Tender Value
₹83.9 L
EMD Value
₹1.7 L
Closing Date
4 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
OS CAPITAL
17 conditions · 4 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender
Note:-As per CEE/HJP letter no. ECR/Tender policy/520 dt,23.07.2019 Contractor should have electrical contractor's license of the highest voltage(11 KV or above) at which he will commissioned the system.
Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience 1.1.1 certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
SIMILAR NATURE OF WORK:- 1-Erection of LT or above voltage level distribution panels. 2-Errection and commissioning LT or above voltage 1.1.2 l i n e (Overhead or underground) 3. Electrification/Rewiring service buildings ,Banglow and Qtrs. 4. Supply and erection of tower light. 5.Lightihg of station/ administration buildings/circulation area
30 conditions · 14 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. as the case may be. Following documents should be submitted by the tenderer according to nature of firm, otherwise offer will be treated as invalid: -
Following documents should be submitted by the tenderer in case of HUF: (i) (ii) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
Following documents should be submitted by the tenderer in case of Company registered under Companies Act 2013:(i) (ii) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Following documents should be submitted by the tenderer in case of LLP (Limited Liability Partnership): If the tender is submitted on behalf of a LLP registered under LLP Act-2008, the tenderer shall submit along with the tender: LLP (Limited Liability Partnership): (i) (ii) A copy of LLP Agreement A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet).
Following documents should be submitted by the tenderer in case of Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. 26 GCC April 2022 (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
I/We have read and understood the condition of GCC 2022 and will submit all documents as per GCC 2022.
There should be bond agreement with the Supervisor showing employability with the Firm.
The following documents should be specified for submissionalong with tender
A. List of Personnel, Organization available on hand and proposed to be engaged for the subject work
List of works on hand indicating description of work, contract value,and approximate value of balance work yet to be doneand date of award
Mandate Form/Bank details must be uploaded
The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the qualification criteria mentioned in the tender document.
BIDDER SHOULD SUBMIT ESIC REGISTRATION CERTIFICATE
BIDDER SHOULD SUBMIT EPF REGISTRATION
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
The above power of attorney shall be submitted even if such specific person is authorized for above purposes through partnership deed / Memorandum of Understanding / Article of Association or such other document, failing which tender is liable to be rejected
If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender.
After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society / HUF etc. shall be neither asked nor considered, if submitted. Further, no suo moto cognizance of any document available in public domain (i.e., on internet etc.) or in Railway's record/office files etc. will be taken for consideration of the tender, if no such mention is available in tender offer submitted.
Para 6.1 Part-I of GCC shall be read as under:- The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to annexure-V, in case of other than Company/proprietary firm, Annexure-V A shall also be submitted by the each member of partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership etc.as the case may be. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested/digitally signed by which they/he is qualifying the qualification criteria mentioned in the tender document
There should be bond agreement with the Supervisor showing employability with the Firm OR any other document issued by State/Central government showing supervisors employment with the firm.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Bidders are advised to follow the above eligibility and qualifying criteria and submit documents in proper format toqualify their bid for evaluation of offer. If any of the documents is found missing or not in proper form, their offer will not beconsidered for evaluation and post tendering correspondence will not be made to get any additional paper in support of theirclaim for qualifying and eligibility criteria
Note- Segregation of AC Circuit from other load to be ensured (A) On account 90% payment will be made to contractor against supply, installation,testing and commissioning on production of material inspection certificate receipted challan, joint note with Sr.DEE(G) Authorized supervisor, test certificate of manufactureretc.(b) The number (i.e. maximum/minimum) of on account payment will be decided by the Sr. DEE/G/MGS depending upon the performance of contractor or importance of work.(C) Balance 10% will be released/ paid with the final bill after successful completion, testing & commissioning of the complete awarded/ approved varied workd. In case of AMC 85% quarterly will be made rest 15% payment will be made after successfully completion of three year. Bill passing authority is Sr DEE/G/DDU and Paying authority is SrDFM/ECR/DDU
Contractor is to abide by the provisions of Payment of Wages act & MinimumWages act. In order to ensure the same, an application has been developedand hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractorshall register his firm/company etc. and upload requisite details of labour andtheir payment in this portal. These details shall be available in public domain.The Registration/ updation of Portal shall be done as under: (a)Contractorshall apply for onetime registration of his company/firm etc. in theShramikkalyan portal with requisite details subsequent to issue of Letter ofAcceptance. Engineer shall approve the contractor's registration in the portalwithin 7 days of receipt of such request. (b)Contractor once approved by anyEngineer, can create password with login ID (PAN No.) for subsequent use ofportal for all LoAs issued in his favour. (c)The contractor once registered onthe portal, shall provide details of his Letter of Acceptances (LoA) / ContractAgreements on shramikkalyan portal within 15 days of issue of any LoA forapproval of concerned engineer. Engineer shall update (if required) andapprove the details of LoA filled by contractor within 7 days of receipt of suchrequest. (d)After approval of LoA by Engineer, contractor shall fill the salientdetails of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)Itshall be mandatory upon the contractor to ensure correct and promptuploading of all salient details of engaged contractual labour & paymentsmade thereof after each wage period. While processing payment of any 'OnAccount bill' or 'Final bill' or release of 'Advances' or 'Performance Guarantee /Security deposit', contractor shall submit a certificate to the Engineer orEngineer's representatives that "I have uploaded the correct details of contractlabours engaged in connection with this contract and payments made to themduring the wage period in Railway's Shramikkalyan portal at'www.shramikkalyan.indianrailways.gov.in' till ____Month, ____Year
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway thereunder.
In case of any information submitted by tenderer is found to be false forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Earnest Money Deposit besides banning of business for a period of up to two years.
As per GCC Advance correction slip no.05 para 5 (3) ii. The original Bank Guarantee should be delivered to Office of the Sr.DEE(G)/DDU before closing date for submission of bids (i.e. excluding the last date of submission of bids)
Electrical Work:-Augmentation of shed facilities to improve the capacity for IOH/ POH of track Machines as well as improving the storage facilities at PD/ DDU.
DDU-EL-G-P-2026-27-02
DDU-EL-G-P-2026-27-02
Open
Works - General
6 Months
Chandauli, Uttar Pradesh
₹0
₹1.7 L
4 Jun 2026
11 May 2026
21 May 2026
121 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 83,91,680.99 | ||
| — | 1000.00 | — | — | ||
| Supply of XLPE LT Aluminium cable of size 4 core x 35 Sq. mm. multistained armoured ISI approved suitable to 1100 volt grade Make: Paragon, Havells,Nicco, Universal. | — | — | — | 3,15,900 | |
| — | 4400.00 | — | — | ||
| Transportation of above cable from store to site. | — | — | — | 3,300 | |
| — | 1850.00 | — | — | ||
| Supply of HDPE Pipe, Laying and drawing of HT / LT cables through Pressure machanism inside the pipe and proper connection to junction Box as per site requirement in all respect ( Size of cable HT / LT 3 core / 4 core from 50 sq mm to 240 sq. mm ), thickness of HDPE should not be less than 06 mm. HDPE should be confirming to IS 14333 1966 or latest.Make of Pipe - Asian, Apollo pipes, Vectus, Utakarsh HDPE pipe , pressure rating at 30 Deg. centigdade : PN 6 , confirmity to IS : 4998 or latest. Thickness of pipe min. 5.3 mm and max. 5.9 mm ISIMarked , CM/L : 7395589, Material Grade : PE 100. | — | — | — | 9,71,120.5 | |
| — | 2550.00 | — | — | ||
| Supply of HDPE, Laying and drawing of HT / LT cables manually inside the pipe and proper connection to junction Box as per site requirement in all respect ( Size of cable HT / LT 3 core / 4 core from 50 sq mm to 240 sq. mm ), thickness of HDPE should not be less than 06 mm. HDPE should be Confirming to IS : 14333 1996 or latest , Thickness of Pipe Min. 5.3 mm and max. 5.9 mm ISI Marked, CM / L : 7395589 , Material Grade : PE 100 , Make of Pipe : Asian, Apollo Pipes, Vectus ,UTAKARSH | — | — | — | 5,81,859 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT cubical panel board of suitable to size of thickness 2 mm to adjust the following switchgears 1). 4 pole 160 A capacity 415 volt AC MCCB - 02 nos. for Incoming, Make :- ABB, Siemens, L& T, Havells, Standard, 2). 4 Pole 63 A capacity 415 volt AC MCCB - 04 no for OUTGOING : ABB, GE, Siemens, l&T, Havells, Indoasian. (Optium), complete in all respect, 03)- SP - 32 Amp. MCB = 16 Nos. as outgoing 4). 4 Pole 200 Amp. on Load changeover Switch = 01 no. 5). Voltmeter (0- 500) with selector switch ammeter with selector switch of make : Kaycee, AE with CT 400/5 of make KAPPA and copper busbar 400 Amp of requiste size as per panel size of 3 phase and neutral with other accessories complete in all respect. | — | — | — | 1,67,400 | |
| — | 3.00 | — | — | ||
| Supply, Fixing , testing and commissioning of MCCB DB for distribution of 3 phase supply 415 volt AC comprising with following : For incoming : 1 ) MCCB 4 pole 100 A - 01 nos, make Siemens cat no. 3 V T 82161 A A - 040 A A Z , OR SIMILAR For Outgoing : 2 ) MCB SP 06 A to 32 AMp - 08 nos, as per site requirement, make: Siemens, L&T, Standard, HPL 3 ) Beta bus plus vertical Bus Bar DBs with MCCB incoming cat No. 8 GB 31571RC Make : Siemens, L&T, Havells, HPL. | — | — | — | 17,533.14 | |
| — | 20.00 | — | — | ||
| Supply & fixing of Industrial type metal clad 5 pin ( 3 P + N + E) Plug and socket 3 Phase , 415 V, 63 Amp . Water proof type . IP 67. Make- Havells, L&T, Neptune, complete in all respect as per site requirement. | — | — | — | 1,38,623 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of 4 pole 100 Amp MCCB with sheet steel enclosure. Make : siemens, L&T, Havells, Standard. | — | — | — | 12,154.76 | |
| — | 4.00 | — | — | ||
| Supply of 4 Pole 250 Amp MCCB with sheet steel enclosure . Rated short circuit current capacity (in KA) - MCCB with RSCB capacity of 10/16/25/35 KA tripping range , Breaking current (in KA) -25 KA .Rated voltage -240/415 volt 50 Hz AC. Make - HPL, Siemens, L&T, Standard. | — | — | — | 48,000 | |
| — | 4.00 | — | — | ||
| Fixing, testing and commissioning of 250 Amp MCCB/Street light Panel. | — | — | — | 1,281.6 | |
| — | 6.00 | — | — | ||
| Supply, Fixing , testing and commissioning of 4 pole 63 Amp MCCB / 440 V A.C with sheet steel enclosure Make Siemens, Havells, Standard, L&T. | — | — | — | 14,407.44 | |
| — | 250.00 | — | — | ||
| Concealed Wiring of Light Point/Fan/Exhaust/ Call Bell point fan point in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire. Make : Polycab, Anchor, Finolex, RR Kabel, cpntrolling through flush type 10 Amp. switch to be fitted with frame and Tress plate, Make of switch - ROMA, CONA,Schenieder. | — | — | — | 1,06,322.5 | |
| — | 70.00 | — | — | ||
| Concealed wiring of 6 Amp plug point in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. Make : Polycab, Anchor, Finolex.controlling through flush type 10 Amp. switch to be fitted with frame and Tress plate , Make - ROMA, CONA, Schenieder | — | — | — | 19,898.9 | |
| — | 45.00 | — | — | ||
| "Supply, fixing, testing and commissioning of 6 Amp/ 16 Amp. Switch, Socket with acessories suitable for 230 V, 50 Hz, Tress Plate with Modular Flush Metal GI Box suitable size as per site requirement duly ISI Approved Make- Leggrand, Havells, Crabtree, wipro, Cona, Anchor or equivalent as per Relevant ISS & IE Rules." | — | — | — | 13,272.3 | |
| — | 3800.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 2.5 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells. | — | — | — | 1,71,874 | |
| — | 1500.00 | — | — | ||
| Concealed wiring of main from main distribution board to sub board in heavy guage PVC conduit pipe as per IS:9537 with PVC multistrand copper conductor of size 2 x 4 sqmm in voltage grade 1100 volt as per IS:694 with ECC of 1/18 SWG copper wire, make of wire: Finolex, Plaza , Polycab,Havells. | — | — | — | 93,525 | |
| — | 900.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 6 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells. | — | — | — | 64,458 | |
| — | 400.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x10 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab . | — | — | — | 29,836 | |
| — | 6.00 | — | — | ||
| Supply of SPN Distribution Board single Door 4 way Product code DHDNSHODAW08 of Havells. Make :- Havells , L&T, C&S. | — | — | — | 5,087.22 | |
| — | 4.00 | — | — | ||
| Supply of SPN Distribution Board single Door 8 way Product code DHDNSHODAW08 of Havells. Make :- Havells , L&T, C&S. | — | — | — | 3,953.36 | |
| — | 56.00 | — | — | ||
| Supply & fixing of single pole 6 - 16-32 Amp MCB. Make - Havells, Standard , C&S. | — | — | — | 6,091.12 | |
| — | 10.00 | — | — | ||
| "Fixing, testing and commissioning of DB . " | — | — | — | 701.5 | |
| — | 4499.00 | — | — | ||
| Surface Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 2.5 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza Polycab,Havells. | — | — | — | 2,10,058.31 | |
| — | 300.00 | — | — | ||
| Surface Wiring of light point / Fan Point / Exhaust fan point in heavy gauge PVC conduit pipe as per IS 9537 on surface with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. I) Make of copper wire - Polycab, Anchor, Finolex,Havells, RR Kabel II) Make of Switch/Socket/Ceiling rose/Junction - Anchor,Great,White,Havells, III) PVC Pipe and Accessories - Precision,AKG,Vang. | — | — | — | 30,453 | |
| — | 2500.00 | — | — | ||
| Surface Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 4 sq. mm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire. I) Make of copper wire - Polycab, Anchor, Finolex,Havells, II) Make of Switch/Socket/Ceiling rose/Junction - Anchor,Great,White,Havells, III) PVC Pipe and Accessories - Precision,AKG,Vang. | — | — | — | 1,78,125 | |
| — | 1075.00 | — | — | ||
| Surface Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 6 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells. | — | — | — | 1,22,646.75 | |
| — | 45.00 | — | — | ||
| Fixing, Testing and commisioning of BLDC Ceiling fan 5 star rated with suitable clamps ensuring the safety of fan. (Ceiling fan supplied by railway) | — | — | — | 1,771.65 | |
| — | 10.00 | — | — | ||
| Fixing of Exhaust fans with suitable clmps ensuring safety of the fan. (Exhaust fan will be supplied by Railway ) | — | — | — | 634.6 | |
| — | 25.00 | — | — | ||
| Supply , fixing , testing and commissioning of Tempest 600 mm. heavy duty wall industrial Air Circulator fan for suitable in single phase 230 V , 50 Cycles / Second fixing with suitable clamp . Make - Almonard, Usha, Polar , Khaitan | — | — | — | 1,62,852.75 | |
| — | 10.00 | — | — | ||
| Supply, Fixing, Testing and commissioning of wall mounted bracket fan of 400 mm. sweep duly ISI approved complete in all respect. make - Khaitan, Usha, Polar,Bajaj. CG. | — | — | — | 12,938.6 | |
| — | 6.00 | — | — | ||
| "Installation ,Fixing,Testing and Commissioning of 2 Tr /1.5Tr split type Air conditioner (supplied by Rly.) " | — | — | — | 4,430.64 | |
| — | 6.00 | — | — | ||
| Supply, Fixing, testing and commissioning of single phase starter with overload protection socket and plug top in plastic enclosure, As per Havells code DHDMCSNO2510525, 25 Amp MCB DBOXX COMBO Make :-North west, Havells,Legrand, Standarad | — | — | — | 2,266.5 | |
| — | 6.00 | — | — | ||
| Supply , fixing , testing and commissioning of Automatic Voltage stabliser of 5 KVA cap. With TDR , input =145 to 280 V AC output =200 to 240 v=/-2 V, cutoff =High/ Low volt, Voltmeter =0-300 V, Make =LOGIC STATE, VENUS, V-Guard, Live- Guard. | — | — | — | 18,134.52 | |
| — | 39.00 | — | — | ||
| Supply of LED HIGHBAY Light (Havells 150/145 Watt LED 75790DLTG) Make : Philips, Havells, Bajaj. | — | — | — | 2,96,166 | |
| — | 30.00 | — | — | ||
| "Supply of 250 Watt / 240 Watt LED Flood Light . Make :- Phillips, Bajaj, Havells, Crompton , Surya" | — | — | — | 3,89,700 | |
| — | 20.00 | — | — | ||
| Supply of 90 W / 92 W LED Street light with pressure die-cast Housing with Toughened Glass and individual LEDs with secondary optics and IP-66 Protection. Make- Philips, Bajaj, Havells, CG. | — | — | — | 72,112.8 | |
| — | 89.00 | — | — | ||
| Fixing of above street light fittings with suitable clamps. | — | — | — | 7,493.8 | |
| — | 80.00 | — | — | ||
| Supply, fixing, connection, testing and commissioning of LED fitting indoor type , Lumen efficiency 100 lumen/watt ,output system wattage 42W (+10%, 5%) with IP 65 or better protection water proof surface/suspendedmounting suitable for operation on 140VA 270V AC supply, LED used in fittings should be of make : NICHIA/OSRAM/SEOUL/CREE/PHILIPS LIMITEDS/LEDNIUM with warranty period of 5 yrs from date of commissioning or 6 yrs from date of supply whichever is earlier complete with testing arrangement. Make : Bajaj, Philips, Havells. | — | — | — | 1,39,208 | |
| — | 2.00 | — | — | ||
| Supply of 20 mtr. Long high mast system with its accessories . Mast shaft shall be in 2 section , hot dip galvanised and suitable for wind velocity as per IS : 875 Pt. -3 it shall also include accessories light mast including head frame steel wire rope 6 mm dia suitable drum winch galvanised lantern carriage arrangement suitable for 12 luminaires symmetrically and its control gear boxes . The Mast shall have an integral power tool mounted at the base compartment for its operation. Make-Bajaj,Aster,BPP. | — | — | — | 2,29,489.98 | |
| — | 2.00 | — | — | ||
| Supply of foundation nut bolts manufactured from special steel along nuts, washer, Anchor plates and templates. Make - BPP, ,Bajaj,Aster. | — | — | — | 4,728.18 | |
| — | 2.00 | — | — | ||
| Supply of twin dome aviation obstruction light of type BAJOL 2 with 2 Nos. incandescent lamp -100 W. | — | — | — | 2,933.94 | |
| — | 2.00 | — | — | ||
| Supply of Control Panel Housing suitable control circuit for the mast. It shall also consist of suiatble control for the power tool motor duly ISI appvd. Make - BPP,Bajaj,Aster. | — | — | — | 28,120.76 | |
| — | 2.00 | — | — | ||
| Design and casting of suitable shallow foundation with M-15 concrete for the high mast considering the soft soil bearing capacity at site as 10 T per sq. mtr. At 2 mtrs. depth with all materials , labours etc. | — | — | — | 47,799.06 | |
| — | 2.00 | — | — | ||
| Erection of High Mast with the suitable equipment and wiring of lumnaires with all wiring material , labour etc. | — | — | — | 14,860.94 | |
| — | 2.00 | — | — | ||
| Installation of control panel on suitable foundation including all material and labour. | — | — | — | 1,821.4 | |
| — | 2.00 | — | — | ||
| Testing and commissioning of above High mast 20 mtrs.High. | — | — | — | 1,513.98 | |
| — | 2.00 | — | — | ||
| Supply, Fixing, Testing and commissioning of power contactor 3 pole type MX mini 25 Amp ML 1.5 type 02 No + 02 NC (coil voltage 240 V / 50 Hz.) as per Cat No. :SS91851 of L&T as per IS 60947-4-1 with enclosure of hylum sheet , Insulator in GI Box of 8" x 6". Make -L&T, Siemens, ABB. | — | — | — | 5,819.66 | |
| — | 10.00 | — | — | ||
| Supply & erection of earthpit as per IS 3043 GI pipe used in size of 50 mm dia x 3 mtrs long medium gauge with alternate layer of charcoal and salt as per Sr. DEE(G) drg no MGS/EL/G/Drg/01/08-09 dt 08.08.08 .Make of GI pipe :Tata, Jindal, Bansal | — | — | — | 32,756.6 | |
| — | 2.00 | — | — | ||
| Supply of Thermoplastic Cable Junction Boxes IP 65 with metric knockouts for cable entry of size maximum upto 240 Sq mm , Size of Jn. Box : 300mm x 600 mm x 170 mm , Cat. No. with terminals K 2404 ( 4 Terminals ) . Make - HENSEL,Synyax,Supreme | — | — | — | 46,935.32 | |
| — | 4.00 | — | — | ||
| Supply of Thermoplastic Cable Junction Boxes IP 65 with metric knockouts for cable entry of size maximum upto 10- 25 Sq mm , Size of Jn. Box : 205 mm x 255 mm x 112 mm , Cat. No. with terminals DK 2500 G ( 4 Terminals ) . Make - HENSEL,Synyax,Supreme | — | — | — | 10,432.24 | |
| — | 6.00 | — | — | ||
| Fixing,testing and commissioning of above junction box. | — | — | — | 2,106.84 | |
| — | 4.00 | — | — | ||
| Supply, erection, testing and commissioning of 80 KW ( In 20 KWp Module ) , ON-Grid Solar PV System with all associated accessories i.e. Net Metering system including Civil Structural work ( As per site requirement ) with 5 Years AMC ) Consisting with all followings Technical Specifications : ( Sl. 1-A to 1-I ) ( MNRE Approved ) A- Solar Photovoltaic Modules : Mono Perk half Cut Capacity of each modules 400Wp. MAKE: Luminous, ABB, Microtek, Hitachi, Havells, Tata Solar , WAREE. B-Module Mounting Structure :Hot dip Galvanized MS Structure for Installation of Modules on Roof with Civil work and aluminium rail structure with end & mid clamps for tin shed MAKE: STEEL: TATA/BHUSHAN/JINDAL ALUMINIUM: SAPA/ TECHNOFAB / UNIVERSAL , PRIME. C-Solar Inverter : Solar String Inverter with MPPT for optimum output MAKE: Luminous, ABB, Microtek, Hitachi, Havells, Tata Solar , WAREE , PowerOne. D- DCDB : DC Disconnect Box for protection of Inverter at DC side with DC SPD and DC Fuse. MAKE: L&T , Siemens, GE, ABB, Havells. E- ACDB : AC Disconnect Box for Protection of Inverter at AC Side with AC SPD,AC MCB , MAKE: L&T , Siemens, GE, ABB, Havells. F- Cables : AC-DC-Earthing Cable as per Plant requirements. G- Earthing : Chemical Maintenance Free Earthing for AC-DC side. H- Other Items : Lugs, Conduits, Glands, Nut Bolts and etc. as per site requirements. I- SPD : SPD Should be provided for both DC & AC side. J-Material Warranty is defined as: a)-The firm should warrant the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than five (05) years from the date of sale to the original customer ("Customer"). ( b) Solar inverter should have warranty of not less than Ten (10) years from the date of sale to the original customer ("Customer") | — | — | — | 32,11,999.56 | |
| — | 16.00 | — | — | ||
| Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of 15 mm dia, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge : Concealed work including cutting chases and making good the walls etc. | — | — | — | 4,039.2 | |
| — | 4.00 | — | — | ||
| Providing and fixing ball valve / Stop Cock (brass) of approved quality 15mm nominal bore | — | — | — | 831.96 | |
| — | 8.00 | — | — | ||
| Supply of 15 mm GI Elbow. | — | — | — | 278.24 | |
| — | 8.00 | — | — | ||
| Fixing, testing and commissioning of 15 mm dia GI Elbow | — | — | — | 74.4 | |
| — | 8.00 | — | — | ||
| Supply of 15 mm x 15 mm x 15 mm dia GI Tee. | — | — | — | 419.44 | |
| — | 8.00 | — | — | ||
| Fixing, testing and commissioning of 15 mm x 15 mm x 15 mm dia GI Tee. | — | — | — | 74.4 | |
| — | 8.00 | — | — | ||
| Providing and fixing nipple for above pipe | — | — | — | 308.88 | |
| — | 125.00 | — | — | ||
| Supply & laying of 3 Core 25 Sq mm Copper UN - Armoured Cable . Make - Havells , Grandlay, RR Kabel | — | — | — | 3,08,743.75 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NewTenderDument2025.pdf
ATTACHMENT
GCC2022UPDATED.pdf
ATTACHMENT
ANNEXURE-VIB.pdf
ATTACHMENT
AnnexureVupdated.pdf
ATTACHMENT
Annexure-VA1.pdf
ATTACHMENT
mandateform.pdf
ATTACHMENT
GCC2022ACSNO.080910.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .