Loading…
Loading…
Tender Value
₹83.9 L
EMD Value
₹1.7 L
Closing Date
4 Jun 2026, 3:00 pmClosed
Electrical Work:-Augmentation of shed facilities to improve the capacity for IOH/ POH of track Machines as well as improving the storage facilities at PD/ DDU.
DDU-EL-G-P-2026-27-02
DDU-EL-G-P-2026-27-02
Open
6 Months
Unknown (Unspecified Location)
₹0
₹1.7 L
11 May 2026
11 May 2026
21 May 2026
A-NS FOR ALL ITEMS
Supply of XLPE LT Aluminium cable of size 4 core x 35 Sq. mm. multistained armoured ISI approved suitable to 1100 volt grade Make: Paragon, Havells,Nicco, Universal.
Transportation of above cable from store to site.
Supply of HDPE Pipe, Laying and drawing of HT / LT cables through Pressure machanism inside the pipe and proper connection to junction Box as per site requirement in all 03 respect ( Size of cable HT / LT 3 core / 4 core from 50 sq mm to 240 sq. mm ), thickness of HDPE should not be less than 06 mm. HDPE should be confirming to IS 14333 1966 or latest.Make of Pipe - Asian, Apollo pipes, Vectus, Utakarsh HDPE pipe , pressure rating at 30 Deg. centigdade : PN 6 , confirmity to IS : 4998 or latest. Thickness of pipe min. 5.3 mm and max. 5.9 mm ISIMarked , CM/L : 7395589, Material Grade : PE 100.
Supply of HDPE, Laying and drawing of HT / LT cables manually inside the pipe and proper connection to junction Box as per site requirement in all respect ( Size of cable HT / LT 3 core 04 / 4 core from 50 sq mm to 240 sq. mm ), thickness of HDPE should not be less than 06 mm. HDPE should be Confirming to IS : 14333 1996 or latest , Thickness of Pipe Min. 5.3 mm and max. 5.9 mm ISI Marked, CM / L : 7395589 , Material Grade : PE 100 , Make of Pipe : Asian, Apollo Pipes, Vectus ,UTAKARSH
Supply, fixing, testing and commissioning of LT cubical panel board of suitable to size of thickness 2 mm to adjust the following switchgears 1). 4 pole 160 A capacity 415 volt AC MCCB - 02 nos. for Incoming, Make :- ABB, Siemens, L& T, Havells, Standard, 2). 4 Pole 63 A capacity 415 volt AC MCCB - 04 no for OUTGOING : ABB, GE, Siemens, l&T, Havells, Indoasian. (Optium), complete in all respect, 03)- SP - 32 Amp. MCB = 16 Nos. as outgoing 4). 4 Pole 200 Amp. on Load changeover Switch = 01 no. 5). Voltmeter (0- 500) with selector switch ammeter with selector switch of make : Kaycee, AE with CT 400/5 of make KAPPA and copper busbar 400 Amp of requiste size as per panel size of 3 phase and neutral with other accessories complete in all respect.
Supply, Fixing , testing and commissioning of MCCB DB for distribution of 3 phase 06 supply 415 volt AC comprising with following : For incoming : 1 ) MCCB 4 pole 100 A - 01 nos, make Siemens cat no. 3 V T 82161 A A - 040 A A Z , OR SIMILAR For Outgoing : 2 ) MCB SP 06 A to 32 AMp - 08 nos, as per site requirement, make: Siemens, L&T, Standard, HPL 3 ) Beta bus plus vertical Bus Bar DBs with MCCB incoming cat No. 8 GB 31571RC Make : Siemens, L&T, Havells, HPL.
Supply & fixing of Industrial type metal clad 5 pin ( 3 P + N + E) Plug and socket 3 Phase , 415 V, 63 Amp . Water proof type . IP 67. Make- Havells, L&T, Neptune, complete in all respect as per site requirement.
Supply, fixing, testing and commissioning of 4 pole 100 Amp MCCB with sheet steel enclosure. Make : siemens, L&T, Havells, Standard.
Supply of 4 Pole 250 Amp MCCB with sheet steel enclosure . Rated short circuit current capacity (in KA) - MCCB with RSCB capacity of 10/16/25/35 KA tripping range , Breaking current (in KA) -25 KA .Rated voltage -240/415 volt 50 Hz AC. Make - HPL, Siemens, L&T, Standard.
Fixing, testing and commissioning of 250 Amp MCCB/Street light Panel.
Supply, Fixing , testing and commissioning of 4 pole 63 Amp MCCB / 440 V A.C with sheet steel enclosure Make Siemens, Havells, Standard, L&T.
Concealed Wiring of Light Point/Fan/Exhaust/ Call Bell point fan point in heavy gauge 12 PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire. Make : Polycab, Anchor, Finolex, RR Kabel, cpntrolling through flush type 10 Amp. switch to be fitted with frame and Tress plate, Make of switch - ROMA, CONA,Schenieder.
Concealed wiring of 6 Amp plug point in heavy gauge PVC conduit pipe as per IS 9537 13 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. Make : Polycab, Anchor, Finolex.controlling through flush type 10 Amp. switch to be fitted with frame and Tress plate , Make - ROMA, CONA, Schenieder
"Supply, fixing, testing and commissioning of 6 Amp/ 16 Amp. Switch, Socket with 14 acessories suitable for 230 V, 50 Hz, Tress Plate with Modular Flush Metal GI Box suitable size as per site requirement duly ISI Approved Make- Leggrand, Havells, Crabtree, wipro, Cona, Anchor or equivalent as per Relevant ISS & IE Rules."
Concealed Wiring of main from main distribution board to sub board in heavy gauge 15 PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 2.5 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells.
Concealed wiring of main from main distribution board to sub board in heavy guage 16 PVC conduit pipe as per IS:9537 with PVC multistrand copper conductor of size 2 x 4 sqmm in voltage grade 1100 volt as per IS:694 with ECC of 1/18 SWG copper wire, make of wire: Finolex, Plaza , Polycab,Havells.
Concealed Wiring of main from main distribution board to sub board in heavy gauge 17 PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 6 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells.
Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x10 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab .
Supply of SPN Distribution Board single Door 4 way Product code DHDNSHODAW08 of Havells. Make :- Havells , L&T, C&S.
Supply of SPN Distribution Board single Door 8 way Product code DHDNSHODAW08 of Havells. Make :- Havells , L&T, C&S.
Supply & fixing of single pole 6 - 16-32 Amp MCB. Make - Havells, Standard , C&S.
"Fixing, testing and commissioning of DB . "
Surface Wiring of main from main distribution board to sub board in heavy gauge PVC 23 conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 2.5 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza Polycab,Havells.
Surface Wiring of light point / Fan Point / Exhaust fan point in heavy gauge PVC 24 conduit pipe as per IS 9537 on surface with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. I) Make of copper wire - Polycab, Anchor, Finolex,Havells, RR Kabel II) Make of Switch/Socket/Ceiling rose/Junction - Anchor,Great,White,Havells, III) PVC Pipe and Accessories - Precision,AKG,Vang.
Surface Wiring of main from main distribution board to sub board in heavy gauge PVC 25 conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 4 sq. mm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire. I) Make of copper wire - Polycab, Anchor, Finolex,Havells, II) Make of Switch/Socket/Ceiling rose/Junction - Anchor,Great,White,Havells, III) PVC Pipe and Accessories - Precision,AKG,Vang.
Surface Wiring of main from main distribution board to sub board in heavy gauge PVC 26 conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 6 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells.
Fixing, Testing and commisioning of BLDC Ceiling fan 5 star rated with suitable clamps ensuring the safety of fan. (Ceiling fan supplied by railway)
Fixing of Exhaust fans with suitable clmps ensuring safety of the fan. (Exhaust fan will be supplied by Railway )
Supply , fixing , testing and commissioning of Tempest 600 mm. heavy duty wall industrial Air Circulator fan for suitable in single phase 230 V , 50 Cycles / Second fixing with suitable clamp . Make - Almonard, Usha, Polar , Khaitan
Supply, Fixing, Testing and commissioning of wall mounted bracket fan of 400 mm. sweep duly ISI approved complete in all respect. make - Khaitan, Usha, Polar,Bajaj. CG.
"Installation ,Fixing,Testing and Commissioning of 2 Tr /1.5Tr split type Air conditioner (supplied by Rly.) "
Supply, Fixing, testing and commissioning of single phase starter with overload protection socket and plug top in plastic enclosure, As per Havells code DHDMCSNO2510525, 25 Amp MCB DBOXX COMBO Make :-North west, Havells,Legrand, Standarad
Supply , fixing , testing and commissioning of Automatic Voltage stabliser of 5 KVA cap. With TDR , input =145 to 280 V AC output =200 to 240 v=/-2 V, cutoff =High/ Low volt, Voltmeter =0-300 V, Make =LOGIC STATE, VENUS, V-Guard, Live- Guard.
Supply of LED HIGHBAY Light (Havells 150/145 Watt LED 75790DLTG) Make : Philips, Havells, Bajaj.
"Supply of 250 Watt / 240 Watt LED Flood Light . Make :- Phillips, Bajaj, Havells, Crompton , Surya"
Supply of 90 W / 92 W LED Street light with pressure die-cast Housing with Toughened Glass and individual LEDs with secondary optics and IP-66 Protection. Make- Philips, Bajaj, Havells, CG.
Fixing of above street light fittings with suitable clamps.
Supply, fixing, connection, testing and commissioning of LED fitting indoor type , Lumen efficiency 100 lumen/watt ,output system wattage 42W (+10%, 5%) with IP 65 or better 38 protection water proof surface/suspendedmounting suitable for operation on 140VA 270V AC supply, LED used in fittings should be of make : NICHIA/OSRAM/SEOUL/CREE/PHILIPS LIMITEDS/LEDNIUM with warranty period of 5 yrs from date of commissioning or 6 yrs from date of supply whichever is earlier complete with testing arrangement. Make : Bajaj, Philips, Havells.
Supply of 20 mtr. Long high mast system with its accessories . Mast shaft shall be in 2 section , hot dip galvanised and suitable for wind velocity as per IS : 875 Pt. -3 it shall also include 39 accessories light mast including head frame steel wire rope 6 mm dia suitable drum winch galvanised lantern carriage arrangement suitable for 12 luminaires symmetrically and its control gear boxes . The Mast shall have an integral power tool mounted at the base compartment for its operation. Make-Bajaj,Aster,BPP.
Supply of foundation nut bolts manufactured from special steel along nuts, washer, Anchor plates and templates. Make - BPP, ,Bajaj,Aster.
Supply of twin dome aviation obstruction light of type BAJOL 2 with 2 Nos. incandescent lamp -100 W.
Supply of Control Panel Housing suitable control circuit for the mast. It shall also consist of suiatble control for the power tool motor duly ISI appvd. Make - BPP,Bajaj,Aster.
Design and casting of suitable shallow foundation with M-15 concrete for the high mast considering the soft soil bearing capacity at site as 10 T per sq. mtr. At 2 mtrs. depth with all materials , labours etc.
Erection of High Mast with the suitable equipment and wiring of lumnaires with all wiring material , labour etc.
Installation of control panel on suitable foundation including all material and labour.
Testing and commissioning of above High mast 20 mtrs.High.
Supply, Fixing, Testing and commissioning of power contactor 3 pole type MX mini 25 47 Amp ML 1.5 type 02 No + 02 NC (coil voltage 240 V / 50 Hz.) as per Cat No. :SS91851 of L&T as per IS 60947-4-1 with enclosure of hylum sheet , Insulator in GI Box of 8" x 6". Make -L&T, Siemens, ABB.
Supply & erection of earthpit as per IS 3043 GI pipe used in size of 50 mm dia x 3 mtrs long medium gauge with alternate layer of charcoal and salt as per Sr. DEE(G) drg no MGS/EL/G/Drg/01/08-09 dt 08.08.08 .Make of GI pipe :Tata, Jindal, Bansal
Supply of Thermoplastic Cable Junction Boxes IP 65 with metric knockouts for cable entry of size maximum upto 240 Sq mm , Size of Jn. Box : 300mm x 600 mm x 170 mm , Cat. No. with terminals K 2404 ( 4 Terminals ) . Make - HENSEL,Synyax,Supreme
Supply of Thermoplastic Cable Junction Boxes IP 65 with metric knockouts for cable 50 entry of size maximum upto 10- 25 Sq mm , Size of Jn. Box : 205 mm x 255 mm x 112 mm , Cat. No. with terminals DK 2500 G ( 4 Terminals ) . Make - HENSEL,Synyax,Supreme
Fixing,testing and commissioning of above junction box.
Supply, erection, testing and commissioning of 80 KW ( In 20 KWp Module ) , ON-Grid Solar PV System with all associated accessories i.e. Net Metering system including Civil Structural work ( As per site requirement ) with 5 Years AMC ) Consisting with all followings Technical Specifications : ( Sl. 1-A to 1-I ) ( MNRE Approved ) A- Solar Photovoltaic Modules : Mono Perk half Cut Capacity of each modules 400Wp. MAKE: Luminous, ABB, Microtek, Hitachi, Havells, Tata Solar , WAREE. B-Module Mounting Structure :Hot dip Galvanized MS Structure for Installation of Modules on Roof with Civil work and aluminium rail structure with end & mid clamps for tin shed MAKE: STEEL: TATA/BHUSHAN/JINDAL ALUMINIUM: SAPA/ TECHNOFAB / UNIVERSAL , PRIME. C-Solar Inverter : Solar 52 String Inverter with MPPT for optimum output MAKE: Luminous, ABB, Microtek, Hitachi, Havells, Tata Solar , WAREE , PowerOne. D- DCDB : DC Disconnect Box for protection of Inverter at DC side with DC SPD and DC Fuse. MAKE: L&T , Siemens, GE, ABB, Havells. E- ACDB : AC Disconnect Box for Protection of Inverter at AC Side with AC SPD,AC MCB , MAKE: L&T , Siemens, GE, ABB, Havells. F- Cables : AC-DC-Earthing Cable as per Plant requirements. G- Earthing : Chemical Maintenance Free Earthing for AC-DC side. H- Other Items : Lugs, Conduits, Glands, Nut Bolts and etc. as per site requirements. I- SPD : SPD Should be provided for both DC & AC side. J-Material Warranty is defined as: a)-The firm should warrant the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than five (05) years from the date of sale to the original customer ("Customer"). ( b) Solar inverter should have warranty of not less than Ten (10) years from the date of sale to the original customer ("Customer")
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of 15 mm dia, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings 53 including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge : Concealed work including cutting chases and making good the walls etc.
Providing and fixing ball valve / Stop Cock (brass) of approved quality 15mm nominal bore
Supply of 15 mm GI Elbow.
Fixing, testing and commissioning of 15 mm dia GI Elbow
Supply of 15 mm x 15 mm x 15 mm dia GI Tee.
Fixing, testing and commissioning of 15 mm x 15 mm x 15 mm dia GI Tee.
Providing and fixing nipple for above pipe
Supply & laying of 3 Core 25 Sq mm Copper UN - Armoured Cable . Make - Havells , Grandlay, RR Kabel
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NewTenderDument2025.pdf
ATTACHMENT
GCC2022UPDATED.pdf
ATTACHMENT
ANNEXURE-VIB.pdf
ATTACHMENT
AnnexureVupdated.pdf
ATTACHMENT
Annexure-VA1.pdf
ATTACHMENT
mandateform.pdf
ATTACHMENT
GCC2022ACSNO.080910.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
Download all tender documents and submit your bid