Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | L1 | Accepted-AOC Tender awarded to contractor due to lowest rates | |
| 2 | L2₹31.2 L+₹36,483.02 (1.18%)Rejected-AOC MOGA | L2 | Rejected-AOC Contractor rejected due to highest rates. |
Tender Value
Refer Docs
EMD Value
₹61,631
Closing Date
25 Feb 2021, 5:00 pmClosed
Executive Engineer
Water Supply and Sanitation Division No.1 Ludhiana
Providing and Installing Tubewell 200mm id 150 mtr depth Pipeline for distribution uPVC pipe including cost of excavation dismantling of bricks in trenches House hold connection and Water Meter Repair of OHSR Pump Chamber and Staff Qtr. develop etc.
2021_WB_60036_1
No.790dt.12-02-2021
Open Tender
Civil Works
Item Wise
90 days
Ludhiana
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹61,631
9 Apr 2021
13 Feb 2021
26 Feb 2021
13 Feb 2021
25 Feb 2021
13 Feb 2021
Amount
TUBEWELL
Drilling of 500mm dia bore with Reverse Rotary Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to site complete in all respect.
Drilling of 500mm dia bore with Reverse Rotary Rig up to 150mtr. Depth BGL
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm nominal diameter (weight 33.6 kg per meter) 6.4mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS : 8110-2000 or latest with SS socket to connect Stainer to Strainer Duly welded with suitable grade S. S welding electrode to lower the strainer into tubewell bore.
200mm Steel Strainer (slot size 0.75mm) 6.30mm thickness.
Supplying, Fixing & lowering of Stainless Steel soket as per IS 8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect.
Supplying, lowering & fixing of M.S Special soket to connect S.S strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respect.
Making electric logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respects.
Supplying and fixing mild steel centering guides made out of 32mm X 6mm thick M.S bar complete in all respect
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annual space between the pipes assembly & bore. The gravel should be free from dust, dirt, or the vegetable manner as per IS 4097-1967 with latest amendments
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Supplying and fixing well cap having thread to fix on housing pipe complete in all respect.
200mm internal diameter
Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
200mm internal diameter (weight 33.60 kg per meter) 6.40 mm thickness
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost of Nut & Bolts of suitable size complete in all respects.
Development and stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development and stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Uranium etc.)
Earth, Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth.
Supplying of tibba sand/ local sand over packing & clay seal upto G.L. below pipe assembly & bore including carriage complete in all respect.
Supplying and fixing sanitary seal having rubber tight on housing pipe complete in all respect. (as per BIS-2800:2019)
Supplying of clay to provide impervious layer in below pipe assembly & bore above gravel packing all including carriage. (as per BIS-2800:2019)
Sterilization of Well (as per BIS-2800:2019)
PUMPING MAIN
Providing, Stringing out, cutting, Jointing & testing of ISI marked D.I pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, Jointed with rubber tyton jointes fitted complete including all cartage & specials including cost of earth work in excavation & back complete as per analysis A-19
150 mm DI K9 Pipe
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (1 no. each of size 0.9m x 0.9m)
REPAIR OF OHSR
Construction of plinth protection around OHSR with masonry toe wall & inside earth filling with lead 5 kms. complete in all respect as per drawing D-9 complete in all respects. OHSR-1,00,000 ltr Capacity
Construction of brick masonry over flow houdi of size 1.20 x 1.20 x 1.20 m for OHSR complete in all respects.
Providing Automated Water Controller complete in all respects.
REPAIR OF PUMP CHAMBER
Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) (g) 30mmm thick
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work Painting one coat with readymixed paint of metallic surfaces in all shades on old steel or iron works.
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
12.5mm thick cement plaster in 1:4
Conglomerate floor 50mm thick cement concrete rete 1:2:4 with stone aggregate 40mm gauge and 100mm thick fine sand thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material.
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position.
panelled, glazed or glazed and panelled.
40 mm thick
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing.
First class burnt brick work laid in cement sand mortar 1:2 in first storey upto 4 metres above plinth level.
Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
DISTRIBUTION NETWORK
Providing, Stringing out uPVC 6kg/sqcm pipes and specials ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete including cost of earthwork in excavation and back filling complete as per specifications for less than 3 mtr street width. (Manualy)
PVC Pipe 50 mm o/d
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
PVC Pipe 50 mm o/d
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6m x 0.6m
Connection of new pipe line with exist pipe line including correct alignment and gradients, cutting. Jointing and testing complete including cost of earthwork in excavation and back filling complete as per specifications complete in all respect
HOUSE SERVICE CONNECTION WITH WATER METER
Providing Household connection laying, jointing, fixing, testing MDPE Pipes (As approved by Engineer-in-Charge), including cost of excavation, refilling, C.I bib cock as IS:210 with stainless steel spindle 20mm o/d MDPE pipe 4.50 mtr. (2.50 mtr. MDPE & 2.00 mtr. G.I, Vertical Pipe) 3" i/d uPVC clamps, GM ferrule ISI marked connection of 15mm i/d ferrule medium, special such as tees, bends, sockets, elbows, nipples (100mm & 150mm) union couplings, G.I Hooks etc. and Gun metal peet valve (heavy pattern) with hand wheels on MDPE pipe line laid in the ground or inside building, cutting, treading. making hole in the wall. Fixing and jointing water meter (Multi Jet) in G.I. pipe including cutting and threading pipe and making long screw etc. complete including cost of G.I. jam nut complete in all respect. 336 water connection + 604 water meter (Abstract Attachedt)
Household connection
Water Meter
CHLORINATOR PLANT
Providing, installing, testing & commissioning one no. Electrically actuated, diaphragm operated, Metering system, chemical dosing Chlorinator, suitable for delivering 0.5 to 0.6 litres of bleaching powder solution/ sodium hypo solution per hour under maximum delivering pressure upto 7 kgcm² and suction lift not less than 1.5m as per DWSS standard Specification.
PUMPING MACHINERY
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 619 LPM against a head of 74.00 mtr (20.00 BHP) complete in all respect. 1)Providing & Fixing of Electric Control panel board Consisting of elctric appliances such as automatic Star Delta Push Button, (As per PSPCL norms) Main Switch, VM, Ampere, Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc.complete in all respect. 2)Providing & Fixing of submersible cable 6mm² =92m complete in all respects. 3)Providing & Fixing of M.S Column Pipe of 100mm i/d 46 m complete in all respects. NOTE: Old submersible use for connection for proposed tubewell about 100mtr. Credit of old machinery,Column Pipe.
DEVELOPMENT OF WATER WORKS
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in the rows complete in all respects including cost of winding wire & aluminum painting complete in all respects
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing
Cement concrete 1:4:8 For Repair of`foot path Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works.
with brick balast 40mm gauge
mixing by manual means
Painting on Board both sides including priming coat , printing & Map as per Water Supply & Sanitaton standard
ENVIRONMENT MANAGEMENT
Planting hedge including digging of trench 60 cm wide to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 30cm distance from plant to plant in two rows.
Rough grassing including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, levelling and dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting doob grass in rows 15 cm apart in both directions, watering and maintenance till first mowing.
Supplying and planting permanent trees in prepared pits and watering
Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
Planting Rose beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, triangular planting of sapling at 60cm distance from plant to plant and row to row.
Provision for one way stand post khuraah
Provision for bleaching Powder or sodium chloride for disinfection of water.
GURCHARAN SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .