| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.5 L+₹97,123 (6.69%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.0 L+₹1.5 L (10.2%)Rejected-AOC H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.7 L+₹2.1 L (14.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹16.8 L+₹2.3 L (15.7%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
17 Jun 2020, 6:00 pmClosed
CWE KOTA
HQ CWE Kota Military Engineer Services Dadwara Military Station Kota Rajasthan PIN 324002
CWE KOTA/KOTA-04 OF 2020-21 SPECIAL REPAIR TO BLOCK NO P-318 IN GTC LINE AT MIL STN KOTA
2020_MES_341176_1
81562/KOTA/E8
Open Tender
Civil Works
Item Rate
180 days
KOTA
For Enlisted Contractors Class E Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE KOTA
₹42,000
Yes
13 Aug 2020
27 Apr 2020
19 Jun 2020
27 Apr 2020
17 Jun 2020
5 Jun 2020
27 Apr 2020 - 8 May 2020
Amount
B/R ITEMS Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
Demolition of existing roof treatment /lime concrete PCC padding over RCC roof removing complete layers of bitumen under concrete /PCC Padding, sweeping the surface with wire brusses and cleaning with water to remove all loose dirt etc and removing the rubbish off out side MoD land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
Demolition of cement concrete of any description and in any position otherwise speciafically provided complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm each and removing from site complete all as specified and directed. .
Taking up or down steel tubing and connections including cleaning for refixing or removal complete all as specified and directed:-
15mm bore.
20mm bore.
Dismantling of cement concrete tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of cast iron work of any description complete all as specified and directed.
Dismantling water tank of capacity exceeding 250 Ltrs but not exceeding 500 Ltrs and removal from site complete all as specified and directed.
Taking down & refixing the shutters in same opening of any description n exc. 1 sqm each but exc. 1 sqm and n exc. 2 sqm each after necessary arrangement, complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for walling of random rubble uncoursed well bonded, bedded & solidly hearted stone masonry built in cement mortar 1:4 complete all as specified and directed.
S & F 35mm thick factory made IInd Class Hard wood (Hollock) plain framed, panelled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S & F 35mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F Glass/gauge shall be measured and paid for separately
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part – II.
S&F in repairs drapery curtain rod, fancy type 25 mm dia fabricated out of mild steel sheet not less than 20 gauge and top of drapery rod shall be pretreated powder coated with powder cated brackets and pair of decorated end knobs (finials) complete all as specified and directed.
S&F 3mm thick sheet glass n exc. 0.50 sqm, ordinary quality and glazing in oil putty in square, complete all as specified and directed.
S&F 3mm thick figured glass n exc. 0.50 sqm, ordinary quality and glazing in oil putty in square, complete all as specified and directed.
Supply and fix continuous (Piono) hinges width of flaps (when open) 40mm, MS, bright finish or electro galvanised complete all as specified and directed.
M&L for cutting holes in brick walls/ stone masonary walls built in cement mortar or in cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc. half brick but not exc.one brick complete all as specified and directed.
M & L cutting and punning in brick walls for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm girth but not exc 20 cm girth complete all as directed.
S & F 250 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S & F in repairs towel rail 450 mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (mimimum weight 190 gms), complete all as directed.
S & F in repairs towel ring of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (mimimum weight 90 gms), complete all as directed.
S & F in repair Shelf of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (mimimum weight 300 gms), complete all as directed.
M & L small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours: articles n. exc. 200 cu. cm each complete all as specified and directed.
S & F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in repair GI wire netting 1.40mm dia and 25mm mesh lathing to wood or metal studding, joints etc in walls, ceiling, stanchions, beams etc including all alpse, cutting and waste n exc 5 Sqm each complete all as specified and directed.
M & L for factory made steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete with glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- (i) Window size and pattern wherever required and directed shall be suitable for installing Desert cooler. (ii) Wire mesh shall be measured and paid for separately).
M & L for factory made steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete without glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- (i) Window size and pattern wherever required and directed shall be suitable for installing Desert cooler. (ii) Wire mesh shall be measured and paid for separately).
S&F for steel ventilators, fixed type with glazing bars complete welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- Glass shall be measured and paid for separetely.
S&F in repairs 19mm thick block board grade-1 quality exterior grade decorative veneer on both faces and alround covered with 6mm thick teak wood beading/lipping fixed with screwed to timber frame complete all as specified and directed.
M&L for 50mm thick rough dressed stone slabs for manhole covers n.exc 2 mtr in length, punched dressed on face and along exposed edges, self faced on other side and sets and pointed in cement mortar 1:4 complete all as specified and directed.
