Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹37.9 L+₹3.1 L (8.90%)Rejected-AOC VILLAGE HARIGAON PO PS NIKAMUL SATRA TEZPUR DIST SONITPUR ASSAM | L2 | Rejected-AOC BEING NOT LOWEST BIDDER | |
| 3 | L3₹39.5 L+₹4.6 L (13.3%)Rejected-AOC 2ND FLOOR SC ROAD SANTA PLAZA TEZPUR DISTT SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-AOC BEING NOT LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Dec 2022, 6:00 pmClosed
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR/MAINT OF INTERNAL WIRING INCLUDING FITTING/FIXTURES AND RUNWAY LIGHTING AT AIRFIELD HANGER ETC AT ARMY AVN UNITS UNDER GE MISSAMARI
2022_MES_565842_1
8324
Open Tender
Electrical and Maintenance Works
Works
270 days
GE MISAMARI
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
Yes
GE MISAMARI
₹80,000
Yes
16 May 2023
29 Nov 2022
29 Dec 2022
29 Nov 2022
27 Dec 2022
13 Dec 2022
Amount
Taking out Runway light carefully from CI Transformer housing boxes by unscrewing nuts bolts and detaching isolating transformer and electrical connection repairing the same by opening Cover, re-wir-ing the Light Fitting with 2.5 Sqmm Copper Conductor Cable, multi-stranded, replacing unserviceable Parts as required/ordered, re-fix ing Light Fitting in Original Position after repaired and connecting up, complete all as specified and as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Isolating transformer, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the quoted rate.
Taking out unsv/burnt UG Control Cable/ Runway lighting cable of any cross sectional area etc laying in trenches all as specified and directed.
Taking out ATC Beacon from ATC Tower for repair and replacement of unsv component repair/rewinding of Synchronous motor and electrical connection repairing the same by opening Cover, re-wir-ing the Light Fitting with 2.5 Sqmm Copper Conductor Cable, multi-stranded, replacing unserviceable Parts as required/ordered, re-fix ing Beacon in Original Position after repaired and connecting up, complete all as specified and as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Control cable, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the quoted rate.
Segregation all parts of single phase 240 volts Synchronous Motor of any type, make and capacity obtained from item no 3 above, cutting & removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, rewinding the motor with superior quality enamelled copper winding wire of as original gauge, numbers of turns and coils including insulating material such as sleeves, cotton/PVC tape varnishing etc, reassembling the motor complete all as specified and directed.
Repair of unsv Constant current regulator panel at ATC CCR room by carefully opening of panel and removing unsv component and repair of unserviceable remote control desk ,including replacement of unserviceable IC,IGBT , Chip , IC Card,15 KW Transformer with panel control wiring complete all as specified and directed by Engr-in- charge. NOTE:– (a) Spare Parts such as IC,Chip , PCB electronic Card etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
S&F in replacement of unsv IGBT as per sample for Constant current regulator complete all as specified and directed.
S&F in replacement of unsv chip as per sample for Constant current regulator complete all as specified and directed.
S&F in replacement of unsv PCB Electronic card as per sample for Constant current regulator complete all as specified and directed.
S&F in replacement of unsv 15 KW output current transformer as per sample complete all as specified and directed.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 16 Sqmm 4 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connection to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. Note : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under relevant Items.
Supply,installation,testing and replacement of bidirectional approach light suitable for 200W,6.6 Amp AC constant current series system with bi pin halogen Lamp complete with all accessories such as base plate ,breakable coupling,mounting assembly ,gasket, Lamp Holder,Lenses,bi pin,Secondary lead of adequate length etc confirming to ICAO Annex 14 complete bidirectional type with clear/clear fitments, complete all as specified and as directed. Make : AMA/THORN
All as per item No 11 above, but 180 degree clear /yellow, complete all as specified and as directed.
All as per item No 11 above, but 180 degree Green /Red, complete all as specified and as directed.
All as per item No 11 above, but 180 degree Amber/yellow, complete all as specified and as directed.
S&F Omni directional taxi way edge light suitable for use with 45 W 6.6 A AC constant current series system complete with accessories such as base plate breakable coupling mounting assembly gasket lamp holder lenses bi pin secondary lead of adequate length confirming to ICAO Annex 14, complete all as specified and directed.
Supply and replacement for theHalogen lamp bipin holder 200W ,6.6 Amp. Spares for taxiway / Runway light fittings, complete all as specified and directed. Make:-Thorn/AMA
All as per item No 16 above, but Halogen lamp bipin holder 45W ,6.6 Amp.
All as per item No 16 above, but 180 deg Colour filters for runway lighting Red/Green/Yellow/Clear
All as per item No 16 above, but Clear spreader lens for APN approach light
All as per item No 16 above, but Green spreader lens for APN threshold light
All as per item No 16 above, but Red spreader lens for APN end light
All as per item No 16 above, but Base plate without gasket and bolts
All as per item No 16 above, but 360 deg outer clear lens for AUN Runway light fittimg.
All as per item No 16 above, but AMA connector kits for 6 sqmm copper conductor cable,5 KV Grade
All as per item No 16 above, but Breakable coupling for R/W/Taxi fittings
Supply installation testing in replacement of isolating transformer 5KV, 50 H Series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting System confirming to FAA/ICAO and IS 12290 1987 of capacity 200W ,6.6Amp,for runway lighting complete all as specified and directed. (Note:-Excavation,Sand cushioning,protective ,covering and refilling the trenches etc shall be measured and paid Separately)
Supply installation testing in replacement of isolating transformer 5KV, 50 H Series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting System conforming to FAA/ICAO and IS 12290 1987 of capacity 45W ,6.6Amp,for runway lighting complete all as specified and directed. Make-AMA/THORN
Supply ,laying ,jointing , testing and commisioning 6 Sqmm Airfield lighting cable single core 5KV Grade stranded copper conductor PVC insulated PVC sheathed unshielded antitermite and anti rodent treated unarmoured cable generally conforming to IS 1554 part I as amended upto date as specified in particular specification and all as required Make -Ankur and equivalent as approved by GE.
Supply and replacement of cast iron transformer housing boxes water tight cylindrical metal container of size 330 mm dia and 450 mm high all round cast iron moulding except top which will be 15 mm thick having two earth bolts nuts and washers 10 mm dia and one hole with GI nut to suit entry of 50 mm dia pipe .Opening on top with a cover plate to be fixed with neoprene rubber gasket etc ,including painting with one coat of synthetic paint as required including cement concrete/foundation PCC 1:2:4 using 20 mm graded crushed stone aggregate thickness of concrete 150mm in all the sides and 100 mm in bottom including dressing of earth soil and finishing with 12mm thick cement plaster 1:3 on exposed surface incl necessary excavation and earth work in any type of soil all as directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTES : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point complete all as specified.
M & L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed.
M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable all as directed.
S & F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed.
S & F GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed.
Repair and Maintenance of 'H' & 'T' indicator lamps including replacement of control wiring , painting of H/T indicator with existing yellow paint complete all as specified and all as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Control cable, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
Supply and fixing of Lamp of Higher suitable intensity as per aviation standard and as per sample obtained from item No 26 here in before suitable for H/T indicator complete all as specified and directed.
Supply and fixing of Lamp holder as per sample obtained from item No 26 here in before suitable for H/T indicator complete all as specified and directed.
Supply of Beacon halogen 500W light as per sample obtained from item No 3 here in before suitable for ATC Beacon complete all as specified and directed.
Servicing/Overhauling of 3 Phase, 3HP capacity Induction Motor alongwith movable housing with following others repairs :- (a) Taking out Motor and movable housing from its Position and disconnecting all Cable Connections. (b) Dismantaling of induction Motor complete Part by Part carefully, testing all Coils, degreasing bearing and display all the Parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts. (c) Heating & Varnishing to Stator with super quality varnish and dried out properely with external heat as ordered and as directed. (d) Reassembeling the Motor complete with all existing Serviceable Parts obtained against Item 1(b), greasing the Bearing with bearing grease and new Parts as ordered by Engineer-in-Charge (New Parts shall be measured and paid separately under relevant Item here-in after) (e) Reinstall the Motor at its existing Position, connecting all Cable connections and testing on completion complete all as specified and as directed. NOTE: i) Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of Motor are deemed to be included with the Unit Rate and labour element involved in replacement is included in unit rate quoated against this Item. (ii) Transportation of motor parts for machining, rewinding from work site to lathe shop (Work shop) are deemed to be included with the Unit Rate. (iii) Rewinding of Motor, any machine work where involved shall be measured and paid separetely against relevant Item of this Schedule.
Rewinding burnt coils of Induction Motor of any make and type of capacity, 3Phase, 3HP, 415Volts with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all as specified and as directed.
S & F 3 phase ,32A/415 V plastic handle Reverse Forward Switch for 3 HP induction motor complete all as specified and directed. Make:- Fybross or equivalent in reputed supplier.
S & F 3 phase,DOL Reversing Starters,complete with combination of 2 AC Electro Mechanical Contactor,with protection relay, Overload protection, Phase Loss, Phase Unbalance ,Suitable for 3 HP induction motor complete all as specified and directed.Make- Concord Electricals and equivalent in reputed make.
Greasing and overhauling of Hanger door guiding rail wheel , incl replacement of unsv shaft bearings , replacement of unsv GI wire rope, replacement of broken shaft of door mechanism for smooth movement of the hanger door leaves complete all as specified and directed by Engr-in- Charge . NOTE:– (a) Spare Parts such as Bearing, Wheel shaft, Wheel etc. wherever required to be included in the QUOTED UNIT RATE. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
S & F of 'V"/ Chain belt drive for Transfer of power to hanger gate lower wheel, complete all as specified and as directed.
S & F MCCB 4 Pole 250 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts, including spreader terminal, make: L&T Cat part No. CM92109OOP1OG and equivalent in Legrand/ Indo Asian complete all as specified.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 120 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed.Make - Polycab/ KEI/Havells NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid separately under relevant Items.
Taking down existing unserviceable Highbay light /Flood Light of any description/type/ size ,carefully from hanger Ceiling height of 18 mtr, batten/conduit including removal of batten/ conduit/ gutties/ wooden boards complete all as specified and directed.
Taking down the existing unserviceable main switch/ cut out/ DBs/ MCCB of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor for Highway / Flood Lights etc complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 6.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor complete all as specified and directed.
M & L Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 6.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor complete all as specified and directed.
M & L Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC concealled conduit ISI marked and its accessories including two run of single core 10 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor complete all as specified and directed.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Flood light fitting luminaire, with system efficiency ≥110 lumen/W,AC120-300 V with high power LEDs as light source and Secondary lenses 10KV SPD included with high efficiciency electronic driver of capacity 120 watts, with pre wired and necessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hanger beam angle of any description complete all as directed by Engineer- in-charge.Make: Make:Crompton, Cat No LFLN-120-CDL/60-M, Model- PLUTO NEO, Make-Crompton or eqv in Havells/Philips
S & F Energy saving new generation environmental friendly long life with high luminious efficacy upto ≥ 150 LPW versatile presure die cast aluminium IP 66 protected Highbay light fitting luminaire with descrete high lumen LEDs as light source and electronic driver of capacity 150 watts with pre wired and necessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hanger beam angle of any description complete all as directed by Engineer- in-charge.Cat No CIP-320-150-57-60D-HL4-GL-NSR, Model- SURROUND HYPERION, Make- CROMPTON or eqv in Havells/Philips.
S&F LEDs aviation light energy saving new generation environmental friendly long life versatile presure die cast aluminium housing with polycarbonate enclosure with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 and for fixing taking GI pipe pipe medium grade 40 mm dia 1.5 mtr long, complete all as specified and as directed. (Make :- BAJAJ, Cat Part No-110731 or equivalent in Havells/Phillips as approved by GE).
S&F in replacement Electronic LED Driver of suitable Capacity 150/200 Watt for Highbay/Flood Light, suitable for 220/230/240 Volt, complete all as specified and as directed.
S & F Recess mounted Environmental friendly ,asthetically designed ,ultra modern 2X2 luminaire 28W with high brightness SMD LED as Light source,suitable for Armstrong /Grid ceiling , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including suitable LED Driver complete all as directed by Engineer-in-Charge.Model:- PLUTO NEO PANEL 2X2 PLUTONEO2X2PLR28WLED840S , Make:-Havells or equivalent in Crompton/Philips
S & F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete including removal of old unsv sheet metal enclosure all as specified Model:-DBTPE004DD Make -L&T/Schneider/Indo asian/Legrand/Havells
S&F 63 A ,5 Pin (3 P+N+E) Metal Plug & Socket Enclosure for Three Phase connection, complete all as specified and directed. Model:- DBMPS463SD, Make :-L&T or equivalent in Schinider and Legrand/ Havells.
S&F MCB TPN 415 volts suitable for fixing in TPN DB of capacity 63 amps complete all as specified and directed. Model:-BB40630D of L&T or equivalent in Schinider/Legrand/Indo Asian/Havells
Supply and fixing for single pole and neutral enclosure with a two pin and earth plug and socket complete with on one single pole MCB 20 Amp, 240 volts, complete all as specified and directed. Make:- L&T/Havells/Legrand
S&F MCB SPN 230 volts suitable for fixing on MCB DB of capacity 32 TO 40Amps , complete all as specified and directed.
S&F MCB SP 6 to 30 Amps 240 volts for fixing on MCB DB's, complete all as specified and directed
S & F MCCB 4 Pole 200 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts,including spreader terminal complete all as specified and directed. make: L&T Cat part No. CM92109OON1OG and equivalent in legrand and Indo Asian
S & F sheet metal enclosure MCB VTPN 12 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for 4 Pole MCCB 200 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed. Make : Model No DBVTM012DD of L&T or equivalent in legrand and Indo Asian.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light Point controlled by One 1-Way Switch 5 Amp, complete all as specified and as directed.Make : KEI/Polycab/Havells
All as per item No 71 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator.Make : KEI/Polycab/Havells
All as per item No 71 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.Make : KEI/Polycab/Havells
Description all as per item No 71 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .Make : KEI/Polycab/Havells
All as per item No 71 here in before but for one bell point controlled by one, one way bell switch 5 Amps.Make : KEI/Polycab/Havells
Description all as per item No 71 here in before but for one light point controlled by one, two way switch 5 Amps.Make : KEI/Polycab/Havells
All as per item No 71 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.Make : KEI/Polycab/Havells
All as per item No 71 here in before but using 4 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for AC DB point incl running of 4 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.Make : KEI/Polycab/Havells
S&F switch piano (White) single pole flush type 5 amps, 230 volts.complete all as specified and directed.Make:- Havells REO/Legrand/L&T
S&F in replacement switch piano (White) single pole flush type, two way, 5 amps, 230 volts.complete all as specified and directed..Make:- Havells REO/Legrand/L&T
S&F in replacement bell push (White) flush type 5 amps, 230 volts.complete all as specified and directed..Make:- Havells REO/Legrand/L&T
S&F in replacement socket (White) flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Volts all as specified. .Make:- Havells REO/Legrand/L&T
S & F in replacement switch socket combination (White) flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and directed. .Make:- Havells REO/Legrand/L&T
S & F in replacement switch socket combination (White) 2 in 1 multipurpose 3/5 pin 5/15 amps flush type complete all as specified and directed. .Make:- Havells REO/Legrand/L&T
S & F in replacement ceiling rose (White) three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed..Make:- Havells REO/Legrand/L&T
S & F in replacement ceiling fan regulator (White) step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and directed. .Make:- Havells REO/Legrand/L&T
S&F in replacement lamp holder (White) insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/squareblockscomplete all as specified and directed. Make : Havells REO/Legrand/L&T
S&F call bell suitable to work on 230 volts Ac supply including removal of old unsv call bell complete all as specified. Make : Havells REO/Anchor/L&T
S&F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete including removal of old unsv sheet metal enclosure all as specified. Model:-DBSPN008DD Make -L&T/Schneider/Indo asian/Legrand
Servicing/Overhauling of 3 Phase, Pressure 12 Kgf/Cm2 capacity 500 Ltr Compressor alongwith movable housing with following others repairs and underlaying points:- (a) Taking out Motor and movable housing from its Position and disconnecting all Cable Connections. (b) Dismantaling of induction Motor complete Part by Part carefully, testing all Coils, degreasing bearing and display all the Parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts. (c) Heating & Varnishing to Stator with super quality varnish and dried out properely with external heat as ordered and as directed. (d) Reassembeling the Motor complete with all existing Serviceable Parts obtained against Item 39(b), greasing the Bearing with bearing grease and new Parts as ordered by Engineer-in-Charge (New Parts shall be measured and paid separately under relevant Item here-in after) (e) Reinstall the Motor at its existing Position, connecting all Cable connections and testing on completion complete all as specified and as directed. (f) Refilling of compressor oil as required at site and as directed. (g) Taking out unsv Automatic Cut off Relay and limit switches refixing the same as required at site. (h) Taking out unsv Pressure Release valve refixing the same as required at site. (j) Taking out unsv Star Delta starter refixing the same as required at site. NOTE: i) Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of Motor are deemed to be included with the Unit Rate and labour element involved in replacement is included in unit rate quoated against this Item. (ii) Transportation of motor parts for machining, rewinding from work site to lathe shop (Work shop) are deemed to be included with the Unit Rate. (iii) Rewinding of Motor, any machine work where involved shall be measured and paid separetely against relevant Item of this Schedule. (iv) Replacement of Automatic Cut off Relay , limit switches, Pressure Release valve and Star Delta starter wil be paid under supply only.
Rewinding burnt coils of Induction Motor of any make and type of capacity, 3Phase, upto 20HP, 415Volts with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all as specified and as directed.
Supply and topping up Compressor oil as per sample req and directed by Engr-in - Charge.
Supply and Fixing Limit Air Switch as per sample and directed by Engr-in - Charge.
Supply and fixing Automatic cut off relay as per sample and directed by Engr-in- Charge.
Supply and fixing Automatic timer as per sample and directed by Engr-in- Charge.
Supply and fixing Automatic Star Delta starter for motor of capacity 30 HP and as per sample and directed by Engr-in- Charge. Make : MN25FASD Cat No- SS94364 ,L&T
Supply and fixing Air Outlet Nozzle and regulator as per sample complete all as specified and as directed by Engr-in- Charge.
Servicing/Overhauling of 3 Phase, 40KVA UPS alongwith with following others repairs and underlaying points:- (a) Taking out Vertiv Make UPS from its Position and disconnecting all Cable Connections. (b) Dismantaling of Vertiv make UPS and removing unsv Part carefully, testing all Connection for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts. (c) Replacement of unsv Chip/relay/Semiconductor devices/diode and other Power electronics parts (d) Reassembeling the UPS complete with all existing Serviceable Parts obtained as ordered by Engineer-in-Charge (g) Taking out unsv Automatic Cut off Relay and refixing the same as required at site. NOTE: i) Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of UPS are deemed to be included with the Unit Rate and labour element involved in replacement is included in unit rate quoated against this Item. (ii) Transportation of Unsv parts for machining incl workshop charges are deemed to be included with the Unit Rate. (iii) New Chip/relay/Semiconductor devices/diode and other Power electronics parts for UPS will be included in quoted unit rate.Also Enginnering /consultancy charge from the company Rep will be bourne by contractor self.
R R ENTERPRISES
AVASANA SOLUTIONS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .