00 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 25 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. | 100 | Running Metre | 250 ₹25,000 | 220 ₹22,000 Lowest | 250 ₹25,000 | 256 ₹25,600 | 254 ₹25,400 | 360 ₹36,000 | 253 ₹25,300 | 380 ₹38,000 |
Tender Value
₹30.0 L
EMD Value
₹59,980
Closing Date
4 Nov 2025, 6:00 pmClosed
Ajeet Singh GE
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
DAY TO DAY MAINTENANCE REPAIRS TO EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIC SUPPLY, DG SETS , LIGHTING PROTECTION SYSTEM ,SECURITY STREET LIGHTS, CHLORINATOR AT COAST GUARD STATION VIZHINJAM, TRIVANDRUM UNDER GE (I) (CG) KOCHI
2025_MES_735042_1
8271/E8
Open Tender
Civil Works
Item Rate
365 days
Vizhinjam TRIVANDRUM
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I)(CG) Kochi
₹59,980
Yes
20 Apr 2026
14 Oct 2025
11 Nov 2025
14 Oct 2025
4 Nov 2025
28 Oct 2025
14 Oct 2025 - 21 Oct 2025
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed.
Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified.
M&L for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply and lay unreinforced precast cable cover size 250X150X40 mm LV1 complete all as specified and as directed.
Material and Labour for cutting the existing bituminous road / PCC Hard Standing upto 75cm in depth, 60cm in width and getting out excavated materials making good the damaged portion after laying of pipes by returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate all as specified and directed.
Supply and fix HT, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed grade, 3 core cross sectional area 185 sq. mm including taking out complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 150 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 25 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 16 Sqmm 4 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 10 Sqmm 2 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
Supply & Fix 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Supply & Fix in replacement of MCCB 63 Amps,4 pole, 415 Volt adjustable type with breaking capacity 10 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 100 Amps,4 pole, 415 Volt adjustable type with breaking capacity 25 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 125 Amps,4 pole, 415 Volt adjustable type with breaking capacity 25 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed.
Supply & Fix in replacement of MCCB 160 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 200 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 250 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply & Fix in replacement of MCCB 400 Amps,4 pole, 415 Volt adjustable type with breaking capacity 50 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
Supply and Fix in repairs drop out explusion fuse assembly with fuse carrier, triple pole for 11KV,current rating 100A outdoor type having two nos post insulator mounted on MS channel for each pole completed all as specified and directed.
Supply and fix in repair aluminium strip 25mmx3mm complete with saddles epoxy base and fixing screws for fitting the strip all as specified and directed.
Supply and fix in repair for earth contunity conductor of size 32x6mm GI strip all as specified and directed.
Supply and fix in repairs GOD Triple pole mechanically operated,mounted on insulator and steel frame wiht operating mechnism worked from ground level for current rating up to 200 Ams 11KV complete all as specified and directed.
Supply and fix in repairs lightining arrester high tension,expulsion type,transmission class,discharge capacity 65 Kilo Amps suitable for 11000V supply complete with all fitting suitable discharge capacity including necessary fixing arrangements made out of MS angle/flats,nuts and bolts etc complete all as specified and directed.
Material and labour for General maintenance /repair of 200 KVA transformers installed at ICGS Vizhinjam Sub Stations, including disconnecting the HT/LT cables, earth strips etc. from the transformer, draining the complete oil for removing sludge from the tank and removing the top cover, conservator, expulsion tank etc for detecting the leakage and repairing by welding, replacing all the gaskets & neoprene washers for leakage arresting, the HT /LT bushings if required, refill the oil, top up to required level without any extra cost, reassembling the transformer and testing etc complete all as specified and as directed.
Dehydration / filtration of transformer oils of transformer/switch gears to achive die-electric strength not less than 40kv for 1 miniute at 4mm gap as per relevent IS using portable filteration plant including testing of oil for die electric strength before and after filtration complete all as specified and directed. Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electricity for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
Supply and topping up new transformer oil into conservator tank/body tank of transformer using portable filtration plant and directed. Note:- (i) The transformer oil for topping up shall be with di electric strength more than 60kv for 1 miniute at 4mm gap. (ii) Oil shall be supplied at site in sealed barrel.
Taking down existing street light fittings fitted at any type of pole and Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete including connection twin core copper wire drawn through rigid PVC pipe not less than 20 mm dia from junction box to light fitting complete all as specified and directed. Note :-1. Rate of the LED light fitting includes LED light fitting, conncection twin core copper wire of suitable size, rigid PVC pipe not less than 20 mm dia and all accessories required to fit the light at any type of pole. 2. GI bracket is not included in the quotated rate.
Taking down existing street light fittings fitted at any type of pole and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete including connection twin core copper wire drawn through rigid PVC pipe not less than 20 mm dia from junction box to light fitting complete all as specified and directed. Note :-1. Rate of the LED light fitting includes LED light fitting, conncection twin core copper wire of suitable size, rigid PVC pipe not less than 20 mm dia and all accessories required to fit the light at any type of pole. 2. GI bracket is not included in the quotated rate.
Supply and fix in repair LED flood light fitting 200W/210W energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65/66, 10KV SPD, more than 100lm/watt flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting complete all as specified and as directed. Make: Model no. JETAADORNFLS120WLED757SSYMTOTG of Havells or equivalent in Crompton Greaves/Philips.
Taking down existing unsv terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 No 4 way connector 415 Volt, 63 Amp, made out of polycorbanate or bakelite and 1 No MCB of 6 AMP with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed.
Material and labour for preparation of old surface, cleaning the surface of the Steel pole (LT) 11 Mtr long in pole structures above the ground level incl coping area and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and derected by engir-in charge
M&L for repairs to LT/HT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt complete and painting with two coat of synthetic enamel paint of approved color internally and externally all as specified and as directed by Engineer-in-Charge
Supply and fixing post top lantern LED type 40 watt 230 watts volts AC outdoor type with decorative post top for 360 deegree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete Make: LPTO-40-CDL-M of Crompton Greaves/ Havells/Philips.
Supply and fix LED bollard light with pole 10 watt, 230 volt with aluminium body pressure die cast powder coated housing with PC diffuser IP-65 protection with inbuilt LED chip and driver, accessories prewired and fixing accessories complete all as specified and directed. Make: 824.075L10H.NHG of Jaquar or equivalent in Crompton Greaves/ Havells/Philips.
Material and labour for General servicing of UPS of capacity 10 KW , opening the outer cover, checking of all the printed circuits, mother board etc. cleaning all parts from dust and mosture by applying suitable gel/ cleaning solution, complete in all respect, soldering, replacement of battery leads/clamp/copper cable/ any other minor parts and testing complete up to the satisfaction of Engr-in-Charge. Note : (i) The cost of labour and consumables required for replacement of parts shall deem to include in the unit rate quoted by the contractor. (ii) The job has to be carried out in each four months and one complete checking will be treated as one Job.
Taking out unserrviceable earthing completely and providing Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connected to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth lead etc., complete.
Matereial and labour for rectifying leakage of GI/PP-R (Polypropylene random copolymer) pipe line of 20mm bore laid in floors/walls/roofs or in trunches including excavation in mud (not exc 6.1m x 0.7m x 0.7m) and making arrangement for dewatering by using electric /diesel pump /manual additional labour, for taking out old jointing fitting and S&F new one jointing fitting such as union socket, nipple,union,elbow and reducers complete all as directed
Matereial and labour for rectifying leakage of GI/PP-R (Polypropylene random copolymer) pipe line of 25mm bore laid in floors/walls/roofs or in trunches including excavation in mud (not exc 6.1m x 0.7m x 0.7m) and making arrangement for dewatering by using electric /diesel pump /manual additional labour, for taking out old jointing fitting and S&F new one jointing fitting such as union socket, nipple,union,elbow and reducers complete all as directed
Matereial and labour for rectifying leakage of GI/PP-R (Polypropylene random copolymer) pipe line of 40mm bore laid in floors/walls/roofs or in trunches including excavation in mud (not exc 6.1m x 0.7m x 0.7m) and making arrangement for dewatering by using electric /diesel pump /manual additional labour, for taking out old jointing fitting and S&F new one jointing fitting such as union socket, nipple,union,elbow and reducers complete all as directed
Matereial and labour for rectifying leakage of GI/PP-R (Polypropylene random copolymer) pipe line of 50mm bore laid in floors/walls/roofs or in trunches including excavation in mud (not exc 6.1m x 0.7m x 0.7m) and making arrangement for dewatering by using electric /diesel pump /manual additional labour, for taking out old jointing fitting and S&F new one jointing fitting such as union, socket, nipple,union,elbow and reducers complete all as directed
Taking down old unserviceable GI Pipe of 25 mm Dia capacities from wall/floor/ ground and taking for credit complete all as specified and directed.
Taking down old unserviceable GI Pipe of 40mm Dia capacities from wall/floor/ ground and taking for credit complete all as specified and directed.
Supply, fixing, laying & testing galvanised iron water tubing of 25 mm dia capacities, medium grade, ISI marked with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches/floor complete all as specified and directed:-
Supply, fixing, laying & testing galvanised iron water tubing of 40 mm dia capacities, medium grade, ISI marked with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches/floor complete all as specified and directed:-
Taking up/ down old PP-R tubing connection of 25 mm bore including clearing (from trenches) complete as directed :-
Taking up/ down old PP-R tubing connection of 50 mm bore including clearing (from trenches) complete as directed :-
Supplying and laying 25mm 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or infloors etc complete all as specified and directed.
Supplying and laying 50mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or infloors etc complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 40 mm bore complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 50 mm bore complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
Supply and fix in repairs CI Foot Valve, of 50 mm dia flanged / Screwed with GM working parts as per IS - 4038 with nuts bolts and gaskets etc…, complete all as specified and directed
Supply and fix in repairs CI Foot Valve, of 80 mm dia flanged / Screwed with GM working parts as per IS - 4038 with nuts bolts and gaskets etc…, complete all as specified and directed
Supply and fixing in repairs CI sluice valve both end flanged, gun metal spindle, iron wheel head including jointing, size of Sluice Valve Class PN 1.6 , 80 mm dia approved make complete all as specified and directed.
Supply & Fixing Non Return Sluice Valve 80 mm dia with flanged ends cast iron body, brass spindle, hand wheel, ISI mark including necessary rubber gasket, nuts, bolts washer etc all as specified and directed.
Dismantling, Cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 5.0 HP complete all as specified and directed.
Material and labour for servicing of pump sets including replacement of Ball bearing, mechanical seal and greasing etc for the pump set capacity 5 HP complete all as specified and directed.
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 20mm bore complete all as specified and as directed.
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 25mm bore complete all as specified and as directed.
Material and Labour for cleaning underground sump of 50000 Ltrs capacity by draining/ pumping out complete water from sump, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the sump, flushing out , washing of inner surface using lime and bleaching powder and clean water with the help of pump or drain out as required, applying a coat of white wash for all surfaces of the UG sump from inside, painting and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 500 Ltrs. complete all as directed. Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 750 Ltrs. complete all as directed. Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleaned yearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 1000 Ltrs. complete all as directed. Note: Tank shall be cleaned yearly as directed by Engineer-in-Charge.
Taking down existing unserviceable water tank after disconnecting water supply line and supply and fix new Rotational moulded polyethylene water storage tanks having capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
Taking down existing unserviceable water tank after disconnecting water supply line and supply and fix new Rotational moulded polyethylene water storage tanks having capacity 1000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
Material and Labour for cleaning of static water tank of 50000 Litre capacity by draining/pumping out complete water from the tank, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the tank, flushing out with bleaching powder, washing of inner surface using lime and clean water with the help of pump or drain out as required, applying a coat of white wash to all concrete surfaces of the tank from inside, painting of all metal parts and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
Dismantling, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 7.5 HP complete all as specified and directed.
Dismantling, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc for three phase, 230 volts motors of capacity 1 HP complete all as specified and directed.
Material and Labour for general servicing of Electrical Driven main pump of 7.5 HP capacity including replacement of Ball bearing, mechanical seal, cleaning, greasing, checking alignments, meggaring, with and including replacing gland, packing, capacitors, terminal blocks etc complete all as specified and as directed.
Material and Labour for general servicing of Electrical Driven main pump of 1.0 HP capacity including replacement of Ball bearing, mechanical seal, cleaning, greasing, checking alignments, meggaring, with and including replacing gland, packing, capacitors, terminal blocks etc complete all as specified and as directed.
Dismanlting of damaged portion of valve pit chamber wall and Material and labour for Brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius and built in CM 1:4 complete all as specified and as directed.
Construction of stone masonary valve pit chamber of size 90cm x 90cm x 90 cm (internal dimension) including all necessary excavation and earth work in hard/dense soil and disposal of surplus soil to a distance not exceeding 50 meters & depositing the same as directed including PCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement mortor 1:4 rendering 15 mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externaly as the work proceeds in the same mortar as of stone masonary including mild steel frame (made out of angle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with hinges angle iron flat as required at site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint and all other relevant work complete.
Periodical maintenance / servicing of Diesel Generator set of 200 KVA capacity installed at ICGS Vizhinjam for smooth operation of generator sets and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etc for the following capacity Model/ Make by carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed:- (DG set make:- Engine -Ashok Leyland, Alternator - Kirloskar) Engine Servicing /Gen overhauling :- (a) Checking the lubricant oil, topping up & changing filters if required (b) Checking the lubricant level and replacing if required (c) Checking of alternater, battery charging, fanbelt and adjusting/renewing if required
(d) Checking/adjusting of sensers / controls of the Engine (e) Cleaning the cylinder head, lever, lube oil, gudgen pins etc (f) Draining fuel filter bowels to remove water/sediments and refixing with new gaskets after cleaning/ renewing the filters (g) Checking and tightening all external fasteners and arresting all leakages by renewing deffective nuts bolts washers etc whereever required (h) Checking and arresting leakages by tightening all lube and fuel/ hose connections by renewing defective washers (i) Checking of air filters subject to 250 hrs running or six months whichever is earliest for renewal (j) Cleaning of air filter assembly (k) Renewal of all external rubber parts including radiator hose pipes, sir clips/clamps with nuts bolts etc (l) Arresting all water /lubricant/fuel leakages (m) Checking of all engine parameters and ensuring trouble free performance
(n) Removing US spares and fixing of new spares including testing etc Alternator Servicing :- (a) Checking lubricant in the bearings (b) Checking electrical excitation system and repairing if required (c) Checking alternator insulation values and tightning the electrical connections etc (d) Checking circuits of various connections (e) Cleaning the slip rings/brushes etc (f ) Removing US spares and fixing of new spares including testing etc
AMF Panel Servicing :- (a) AMF Panel will be maintained for good operation with the existing components. Any components found defective will be renewed and paid under relevant item of schedule. (b) Removing US spares and fixing of new spares including testing etc Notes: 1. (a) Spares, lubricant, coolant etc required for engine, main alternator & AMF panel will be measured and paid seperately. (b) Charges for Major repairs / top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted. (c) U/s spares shall be measured under Schedule of Credit 2. DHPP (N) required at the time of mainteance/testing will be issued by MES. 3. Labour charges for dismantling/taking down and replacement/fixing new parts as and when required.
Same as per item No. 81but for 62.5 KVA DG set Ashok Leyland Location:- ICGS Vizhinjam
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 125 -250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make : Kirloskar / Cummins/Crompton Greaves.
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 62.5KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make : Kirloskar / Cummins/Crompton Greaves.
Supply only lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed.
Supply only lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 200 KVA capacities of DG Sets complete all as specified and as directed.
Supply only fuel filter element with 'O' ring as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
Supply only fuel filter element with 'O' ring as required at site for 200 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
Supply only Air filter element inner and outer as required at site with 'O' ring as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
Supply only Air filter element inner and outer as required at site with 'O' ring as required at site for 200 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
Supply only Governor control cable inner and outer for the 15 to 250 KVA cap/make gen set complete all as specified and as directed.
Supply only Lube oil pressure sensor for DG set 200 KVA complete all as specified and as directed.
Supply only Lube oil pressure sensor for DG set 62.5 KVA complete all as specified and as directed.
Supply only AMF relay and replacement of micropocessor 12V/24 complete all as specified and directed.
Removing the silencer and replace with new gasket and manifold to arrest all exhaust leakage for Genset of capacity 62.5 KVA to 250 KVA complete all as specified and as directed.
Supply only 'V' Belts/pump 'V' belts dynamo 'V' belts for 62.5 KVA DG set complete all as specified and as directed.
Supply only 'V' Belts/pump 'V' belts dynamo 'V' belts for 200 KVA DG set complete all as specified and as directed.
Supply only lub oil SAE 15 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling complete all as specified and as directed. Make : Castrol/Power Supreme
Supply only coolant suitable for Diesel generating sets complete all as specified and as directed. Make: Castrol/HP/IOC
Supply and fix in repairs turbo charger assy for 200KVA DG set complete all as specified and as directed.
Supply and fix in repairs turbo charger assy for 62.5KVA DG set complete all as specified and as directed.
Supply and fix in repairs lube oil pump suitable for 200KVA DG set complete all as specified and as directed. Make: Kirlosker/Cummins/Greaves
Supply and fix in repairs self starter suitable for 200KVA DG set complete all as specified and as directed. Make: Kirlosker/Cummins/Greaves
M & L for strip opening of alternator of Capacity 200 KVA DG Set removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding , aligning the alternator with engine and testing on full load, complete all as specified and directed by Engr-in-Charge
M & L cleaning of radiator of 200 KVA DG sets by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/ brezzing and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge
M & L cleaning of radiator of 62.5 KVA DG sets by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/ brezzing and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring , washer and testing suitable for for 200 KVA DG Set complete all as specified and directed by Engr-in-Charge
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring , washer and testing suitable for for 62.5 KVA DG Set complete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of oil spray nozzle for DG set 200 KVA capacity complete all as specified and as directed. Make: Kirlosker/Cummins/Greaves
Repairs to dynamo / alternator including removing from position remove the burntout armature , clean the internal surfaces , servicing, supply and fix new armature with brushes and brush holder , necessary lathe work with bushes etc all as directed
Supply and fix in replacement fuel pipe with banjo bolt at both side of any capacity DG set complete all as specified and as directed. Make: Kirlosker/Cummins/Greaves
Supply and fix in replacement of Dry cell tubular type 12 V / 110- 180 AH and initial charging complete including inbuilt charger including required electrolite /distilled water etc and fixing as required at site to the concerned DG Set all as directed by engineer-in-charge. Make : EXIDE/AMRON
Painting of 200 KVA capacity DG set after preparing the external surface apply one coat of spray painting by superior quality synthetic enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
Painting of 62.5 KVA capacity DG set after preparing the external surface apply one coat of spray painting by superior quality synthetic enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
Periodical maintenance / servicing of Solar Power Plant (on Grid) of 60 KWp capacity installed at power house Vizhinjam for smooth operation of Solar Power Plant and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etc carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed.(Solar Power Panels Make:-Vikram Solar Make of Solar Inverter :- Delta) Solar Panels :- (a) The timely and regular cleaning of solar cells and PV panels. Cleaning of the Soalr Panels shall be done using soft cloth,biodegradable soap, wiper, and a soft bristles brush. Don't use an abrasive sponge or soap to clean the solar panels. (b) Regular maintenance of all thermal-based components. (c) Testing and upkeep of circuits to ensure smooth functioning of the Soalr system. (d) Checking/adjusting of sensers. (e) Carrying out visual inspections of Solar sysytem fortnightly. (f) Conducting verifications of the PV system operations. (g) Tracing of IV curves and thermal imaging. Controller and inverter (a) Testing and upkeep of circuits to ensure smooth functioning of the Solar system. (b) Check the connections, make sure that they are fixed tightly. (c) Maintain the cleanliness of the air intake filter for the smooth functioning of the inverter. (d) Checking of the error code if any and rectify the same.
(e) An electrical inspection to confirm that all the strings of solar array are operating. (f ) Interior inspection of all devices, boxes, inverters, switches, etc. (g) Infrared inspection of electrical connections looking for loose connections and hot spots. Notes: (i) Spares, wires, nut & bolts etc or any other petty/small parts required for maintenance and servicing of the Solar Plant is inclusive in the quotated rate. (ii) Charges for Major repairs, changing of the solar panel, inverter, changing of the contactor will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of Solar plant and Control panel shall be deemed to be included in the rate quoted.
Periodical maintenance / servicing of Electrical Incinerator of 20 KG/Hr capacity for smooth operation by dismantling/opening of the incinerator removing defective parts, replace them with the new parts, cleaning of the entire incinerator from inside, repair to blower fan, MCB, tightening all electrical connection, replace cable lugs and cable gland with new one of existing sizes and ensuring the serviceability of the electrical incinerator by testing of the same after repair complete all as specified and directed for 20 KG/Hr capacity
Supply only Heating coil of 30Kwatt capacity for Electrical Incinerator of 20 KG/Hr capacity of existing make and model all as directed by engineer-in-charge.
Supply only blower fan motor for Electrical Incinerator of 20 KG/Hr capacity of existing make and model all as directed by engineer-in-charge.
Supply only automatic modular contactors with manual override-TP 63Amp for Electrical Incinerator of 20 KG/Hr capacity of existing make and model all as directed by engineer-in-charge.
Note:- (a) Contractors representative / engineer will report to concerned JE E/M in charge of AGE E/M office at fore noon and after noon to collect routine/urgent works related to internal electric supply till completion of work. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screwes, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&P items to his trades man. All routne / urgent job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine / urgent work, the contractor shall be liable to pay the penalty as described in penalty caluse given here as under.
(b) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than eight hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 8 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 8 hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 200/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding.
(c) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Schedule of Credit (Minus) Rs.60420.00 NOTE: Bidder shall insert credit amount of Rs.60420.00 as rate in Green field under Col-13.
M/S AARJAY ASSOCIATES (BID ID -3466525)
Classic Builders (BID ID -3466658)
Kuriako Mathai and company (BID ID -3469378)
SHAIJAL T M (BID ID -3466903)
WELTRONENGINEERINGSERVICES (BID ID -3469429)
Green Ray Enterprises (BID ID -3466745)
ELAN ENGINEERS (BID ID -3469516)
stage.html
html • 0.07 MB
technical_823070.pdf
techsummary_823070.pdf
finance_823070.pdf
BOQ Comparative Chart
xlsx
finsummary_823070.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
8271Tender.pdf
Tender Documents • 1.34 MB
BOQ_823070.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .