Loading…
Loading…
Tender Value
₹56.9 L
EMD Value
₹56,877
Closing Date
3 Feb 2026, 6:00 pmClosed
DISTRICT PROJECT CO-ORDINATOR,CHHOTAUDEPUR
Construction of 04 Classroom Framed Structure in Different Primary School of Kawant Taluka in Chhotaudepur District.
268922
SS/TASP/ACR/CHHOTA/17
Open
Civil - All
Chhota Udaipur
1 document required · 1 mandatory
₹2,400
Yes
DIST PROJ COOR JILLA AYOJAN BOR VILL PRAYOJNA VAHIVAT VIKASSHIL TA CHHOTAUDEPUR
₹56,877
Yes
23 Jan 2026
23 Jan 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
No. 2023-24 L.C % L.C Unit Amount
Excavation for foundation upto 1.5 m depth including sorting out and
stacking of useful materials and disposing off the excavated stuff upto 222.57 148.19 1.48 149.67 Cmt
50 Meter lead.(B) Dense or hard soil
CH-4 ITEM CODE 04001B PG-46
Excavation for foundation for depth from 1.5 m to 3.0 m including
sorting out and stacking of useful materials and disposing off
2 the excavated stuff upto 50 Meter lead.(B) Dense or hard soil
CH-4 ITEM CODE 04002B PG-46
Providing & laying Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand :
graded stone aggregate 20 mm nominal size) & curing complete excluding
3 cost of form work Below Tie beam & Plinth protection.
CH-5 ITEM CODE 05010AA PG-48
Providing and laying controlled cement concrete M.150 for curing
complete including cost of formwork and excluding cost of reinforcement
for reinforced concrete work in (A) Foundations, footings,Base of 11.91 3963.89 39.64 4003.53 Cmt
columns and Mass concrete (Cement Level 290 Kg)
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundationand plinth in Cement Mortar 1:6. (1‐ 51.31 4725.60 47.26 4772.86 Cmt
Cement : 6 ‐finesand)(C) Fly Ash Bricks
CH-6 ITEM CODE 6002CA PG-58
Filling with the available excavated earth (excluding rock) in trenches, plinth,
sides of foundation etc. in layers not exceeding 20cm in depth consolidating 323.51 129.10 1.29 130.39 Cmt
each deposited layer by ramming and watering.
CH-4 ITEM CODE 04006 PG-47
thickness inculding watering, ramming and consolidation etc. complete. 246.47 286.20 2.86 289.06 Cmt
CH-4 ITEM CODE 04008A PG-47
Providing and laying controlled cement concrete M.250 for curing
complete including cost of formwork and excluding cost of reinforcement
for reinforced concrete work in (a) Foundations, footings Bases of 37.05 4214.00 42.14 4256.14 Cmt
columns and the like and Mass conrete work in footing. (Cement Level
Providing & laying Cement Concrete 1:4:8 (1 Cement :4 Coarse sand :8
hand brocken stone aggregates of 40mm nominal size) in plinth and curing 30.09 2653.67 26.54 2680.21 Cmt
complete excluding cost of formwork.
CH-5 ITEM CODE 05004A PG-49
Providing and laying controlled cement concrete M.250 for curing
complete including cost of formwork and excluding cost of reinforcement
10 for reinforced concrete work in Plinth Beams. (Cement Level 380 Kg)
Brick work using common burnt clay building bricks having crushing strength
not less than 35Kg./Sq.Cm. for superstructure in cement mortar 1:6(1 cement
11 :6 fine sand) including curing etc. complete. (C) Fly Ash Bricks For all heights
and all floor
CH-6 ITEM CODE 6002CA +6006C PG-58
Half brick in common brunt clay building bricks having crushing strength not
less than 35 Kg/sq.cm in cement mortar 1:4 (1 cement : 4 coarse sand) (C)
12 Fly Ash Bricks in super structure including curing etc. complete.For all floors
CH-6 ITEM CODE 6008A2A +6010B PG-59/60
Providing and laying controlled cement concrete M.200 for curing
complete including cost of formwork and excluding cost of reinforcement
13 for reinforced concrete work in Beams for all floors level. (Cement Level
Item SOR 1% SOR+1 Per Estimated
DESCRIPTION OF ITEM QTY
No. 2023-24 L.C % L.C Unit Amount
Providing and laying controlled cement concrete M.250 for curing
complete including cost of formwork and excluding cost of reinforcement
14 for reinforced concrete work in Column Up to Plinth & all floors..
(Cement Level 380 Kg)
Providing and laying controlled cement concrete M.200 for curing
complete including cost of formwork and excluding cost of reinforcement
15 for reinforced concrete work in Column for all floors level. (Cement
Level 360 Kg)
Providing and laying controlled cement concrete M.200 for curing
complete including cost of formwork and excluding cost of reinforcement
16 for reinforced concrete work in Slab for all floors level. (Cement Level
Providing and laying controlled cement concrete M.200 for curing
complete including cost of formwork and excluding cost of reinforcement
for reinforced concrete work in sloping slabs & Staircase having 8.04 5520.00 55.20 5575.20 Cmt
thickness more than 10 cm and upto 20 cm thickness.For all floors. (Cement
Level 360 Kg)
Providing and laying controlled cement concrete M.200 for curing
complete including cost of formwork and excluding cost of reinforcement
for reinforced concrete work in Chhajja for all floors level including 2.69 6551.00 65.51 6616.51 Cmt
finishing with cement mortar 1:3 ( 1 cement :3 Sand ) and curing etc
complete. (Cement Level 360 Kg)
Providing I.S.I. T.M.T Bars Fe.500D steel reinfocement (ISI mark) Confirmed
to IS-1786 for R.C.C.work including Cutting, bending, binding and placing in 19762.25 75.46 0.75 76.21 Kg
position etc. complete.For all floors
CH-5 ITEM CODE 05014C PG-50
Providing 10mm thick cement plaster in single coat on on brick/concrete
walls & Ceilling & Soffit of stair interior plastering in cement mortar 1:4(1
20 cement 4 sand) watering, curing etc. complete.For all floors
CH-17 ITEM CODE 17001B+17004A PG-89
Providing 15mm thick cement plaster in single coat on rough or fair side of
single or half brick wall for interior plastering in cement mortar 1:4(1 cement 999.12 233.58 2.34 235.92 Smt
4 sand) watering, curing etc. complete.For all floors
CH-17 ITEM CODE 17002A+17004A PG-89
20mm thick sand faced cement plaster on walls above ground level
consisting of 12mm thick backing coat of cement mortar 1:3(1 cement
22 sand) and 8mm thick finishing coat of cement mortar 1:1(1 cement 1 sand)
watering, curing etc.complete for any Height.
CH-17 ITEM CODE 17009 PG-89
Provinding & applying three coat of 100% acrylic base matt finishing exterior
paint of approved manufacture of required shade on external surface to give
23 an even shade after throughly brushing the surface free from morter
dropping & other foreign matter
Providing & laying 24"x24" vitrified 8mm thick tiles flooring over 20mm
(average) base of cement mortar 1:6(1cement:6course sand) on new surface
or fixing on exiting flooring by adhesivematerial including dismentalling of
existing flooring and jointed with colour cement slurry including finish with 298.18 1383.99 13.84 1397.83 Smt
flush pointing and cleaning the surface etc. complete for antiskid.(As Per List
of Approved Materials) for Light/Dark shade as per the given pattern.
(Item No- 14021A , Pg No- 85)
Providing and laying 25 mm th. Polish Kota stone slab flooring over 20mm.
(average) base of cement mortar 1:6 (1 cement :6 coarse sand) of L.M.
25 1:1.5 and laid and jointed with grey cement slurry including rubbing and
polishing complet.
(Item No- 14.43 , Pg.No. 84)
Providing & laying cement concrete flooring over 40 mm (average) thick
base of cement flooring 1:2:4 (1cement:2 coarse sand:4 graded stone
26 aggregates 20mm normal size) laid in one layer finished with a floating coat
of neat cement curing etc. complete.
Item SOR 1% SOR+1 Per Estimated
DESCRIPTION OF ITEM QTY
No. 2023-24 L.C % L.C Unit Amount
(Item No-14.71 , Pg.No. 85)
Providing cement vata (10cmx10cm size)quarter round in cement mortar 1:1
27 including neat cement finishing,watering etc. complete )
Providing & Fixing in position M.S.Angle 40mmx40mmx6mm Angle frame for
door and 35mmx35mmx5mm angle frame for shutters,18 gauge iron sheet of
28 shutters with 4 nos.of hold fasts for door as per the approved drawong & 1008.72 101.60 1.02 102.62 Smt
design including applying a priming coat.( Pg No-68) Sr.No. 10025AA
Providing & Fixing in position M.S.Angle 35mmx35mmx6mm frame for
windows & ventilation 25mmx25mmx5mm angle frame for shutters, 18 gauge
29 iron sheet of shutters with 4nos. Of hold fasts for windows & Ventilation as 893.36 101.60 1.02 102.62 Smt
per the approved drawing & design including applying a priming coat..( Pg
Providing & fixing M.S. Railing & M.S grill as per approved drawing & design
30 including one coat of red lead paint etc. complete.( Pg No-68 Sr.No100 1517.15 101.60 1.02 102.62 Kg
Painting two coats (Excluding Priming coat) on new steel and other metal,
surfaces with enamel paint, brushing,interior to give an even shade including
31 cleaning the surface of all dirt, dust and other foreign matter etc,complete
(Item No-19.7 , Pg.No. 93)
Providing & fixing G.I rain water Spout of 65mm dia and 60cm length. RA
Distempering with dry distemper of approved brand and manufacture (Three
Coats) and of required shade on wall surface to give an even shade, over
and including a priming coat of whiting after throughly brooming the surface 1223.17 60.80 0.61 61.41 Smt
free from mortar dropping and other foreign matter.
(Item No- 18.38, Pg.No. + 18.40 Pg.No. 91 )
Providing and fixing Chicken mesh jali (22 gauge)30cm wide at the junction
of 2 different surfaces of different material component at the time of
plastering to prevent cracking in plaster surface as and where directed at all
floors with all leads and lifts etc.complete.RA
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of pipe erected with
6A Modular type switch / bell push & accessories and earth continuity of
following type, erected on PVC / Metallic/Wooden box, single mounting base
35 frame covered with textured/metallic/white front plate modules erected on / 20.00 489.00 4.89 493.89 Pt.
in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed. (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete Cat. III ELE R&B 22-23
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected with 6A
Modular type switch and hum free EME four or more step type electronic fan
regulator with separately mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed. (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete Cat. III ELE R&B 22-23
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin
socket erected on PVC / Metallic/Wooden box, single mounting base frame
37 covered with textured / metallic/white front plate modules erected on / in 21.00 281.00 2.81 283.81 Pt.
wall / ceiling with following type accessories Cat. III ELE R&B 22-23 1-2-4
Item SOR 1% SOR+1 Per Estimated
DESCRIPTION OF ITEM QTY
No. 2023-24 L.C % L.C Unit Amount
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box
38 covered with appropriate front plate modules erected on / in wall / ceiling as 7.00 781.00 7.81 788.81 Pt.
per pipe erected with following type of accessories.[II] For 16A Plug and
amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(e) in existing
pipe erected flushed on wall/ceiling complete,Cat. III ELE R&B 22-23 1-2-3
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
39 metallic/white front plate , modules erected with necessary connections as 44.00 28.00 0.28 28.28 NO
per site situation directed by Engineer In charge. (7) Blank Plate Single
Cat.III ELE R&B 22-23 1-2-7
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected with
40 necessary PVC fittings & Junction boxes fixed with adhesive solution & 168.30 26.00 0.26 26.26 Rmt
Clamps with following dia of pipes, in approved manner as directed (a)20 mm
ELE R&B 22-23 1-3-2
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (A) with medium class Rigid PVC pipe and
accessories (a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (A) with medium class Rigid PVC pipe and
accessories (b) 2 wire 2.5 sq. mm ELE R&B 22-23 1-4-1
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq.
mmELE R&B 22-23 1-4-2
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of co-extruded polycarbonate channel with diffuser part in
needed opal finish with company mark/name 160V to 270V, Power Factor
more than 0.9, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy>
44 lumens/watt ,LED LED driver efficiency > 85 % ( fitting required LM-79 & LM- 20.00 345.00 3.45 348.45 NO
80 Certificates)(NOTE: Below description have shown ranges of Wattage
capacity between the ranges shown.),(A) Tube Light with integral driver,(ii)
18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet,Cat-lll ELE R&B 22-23 1-
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium blades with , canopy &
cm. down rod erected with 3 core flexible wire with earthing.(Make shall be
approved by Engineer in charge) R&B 22-23 5-1-6
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe
46 down rod erected duly painted for fan complete with proper insulation without 16.00 110.00 1.10 111.10 Rmt
leakage and earthing ELE R&B 22-23 5.2.2
Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC
slab with Making the site as original.ELE R&B 22-23 5-2-2
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
48 appropriate nos. of MCBs.(The DBs should be used of same company of 4.00 4525.00 45.25 4570.25 NO
MCB to be used) suitable for(B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type (PPI),(b) sheet steel
double door,(iv)12 way R&B 22-23 3-11-5
Item SOR 1% SOR+1 Per Estimated
DESCRIPTION OF ITEM QTY
No. 2023-24 L.C % L.C Unit Amount
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
Cat.III R&B 22-23 3-10-1(B)
providing and erecting Approved make ELCBs / RCCBs conforming to IS:
12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of
10 KA and suitable for operation on single phase 240 V,50Hz. having
50 characteristic of quick action & tripping with all advance feature & do not 4.00 2323.00 23.23 2346.23 NO
incorporate any electronic component. for following Max. rating erected as
directed (i) 25 Amps.DP Cat. III R&B 22-23
Providing & erecting 240 V MCB double pole switch for lighting Load (B
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing
box having following capacity (A) 6 to 32 Amp. Cat.III ELE R&B 22-23 3-10-3
Sheets steel powder coated enclosure suitable for incorporating One/Two
nos. MCB.ELE R&B 22-23 3-11-4
Providing & erecting Medium Voltage Danger Notice Board sticker as per
53 language suggested by engineer incharge of standard size as per IS-2551 8.00 30.00 0.30 30.30 NO
ELE R&B 22-23 3-13-3
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity ,(A) 6 to 32 Amp. Cat.III ELE R&B
Erection & connection charges for 16A / 32 A DP as following (b) on
polished wooden block.ELE R&B 22-23 3-6-2
Supplying & erecting earth pit of minimum bore dia.150mm size approved
make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber and heavy
56 duty cover.(approved make OEM has to submit test certificate) & having 3.00 5470.80 54.71 5525.51 NO
back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:-
0.2 / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time Necessary test
report must be submitted. (a) For Electrical Installation up to 440V in normal
soil Length of pipe - 1 Mtr Back filling compound - 1 Nos Bag of 15 Kg.
Providind and erecting HOT deep Galvanised iron strip wire 8 TO 16 SWG.
Total Rs.
Total Say RS.
I / WE am / are willing to carry out the work at ________ % above / below (percentage should be written in figures
Estimated amount put to tender Rs. ________________
Deduct / Add: _____ % below / above Rs. ________________
Net Amount Rs. ________________
in words _____________________________________________________________
(Please strike out which ever is not applicable)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
4 ACR BOQ Kawant.pdf
Drawing.pdf
SPECIFICATION-1.pdf
SS.TASP.ACR.CHHOTA.17.pdf
Download all tender documents and submit your bid