M&L preparation new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chorme primer complete all as specified and directed.
M&L preparation old or previously untreated steel surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation old or previously untreated wooden surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of chalk whitening, complete all as specified and directed.
M&L for complete removal of existing treatment on walls, chajjas etc including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over over a thin layer of Birla white putty complete all as specified and directed.
M&L for preparation newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over over a thin layer of Birla white putty complete all as specified and directed.
M & L for brushing neat cement slurry with 3.0 Kg of cement per sq. metre of surface area complete all as directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash on wall complete all as specified and directed.
M&L for preparation of old plastered or previously untreated surfaces of wall surfaces and apply two coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of old plastered or previously untreated surfaces of ceiling and apply two coats of white wash complete all as specified and directed.
S & F wrought plain fillets, square, rectangular or triangular in section, exc 6 sq cm but n exc 13 sq cm clean sawn, secured with screws, complete all as specified and directed.
S & F 300mm size ordinary mild steel, rat tailed rod pattern spring incluidng roller and roller plate welded to mild steel frame complete all as specified and directed.
S & F150mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F 100mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S&F in repairs 100mm size aluminium handles, cast type anodised complete all as specified and directed.
M & L for 50mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
M & L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, steps, seismice and other similar bands copping/cills, parapets and railings upto 60 cm in height including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as directed. (Note : Water proofing liquid shall be measured and paid separately)
Supply only integral water proofing liquid of Dr Fixit/Sika/Fosroc complete all as specified and directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydro Stop manufactured by TIKITAR DANOSA (INDIA) Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
M & L for water proofing treatment in sunken floors as described hereunder:- (i) Sunken floor and sides upto finished floor level shall be plastered with 15mm thick cement plaster in mortar 1:4 mixed with water proofing compound @ 3% by weight of cement. (ii) Preaparing plastered surfaces and providing APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Ltr/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, including preparation of surface by removing the existing treatment, complete all as specified and as directed. Note: (i) Polymeric membrane shall be laid in sunken floor and on sides upto finished floor level. (ii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iii) Above aspects are deemed to be included in quoted rate. (iv) Supply only water proofifng compound shall be measured and paid separately. (v) 32mm dia GI Pipe shall be provided in Sunken slab 30cm projected beyond ext wall face. Note : Slab area only will be measured for payment purpose.
S&F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for MS work conforming to Fe.290.Gde-E-165 as in hold fast of flat iron bands, straps, supports or stays for rain water, ventilating pipes cut to length, bend to shap including bolts if required and wall tie, clamps etc., and including preparing surfaces and treated with tar and sanded with clean sharp sand complete all as specified and directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F mild steel flat iron fillets conforming to FE 290(Gde E-165) for securing wire mesh including all necessary drilling, reveting and bolting etc complete all as specified and directed.
Mild steel screw bolts (machine made) of 10 mm dia of shank and not exc 5 cm long with hexagonal or square head at one end & screw the other or screwed both end, each screwed end to be fitted with washer and one hexagonal or square nut complete all as specified and directed.
S & F for mild steel cupboard shutter with frame, Godrej Pattern, made out of 22 guage mild steel sheet including chromium plated MS handle with proper locking arrangment (brass mortice lock, vertical type, size 65mm, 4 Lever with escutcheon plates & two keys) with & including two coats of spray painting with synthetic enamel paint of approved tint over a coat of red oxide primer including fixing with 06 Nos 12mm dia bolt 150mm long grouted in brick wall/concrete including making good the distrubed sufaces as original complete all as directed. Note : The measurment shall be taken of from elevation and not girthwise
M & L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base to floors finished rough complete all as specified and directed.
M&L 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid in CM 1:4 and jointed with grey cement slurry as in floors or steps tread with single piece incl chipping the steps whre reqd,with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M & L for 16-18mm thick granite, Baroda green, tabular rubbed and polished on cooking platforms and the like, set & jointed with cement slurry and pointed in white cement (1:2) using marble dust with admixture of pigment to match the shade of the granite complete all as specified and directed.
M&L 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid in CM 1:4 and jointed with grey cement slurry as in risers to steps, skirting over rendering in CM 1:4 with single piece incl chipping the steps whre reqd,with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
M & L Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations complete all as specified and directed.
Use and waste of formwork to chajjas/facia flat fair finished surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 10 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc.25cm wide for fair finished surfaces of concrete complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in vertical surfaces such as skirting or dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M&L 300x200x7 mm thick glazed ceramic coloured tiles as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as directed.
M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed.
M & L rednering 10mm thick in CM 1:4 on brick masonry surfaces or on fair faces of brick work masonry finished even complete all as specified and directed.
M & L for 10mm thick rendering in CM 1:4 on stone masonry surfaces, wall surfaces or on other than fair faces of brick wall surfacee for fixing tiles etc. complete all as specified and directed.
M & L for 10mm thick rendering in CM 1:4 on concrete surfaces on ceilings, finished even and smooth without using extra cement complete all as specified and directed.
Cutting existing steel tubing for alterations or additions (Each cut measured) for the following sizes:-
15mm bore.
20mm bore.
25mm bore.
S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. for the following sizes:-
15mm bore.
20mm bore.
Refixing steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. for the following sizes:-
15mm bore.
20mm bore.
S & F in repairs vitreous china wash basin, white, flat back, size 550 x 400 mm including one No PVC waste pipe 25 mm dia and 75 cm long with 32 mm dia connector, 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed complete including cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
S & F in repairs vitreous China squatting pan, Orissa pattern, size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe etc) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete and including making good to floor complete all as specified and directed.
S & F 100mm dia CI traps 'P' or 'S', complete all as specified and directed.
S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S&F 32mm dia waste coupling of PTMT, complete all as specified and directed.
S & F cast iron sanitary connection socket to fit WC outlet, complete all as specified and directed.
S &F in repair 15 mm bore pillar taps, cast copper alloy chromium plated with capstan head screwed down high pressure, with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S & F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including PVC waste pipe complete all as specified and as directed .
S&F swivel shower of PTMT any colour for fixing with 15mm pipe (minimum weight 40 gms) alongwith shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum weight 40 gms) complete all as specified and directed.
S & F stainless steel kitchen plate rack of size 900mm x 1000mm x 200mm fabricated out of Ist quality 0.6mm thick stainless steel sheet including taking down old wooden rack plate complete all as specified and as directed
Taking down and refixing existing steel window shutter after replacing broken projected type hinges with box type hinges including nuts and bolts with necessary welding complete all as specified and directed.
S & F in repairs PVC connection 15mm dia 450mm long with PTMT check nut and washer etc complete all as specified and directed.
S & F in repairs 15mm dia angle valves of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm - 90 gms/20mm - 112 gms) complete all as specified and directed.
S & F in repairs 15mm bore bib tap cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs 15mm bore stop valve cast copper alloy, screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs 20 mm bore dia stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F 500 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repair 15mm bore wall mixer CP brass cromium plated hot and cold with or without telephonic shower arrangement complete all as specified and directed.
S & F in repair 15mm bore basin mixer CP brass cromium plated hot and cold fancy type complete all as specified and directed.
M & L cast iron floor trap, with dia of outlet 75 mm with grating and including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repairs 75mm bore cast iron(sand cast), soil, waste and vent pipe in any length with or without ears with cement joints laid in floors or in trencehes complete all as specified and directed.
S & F in repairs 100mm bore cast iron(sand cast), soil, waste and vent pipe in any length with or without ears with cement joints laid in floors or in trencehes complete all as specified and directed.
S&F stack clamps for 100mm bore pipe out of 50mm X 5mm flat iron and 16mm dia round iron stays, including bolts & nuts and securing ends of stays to wall or roof complete all as specified and directed.
M & L in repairs for 150x150mm size salt glazed stoneware gully traps, square or round mouthed type 'P', jointing to drain pipe with cement mortar 1:2, concrete bed surround/kerb in PCC 1:2:4 type B-1, CI grating including excavation and earth work complete all as specified and directed.
S & F in repairs CI floor trap/Nahani trap with 75mm dia of outlet with grating inclduing jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 complete all as specified and directed.
S & F grating square 150 mm dia of PTMT (Minimum weight 100 gms) complete all as specified and directed.
S & F in repairs CI bends of any radius diminishing piences or tapers (Larger bore measured) with over access door for pipes complete all as specified and directed for following sizes:-
75mm bore.
100mm bore.
S & F in repairs 100mm bore CI bends of any radius with ducks foor or heel rest for pipes complete all as specified and directed.
S & F in repairs 50mm bore CI cowls for vent pipe complete all as specified and directed.
M & L for reinforce cement concrete (RCC) type B1, 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands copping/cills, bed block for embedding hold fast etc including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as directed.
E/M PORTION Taking down the existing old unserviceable point wiring of any description for old light/fan/socket/power including terminal boards, switches, sockets, ceiling roses light fitting etc and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed.
Taking down the existing unserviceable MCB, DBs SPN with MCBs any type after disconnecting incoming and outgoing connections, complete all as specified and directed.
Taking down sub main wiring of any sizes, complete all as specified and directed.
Taking down carefully old ceiling fan/exhaust fan and refixing the same after repair, complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm single core unsheathed stranded copper conductor cable of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping not less than 20mm width with MS sheet metal sunken switch/terminal box 1.2mm thick and phenolic laminated sheet cover 3.0mm thick and brass screws with cup washers with all necessary wall cutting and making good distrubted surface as directed, including all necessay wall cutting and making good disturbed surface including 1.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :-
One light/fan/bell point controlled by one, one way switch.
One light point controled by one, two way switch.
One 3 pin 5 Amps socket outlet point on the same board.
Switch socket combination 5 Amps, 3 pins points on independent board.
One bell/buzzer point controlled by one push button on the same board with other switches
M & L for point wiring complete for 15 Amps socket outlet on independent board with with 2.5 Sqmm single core unsheathed stranded copper conductor cable of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping not less than 20mm width with MS sheet metal sunken switch/terminal box 1.2mm thick and phenolic laminated sheet cover 3.0mm thick and brass screws with cup washers with all necessary wall cutting and making good distrubted surface as directed, including all necessay wall cutting and making good disturbed surface including 2.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor cable to common earth & connecting to earth dolly.
M & L switch piano flush type 5 Amps, single pole, one way, 240 Volts complete all as specified and directed.
S&F, switch socket combination, 5 Amps 240 volt 3 pin flush type universal complete all as specified and directed.
S&F, switch socket combination, 5/15 Amps 240 volt 3/5 pin flush type universal complete all as specified and directed.
S & F socket 3 pin, 5 Amps, 240 V flush type complete all as specified and directed. Make:- Havells/Plaza/Anchor)
S & F lamp holder, PVC / polycarbonate type with back plate suitable for Batten fittings complete all as specified and directed.
S & F ceiling rose, surface bakelite 65x50mm three terminal, PVC / poly carbonate isolated body, complete all as specified and directed.
S & F electronic fan regulator, stepper type, flush tpye, 200W on the existing phenolic laminated sheed complete all as specifed and directed.
S&F electronic bell, AC 230 V, flush type, 5 Amps complete all as specified and directed.
S & F switch bell push, AC 230V single pole 5 Amp, complete all as specified and directed.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 06 Sqmm copper multistranded conductor drawn through and including PVC conduit/casing-caping fixed on surface to wall/ ceiling by means of MS screws and saddles including one run of 6 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and including taking down old u/s sub main wiring complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit/casing-caping will be measured and paid as one length only.
Supply/Laying / fixing, jointing, testing and commissioning in repair under ground cable of size 35 sqmm, 3.5 core 11 KV volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete, all as specified and directed.. NOTE :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items catered in B/R part of the BOQ (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
Supply and fix LED tube light fitting 1x18watt basic all purpose surface and wall mounted MS batten with decorative enf cap, prewired for T8 LED tube light, including 18 Watt LED tube aluminium extruction lamp and mounting clamps etc. complete all as specified and directed. {Model/Make : Product Cat Part No LHEXBQP5IN1W018 of make Havells or equivalent as specified in Appendix 'D'.
Supply and fixing IP-65 rated LED building security light luminary 25 watts AC operation suitable for mounting on GI bracket of 40 mm bore, pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening, separate driver compartment with impact resistance of IK07including mounting bracket fabricated from 40mm dia GI pipe medium grade (upto 1.0 mtr long) with MS clamps nuts bolts of suitable size complete all as directed. {Model/Make :- Product Description 20W5700K Cat Part No. LHETBXU7PA6S020 of make Havells(ENDURA PEARL) or equivalent model of make Philiphs/Crompton/WIPRO/Bajaj ).
Excavation in trenches n. exc 1.5 metre wide and not exceeding 1.5 m deep for foundations, n exc 10 sqm plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, back in trenches complete, all as specified and directed.
Removal of excavated surplus spoil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point,complete, all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement.
S & F sheet metal enclosure double door DB SPN 8 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal single door DB TPN 8 way, 415 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F MCB TPN 63 Amps, 415 volts, B-curve rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified and directed.
S & F MCB SPN 6-40 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB SP 6-32 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
M & L brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed.
S & F of 40mm GI Pipe on wall, light grade for protection of LT cable, complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6.3 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron strip 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 50mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:3:6 type C1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Note :- (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
L P Singh and Co.
Aditya Enterprises
ONKAR ENGINEERS
Ganesh Contruction
K B Enterprises
TARKESHWAR DASS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .