Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L5₹38.9 L+₹14.0 L (52.3%)Accepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L5 | Accepted-AOC L1 Bidder amongst bonafide bidder | |
| 2 | L1₹26.7 LRejected-Finance | L1 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. | |
| 3 | L2₹30.5 L+₹3.8 L (14.1%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L2 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. | |
| 4 | L3₹37.2 L+₹10.5 L (39.2%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. | |
| 5 | L4₹38.4 L+₹11.7 L (43.7%)Rejected-Finance | L4 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. |
Tender Value
Refer Docs
EMD Value
₹99,040
Closing Date
31 Oct 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR MANNING AND OPERATION OF WATER SUPPLY IN DSC AND DESIDOC, WATER INSTALLATION IN NORTH GATE AND FIRE FIGHTING INSTALLATIONS SAG AND REPAIR TO WATER SUPPLY SYSTEM IN SANDESH, P-4, P-5, CEPTAM AND ALLIED AREA UNDER GE I RND D
2020_MES_383242_1
GE/RND-54/DLI/2020-2021
Open Tender
Civil Works
Item Rate
330 days
DELHI
Class D, Cat d(v) and a(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹99,040
Yes
5 Jan 2021
3 Oct 2020
2 Nov 2020
3 Oct 2020
31 Oct 2020
19 Oct 2020
Amount
PART-1 OUTSOURCING SERVICES Outsourcing of services for Manning, upkeep and operation to DSC & DESIDOC Pump House Installations and DG set for fire fighting installed at DESIDOC pump house in THREE SHIFTS of 8 hours each per day to be operated in the three shift per day (0600hrs to 1400 hrs Ist Shift, 1400hrs to 2200 hrs 2nd Shift, 2200hrs hrs to 0600 hrs 3rd Shift) from Monday to sunday including holidays by providing and deployment of one skilled mechnic cum operator per shift per day complete all as specified and as directed. The Installation mainly comprises the following :-
DSC Pump House Installation :- (a) 02 Nos pumping sets of capacity 30 HP including connected sluice valves and non return valves complete. (b) 02 Nos pumping sets of capacity 75 HP including connected sluice valves and non return valves complete. (c) 01 No Kirloskar Jockey Pump having discharge 200 GPM at 30 Mtr head including connected sluice valves and non return valves etc. (d) Electrical Control Panels including all controls. DESIDOC Pump House Installation :- (a) 02 Nos pumping sets of capacity 30 HP including connected sluice valves and non return valves complete. (b) 02 Nos pumping sets of capacity 75 HP including connected sluice valves and non return valves complete. (c) 01 No Kirloskar Jockey Pump having discharge 200 GPM at 30 Mtr head including connected sluice valves and non return valves etc. (d) Electric Control Panels including control. (e) Diesel Generating set 250 KVA.
Outsourcing of services for Manning, upkeep and operation to SAG Fire Fighting installation to be operated in one shift per day (0900hrs to 1700hrs hrs) and five days in a week (Monday to Friday, except holidays as declared by Lab) by deploying one skilled Operator cum Mechanic per shift per day complete all as specified and as directed. The Installation mainly comprises the following :- SAG FIRE FIGHTING INSTALLATION :- (a) 01 No. pumping sets of capacity 75 HP including connected sluice valves and non return valves complete. (b) 01 No. jockey pumping sets of capacity 15 HP including connected sluice valves and non return valves complete. (c) 01 No. Deisel driven pumping set of capacity 75 HP including connected sluice valves and non return valves etc. (d) Electrical Control Panel including all controls.
Outsourcing of services for Manning, upkeep and operation to North gate Pump House and DG Set 30 KVA Installation in THREE SHIFTS of 8 hours each per day to be operated in the three shift per day (0600hrs to 1400 hrs Ist Shift, 1400hrs to 2200 hrs 2nd Shift, 2200hrs to 0600 hrs 3rd Shift) from Monday to sunday including holidays by providing and deployment of one skilled mechnic cum operator per shift per day complete all as specified and as directed. The Installation mainly comprises the following :- NORTH GATE Pump House Installation:- (a) 02 Nos Pump & Motors squirrel cage including connected sluice valves and non return valves etc complete maintaining water supply system. (b) Electric control panels including controls. (c) DG Set 30 KVA.
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 3.00 above
Workers wage per person as per existing rules
ESIC (Employees state insurance contribution) as mentioned in tender document
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 4.01 to 4.03
LWC as mentioned in tender documents.
GST as mentioned in tender documents.
Notes : Rate quoted by the contractor shall deemed to be included the following:- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost.
(vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made. (viii) Two pairs of uniform with name plate of operator and shoes shall be provided to each operator by the contractor. (ix) Cleaning of complete installation greasing, tightening of nuts , bolts will be carried out by the operator employed by the contractor. (x) First Aid box will be provided by contractor at each installation. (xi) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xii) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor.
(xiii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiv) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of equipments for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xvi) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvii) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
PART-II: REPAIR/MAINT WORK Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep and getting out complete all as specified and as directed.
All as per item No. 5.00 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc.
Returning, filling in and including spreading, leveling, watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed.
Removing surplus soil to a distance exceeding 1.5Km and not exc 5 km depositing where directed at a level n.exc. 1.5Km above the starting point complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, old size straight or curved on plan exc. 6m mean radius built in CM 1:4 including demolition of old brick work complete all as specified and directed.
M&L for PCC (1:4:8) type D-1(using 40 mm graded stone aggregate) as in foundation complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) finished even and smoooth without using extra cement as in floor, coping etc complete all as specified and directed.
M&L for rendering 10 mm thick on brick work/concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 15mm bore complete all as specified and directed.
Supply and laying in repair tubing GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 20 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 25 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 40 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 50 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 80 mm bore complete all as specified and directed.
Supply and laying in repair GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/ floor as directed of sizes 100 mm bore complete all as specified and directed.
Supplying, Laying, jointing, testing and commmisioning of DI Pipe of 150 mm bore size, with spigot and socketed ends centrifugally cast Class K-7 Push on joint confirming to IS 8329 laid in trenches including taking down old GI pipe complete all as specified and directed.
M&L DI fittings for spigot/socket pipes such as bends of any radious and angle, collars, tapers, tail pieces, Tee pieces, Caps and plugs suitable upto 150 mm bore dia all socketed or socket and spigot or side flanged complete all as specified.
M&L in repair for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrived lead and adding minimum 700 gram new lead for CI pipe of 150mm bore pipes complete all as specified.
M&L in repair for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrived lead and adding minimum 500 gram new lead for CI pipe of 100mm bore pipes complete all as specified.
M&L in repair for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrived lead and adding minimum 400 gram new lea for CI pipe of 800mm bore pipes complete all as specified.
M&L in repair for Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 150 mm bore dia, complete as specified.
Supplying, laying jointing testing in repair MS pipe,of dia 80 mm Heavy duty class 'C' confirming to IS-1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, all as specified. (Note : Welded flanges will be measured and paid seperately.)
Supplying, laying jointing testing in repair MS pipe,of dia 100 mm Heavy duty class 'C' confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, all as specified. (Note : Welded flanges will be measured and paid seperately.)
Supply and fixing welded to flanges on ends for MS pipe of dia 80 mm, flange not less than 15mm thick, complete all as specified and directed.
Supply and fixing welded to flanges on ends for MS pipe of dia 100 mm, flange not less than 15mm thick, complete all as specified and directed.
M&L Joints with rubber or fibre board gasket of size 80 mm complete with nut, bolt and double washers, complete all as specified and directed.
M&L Joints with rubber or fibre board gasket of size 100 mm complete with nut, bolt and double washers, complete all as specified and directed.
Supplying & Fixing ,in repair of cast iron Sluice Valve of dia 50 mm ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
All as per ser item No. 32.00 above but 80mm.
All as per ser item No. 32.00 above but 100mm.
All as per ser item No. 32.00 above but 150mm.
S&F in repair CI Non return Valve of dia 50 mm with GM seat, PN-1.0 ISI mark as per 5312, including flange joints such as packing, nut and bolts complete all as specified and directed.
All as per ser item No. 36.00 above but 80mm.
All as per ser item No. 36.00 above but 100mm.
All as per ser item No. 36.00 above but 150mm.
S&F in repair CI foot valve flanged type of dia 80 mm with strainer confirming to IS:4038 with flanged ends complete all as specified.
All as per ser item No. 40.00 above but 100mm.
All as per ser item No. 40.00 above but 150mm.
Labour for cutting of existing CI / DI pipe of dia 80 mm for insertion of CI specials /valves etc. all as required including dewatering of leakage water all as required complete all as specified and directed.
All as per ser item No. 43.00 above but 100mm.
All as per ser item No. 43.00 above but 150mm.
S&F in repair PTMT Float valve of dia 15 mm with epoxy coated aluminium rod and high density ball including fitting as per IS 12234 complete all as specified and directed.
All as per ser item No. 46.00 above but 20mm.
All as per ser item No. 46.00 above but 25mm.
All as per ser item No. 46.00 above but 40mm.
All as per ser item No. 46.00 above but 50mm.
S&F in repair Gun Metal gate valves of size 15 mm dia with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778.
All as per ser item No. 51.00 above but 20mm.
All as per ser item No. 51.00 above but 25mm.
All as per ser item No. 51.00 above but 40mm.
All as per ser item No. 51.00 above but 50mm.
S&F in repair flanged water meter woltman type of dia 50 mm ISI marked including gasket, nut, bolt & double washer as per ISO 4064.
S&F in repair flanged water meter woltman type of dia 80 mm ISI marked including gasket, nut, bolt & double washer as per ISO 4064.
S&F in repair flanged water meter woltman type of dia 100 mm ISI marked including gasket, nut, bolt & double washer as per ISO 4064.
S&F in repair flanged water meter woltman type of dia 150 mm ISI marked including gasket, nut, bolt & double washer as per ISO 4064.
S&F in repair Strainer Y type conforming to IS, size 80 mm (3”) dia.
S&F in repair Strainer Y type conforming to IS, size 100 mm (4”) dia.
S&F in repair Strainer Y type conforming to IS, size 150 mm (6”) dia.
M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel surface all as specified and directed.
M&L in repair of mild steel work, i.e MS sheet/angle iron, hinges etc incluidng cutting, welding etc complete all as specified and directed.
S&F in repair of PVC tank double layer of capacity 2000 ltrs including connection complete all as specified and directed.
S&F in repair of PVC tank double layer of capacity 3000 ltrs including connection complete all as specified and directed.
S&F in repair of PVC tank double layer of capacity 5000 ltrs including connection complete all as specified and directed. Note for ser item No. 65.00 to 67.00:- Inlet-outlet and air vent pipe will be measured separately in concerned item.
M&L for bocky system under path/road to pass the GI/CI/DI Pipes upto 150 mm dia manually as directed.
Vishal Traders
Rahul Enterprises
dee een enterprises
Pradeep Bros
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .