Loading
Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
8 Aug 2022, 3:00 pmClosed
PR & CC
This tender is initiated for False ceiling replacement and roofing replacement jobs under TN and Kerala
22000030-HD-11750
22000030-HD-11750
Open Tender
Morbi, Gujarat
₹0
₹2 L
8 Aug 2022
21 Jul 2022
8 Aug 2022
8 Aug 2022
21 Jul 2022 - 1 Aug 2022
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | REMOVAL OF FALSE | REMOVAL OF FALSE — Dismantling of all types of ceilings except of bk work/CC, sheets like AC, TRAC, GYPSUM BOARD etc. Scope of job includes handing over of all 'J', 'L' hooks, nuts and bolts, suspendors or other joineries in proper bags. Party to ensure joint measurement of the job to be dismantled, alongwith EIC, before start. Payment shall be made basis the joint measurement, in absence of any joint measurement record HPCL EIC decision shall be final. | - | Square Meters |
| 2 | REMOVAL OF ROOFING_TN | REMOVAL OF ROOFING_TN — REMOVAL AND STACKING OF THE EXISTING CANOPY ROOFING MATERIAL AND ROOFING SYSTEM AND STACKING THE REMOVED ROOFING MATERIAL MATERIAL AT UNOBJECTIONABLE PLACE AT THE RETAIL OUTLET AS DIRECTED BY THE EIC AND THE CONSULTANT. THE MATERIAL REMOVED FROM THE EXISTING CANOPY TO BE STACK PROPERLY WITH INDEXING THE MATERIAL GOOD FOR INSPECTION. | - | Square Meters |
| 3 | DISMAN OF EXISTING | DISMAN OF EXISTING — DISMANTLING AND REMOVING OF EXISTING GUTTERS. CARE SHOULD BE TAKEN FOR NOT DAMAGING THE EXISTING SHEETS AND STRUCTURE. REMOVING AND SHIFTING OF THE REMOVED MATERIAL AS PER INSTRUCTION OF ENGINEER-IN-CHARGE. Vendor to ensure to follow safety precautions while working at height to remove the AL gutter of canopy | - | Running Meter |
| 4 | SPLY AND INSTLN OF | SPLY AND INSTLN OF — SUPPLYING AND FIXING 20 SWG GI SHEET FACIA INCLUDING PAINTING WITH ONE COAT OF ZINC CHROMATE PRIMER AND TWO COATS OF 1STQUALITY SYNTHETIC ENAMEL PAINT ON FRONT SIDE . NECESSARY FACIA FRAMEWORK FOR FASTENING THE SHEET TO THE CANOPY SECURELY SHALL BE PAID SEPARATELY. THIS JOB NEED TO BE DONE WITH DUE APPROVAL OF EIC OF HPCL ON NEED BASIS ONLY | - | Square Meters |
| 5 | SPLY AND FIXG OF | SPLY AND FIXG OF — PROVIDING AND FIXING 20G ALUMINIUM GUTTER SUITABLY BENT WITH PROPER OVERLAPS, SEALANT, REVET, SCAFFOLDING, LABOUR, TRANSPORTATION, ETC, COMPLETE. THIS JOB NEED TO BE DONE WITH DUE APPROVAL OF EIC OF HPCL ON NEED BASIS ONLY | - | Running Meter |
| 6 | SPLY AND INSTLN OF | SPLY AND INSTLN OF — PROVIDING AND INSTALLING ROOFING RIBBED ROOFING SYSTEM MANUFACTURED WITH HIGH STRENGTH STEEL GRADE OF G550(550MPA) OF HPCL APPROVED BARE GALVALUME HIGH TENSILE COLD ROLLED STEEL AS PER ASTM 117 A792M/AS 1397 COATING CLASS AZM 150 (MINIMUM 150 GM/SQM ZINC-ALUMINUM ALLOY COATING MASS TOTAL OF BOTH SIDES), OF YIELD STRENGTH 550 MPA THICKNESS OF BARE METAL (BCT): 0.40MM,TOTAL COATED THICKNESS(TCT) : 0.45 MM .APPROXIMATE MASS OF ROOFING SHEET SHALL BE 4.17 KG/SQM. PANELS SHALL BE OF MIN. 900 MM WIDE AND MIN. CORRUGATION DEPTH OF 38 MM WITH VARYING LENGTHS AS PER SITE REQUIREMENTS RATE SHALL BE INCLUDING LAYING OF SHEETS WITH APPROVED FASTENERS AND ALSO ALL WEATHER SEALANT TAPE AS PER MFR''S RECOMMENDATIONS AND ALSO PROVIDING RIBBED GALVALUEME RIDGE PIECES OF THE SAME CLASS AS OF THE MATCHING CORRUGATION PROFILE OF THE ROOFING SYSTEM AS RECOMMENDED BY THE MFR.AND, HORIZONTAL/VERTICAL FLASHING NEAR ILLUMINATED BANDING . THIS JOB NEED TO BE DONE WITH DUE APPROVAL OF EIC OF HPCL ON NEED BASIS ONLY | - | Square Meters |
| 7 | SPLY AND FIXG OF FALSE | SPLY AND FIXG OF FALSE — PROVIDING AND FIXING GYPSUM BOARD FALSE CEILING WITH REQUIRED ACCESSORIES OF HPCL APPROVED MAKE INCLUDING PAINTING WITH TWO COATS OF PLASTIC EMULSION PAINT. 12.5 MM THICK ''GYPSUM BOARD'' SHALL BE SCREW-FIXED TO THE UNDERSIDE OF SUSPENDED GI GRID. GI GRID SHALL BE INSTALLED AS PER MANUFACTURER''S SPECIFICATIONS. GI GRID SHALL CONSIST OF CEILING SECTIONS (HPCL APPROVED) AT MAXIMUM C/C DISTANCE 450 MM, PERIMETER CHANNEL (HPCL APPROVED), INTERMEDIATE CHANNELS (HPCL APPROVED) AT MAXIMUM C/C DISTANCE 1200 MM. THE CEILING SECTIONS SHOULD BE FIXED TO INTERMEDIATE CHANNELS WITH CONNECTING CLIPS (HPCL APPROVED). GI GRID SHALL BE FIXED TO RCC SLAB ABOVE WITH THE HELP OF 25 X 0.5 MM STRAP HANGER (HPCL APPROVED) AND SOFFIT CLEAT (HPCL APPROVED). THE JOINTS BETWEEN SOFFIT CLEAT AND STRAP HANGER AND GI GRID AND STRAP HANGER SHALL BE WITH 6.4 X 12.7 MM NUT AND BOLT (HPCL APPROVED). SOFFIT CLEAT SHALL BE FIXED TO RCC CEILING WITH W.E. TYPE 12 MM DIA, 17/16 INCH LONG STEEL RAWL PLUG. MAXIMUM C/C DISTANCE (BOTH WAYS) OF STRAP HANGERS SHALL BE 1200 M. THE GYPSUM BOARD SHALL BE FIXED TO GI GRID WITH 25 MM LONG DRAW ALL SCREWS. THE GYPSUM BOARD TO BE USED SHALL BE 12.5 MM THICK TAPERED EDGE BOARDS. THE BOARDS SHALL BE TAPED AND FILLED FROM UNDERSIDE TO CEILING. THIS JOB NEED TO BE DONE WITH DUE APPROVAL OF EIC OF HPCL ON NEED BASIS ONLY | - | Square Meters |
| 8 | PAINTING OF CANOPY_TN | PAINTING OF CANOPY_TN — PAINTING OF CANOPY, CLEANING OF THE CANOPY FASCIA AND FALSE CEILING SURFACE TO REMOVE ANY OBSERVED RUST AND PROVIDING AND APPLYING 2 COATS OF SYNTHETIC ENAMEL PAINT 1ST QUALITY OF APPROVED MANUFACTURER AND SHADES ON THE SURFACE TO GIVE AN EVEN SHADE AFTER TWO COATS OF RED OXIDE PRIMER AS PER IS-712 LATEST REVISION. THE COLOUR SCHEME SHALL BE AS PER STANDARD HPCL COLOUR CODING. The Job to be done with prior approval of HPCL EIC. . The UoM given as EA to be read as per MT. | - | Each |
| 9 | INSTALLING SUPPLIED | INSTALLING SUPPLIED — TO INSTALL SUPPLIED LED FIXTURE OF CANOPY OR YARD LIGHT AT RETAIL OUTLETS OR OTHER PREMISES AS DECIDED BY HPCL. WORK INCLUDES PICKING UP OF FIXTURES, ACCESSORIES, CUT OUTS, CONTROLLERS ETC. FROM REGIONAL OFFICE, TRANSPORTING, STOCKING AT RETAIL OUTLETS. COST TO INCLUDE INSTALLATION OF FIXTURE AS PER MANUFACTURER RECOMMENDATION, WITH CHAIN OR GI WIRE HOLDING STRAPS, ACCESSORIES, MATERIAL, LABOR ETC.. VENDOR TO FOLLOW INSTRUCTIONS OF EIC FOR DECIDING THE LOCATION OF FIXTURE. CABLE, GLANDS WILL BE PAID EXTRA IF PROVIDED BY VENDOR. VENDOR HAS TO INSTALL THE LED LIGHT SUPPLIED BY HPCL | - | Each |
| 10 | SPLY&TRANSPT OF LIGHT | SPLY&TRANSPT OF LIGHT — SUPPLY AND TRANSPORTATION (TO RESPECTIVE ROS/YARD AS MENTIONED IN THE TENDER DOC) OF 80 W CANOPY LED LIGHT FIXTURE WITH MIN 140 LUMENS PER WATT EFFICACY FOR LEDS AND MIN 120 LUMENS PER WATT EFFICACY FOR THE SYSTEM. KINDLY READ THE DETAILED TECHNICAL SPECIFICATIONS AS PER THE ATTACHMENT. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
22000030-HD-11750.pdf
TENDER_DOCUMENT • 22.99 MB
111247.pdf
TENDER_DOCUMENT • 0.19 MB
Download all tender documents and submit your bid