Loading…
Loading…
Tender ID
Tender Value
₹87.7 L
EMD Value
₹1.6 L
Closing Date
6 Apr 2026, 6:30 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
COMPREHENSIVE MAINTENANCE OF RACK AND PINION TYPE DOCK LIFTS AND NUMERIC VALVE POSITION INDICATION SYSTEM FOR EXISTING 1800MM DIA BFV VALVES WITH CONNECTED ASSOCIATED ACCESSORIES AT SDD AND NDD PUMP HOUSES AND DRYDOCKS AT NAVAL DOCKYARD VISAKHAPATNAM
2026_MES_753741_1
8483/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹1,000
GE (I) DM Visakhapatnam
₹1.6 L
Yes
23 Mar 2026
21 Feb 2026
8 Apr 2026
21 Feb 2026
6 Apr 2026
14 Mar 2026
22 Feb 2026 - 12 Mar 2026
Comprehensive maintenance and repairs of electrically operated Three numbers Passenger Lift ( NDD-1, SDD-1, SDD Outer-01 No) Elevator of 1000 Kg capacity rack & pinion system, with double motor to operate G + 1, 13 M height for collapsible gate floor installed at Varun Block Inner lift { Make: MEKASTAR}, keeping the lifts and its accessories in perfect working condition including repair/renewal & replacement of all defective / worn out spare parts and supply & fixing minor spares, carrying out periodic checking of all instrument/ accessories/ controls as per schedule carrying out artificial load testing twice in the contract period at an interval of not more tan six months to ensure smooth / safe and efficient operation of lifts compete all as specified and directed. Note :- The contractor has to carryout the AMC of the lifts through OEM/their accerdited/auth agencies.
M&L Repairs to collapsible gate assembly incl. replacement of roller wheel of size as existing for any floor/ car including replacement of old unenviable rubber bushes and damaged grill handles with new ones and greasing etc., complete all as specified and directed.
M&L for preparation of old painted surface of passenger / goods lift cabin car including door/ collapsible gate at all floors, control panel, motors, gearbox, counter weights and other steel surfaces and applying one coat of synthetic enamel paint of shade same as existing all as specified and directed.
Supply only drive unit which includes (break Motors, gear Box, couplings, flange, c.f brakes, pinion, complete drive unit assly) all as specified and directed.
Supply only cage Limit switch all as specified and directed.
Supply only cable trolley guide roller
Supply only counter roller
Saupply only guide roller
Supply only cage panel (with out TFR)
Supply only base panel complete
Supply only complete tool box
Supply only Hex Bolt 1"x10" (Mast bolt) with nut
Supply only Hex Bolt m12x90 mm with nut & washer
Supply only Hex bolt M12X110 mm with nut & washer
Supply only J bolt small M10 X 70 mm with but & washer
Supply only J bolt big M10 X 125 mm with but & washer
Supply only limit switch up & down - LL1 with arms
Supply only Mast Cable Backet
Supply only Manual Break releasing system (set)
Supply only PU Bush for Machinery plate with nut and bolts
Supply only safety device module - 5 for 1000 kgs elevator
Supply only three phase final limit switch 63 AMP
Supply only trailing power cable (4 core x 16 mmsq)
Supply only TIE INS pipe
Supply only cage cable bracket - left & right
Supply only limit/up & down cam with fastners
Supply only safety hook with Nut & bolts
Supply only cable trolley Teflon roller 1 set
Supply only cage push button box
Supply only PROXIMITY switch (Sensor for limit cam)
Supply only drop test PB station with cable (KIT)
Supply only landing cam with fastner
Supply only foundation bolt 1" UNC X 450 mm long
Supply only base frame bolt (FULL THREAD)
Supply only cable guide with J Bolt 10 x 125 mm with nut & washer
Supply only machinery plate 1000 kg
Supply only VFD FX 2000 of Make L&T or Equivalent
Supply only Limit Switches
Supply only Emergency Stop Push Buttons
Supply only PUSH BUTTONS
Supply only Serviceable and Control wirings of the panels
Supply only Hour Meter
Supply only Battery 12V 10-25AH
Supply only Transformer 400VA
Supply only Thermostat
Supply only Door Limit switches of panel
Supply only Termination Connectors
Supply only NO-NC Contactors
Supply only Contactors of different ranges (as suited to site)
Supply only HRC fuses 100 Amps
Supply only AC-DC Convertor
Supply only MCB SP 6-32 Amps, 10kA
Supply only Single Phase Preventer
Supply only Main Switch 125 Amps, 415V, 50 Hz
Repair/ replace passenger cabins by changing enclosures with SS sheets inside, providing non-skid mats for floors, provisioning scissor type doors along provisioning of sufficient illumination & ventilation system all as specified and directed.
Painting of lift structural members post surface preparation to ST3 standard, one coat of primer, one coat of anticorrosive and finish coat of PU paint complete all as specified and directed
Load test to be carried out as standard procedure by competent authorized person. Load blocks arrangement, handling, transportation & securing of load blocks should be contractor scope all as specified and directed.
S&F of PLC/MIMIC based Local and Remote Display for Descete Valve Position Instrument System to buttter fly valve of 1800mm & 900mm dia at SDD Pump House by providing all the sensors with proper base nad holidings on the Gear Box without distrubing the existinm Stsyem Note : Sunnpy only spare parts required shall be measured and paid separately under relevant items of Sch 'A'.
Supply the following mandatory spares as required during Installation of PLC Based Valve Position indication Insturment System for 1800mm & 900mm dia Butterfly Valve of SDD Pump House for specified schedule
Supply only Set of 05 in no, 24V DC Proximity Sensor to the suitable existing 1800mm dia BFV valve
Supply only Compactable Panel Board of size (LxWxH) 400x300x200 mm
Supply only 7 inch Display for showing the indication of the valve by Proximity Sensor
Supply only Compact suitable MIMIC/ PLC with 16 IN/OUT or sufficient I/Os channel point as suggested & directed by Engineer In-Charge
Supply only Power Supply MCB, 220V
Supply only Local Display suitable to site fit for showing the indication of the valve by Proximity Sensor
Supply only Junction Box of 220V
Supply only CAT cable
Supply only Power Supply protection 220V, 50 Hz, MCB
Supply only 8 Core, 0.5 sqmm Armoured control cable laying from SDD pump house to SCADA control room/ Duty watch room of SDD Office space
Supply only 5 Port Ethernet Switch cable all integrated/ programmed for operation on Ethernet platform for indication of valve at (i) Full Close (ii) 1/4 Open (iii) 1/2 Open (iv) 3/4 Open (v) Full Open
stage.html
html • 0.01 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_844249.xls
BOQ • 0.35 MB
8483Tender.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .